...

ABWR Figure 11.2-1 Radwaste System (Sheet 1 of 2)

by user

on
Category: Documents
13

views

Report

Comments

Transcript

ABWR Figure 11.2-1 Radwaste System (Sheet 1 of 2)
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
Figure 11.2-1 Radwaste System (Sheet 1 of 2)
21-822
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
Figure 11.2-1 Radwaste System (Sheet 2 of 2)
21-823
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
1
2
3
4
5
6
TO MAIN
CONDENSER
7
8
12
9
10
11
FROM AO
TO MAIN
CONDENSER
TO VENT
FROM AO
OG
GUARD BED
A
B
D
OG RECOMBINER
OG PREHEATER
C
F
OG CONDENSER
OG CHARCOAL ABSORBER
E
G
OG COOLER CONDENSER
OG FILTER
NORMAL OPERATION (DESIGN FLOW RATE)
CONTENTS
TEMPERATURE
UNIT
°C
MPa
[gage]
m3 /h
[normal]
3
m
/h
HYDROGEN [normal]
m3 /h
OXYGEN
[normal]
m3 /h
AIR
[normal]
m3 /h
STEAM
[normal]
PRESSURE(MAX)
FLOW RATE
1
2
105~148 105~148
NORMAL OPERATION (MINIMUM AIR FLOW RATE)
3
4
5
6
7
8
9
10
11
12
CONTENTS
150
~379
55
55
10
22~32
10~40
10~40
10~40
23~31
TEMPERATURE
~0
2.41~
-0.101
2.41~
-0.101
2.41~
-0.101
2.41~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
(0~)
7895
7895
7895
7764
57.1
57.1
48.8
48.8
48.8
48.8
52
262
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
131
131
131
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
7454
7454
7454
7716
(8.9)
(8.9)
(0.6)
(0.6)
(0.6)
(0.6)
(3.8)
262
262
H
OG VACUUM PUMP SYSTEM
UNIT
°C
MPa
[gage]
m3 /h
[normal]
3
m
/h
HYDROGEN [normal]
m3 /h
OXYGEN
[normal]
m3 /h
AIR
[normal]
m3 /h
STEAM
[normal]
PRESSURE(MAX)
FLOW RATE
1
2
105~148 105~148
3
4
5
6
7
8
9
10
11
12
150
~381
55
55
10
22~32
10~40
10~40
10~40
23~31
~0
2.41~
-0.101
2.41~
-0.101
2.41~
-0.101
2.41~
-0.101
7857
7857
7857
7726
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
0.11~
-0.101
(0~)
11.8
11.8
10.1
10.1
10.1
10.1
10.8
262
262
262
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
(~0.01)
131
131
131
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
(~0.005)
10
10
10
10
7454
7454
7454
7716
10
10
10
10
10
10
10
(1.8)
(1.8)
(0.1)
(0.1)
(0.1)
(0.1)
(0.8)
UTILITY (NORMAL OPERATION)
UNIT
A
B
FLUID
-
AIR
STEAM
W
SYSTEM
-
IA
HS
TCW
CONTENTS
TEMPERATURE
°C
PRESSURE
MPa
[gage]
FLOW RATE
-
C
D
W
---
E
W
HNCW
F
W
---
---
166
41
---
7~12
---
0.69
~0.87
0.62
MAX1.37
(0.35~
-0.101)
MAX1.37
(0.35~
-0.101)
MIN 370
6.19
ton/h
1.7~48.2
Nm3 /h
355
kg/h/unit
m3 /h/unit
5.3
m3 /h/unit
6.7kg/h
G
H
W
W
TCW
MUWP
41
---
MAX1.37 MAX 1.37
MIN 7
m3 /h/unit
0.15
m3 /h
Figure 11.3-1 Offgas System PFD (Sheet 1)
21-824
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
Figure 11.3-2 Offgas System P&ID (Sheet 1 of 3)
21-825
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
Figure 11.3-2 Offgas System P&ID (Sheet 2 of 3)
21-826
RS-5146900 Rev. 1
ABWR
Design Control Document/Tier 2
030A
PIC630A
SH2 D-3
E/P
RMS
NE
100A-OG-21-CS
F206
F745
O
FC
AO
OG
VACUUM PUMP(A)
FAILURE
PI
041
A
O
F203
PI
042
A
OG VACUUM
PUMP (A)
A
D111A
F019A
F188A
DRAIN
G
C002 PUMP TRIP
F748
LS
644
HH/MH/ML/LL/LLL
A
HH/LL/LLL
LI
644
RMS
LCW
150A-OG-23-2-CS
F022B
H/MH/ML/L
LS
643
LT
044
R
RMS
030B
E/P
AO
ND
F201
TRAIN CHANGE
O
ND
RMS
LI
643
LT
043
F749
F193A
F189A
F186A
A001
F744
F192A
F020B
100A-OG-19-2-SS-W/A
80A-OG-17-1-SS
OG
RECIRCULATION
WATER TANK
F190A
C
RADIATION MONITER HH
O
B
C
F205
F187B
PI
041
PI
042
B
OG VACUUM
PUMP (B)
DRAIN
C001B
D111B
F017B
100A-OG-16-2-CS
F202
B
F742B
F018
O
SH2 B-3
C
FC
AO
F741B
RMS
OG
VACUUM PUMP(B)
FAILURE
F023B
FC
A
ND
150A-OG-24-2-CS
100A-OG-16-1-CS
D107
F020A
80A-OG-18-1-SS-W/A
D113A
SH2 D-3
SD
CONDENSER
C001A
F191A
PIC630B
F204
VENT
C
F017A
F199
F546
F187A
F743
F018
C
150A-OG-20-CS
SD
ND
AO
F200
A
150A-OG-24-1-CS
DRAIN
FC
TRAIN CHANGE
F197
NE
RMS
F022A
F023A
FI
049
F196
RADIATION MONITER HH
150A-OG-23-1-CS
100A-OG-19-1-SS-W/A
F195
F547
F194
RMS
FC
F741A
MUWP OG
TO VENT
F021
G
C
MUWP
100A-OG-22-CS
R
RMS
O
F742A
PI
048
LCW
F019B
80A-OG-18-2-SS-W/A
80A-OG-17-2-SS
F192B
D113B
F191B
F186B
F193B
F190B
F189B
F188B
R
TRAIN CHANGE
DRAIN
LCW
RMS
TRAIN CHANGE
PI
045
A
OG
RECIRCULATION
WATER PUMP(A)
OVER LOAD
OG RECIRCULATION
WATER PUMP(A)
F183A
TCW
50A-TCW-***
DRAIN
/VENT
SD
O
C
F180A
F540A
SD
A
C002A
F182A
F541
DRAIN
/VENT
FC
AO
F181
D112A
TCW
50A-TCW-***
ND
RMS
NE
A
F746A
B
F747A
FIS
047
A
F542
L
F543
FC
AO
F185
DRAIN
B
O
C
DRAIN
LCW
DRAIN
LCW
LCW
F184B
R
NE
RMS
RMS
G
AO
F185
A
O
C
TRAIN CHANGE
OG
RECIRCULATION
WATER PUMP(B)
OVER LOAD
PI
045
A
OG RECIRCULATION
WATER PUMP(B)
B
FC
AO
F181
C002B
D112B
F184A
F183B
ND
RMS
B
F746B
PI
046
FC
F182B
B
O
C
F180B
F540B
A
A
TCW OG
FIS
047
F544
L
PI
046
B004
L
F545
A
RMS
G
OG RECIRCULATION
WATER COOLER
L
F747B
TRAIN CHANGE
DRAIN
LCW
DRAIN
LCW
Figure 11.3-2 Offgas System P&ID (Sheet 3 of 3)
21-827
Fly UP