Mini8 ® Controller
® Mini8 Controller Ranged to suit simple multi-loop and data acquisition applications The Mini8® Controller offers high performance control usually only found in Eurotherm® panel mount PID controllers. It is also a very competitive and compact data acquisition device. Its modular design enables its I/O and feature set to be selected to cater for a wide range of applications from simple to complex. • 16 control loops The Mini8 controller is an ideal partner to a programmable logic controller. Able to multi-drop on either Serial, Fieldbus or Ethernet communications. It offers a cost effective alternative to performing analogue measurement or loop control in a PLC. Implementing these functions in the Mini8 controller reduces the hardware cost of the PLC, relieving it of the burden of performing analogue functions, often allowing a lower specification processor to be used. • Remote HMI The feature set is comparable with the Eurotherm 3000 series panel controllers including its high performance PID control and SP programming functions together with a range of features such as Maths, Logic and Timing blocks. • OEM Security When used in a data acquisition installation the controller’s high density analogue I/O can be combined with Eurotherm’s 6000 series paperless graphic recorder. Control Optimise Simplify • 32 analogue inputs • Modular & compact • SP programming • Maths and logic • Modbus RTU • DeviceNet® network • Profibus DP network • Modbus TCP • EtherNet/IP • EtherCAT Setpoint programming The Mini8 controller can run up to 8 programmer function blocks, to follow a user defined series of ramp and dwell segments. Each programmer is capable of running a program of up to 16 segments with 8 event outputs. The event outputs can be used internally within the configuration soft wiring or to external digital or relay outputs. (Note that this depends on the type and number of the hardware outputs fitted). Recipes Using a PC tool, recipes can be created that can be used to change the operating parameters of the Mini8 controller simply by selecting a new recipe via the HMI. This is very useful where multiple products are processed using the same controller but require different parameters to be set. Heater failure detection The Mini8 controller with a CT3 input card fitted, has the capability of detecting failures in heater loads connected to its time proportioned outputs. By measuring the current flowing through the heaters via 3 current transformer inputs the Mini8 controller can, for up to 8 loops, detect Partial Load failure, Over Current, as well as SSR short or open circuit. Individual load current parameters indicate the measurement for each heater. The current monitor block utilises a cyclic algorithm to measure the current flowing through one heater per measurement interval. Toolkit blocks A range of toolkit functions, including Maths, Logic and Timing blocks can be used to create custom solutions and small machine controllers. Eurotherm iTools Graphical Wiring Editor The GWE is an extremely easy way to create applications. It allows users to select the function blocks they wish to use in their application then connect them together using ‘Soft Wiring’. The GWE gives the user a pictorial view of exactly what he has configured and can also be used to monitor runtime conditions. Specification General Environmental performance Power supply voltage: Supply ripple: Power consumption: Operation temperature: Storage temperature: Operating humidity: Applied voltage any terminal: 17.8V dc min to 28.8V dc max. 2Vp-p max. 15W max. 0 to 55°C –10 to 70°C 5% to 95% RH non-condensing 42V pk max. The Mini8 controller must be mounted in a protective enclosure. Electromagnetic compatibility (EMC) EN61326 for Industrial Environments EMC: This controller conforms with the essential protection requirements of the EMC Directive 2004/108/EC, by the application of EMC standard EN61326. This instrument satisfies the general requirements of the industrial environment defined in EN 61326. Electrical safety Meets EN61010, installation category II, pollution degree 2 Safety: INSTALLATION CATEGORY II This controller complies with the European Low Voltage Directive 73/23/EEC, by the application of the safety standard EN 61010. POLLUTION DEGREE 2 Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation shall be expected. Physical W124 x H108 x D115mm 1Kg typical DIN rail to EN50022 35 x 7.5 or 35 x 15 horizontally Dimensions: Weight: Mounting: Approvals CE, cUL listed (file E57766) Communications Network communications support Modbus RTU: DeviceNet: Profibus DP: Ethernet: EtherNet/IP: EtherCAT Baud rates: Baud rates: Baud rates: Baud rates: Baud rates: Baud rates: RS485, 2 x RJ45, user select switch for 3-wire or 5-wire 4800, 9600, 19200 CAN, 5-pin standard "open connector" with screw terminals 125k, 250k, 500k RS485 via standard 9 pin D connector or 2 RJ45 connectors Up to 12M set by the Master Standard Ethernet RJ45 connector 10baseT Standard Ethernet RJ45 connector 10baseT 100baseT Standard Ethernet RJ45 connector 10baseT 100baseT Modbus /DeviceNet /Profibus /Ethernet/EtherNet/IP /EtherCAT are mutually exclusive options; refer to the Mini8 controller Order Code. Configuration communications support Modbus RTU: RS485, 2 x RJ45, user select switch for 3-wire or 5-wire Fixed I/O resources The PSU card supports 2 independent and isolated relay contacts. On/Off (C/O contacts, "On" closing the N/O pair) Relay output types: <1A (resistive loads) Contact current: <42V pk. Terminal voltage: Gold Contact material: Snubber networks are NOT fitted Snubbers: 42V pk max. Contact isolation: OEM Security An OEM or reseller can protect their intellectual property by preventing unauthorised cloning of the configuration. 2 | Mini8 Data Sheet The PSU card supports 2 independent and isolated logic inputs Logic (24V dc) Input types: –28.8V to +5V dc Input logic 0 (off): +10.8V to +28.8V dc Input logic 1 (on): 2.5mA (approx.) at 10.8V; 10mA max at Input current: 28.8V supply 110ms min. Detectable pulse width: 42V pk max. Isolation to system: DI8 8-channel logic input card Input/Output cards TC8 8-channel and TC4 4-channel TC input card The TC8 supports 8 independently programmable and electrically isolated channels, catering for all standard and custom thermocouple types. The TC4 supports 4 channels to the same specification. Channel types: Input Range: Resolution: Temperature coefficient: Cold junction range: CJ rejection: CJ accuracy: Linearisation types: Total accuracy: Channel PV filter: Sensor Break: Input resistance: Input leakage current: Common mode rejection: Series mode rejection: Isolation channel-channel: Isolation to system: TC, mV –77mV to +77mV 20 bit (∑∆ converter), 1.6µV with 1.6s filter time < ±50ppm (0.005%) of reading/ °C –10°C to +70°C > 30:1 ±1°C C, J, K, L, R, B, N, T, S, LINEAR mV, custom ±1°C ± 0.1% of reading (using internal CJC) 0.0 seconds (off) to 999.9 seconds, 1st order low-pass AC detector: Off, Low or High resistance trip levels >100M <100nA (1nA typical) >120dB, 47 – 63Hz >60dB, 47 – 63Hz 42V pk max. 42V pk max. The DI8 supports 8 independent input channels. Input Input Input Input types: logic 0 (off): logic 1 (on): current: Detectable pulse width: Isolation channel-channel: Isolation to system: RT4 resistance thermometer input card (PT100) The RT4 supports 4 independently programmable and electrically isolated resistance input channels. Each channel may connected as 2 wire, 3 wire or 4 wire. Channel types: Input range: Calibration error: Resolution: Measurement noise: Linearity error: Temp coefficient: DO8 8-channel digital output card Lead resistance: The supply line is protected to limit total card current to 200mA. Bulb current: Isolation channel-channel: Isolation to system: The DO8 supports 8 independently programmable channels, the output switches requiring external power supply. Each channel is current and temperature protected, foldback limiting occurring at about 100mA. The 8 channels are isolated from the system (but not from each other). To maintain isolation it is essential to use an independent and isolated PSU. Channel types: Channel supply (Vcs): Logic 1 voltage output: Logic 0 voltage output: Logic 1 current output: Min. pulse time: Channel power limiting: Terminal supply protection: Isolation (channel-channel): Isolation to system: On/Off, Time Proportioned 15V dc to 30V dc > (Vcs - 3V) (not in power limiting) < 1.2V dc no-load, 0.9V typical 100mA max. (not in power limiting) 20ms Current limiting capable of driving shortcircuit load Card supply is protected by 200mA selfhealing fuse N/A (Channels share common connections) 42V pk max. RL8 8-channel relay output card The RL8 supports 8 independently programmable channels. This module may only be fitted in slot 2 or 3, giving a maximum of 16 relays in a Mini8 controller. On/Off, Time Proportioned 264V ac 2 amps ac Fitted on module 5V dc, 10mA 220ms 264V 230V nominal 264V 230V nominal CT3 3-channel current-transformer input Card The CT3 supports 3 independent channels designed for heater current monitoring. A scan block allows periodic test of nominated outputs to detect load (failure) changes. Channel types: Factory set accuracy: Current input range: Transformer ratio: Input load burden: Isolation: A (current) Better than ±2% of range 0mA to 50mA rms, 50/60Hz nominal 10/0.05 to 1000/0.05 1W None (provided by CT) Resistance/PT100 0 to 420 ohms, –242.02°C to +850°C for PT100 ±0.1ohms ±0.1% of reading, 22 to 420 ohms ±0.3°C ±0.1% of reading, -200°C to +850°C 0.008 ohms, 0.02°C 0.016 ohms, 0.04°C peak to peak, 1.6s channel filter 0.06 ohms, 0.15°C peak to peak, no filter ±0.02 ohms, ±0.05°C ±0.002% of ohms reading per °C ambient change relative to normal ambient 25°C 22 ohms max in each leg. Total resistance including leads is restricted to the 420 ohm maximum limit. 3 wire connection assumed matched leads. 300μA 42V pk max 42V pk max RT4 resistance thermometer input card (PT1000) The RT4 supports 4 independently programmable and electrically isolated resistance input channels. Each channel may connected as 2 wire, 3 wire or 4 wire. Channel types: Input range: Calibration error: Resolution: Measurement noise: Linearity error: Temp coefficient: Lead resistance: The Mini8 controller chassis must be earthed (grounded) using the protective earth stud. Channel types: Maximum contact voltage: Maximum contact current: Contact snubber: Minimum contact wetting: Min. pulse time: Isolation (channel-channel): Isolation to system: Logic (24V dc) –28.8V to +5V dc +10.8V to +28.8V dc 2.5mA (approx.) at 10.8V; 10mA max at 28.8V supply 110ms min. 42V pk max. 42V pk max. Bulb current: Isolation channel-channel: Isolation to system: Resistance/PT1000 0 to 4200 ohms, –242.02°C to +850°C for PT1000 ±0.8ohms ±0.1% of reading, 220 to 4200 ohms ±0.2°C ±0.1% of reading, -200°C to +850°C 0.6 ohms, 0.15°C 0.2 ohms, 0.05°C peak to peak, 1.6s channel filter 0.6 ohms, 0.15°C peak to peak, no filter ±0.2 ohms, ±0.05°C ±0.002% of ohms reading per °C ambient change relative to normal ambient 25°C 22 ohms max in each leg. Total resistance including leads is restricted to the 4200 ohm maximum limit. 3 wire connection assumed matched leads. 300μA 42V pk max 42V pk max AO8 8-channel and AO4 4-channel 4-20mA output card The AO8 supports 8 independently programmable and electrically isolated mA output channels for 4-20mA current-loop applications. The AO4 supports 4 channels to the same specification. The AO4 and AO8 modules may only be fitted in slot 4. Channel types: Output range: Setting accuracy: Resolution: Isolation channel-channel: Isolation to system: mA (current) Output 0-20mA, 360Ω load max. ±0.5% of reading 1 part in 10000 (1uA typical) 42V pk max. 42V pk max. Load failure detection Requires CT3 module. Max number of loads: Max loads per CT: Alarms: Commissioning: Measurement interval: 16 Time Proportioned Outputs 6 loads per CT input 1 in 8 Partial load failure, Over current, SSR short circuit, SSR open circuit Automatic or manual 1 sec – 60 sec Mini8 Data Sheet | 3 Process alarms Software features Toolkit blocks User wires: User values: 2 input maths: Orderable options of 30, 60, 120 or 250 32 real values 24 blocks Add, subtract, multiply, divide, absolute difference, maximum, minimum, hot swap, sample and hold, power, square root, Log, Ln, exponential, switch 24 blocks AND, OR, XOR, latch, equal, not equal, greater 2 input logic: than, less than, greater than or equal to, less than or equal to 4 blocks AND, OR, XOR 8 input logic: 8 input multiple operator: 4 blocks Maximum, Minimum, Average. Input/Outputs to allow cascading of blocks 4 blocks 8 sets of 8 values selected by input parameter 8 input multiplexer: 2 blocks 2 decades (8 inputs giving 0 to 99) BCD input: 2 blocks Max, min, time above threshold Input monitor: 16 point linearisation: 2 blocks 16-point linearisation fit Polynomial fit: 2 blocks Characterisation by poly fit table Switchover: 1 block Smooth transition between two input values 8 blocks OnPulse, OnDelay, OneShot, MinOn Time Timer blocks: 2 blocks Up or down, Directional flag Counter blocks: 2 blocks Alarm at Threshold value Totaliser blocks: Real time clock: 1 block Day & time, 2 time based alarms Transducer scaling: 2 blocks Transducer Auto-tare, calibration & comparison cal PID control loop blocks Number of Loops: Control modes: Control outputs: Cooling algorithms: Tuning: Auto manual control: Setpoint rate limit: Output rate limit: Other features: Number of alarms: Alarm types: Alarm modes: 32 analogue, 32 digital, 32 Sensor break Absolute high, absolute low, deviation high, deviation low, deviation band, sensor break, logic high, logic low, rising edge, falling edge, edge Latching or non-latching, blocking, time delay Setpoint programmer The Setpoint Programmer is a software orderable option. Number of programs: Number of segments: Number of event outputs Digital inputs: Power failure action: Servo start: 8 128 8 per program (64 total) Run, Hold, Reset, Run/Hold, Run/Reset, Program Advance, Skip, Segment, Sync Ramp, Reset, Continue PV, SP Recipes Recipes are a software orderable option. Number of recipes: Tags: 8 24 tags in total 0, 4, 8 or 16 Loops (order options) On/Off, single PID, Dual channel OP Analogue 4-20mA, Time proportioned logic Linear, water, fan, or oil 3 sets PID, One-shot auto-tune Bumpless transfer or forced manual output available Ramp in units per sec, per min or per hour Ramp in % change per second Feedforward, Input track, Sensor break OP, Loop break alarm, remote SP, 2 internal loop setpoints Mechanical Details Allow min 25mm above and below each unit Allow min 25mm for terminals and cables Mounting Information The Mini8 controller is intended to be horizontally mounted on symmetrical DIN Rail to EN50022-35 or 35 x 35 x 15 108mm 124mm 4 | Mini8 Data Sheet 115mm Communications Interface LEDs Legend Colour RN/RUN Green Function Run mode LEDs Action On – Running Blinking – Standby/Config Off – Not Running RUN (EtherCAT only) Off – the device is Initialisation, INIT state Blinking – the device is in the Pre-Operational state Single Flash – the device is in the Safe Operational state On- the device is in the operational state Flickering – the device is booting, but has not entered INIT state CC Green Configuration activity On – N/A Blinking – Config Traffic Off – N/A FC Green Field Comms activity On – Connected Non-enhanced DeviceNet® Blinking – Ready Off – Offline Modbus, Profibus, and Ethernet Off – No traffic or offline Blinking – Comms Traffic NET MOD ERR Bi-Col Bi-Col RED Network Status (enhanced DeviceNet only) Off – Offline Blinking Green – Online but no connections On Green – Online with connections Blinking Red – Connection timed out On Red – Total connection failure Blinking Red/Green – Comms fault Network Satus (EtherNet/IP only) Off – Not online Flashing Green – Online but no connection Steady Green – Online and operating correctly Flashing Red – Connection timeout Steady Red – Duplication of IP address Flashing Green and red – Initialisation Module Status (enhanced DeviceNet only) Off – Power not supplied to network On Green – DeviceNet interface operational On Red – Power not supplied to controller or Checksum failure Blinking Red/Off – Recoverable fault. Comms. error between network and DeviceNet interface Blinking Red/Green – Power-up tests, failure to enter cyclic states or invalid baud rate Module Status (EtherNet/IP only) Off – Not online Flashing Green – Online but no connection Steady Green – Online and operating correctly Flashing Red – Connection timeout Steady Red – Duplication of IP address Flashing Green and Red – Initialisation Error Status Indication (EtherCAT only) Off - No error On - Application Failure, no communications with Mini8 Power Supply Legend Supply 24V 24V 0V GND 24V dc 24V dc 0V Ground Legend P Colour Green Function Indicates Power status A Red Indicates Relay A state B Red Indicates Relay B state Action On – Power On Off – Power Off On – Energised Off – De-Energised On – Energised Off – De-Energised RL8 AO8/A04 Relay Output (slots 2 and/or 3 only) Ananlogue Output (slot 4 only) Contact voltage/current – 264V ac/2A RMS max. Output current – 0 to 20mA 360 ohm max. load. ISOLATION (264V ac Basic) • Channel to Channel: 264V ac Basic • Channel to system: Reinforced ISOLATION • Channel to Channel: 42V pk. • Channel to system: 42V pk. Note. Protective earth conductor MUST be used if RL8 module is fitted. Note. AO4 supports Channels 1 to 4 only. Legend A B C D E F G H I J K L M N O P Function RLY1 A RLY1 B RLY2 A RLY2 B RLY3 A RLY3 B RLY4 A RLY4 B RLY5 A RLY5 B RLY6 A RLY6 B RLY7 A RLY7 B RLY8 A RLY8 B Legend A B C D E F G H I J K L M N O P Function OP1+ OP1– OP2+ OP2– OP3+ OP3– OP4+ OP4– OP5+ OP5– OP6+ OP6– OP7+ OP7– OP8+ OP8– Standard I/O Connections Linked This terminal can accept wire sizes 0.2 - 2.5mm (24 – 12 awg). POWER SUPPLY SPECIFICATON Power supply voltage: 17.8V dc min to 28.8V dc max. Power comsumption: 15W max. Legend Function D1 Digital Input 1 D2 Digital Input 2 C Digital Input Common A1 Relay A n/open A2 Relay A n/closed A3 Relay A Common B1 Relay B n/open B2 Relay B n/closed B3 Relay B Common Note. Digital Inputs: ON requires greater than 10.8V with 2mA drive, 30V max. Relay Contacts: 1 Amp max, 42V dc max. COMMUNICATIONS Communications connection terminals are version dependant. TC8/TC4 RT4 DI8 CT3 DO8 Thermocouple Input 2, 3, 4 Wire RTD Input Logic Input Transformer Input Logic Output ISOLATION • Channel to Channel: 42V pk. • Channel to system: 42V pk. ISOLATION • Channel to Channel: 42V pk. • Channel to system: 42V pk. ISOLATION • Channel to Channel: 42V pk. • Channel to system: 42V pk. ISOLATION • Channel to Channel: N/A • Channel to system: N/A ISOLATION • Channel to Channel: N/A • Channel to system: 42V peak with independant supply Note. Input specification as for Standard I/O above. Note. Isolation provided by current transformers. Notes. Requires 24V dc supply. * Linked internally. Note. TC4 supports Channels 1 to 4 only. Legend A B C D E F G H I J K L M N O P Function TC1+ TC1– TC2+ TC2– TC3+ TC3– TC4+ TC4– TC5+ TC5– TC6+ TC6– TC7+ TC7– TC8+ TC8– Legend A B C D E F G H I J K L M N O P Function CH1 I+ CH1 S+ CH1 S– CH1 I– CH2 I+ CH2 S+ CH2 S– CH2 I– CH3 I+ CH3 S+ CH3 S– CH3 I– CH4 I+ CH4 S+ CH4 S– CH4 I– Wire Connections 2 3 4 Legend A B C D E F G H I J K L M N O P Function D1+ D1– D2+ D2– D3+ D3– D4+ D4– D5+ D5– D6+ D6– D7+ D7– D8+ D8– Legend A B C D E F G H I J K L M N O P Function N/A N/A N/A N/A N/A N/A N/A N/A In1 A In1 B No connection In2 A In2 B No connection In3 A In3 B * Legend A B C D E F G H I J K L M N O P Function Supply in + Supply in + OP1+ OP2+ OP3+ OP4+ Supply & OP Supply & OP – Supply in + Supply in + OP5+ OP6+ OP7+ OP8+ Supply & OP Supply & OP – * Mini8 Data Sheet | 5 Order Code 1 2 3 15 16 17 4 5 6 7 8 9 10 11 12 13 MINI8 Basic Product Mini8 Controller MINI8 5 Temperature Units C F 11 Wires Centigrade Fahrenheit 30 60 120 250 1 Control Loops ACQ 4LP 8LP 16LP IO Acquisition only 4 Control loopsr 8 Control loops 16 Control loops 2 Programs 0PRG 1PRG XPRG No programs 1 profile – 50 programs Multi-profiles – 50 programs (Note 1) 6-9 IO Slots 1, 2, 3, 4 XXX TC4 TC8 RT4 AO4 AO8 DO8 CT3 RL8 3 PSU VL 24V dc DI8 No module fitted 4 Ch TC input 8 Ch TC input 4 Ch RTD PT100/PT1000 input 4 Ch 4-20mA O/P (Note 3) 8 Ch 4-20mA O/P (Note 3) 8 Ch logic O/P 3 Ch CT input (Note 4) 8 Ch relay O/P (Note 5) 8 Ch logic input 10 Applications 4 Communications Non isolated Modbus Slave ISOLMBUS Isolated Modbus RTU Slave DEVICENET DeviceNet Slave PBUSRJ45 Profibus Slave RJ45 (Note 2) Profibus Slave 9 Pin PBUS9PIN D type (Note 2) ENETMBUS Ethernet Modbus TCP/IP Slave DeviceNet M12 DNETM12 Connector Slave EtherNet/IP ENETIP ETHERCAT EtherCAT MODBUS STD EC8 FC8 No configuration 8 Loop extrusion controller (Note 6) Requires 8LP or 250 wires and modules placed in the following slots Slot 1 = TC8 Slot 2 = CT3 or XXX Slot 3 = DO8 Slot 4 = DO8 8 Loop furnace controller Requires 8LP or 250 wires and modules placed in the following slots Slot 1 = TC8 Slot 4 = AO8 Eurotherm Limited 12 Recipes NONE RCP No recipes 8 Recipes ENG FRA GER SPA ITA English French German Spanish Italian 14 Configuration Software English ENG NONE No DVD ITOOLS Eurotherm iTools DVD & Mini8 Controller documentation 16 Calibration Certificates XXXXX CERT1 CERT2 None Certificate of Conformity Factory input aalibration per input (Note 7) XXXXX Standard EU0725 OEM Security Notes 1. 2. 3. 4. 5. 6. 7. HA031260 SUBMINI8/SHUNT/249R.1 RES250 RES500 CTR100000/000 CTR200000/000 CTR400000/000 CTR500000/000 iTools/None/3000CK SUB21/IV10 Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice. The information in this document is given in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any losses arising from errors in this document. Document Number HA028480 Issue 10 Standard Extended If 4 Loops ordered 4 programmers are supplied; 8 or 16 loops ordered 8 programmers are supplied. Profibus motherboard fitted. AO4/AO8 in slot 4 only. Only 1 CT3 per Mini8. RL8 in slots 2/3 only. EC8 is a preconfigured version of Mini8 offering 8 control loops with Heat/Cool logic outputs. CERT2 is 5 point calibration. Accessories All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior written permission of Eurotherm Limited. Scan for local contacts XXXXX WL005 17 Specials 13 Manual Language Eurotherm by Schneider Electric, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris, EPower, EPack, nanodac, piccolo, versadac, optivis, Foxboro and Wonderware are trademarks of Schneider Electric, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners. Faraday Close, Durrington, Worthing, West Sussex, BN13 3PL Phone: +44 (01903) 268500 Fax: +44 (01903) 265982 www.eurotherm.com/worldwide 30 30 User Wires 60 User Wires 120 User Wires 250 User Wires 15 Warranty Engeering/DVD manual 2.49R Precision resistor 250R resistor for 0-5V dc OP 500R resistor for 0-10V dc OP 10A Current transformer 25A Current transformer 50A Current transformer 100A Current transformer Configuration clip 0-10V input adaptor © Copyright Eurotherm Limited 2015 14 July 2015