AC Ratio Current & Voltage Meters UAF / UVF Specification
by user
Comments
Transcript
AC Ratio Current & Voltage Meters UAF / UVF Specification
AC Ratio Current & Voltage Meters UAF / UVF Specification Input range UAF : 0-6A AC, 40-70Hz, suitable for 5A, 1A rating UVF : 0-150V AC, 40-70HZ Accuracy (23 ±3°C) (23± 0.2% fs, AC true RMS conversion Digits & counts 4-1/2 digits -1999.9 counts maximum Display 0.56” super rate LED Introduction Ratio setup Model UAF & UVF series, are designed under micro base with digital setup directly to PT or CT ratio and auto- Digital setup in PT, CT ratio Ratio range : 0.1~1999.9 Auto range in display reading to primary scale scaling in display to primary reading. The specifications of the units, truly a real power system Response time design, compliant ANSI-IEEE & DIN-IEC, VDE those standards providing full protection for surge intrusion & Input burden unusual over input to assure safety operation. Input over Features Digital setup for PT, CT ratio and auto range scale AC true RMS conversion Wide auxiliary power range AC / DC 30-250V High over capability High accuracy of 0.2% Dielectric strength ANSI/IEEE C37.90-1989, DIN-IEC 255-4 / 1977 IEC 801-4 / 1988 Impulse voltage 0-6A AC current input for CT ratio 0-150V AC voltage input for PT ratio Ordering Impulse voltage 1.2 x 50us 5KV Oscillating wave 0.5us~100KHz 4KV & 1MHz~0.25ms 4KV Stability Temperature range -10 to +55°C Maximum : < 50ppm / °C Long term stability < 0.2% drift maximum per year UAF Power Input UAF UVF UAF : current input 3 x rating continuous 10 x rating 30 sec 50 x rating 3 sec 80 x rating 1 sec UVF : Voltage input Maximum continuous 750V rms, 1500V 30 sec Surge test Model & Ordering Model 0.1 VA maximum 2.5KV AC rms 1 minute, all terminals to case 2KV AC rms 1 minute common voltage, between input to power terminal 4-1/2 digits Display with super rate LED Model : UAF UVF Sample rate 1 of per sec typically 0 : AC 1A 1 : AC 5A 0 : AC 0-150V 0 : AC / DC 30-250V 1 : DC 24V ±20% Operating condition Temperature range -10 to 55°C, 0~99% RH non-condensed Storage Temperature range -25 to 70°C, 20~99% RH non-condensed A uxiliar w er uxiliaryy po pow AC / DC 30-250V < 3 watts, (40-70Hz for AC) AC Ratio Current & Voltage Meters S1 S2 S3 S1 S2 UAF / UVF S3 A KV Function key Wiring S1 : Previous status, back to main display S2 : Numeric up 0~9 S3 : Enter or execution : Keying Sx ( S1, S2, S3 ) Model : UAF / UVF 1 Ratio setting z z z PS00 S3 0000 1 1 1 1 S2 S3 S2 S3 S2 S3 S2 S3 1 1 1 5 6 AC / DC Power 49mm Enter password (1111) and enter ratio range 0 0 0 0. 0 97mm S3 Write ratio N1 S2 S3 N2 N3 S2 S3 S2 S3 Example Ratio = 75 = 360 = 1200 = 205.5 = 1600.3 z 4 - Dimension Write password ( 1111) 1 z 3 Input Enter password S3 2 + 0 0 1 0 1 0 3 2 2 6 7 6 0 0 0 N4 N5 S2 S3 S2 S3 5 0 0 5 0 Enter ratio and return to main display 0 0 0 5 3 7mm Slide Bracket 5mm Max. 106mm Cut out S2 S1 92mm+1 45mm