Test Instrumentation & Automated Test Systems Power Conversion Hipot / Safety Component
by user
Comments
Transcript
Test Instrumentation & Automated Test Systems Power Conversion Hipot / Safety Component
Power Conversion Hipot / Safety Component Automated Systems Test Instrumentation & Automated Test Systems Automated Systems Automated Test Systems Chroma’s engineering team delivers cost-effective architecture and software platforms designed to fit our customer’s diverse power conversion and electrical safety test technical requirements by maximizing their time, improving validation processes, and increasing output. Our engineering capabilities provide for the design, development and delivery of turnkey automated test systems and fixtures for many power conversion and electrical safety test applications. We also provide modification and updating of existing test systems. Our area of expertise is power conversion test and characterization delivering automated solutions to many industries. Power Conversion EV / EVSE • Switching Power Supply • EV Charging • PC Power Supply • DC–DC Converter • Telecom Power Supply • HEV Controller / DC-DC • Motor Driver Battery Medical / Safety • Programmable Charge/Discharge • Medical Device – IEC60601-1, IEC 60601-2-49 (Multifunctional Patient Monitoring Equipment) • Regenerative Battery Pack • Secondary Battery Module and Pack • Electrical Equipment Safety and Function Test LED / Lighting Solar • LED Power Driver • On-Grid PV Inverter • High Speed LED Bulb or Tube In-line • Off-Grid PV Inverter • LCD Inverter / Ballast • Solar Panel Military / Aerospace Regenerative Burn-in • Repair Depot • AC - AC Power Supply • Government Contract / Tier-1 Support • DC - DC Converter • LED Driver • Design Verification Test Telecom ATS HEV Controller / DC-DC ATS PV Inverter ATS 2 chromausa.com/systems EV Charger ATS 17030 Regenerative Battery Pack ATS Switching Power Supply ATS DC - DC Converter ATS 17020 Programmable Charge/Discharge ATS 8000 Automated Test Platform Hardware Software Test Fixtures • Widest Selection of High Precision Test Instrumentation • Enterprise Wide Open Architecture Platform • Engineering Characterization & Design Validation • Highly Customizable Configurations & UUT Interfaces • Custom Reporting with Waveforms & Graphs for R&D & Design Validation • Custom Test Fixtures & Test Programs • Extensive Comm. Support: CAN, LAN/ Ethernet, I2C, PMbus, USB, GPIB, Serial, etc. • Fast & Easy, Excel Like Test Sequence Development • A/B & Parallel Testing for High Volume Applications • Customer Editable Test Library Without Coding • Vendor Qualification & Incoming Inspection • Statistical Reporting • Depot Repair & Failure Analysis • Individual Instrumentation Display Panels & Controls Simplifies Debugging • Supports Complex Inter-Instrument Triggering • Optimized for High Throughput Testing • Dynamically Configurable for R&D Engineering & Design Validation • Command Optimizer Maximizes Test Speed • A/B & Parallel Testing for High Volume Applications • High Volume Production Global Support • Global Operations & Worldwide Support • Depot Repair & Failure Analysis • Local & International Program Management 3 AC Power Sources chromausa.com/instruments/ac-sources Regenerative Grid Simulator: 61800 Designed for PV inverter, Smart Grid and EV related test applications, the 61800 Regenerative Grid Simulator is a full 4 quadrant, fully regenerative, programmable AC power source with advanced features for compliance, safety and product verification testing. Power can both sink and source from the UUT seamlessly to support a multitude of applications. In cases where the UUT sources current, a detection circuit will sense the excess power and recycle it back to the grid. Using stateof-the-art digital control technology the 61800 can deliver up to 300VAC at output frequencies ranging from 30Hz to 100Hz. The AC+DC feature allows for applications that require a DC offset bias. Power rating: 30kVA / 45kVA / 60kVA single or three phase output Full Four-quadrent, Full Regenerative Design Output voltage: 0-300VLN / 0-520VLL Current (+) Unique Features 1 4 V • Full 4 quadrant, fully regenerative up to 100% of output current rating Sink 2 3 • Programmable voltage and current limits Source 1 2 Voltage (-) • Voltage dips, short interruption, voltage variation, phase angle control, etc. 1 • Harmonics, inter-harmonics waveform synthesizer I Source 3 3 • GPIB, RS-232, USB and Ethernet Output Curr. Programmable AC Source: 61500 Voltage (+) 2 Sink 4 4 Reverse Curr. Current (-) Model 61860 The 61500 series defines a new standard in high performance AC power sources. It's equipped with powerful features such as power line disturbance simulation, programmable output impedance, comprehensive measurement functions and optional regulation test software. Power Rating: up to 90kVA, single and three phase Output Voltage: 0-150V / 0-300V Unique Features • Programmable transients for Mil-Std-704, DO-160 and IEC standards • Built-in Harmonics, inter-harmonics and waveform generator • Wide range of models starting at 375VA List Mode: voltage transient programming Model 61512 • Labview graphical user interface including Aerospace standards • GPIB, RS232, USB and Ethernet Distorted Waveform Editor All Programmable AC Power Sources Line Simulation Standard Low Power Standard High Power Advanced Low Power Advanced High Power 61600 61611, 61612 61500 61511, 61512 61800 Power Rating 500VA - 4000VA 12kVA / 18kVA 500VA - 4000VA 12kVA / 18kVA 30kVA / 45kVA / 60kVA Voltage Range 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-300VLN / 0-520VLL Model Frequency Remote Interface Grid Simulator DC, 15Hz-1kHz DC, 15Hz-1.5kHz DC, 15Hz-1kHz DC, 15Hz-1.5kHz DC, 30Hz-100Hz GPIB, RS-232C GPIB, RS-232, USB, Ethernet GPIB, RS-232C (opt) GPIB, RS-232, USB, Ethernet GPIB, RS-232, USB, Ethernet LIST, PULSE, STEP mode functions Programmable voltage and current limit Programmable slew rate setting for changing voltage and frequency Harmonic synthesizer (up to 50) Turn on, turn off degree / phase angle Comprehensive measurement capability, including current harmonics 4 Line Simulation Analog programmable interfaces Optional Optional Graphic User Interface DC Power Supplies chromausa.com/instruments/dc-power-supplies Programmable DC Power: 62000H Chroma’s 62000H Series of programmable DC Power Supplies offer many unique advantages for telecom, automated test system and integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include a high power density of 15KW in 3U, precision read back of output current and voltage and output trigger signals as well as the ability to create complex DC transient waveforms to test device behavior to spikes, drops and other voltage deviations. Power range: 2KW / 5KW / 10KW / 15KW Operating range: 1000V / 375A Unique Features • Master/Slave, parallel and series operation to 150KW with current sharing • High speed transient generator for solar, automotive and aerospace applications • Voltage & Current Slew Rate Control • Labview graphical user interface • GPIB, RS232, USB and Ethernet Model 62150H-40 Solar Array Simulation 62000H-S models have a built in SAS mode that can easily program Voc, Isc, Vmp and Imp parameters to simulate different solar cell materials I-V characteristic outputs with fast response time required for PV Inverter design as well as verification testing. All Programmable DC Power Supplies Constant Power DC Supply Modular - Hot Swappable Programmable High Power Solar Array Simulation (SAS) 62000P 62000B 62000H 62000H-S Power Rating 600W, 1200W, 2400W, 5000W up to 1.5kW per module - up to 120KW per system 5kW / 10kW / 15kW 2kW / 5kW / 10kW / 15kW Voltage Range 0 - 600V 1 - 150V 0 - 1000V 0 - 150V/600V & 1000V up to 2000A (System) 0 - 375A Model Current Range High-speed Programming Precision V&I Measurements Current sharing for parallel operation with Master/Slave Control Ideal for Burn-in & Electrolysis Voltage & Current Slew Rate Control Standard Analog Programming interface Fast transient response solar array simulation Static & dynamic MPPT efficiency test Optional Graphic User Interface 5 Electronic Loads chromausa.com/instruments/electronic-loads Modular Electronic DC Load: 63600 Power Range: up to 2KW, 10 channels (High Power loads: Up to 75KW) Operating Range: up to 1000VDC Unique Features • Voltage and current waveform digitizer on each channel • Unique constant CZ allows for non-linear load simulations • Current down to zero voltage, full current to 0.4VDC • High speed transient generator • Labview graphical user interface • GPIB, RS232, USB and Ethernet Model 63600 - 5 bay mainframe The new generation 63600 DC Electronic Loads provide an innovative Dynamic Sweep mode with Vpk measurements that can be run independently on each module or in parallel for high power loading. Also allows for three measurement ranges for precise voltage and current measurements making it ideal for ENERGY STAR® testing requirements. The 63600 also provides an enhanced feature, User Defined Waveform (UDW), to simulate the actual current profiles and waveforms. Programmable AC Load: 63800 Power Rating: up to 67.5KVA - 3Ph Peak Current: up to 135A Unique Features • High Crest Factor Range: 1.414 to 5.0 • CC, CR, CV, CP for DC loading • Parallel units for higher power and three phase operation • GPIB and RS-232 interfaces Chroma’s 63800 AC/DC load simulates load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform Model 63802 - 4.5KW / 45A / 350V is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results. The 63800 uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load’s control bandwidth to ensure system stability. Designed for testing UPS’s, off-grid inverters, AC sources and other power devices. All Electronic Loads Programmable AC Load High Power DC Load Standard DC Load Advanced DC Load 63800 63200 6310A Modular 63600 Modular Power Rating 1800W/3600W/4500W 2600W, 5200W, 6500W, 10400W, 14500W, 15600W 100W, 200W, 250W, 300W, 600W 100W, 300W, 400W Voltage Range 50V – 350Vrms 0-80V / 0-600V / 0-1000V 0 - 500V 0 - 600V Current Range up to 45Arms up to 1000A up to 240A up to 80A per module Dynamic Loading 45-440Hz 20kHz 20kHz 50kHz Remote Interface Model RS-232, GPIB RS-232, GPIB USB, GPIB & RS-232, Ethernet USB, GPIB, Ethernet Max Channels per Mainframe 1 1 8 10 Master/Slave Parallel Control Synchronize with Multiple Loads Load Modes CC, CR, CP Programmable Slew Rate CC, CR, CV, CP CC, CR, CV, CP CC, CR, CV, CP, CZ LED Array Simulation Constant Impedance Mode V & I Digitizer Analog Input Optional Graphic User Interface 6 Power Meters & Multi Meters chromausa.com/instruments/meters Power Meters: 66204 Multi-Channel Chroma’s 66203 and 66204 Power Meters make accurate power measurements for various wiring modes including three phase WYE and DELTA and split phase. These power meters feature state-of-the-art DSP digitizing technology which replaces less accurate and slower traditional analog circuits. The internal 16 bit analog/digital converters with sampling rates of up to 250 kHz provide both high speed and high accuracy measurements. The meters are designed to comply with power measurement requirements in accordance to many international standards such as ENERGY STAR®, EN 50564, IEC 62301 and ErP. Power Range: up to 600Vrms (1200Vrms opt.) Operating Range: up to 20Arms p/ch (100Arms w/ opt. external shunt) Main screen Unique Features • Embedded high speed DSP, 16 bits Analog/Digital converters • Supports different wiring configurations for power measurement (1P2W/1P3W/3P3W/3P4W) • Dual current shunt design provides high accuracy over a wide current range • 5 mA minimum current range and 0.1mW power resolution • Accumulated energy methods for unstable power measurements • THD and user-specified order distortion measurements • Inrush current and energy measurements • Voltage and Current harmonics measurement up to 50 orders Current harmonic measurement table • Labview graphical user interface • GPIB, RS232, USB and Ethernet Model 66204 - 4 channel Multimeters All Power Meters Model Voltage Range Single Channel Multi-Channel 66201 / 66202 66203 / 66204 150 / 300 / 500 Vrms 15 / 30 / 60 / 150 / 300 / 600 1200 (optional) Vrms 0.01 / 0.1 / 0.2 / 0.4 / 2 / 8 / 20 Arms 0.005 / 0.02 / 0.05 / 0.2 / 0.5 / 2 / 5 / 20 Arms Frequency Range DC, 15Hz-10kHz DC, 15Hz-10kHz Minimum Current Range / Power Resolution 10mA / 0.1 mW up to 2000A (System) Measurement Channels 1 3/4 Meets ENERGY STAR® / IEC 62301 / EN 50564 / ErP Embedded high speed DSP, 16 bits Analog / Digital converters Current Range Dual current shunt design provides high accuracy over a wide current range 66202 only THD and user-specify order distortion measurement 66202 only Inrush current and energy measurements 66202 only Voltage / Current harmonics measurements up to 50 orders Supports various single and 3 phase wiring configurations Optional Graphic User Interface Digital Multimeter Model Resolution 12061 6 ½ Digits DC voltage/current (1000V/3A max) Measurement Characteristics AC voltage/current (750V/3A max) Resistance, 2 or 4 wire ohms measurement, Period & frequency, Diode & continuity, Temperature (Thermocouple & RTD) Math Functions DC Voltage Accuracy AC Voltage Accuracy NULL Max / Min / Avg High / Low limit Percentage / Ratio / MX+B dB / dBm 0.0015% 0.04% Remote Interface USB (standard), GPIB (option) Memory Storage 2000 readings Optional Multi-point TC Scanner Card (10ch), multi-point scanner card (10/20ch) Measurement and data transmission up to 2000 readings/sec (4½) Standard SCPI control Optional Graphic User Interface 7 Safety Analyzers chromausa.com/instruments/hipotsafety Safety Analyzer: 19032 The19032 performs six dielectric tests in one unit including AC/DC Hipot, Insulation Resistance, Ground Bond, Leakage Current and Dynamic Function tests for compliance testing of IEC, UL, TUV, CSA, EN and other standards. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032 also has an open / short check function (OSC) that checks for an open connection or a DUT short during testing. The analyzer’s leakage current scanners can provide up to 20A input current capability for functional run testing as well as earth, patient and line leakage current tests. The analyzer is equipped with programmable limits for pass/fail testing as well as storage and recall of 50 different test setups with 100 steps per setup. Hipot Output Voltage: AC 0.05 - 5kV, DC 0.05 - 6kV 19032 hipot safety analyzer Common Applications Insulation Resistance Test: 0.1MΩ ~ 50GΩ / 1kV Max • Power Supplies, Adapter and Chargers • Video Products (IEC 60065) Unique Features • Home Appliance (IEC 60335) • Lab/Testing Equipment • Six tests in one unit: AC / DC / IR / GB / LC / Dynamic Function • Information Technology Products (IEC 60950) • Electric Vehicle Safety • Optional patient leakage test • Medical Devices (IEC 60601) • EMI Filters • UL / TUV / CE Automate testing by using our CaptivATE software with a Guardian 19032 Safety Analyzer. Test functions include: AC/DC Hipot, insulation resistance, ground bond, earth leakage, patient leakage, patient auxiliary leakage, or enclosure current leakage, as well as a functional check. Provides tests for IEC 60601/60950/61010/60335 requirements. Testing is made simple and fast by automatically downloading the test setup, conducting the required measurements and outputting the test results. Wound Component Safety Analyzer Electrical Safety Analyzer Wound Component Analyzer Guardian19032 / 19032-P 500VA Hybrid 19035 19036 AC / DC / IR / GB / LC / Dynamic Function AC / DC / IR / DCR -8CH AC / DC / IR / Impulse (surge) / DCR 1 8 10 AC: 0.05 - 5kV DC: 0.05 - 6kV AC: 0.05 - 5kV DC: 0.05 - 6kV AC: 0.05 - 5kV DC: 0.05 - 6kV 0.1MΩ ~ 50GΩ / 1kV Max 1MΩ ~ 50GΩ / 5kV Max 0.1MΩ ~ 50GΩ / 5kV Max 4-wire DCR measurement 4-wire DCR measurement, Δ / Y motor winding calculation RS-232 (std) GPIB (opt) RS-232 (std) GPIB (opt), Handler (opt) RS-232, Handler, USB, LAN OSC (Open / Short Check) Flashover Detection GFI (Ground Fault Interrupt) UL/TUV/CE Model Mode (Model Specific) Channels Hipot Test: Output Voltage Insulation Resistance Test Ground Bond Test Leakage / Patient Leakage Test 10mΩ ~ 510mΩ / up to 40A with A190308 Leakage Scanner DCR Measurement Remote Interface Flashover Detection CE mark Impulse Winding Test 8 Wound Component Scanner Hipot Testers & Ground Bond chromausa.com/instruments/hipotsafety Multi-Channel Hipot Tester: 19020 Ground Bond Tester - 45Amp The Guardian 19020 comes equipped with the world’s first sync hipot test function. A single unit can perform 10 channels sync output and measurements simultaneously. Ten units in master & slave configuration can be controlled simultaneously for 100 channels in total. They also can be grouped for output to avoid creating voltage differences due to adjacent tests as well as to improve productivity. The 19572 is an instrument dedicated to measuring grounding resistance within a range of 0.1~510mΩ. Its compact size and easy operation makes it perfect for testing in a production line. Since it supplies highly reliable and stable test results with a built-in resistance compensation function, the 19572 is an economical and useful ground bond tester. • 10 channels per unit - up to 100 channels total Ground Bond Tester 19572 Model High Current Ground Continuity Resistance Measurements Digital Readout up to 45Amps 0.1mΩ up to 45Amps Current, Resistance, Test Time Communication Interface Certification RS-232 (std) GPIB (opt) CE, TUV Programmable high and low resistance limits Adjustable test time Built-in calibration via software Automatic offset of lead resistance Built-in resistance compensation 19020 multi-channel hipot tester All Hipot Testers Model Mode (Model Specific) Channels Standard Hipot Tester Advanced Hipot Tester Hipot Analyzer 500VA High Voltage Hipot Analyzer Multichannel Hipot Tester Sentry 19070 Guardian 19050 Guardian 19055, 19055-C Guardian 19056, 19057 Guardian 19020 AC or AC / DC / IR AC / DC / IR or AC / DC / IR / SCAN AC / DC / IR AC or DC / IR AC or AC / DC / IR 1 1, 8 (opt) 1 1 10 Hipot Test: Output Voltage AC: 0.05 - 5kV DC: 0.05 - 6kV AC: 0.05 - 5kV DC: 0.05 - 6kV AC: 0.05 - 5kV DC: 0.05 - 6kV 19056: AC 0.1 - 10kV 19057: DC 0.1 - 20kV AC: 0.05kV - 6kV DC: 0.05kV - 8kV (models vary) Hipot Test: Cutoff Current AC: 20mA DC: 5mA AC: 30mA DC: 10mA AC: 100mA DC: 25mA 19056: AC 20mA 19057: DC 10mA AC: 10mA DC: 5mA 1MΩ - 50GΩ / 1kV max (19073 only) 1MΩ - 50GΩ / 1kV max 1MΩ - 50GΩ / 5kV max 0.1MΩ - 50GΩ / 5kV max 1MΩ - 50GΩ / 1kV max Remote Interface RS-485 (opt) RS-232 (std), GPIB (opt) RS-232, Handler (std), GPIB (opt) RS-232, Handler, USB, SCAN (std), GPIB (opt) RS-232, Handler (std), GPIB (opt) *CANBUS & DCI used for Max. 10 units master/slave connections Certification CE, UL, TUV CE, UL, TUV (most models) CE CE Insulation Resistance Test Master/Slave link CE Programmable output and limits OSC (Open/Short Check) Flashover Detection GFI (Ground Fault Interrupt) Corona Discharge Detection (19055-C) Ground Continuity Check Fast charge/discharge function Contact Check Function HFCC HVCC, HFCC 9 LCR, IR, and Milliohm Meters chromausa.com/instruments/meters 10MHz LCR Meter with Detached Design: 11050 Milliohm Meters: 16502 • Basic accuracy : 0.05% • Test Parameters: L/C/R/Z/Y/DCR/Q/D/ θ • Pulsed test current output mode to reduce the effect of thermal EMF on milliohm measurement • Test Frequencies: 1kHz ~ 10MHz • DC test current output mode to increase measurement speed for inductive DUT • Test Level: 10mV ~ 5V • Basic Accuracy: 0.1% • Dry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mV In addition to the excellent measurement features shared with other Chroma LCR Meters, the 11050 has 3 output impedance modes to 11050 10MHz LCR meter meet the demands of measuring and working with other instruments. The flexible digital display allows adjustment to best fit the test resolution, while the test signal monitoring function is able to display the voltage and current actually being applied to the DUT. The timing settings for trigger delay, measure delay, and average number of times allow the measurements to work closely with automated machines to get the most accurate results with limited testing time. The detached design of the Chroma 11050 uses a dual CPU system for processing the testing and display individually. This not only increases testing speed but also shortens test lead lengths when used with automated machines to improve the accuracy of high frequency measurements. • Temperature correction (TC function) regardless of material or temperature Digital Milliohm Meter 16502 Model Test Modes DC Mode, Pulse Mode, Dry Circuit Measurement Range 0.001mΩ - 1.9999MΩ with 4 1/2 digits resolution Basic Accuracy Measurement Time Communication Interface 0.05% 65ms - 650ms RS-232 (std), Handler & GPIB (opt) All LCR Meters Model 100kHz LCR Meter Capacitor Leakage Current/ IR Meter 11021 / 11021-L 11022 / 11025 11200 C/D 10MHz LCR Meter 50 kHz LCR Meter 11050 Test Parameters L, C, R, Z, Y, DCR, Q, D, ø Primary: L, C, R, | Z | Secondary: Q, D, ESR, Xs, ø L, C, R, | Z |, Q, D, ESR, X, ø DCR4, M, Turns Ratio, L2, DCR2 (11025 only) Test Frequency 1kHz - 10MHz 100Hz, 120Hz, 1kHz, 10kHz (9.6kHz)(11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz 100Hz, 120Hz, and 1kHz 10mV - 5V 0.25V / 1V (11021) 50mV / 1V (11021-L) 10 mV - 1V , step 10 mV 1V 0.1% 0.1% (11021) 0.2% (11021-L) 0.1% 0.1% Measurement Time 15ms - 295mS 75mS 21mS 2mS ~ 15mS Output Impedance Modes 100Ω, 25Ω, OFF Varies as range resistors 25Ω, 100Ω, 1kΩ, 10kΩ, 100kΩ 2Ω, 10Ω, 25Ω, 100Ω Varies as range resistors Adjustable DC Bias Current 11025 only Compare, Bin-sorting Bin-sorting & HI/GO/LOW judge Bin-sorting & HI/GO/LOW judge HI/GO/LO judge Open/short zeroing & load correction function Zeroing only Detached measurement & display unit design Handler (50pin), GPIB, RS-232 RS-232 (std) Handler & GPIB (opt) Test Levels Basic Accuracy Test Signal Monitoring Function Output Signal Lower Harmonic-distortion affection Remote Interface 10 RS-232C, Handler, USB storage, Ext bias current control (std)GPIB, LAN (opt) RS-232 (std) Handler & GPIB (opt) Data Loggers and TEC Controllers chromausa.com/instruments/thermoelectric Data Loggers: 51101 Data Logger 51101-8 / 8 channel Model Thermocouple/Temperature Accuracy Thermocouple Jacks/Connectors Number of Inputs (Model Dependent) 51101-64 / 64 channel Temperature Sensor Type 51101-1 / single channel Temperature Scale Temperature Resolution Chroma thermal/multi-function data loggers measure temperatures, voltages, and currents with high accuracy and resolutions. For example, they support 8 types of thermal couples measurement with ITS-90 defined temperature range at 0.3°C accuracy and 0.01°C resolution, while most data loggers in the market are at 1°C accuracy and 0.1°C resolution. Chroma loggers provide 1000VDC channel to channel isolation, which means they can attach thermal couples to objects with high voltage, such as batteries, solar cells, working PCB, etc., and still get correct data. Many competitors simply malfunction, or are even damaged in those cases. Chroma loggers use a parallel architecture for data retrieval, while most of our competitors use a sequential multiplexing method. This means data rate per channel is quick and constant for Chroma loggers, while others become much slower as more channels are used. CJC Error Maximum Sample Rate Channel to Channel Isolation Input Resistance Thermocouple break detection current PC Communication Port (Model Dependent) 51101 ±(0.01% of reading +0.3) ˚C B, E, J, K, N, R, S, or T mini-type 1, 8, 16, 24, 32, 40, 48, 56, 64 channel Thermocouple: B, E, J, K, N, R, S, T ITS-90 ±0.01˚C ±0.3˚C 5 sample/sec. 1000VDC / 750 Vrms 5MΩ 100 nA RS-232 Half Duplex (DB-9 connector), USB2.0 (USB A-Type or B-Type connectors) Power Requirement (Model Dependent) 4.5~5.5 V, 11.4~12.6 V Maximum Power Consumption (Model Dependent) 0.22 W, 1.2 W, 18 W Thermal Electric Controllers: 54100 54100 TEC Controller TEC Controller Model 24, 27, or 40VDC TEC Output Current (Model dependent) 8, 12, or 20A TEC Driving Output Power (Model Dependent) Controller Temperature Setting Range (Model Dependent) Chroma’s Advanced TEC Controllers have an excellent temperature monitoring engine, which allows 2 T-type thermal couple inputs. The cold junction of the engine is internally stabilized up to 0.001°C so that 0.01°C temperature resolution and control stability can be achieved. The TEC driver uses a filtered PWM architecture which obtains high driving power efficiency as ordinary PWM drivers, but smoothens the current modulation to a DC-like output; very important for electro-magnetic sensitive measurements. Another important feature is the true TEC PID auto tune function. Chroma’s Advanced TEC Controllers have unique auto tune algorithm to guarantee the best control and temperature response. Stability down to the temperature resolution, which is 0.01°C, is regularly achieved regardless the size and geometry of thermal platforms. 54100 TEC Output Voltage (Model dependent) 150, 300, or 800W -49 to 149° or -70 to 20° Controller Setting Resolution 0.01° Temperature Control Stability Short Term: ≤0.01° Long Term: ≤0.05° Monitoring Temperature Range (Model Dependent) Temperature Sensor Type Monitoring Temp Resolution -49 to 149° or -70 to 20° T-type (Std) K-type (Opt 54180) 0.01° Monitoring Temp Relative Accuracy ≤0.03° Monitoring Temp Absolute Accuracy < ±(0.3+0.002×|T-25|)° Power Requirement Maximum Power Consumption (Model Dependent) PC Communication Port (Model Dependent) 90 to 240 VAC, 50/60 Hz 330, 550, or 1400W RS-232 Half Duplex (54180 only) USB2.0, LAN 10/100Mbps 11 America’s Europe Japan Taiwan / China Chroma Systems Solutions, Inc. | 19772 Pauling, Foothill Ranch, CA 92610 | TEL 949-600-6400 FAX 949-600-6401 | www.chromausa.com CSS 02/2015