Rafael Flores Luminant Power Senior Vice President &

by user

on
Category: Documents
13

views

Report

Comments

Transcript

Rafael Flores Luminant Power Senior Vice President &
Lum inant
Rafael Flores
Senior Vice President &
Chief Nuclear Officer
Luminant Power
P 0 Box 1002
6322 North FM 56
[email protected]
Glen Rose, TX 76043
T 254.897.5590
F 254.897.6652
C 817.559.0403
CP-201100603
Log # TXNB-11028
Ref. #
10 CFR 52
April 25, 2011
U. S. Nuclear Regulatory Commission
Document Control Desk
Washington, DC 20555
ATTN: David B. Matthews, Director
Division of New Reactor Licensing
SUBJECT:
COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 3 AND 4
DOCKET NUMBERS 52-034 AND 52-035
NOTIFICATION OF COMPLETED REGULATORY COMMITMENTS
Dear Sir:
Luminant Generation Company LLC (Luminant) submits herein a table of regulatory commitments that
have been completed during the licensing activities for the Combined License Application for
Comanche Peak Units 3 and 4. These commitments have been made in correspondence to the NRC
submitted by Luminant during the licensing process and have been completed by the documents noted
in the table. The table includes only those commitments that have been completed since the last report
dated January 31, 2011 (ML110330044). Luminant will submit this type of status correspondence
periodically.
Luminant hereby notifies the NRC that Regulatory Commitments #7541 and #7801 have been
completed by the closure documents listed in the attached table.
Should you have any questions regarding these completed commitments, please contact Don Woodlan
(254-897-6887, [email protected]) or me.
There are no new commitments in this letter.
I state under penalty of perjury that the foregoing is true and correct.
Executed on April 25, 2011.
Sincerely,
Luminant Generation Company LLC
Rafael Flores
Attachment: Notification of Completed Regulatory Commitments
U. S. Nuclear Regulatory Commission
CP-201100603
TXNB-11028
4/25/12011
Page 2 of 2
Electronic distribution w/attachment
[email protected]
[email protected]
[email protected]
[email protected]
Brock. [email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
NuBuild Licensing files
Luminant Records Management (.pdf files only)
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
rnutsumni [email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
U. S. Nuclear Regulatory Commission
CP-201100603
TXNB-1 1028
4/25/2011
Attachment
ID #
Source
7541
TXNB-10047
7801
TXNB-10065
NOTIFICATION OF COMPLETED REGULATORY COMMITMENTS
Close Doc
Close Date
Notified NRC
(Question 13.06.01-35) - DCD Subsection 13.6.2.6 will be revised to
provide consistency in the use of backup and standby power.
UAP-HF-11017
1/27/2011
TXNB-1 1028
The supplemental response to RAI 135 Question 12.3-12.4-11 stated: In
the next revision of the DCD currently scheduled for March 2011,
Subsection 9.1.3.2.1.3 will be revised to include the operating experience
discussed in EPRI TR 1013470.
UAP-HF-11046
2/25/2011
TXNB-11028
Description
Page 1 of 1