Comments
Description
Transcript
DuMaster D-480 Technical data sheet
DuMaster D-480 Technical data sheet Routine analysis of nitrogen and protein requires modern instruments that guarantee troublefree and unattended long time operation. As one of the most compact and powerful Dumas analyzer the DuMaster D-480 fulfills these requirements everyday. High sample throughput and flexibility are combined in a unique and effective manner. Featuring the novel Regainer-Reductor system the price per analysis decreases by up to 50 % compared to similar devices. Scope of delivery The scope of delivery consists of the instrument including operating software, 60 position sample plate, as well as all other parts needed for the installation. Additionally, the PC is required to operate the instrument. Apart from copper oxide and the drying agent Sicapent all chemicals required for the initial filling of the tubes are also part of the shipment. The Regainer does not only bind excess oxygen in the analysis gas, but also automatically regenerates the reducing agent being consumed in the course of the process. The lifetime of one combustion tube filling is around 1000 analyses, for the post combustion containing the Regainer 2000 and the pre-filled Reductor tube up to 2000 analyses. Components CD with operating software Qty 1 Data acquisition and evaluation Combustion steel tube 1 Primary combustion, can be refilled Post combustion steel tube 1 Catalytic post combustion tube containing the Regainer, can be refilled Manual pressing tool, D=10.5 mm 1 Preparation of solid samples for the 60 position sample plate Ash crucible, steel 1 For liquids, standard applications, salt containing solid samples Tubing for gas supply 2 Connecting the instrument to the CO2 and O2 supply. Includes the copper tube 3 mm and the tube connector 6 mm to fit on the 2-step pressure regulator. Oxygen lance 1 Oxygen supply to the combustion tube Starter kit chemicals Regainer, 500 g Qty 1 Regainer catalyst to be refilled in the post combustion tube. Lasts for approximately 300 analyses depending on sample’s composition. Reductor 1 Pre-filled Reductor tube, highest lifetime for up to 2000 analyses Set sample packaging 1 Set of different sample boats for sample packaging. Aspartic acid, 100 g 1 Reference sample Platinum catalyst, 30 g 1 Catalyst for post combustion, sufficient for 2 fillings Corundum balls, 50 g 2 Combustion and post combustion tube filling Tin foils Tin foils 50x50 mm, 450 pcs. 1 Starter kit chemicals Qty Brass wool, 50 g 1 Brass wool for the post combustion tube Cotton wool, 50 g 1 Quartz wool, 10 g 1 Order code In addition to the DuMaster D-480 the following chemicals are strictly necessary to fill the tubes when installing the DuMaster and have to be ordered separately: one bottle Sicapent (Order number 11060150) and two packages copper oxide (11060152). 1 1 0 6 0 1 0 0 DuMaster D-480 Dimensions and weight Weight 480 x 570 x 550 mm 65 kg 570 mm DuMaster D-480 Dimensions (WxHxD) Technical data Measuring range up to 500 mg N (or 0 – 100%) Standard deviation < 0.05 % abs. (approx. 250 mg glutamic acid) Detection limit 0.1 mg N absolute Sample amount up to 1 g or 1 mL sample volume Recovery rate > 99.5 % Analysis time approx. ~ 3 - 4 min Sampler Non-stacked 60 pos. (up to 1 g) or 120 pos. (up to 300 mg) with random access Power supply 100 – 230 V +/-10% Frequency 50/60 Hz Power consumption 1500 W Connected electrical load 16 A Protection class IP20 O2 operating pressure max. 2.5 bar CO2 operating pressure max. 1.8 bar O2 gas 99.995 % purity, approx. 0.4 L/analysis CO2 gas 99.995 % purity, approx. 4 L/analysis Ports USB, RS232 Language versions software EN, DE PC requirements Operating system:Windows XP Professional, Windows Vista Business, Windows 7 or Ultimate, Windows 8 Pro or Enterprise, Windows 10 Pro or Enterprise. Hard drive > 15 GB, RAM > 2 GB. Ports: USB to connect the device, USB to RS 232 converter (or RS 232 port) to conncect balance, DVD-ROM drive. Accessories The PC and balance (0.1 mg or 0.01 mg readability) are absolutely needed accessories. Choose any item from this list: Optional parts Order number Software option 21 CFR, 11 11060113 Option to fulfill 21 CFR, part 11 requirements Balance Mettler-Toledo ML54 11060115 Readability 0.1 mg Balance MS105-DU 11061774 Analytical balance, Mettler-Toledo MS105-DU, readability 0.01 mg with V 24/RS 232 interface. Capsule sealing press 11060116 Preparation of liquid samples in tin capsules Sample plate, 120 positions 11062045 Maximum sample amount 300 mg Manual pressing tool, D=7 mm 11060118 Used with 120 position sample plate Sample former with pressing tools D=7 and 10.5 mm Preparation of solid samples wrapped in paper 11060119 Optional parts Order number Reagent kit with chemiclas 11061768 Kit contains items needed for the analysis of up to 4000 samples: 2x Reductor, pre-filled tube. 2x Regainer, 500 g 1x Platinium catalyst 1x Cotton wool 2x Corundum balls 1x Quartz wool 1x Brass wool Note: copper oxide is not included in the reagent kit. It is required to order 3x 11060152 Copper oxide to have all necessary chemicals for analyzing 4000 samples. Check the availability of Sicapent. Conversion kit uninterruptible power supply 11060121 Allows to connect the main board to an uninterruptible power supply Tin foil 11061783 Tin foil for solid samples, 450 pcs., 35 x 35 mm Tin foil cups, pre-formed 11061780 Tin foil pre-formed for solid samples, 100 pcs., 35 x 35 mm Tin foil cups, pre-formed 11061781 Tin foil pre-formed for solid samples, 1000 pcs., 35 x 35 mm Tin foils 50 x 50 mm, 450 pcs. 11060125 For preparation of wet, oily or fatty solid samples Tin capsules for liquid samples, 0.3 mL 11060126 Size 6.75 x 14 x 0.1 mm, 100 pcs. Tin capsules for liquid samples, 0.5 mL 11060127 Size 8 x 20 x 0.2 mm, 100 pcs. Set wear parts 11060129 Comprehensive set of wear parts (joints, filters and seals) for fast and easy maintenance Convenience kit 11061769 Allows faster tube exchange during routine work Kit contains: 1x Reductor 1x Combustion tube 1x Post combustion tube 2x Oxygen lances 1x Quartz glass bridge 1x Drying tube 1x Glass tube 1x Ash crucible, steel 1x Wire mesh, D=22 mm 2x Spacer, D=23.5 mm 1x Wire mesh, D=26.8 mm Ash crucible, steel 11061763 For liquids, standard applications, salt containing solid samples Combustion tube, steel 11061764 Steel combustion tube for DuMaster Consumables Order number Regainer 11061765 Regainer catalyst to be refilled in the post combustion tube. Lasts for approximately 300 analyses depending on the sample’s composition, 500 g Consumables Order number Reductor 11061767 Reduction tube, pre-filled, highest lifetime for up to 2000 analyses Set sample packaging 11060139 Set of different sample boats for sample packaging Platinum catalyst, 30 g 11060149 Catalyst for post combustion, sufficient for 2 fillings Drying agent (SICAPENT®)* 11060150 Sicapent drying agent (P2O5 with indicator), 2.8 L bottle Copper oxide wire, 250 g* 11060152 Combustion and post combustion tube filling Wire mesh, D=22 mm 11060154 Used in the post combustion tube, 1 piece Wire mesh, D= 26.8 mm 11062143 Wire mesh used for the combustion tube, 1 piece Corundum balls, 50 g 11060157 Combustion and post combustion tube filling Aspartic acid, 100 g 11060158 Reference substance Brass wool, 50 g 11061766 Brass wool for the post combustion tube Cotton wool, 50 g 11060153 Quartz wool, 10 g 11061782 Quartz wool for the post combustion tube Standard calibration set DuMaster D-480 11062153 1-650 mg aspartic acid * These chemicals are not included in the scope of delivery and have to be ordered separately. Qualification documents Order number DuMaster D-480 IQ/OQ Documentation 11060160 Official documentation for the first installation and operation qualification. Conducted by an authorized service engineer DuMaster D-480 Repeating OQ Official documentation for the annual operation control. Conducted by an authorized service engineer 11060161 Functional principle The Dumas method for nitrogen determination is based on quantitative combustion in excess oxygen. Nitrogen from the sample is transformed to molecular nitrogen. The novel Regainer catalyst binds excess oxygen in the analysis gas without any need of reduction metals and regenerates the consumed reducing agents in the Reductor. In the pre-filled Reductor tube the nitric oxides are reduced to nitrogen while the reduction agent is automatically regenerated. After condensation and 3-step drying, the carrier gas CO2 transfers the analysis gases to the thermoconductivity detector (TCD) and nitrogen gives a signal which is displayed as a peak. The instrument software calculates the nitrogen content by integrating the peak area. For the calculation of the protein concentration generally accepted protein factors are used. The DuMaster D-480 features an automatic at-the-spot oxygen injection for the combustion which saves up to 95 % oxygen. A sampler that accommodates 60 (optionally 120) samples without stacking, in connection with unique blank-free ball valve injection guarantees absolute stable round-the-clock operation. By analysing the whole gas stream without splitting, sensitivity is increased. The carrier gas (CO2) eliminates the need to absorb CO2 generated during the combustion process. The novel Regainer-Reductor system allows for approx. 2000 analyses without exchange or maintenance and minimizes down times remarkably. F4 P2 94 V16A Mess 2 1 16 2 1 18 61 62 74 71 Ref 29 2 V16B 72 V6 4 63 1 63 73 F3 2 216 1 8 8 60 27 33 70 78 F1 59 67 69 68 2 58 1 3 2 V4 V7 O2 Funktionssymbole functional icons P1 1 2 61 CO 2 32 Zweiwegeventil two way valve Flusssensor flow sensor Verbrennung combustion Dreiwegeventil three way valve Drucksensor pressure sensor Nachverbrennung post combustion Rückschlagventil check valve Loop loop Reduktion reduction Rohr copper tube Drossel throttle beheizte Leitung heated tube Gastrennung gas seperation Schlauch plastic tube Flussregler mass flow controller Trocknung gas drying Messzelle detector cell www.buchi.com/protein Basis Symbole basic icons Filter filter Sensor sensor Aktuator actuator Glas glass Quality in your hands 11595200A D-480 Data Sheet en 1603 / Technical data are subject to change without notice / Quality Systems ISO 9001 The English version is the original language version and serves as basis for all translations into other languages. CS46