EndoGear3 Ordering Information Telemetry ENDOGEAR BASE STATION
by user
Comments
Transcript
EndoGear3 Ordering Information Telemetry ENDOGEAR BASE STATION
Telemetry EndoGear3 Ordering Information ENDOGEAR® BASE STATION A complete EndoGear® system consists of a Base Station, one or more Remote Transceivers and an Implant. The Implant requires a Battery Power Module and a combination of Velocity, Pressure or ECG Sensors. There may be up to 2 channels of Velocity and 2 channels combined of Pressure and ECG. The RF frequency band of the Implant must match the Transceiver. EG108 REMOTE TRANSCEIVERS REGION MONOPOLE PLANAR FREQUENCY BAND Japan EG-RM-M22 EG-RP-M22 200 - 399 MHz US, CA, EU, NZ, AU, CHN EG-RM-M23 EG-RP-M23 400 - 599 MHz US, CA, EU, NZ, AU, CHN, JP EG-RM-M25 EG-RP-M25 800 - 999 MHz ENDOGEAR® IMPLANT Catalog #: EG3 - V TRANSCEIVER SPLITTERS* EG-RTS-M22 Expands Transceiver Range EG-RTS-M23 EG-RTS-M25 # Biometric Channels (0-2) DOPPLER FLOW VELOCITY PROBES EG-VPB0.7-x EPIVASCULAR EG-VV-x EG-VPB1.0-x ENDOVASCULAR COMBINED ENDOVASCULAR & PRESSURE EG-VE1-x (size: 1F) EG-VEPR1-x (size: 1F) EG-VE3-x (size: 3F) EG-VEPR3-x (size: 3F) Built-in Temperature RF Frequency Band to Match Transceiver (M2x) PRESSURE SENSORS (BIOMETRIC) EG-VPB1.5-x CATALOG # EG-VPB2.0-x EG-VPB2.5-x EG-VPB3.0-x EG-VPB3.5-x CATHETER SIZE LENGTH (CM) EG-SPS1-x 1F specify EG-SPS3-x 3F specify ECG SENSORS (BIOMETRIC) For all, specify cable length in cm. EG-VPB4.0-x T - M2 # Velocity Channels (0-2) EndoGear® Series *Match to Transceiver Frequency Band (M2x) PERIVASCULAR S EG-SC2-x EG-VPB5.0-x (small gauge ECG leads, specify length) EG-VPB6.0-x EG-VPB7.0-x EG-VPB8.0-x BATTERY POWER MODULES VOLUME (CC) CAPACITY (AMP HRS) CABLE LENGTH (CM) BATTERY SIZE ESTIMATED HOURS OF CONTINUOUS USE EG3-P4CP-1.2 4 1.2 5 1/2 AA 100 - 150* EG3-P10CP-2.4 10 2.4 5 AA 200* EG3-P15CP-3.6 15 3.6 5 A 300* CATALOG # * Dependent on configuration. THROUGH-SKIN POWER OPTIONS EG3-WPR (Wireless power receiver for EG3 Implant) EG3-WPS (Wireless power supply for rodent cage) EG-3-ds Rev. A 4/14 EG3 Implant with antenna, perivascular probe, pressure sensor, ECG, and wireless power receiver EndoGear3 Signals & Component Specifications SYSTEM SIGNALS IMPLANT (EG3-VxSxT-M2x) Flow Velocity Channels: Configurable; up to 2 Case Volume (without connectors): Biometric Sensor Channels: Configurable; up to 2 • 3.5 cc; 28 mm L x 30 mm W x 9 mm D Temperature Channel: 1 Sensor embedded in Implant Weight: 8 grams Reference Barometric Pressure: 1 in Base Station Power Consumption (maximum configuration): Signal Sampling Rate (all channels): 200 Samples/sec • Sleep: 1.8 mAmp DOPPLER FLOWMETER Ultrasound Frequency: 20 MHz Pulse Repetition Frequency: 64 kHz maximum Range Gate Adjustment Limits: 0.7 - 8 mm in 0.7 mm increments Doppler Frequency Shift Measured: ± 20 kHz Blood Velocity Range: ± 120 cm/sec. Perivascular Cuff Probes: 0.7 - 8 mm vessel diameter Piezoelectric Doppler Transducer: 1 mm diameter BLOOD PRESSURE Range: -50 to +300 mmHg Intravascular Pressure Sensor: • On: 11 mAmp Battery Power Module: Lithium-thionyl chloride; sizes A: 3.6V, AA: 2.4V or 1/2AA: 1.2V (disposable, nonrechargeable) Wireless Power Supply & Receiver: No battery needed. Induction coil attached to Implant. BASE STATION Dimensions: 10.75” L x 10” W x 3.2” D Weight: 4 lbs. Electrical Power: 9 VDC Analog Output Signal Range: 0 - 5 volts; all channels Storage Temperature: -10 to +60°C; ≤ 90% humidity Operational Temperature: 0 - 40°C • 1 French (0.3 mm dia) RF TRANSCEIVER • 3 French (1 mm dia) Multichannel RF Bands (country specific): ECG Input Impedance: ≥ 10 MΩ Signal Band: 0.5 - 50 Hz • M22: 200 - 399 MHz • M23: 400 - 599 MHz • M25: 800 - 999 MHz Range (environmental dependent): TEMPERATURE • Monopole: 3 - 6 meters; 1 meter challenged Temperature Range: 15 - 50°C • Planar: 1 - 3 meters; 20 - 50 cm minimum Resolution: 0.0625°C Base Station and Transceiver Wireless power supply for rodent cage www.transonic.com