...

PRICE BID CORPORATE OFFICE - MEHSANA

by user

on
Category: Documents
22

views

Report

Comments

Transcript

PRICE BID CORPORATE OFFICE - MEHSANA
CORPORATE OFFICE - MEHSANA
PRICE BID
NAME
OF
WORK:
Sr.No.
1
CONSTRUCTION OF DIVISION OFFICE-HIMATNAGAR,SUB DIVISION OFFICES FOR
HIMATNAGAR (TOWN) AND MEHTAPURA AT HIMATNAGAR CIRCLE OFFICE CAMPUS.
Description
PART A - CIVIL WORK
Providing and applying anti termite treatment, as per IS
6313 (part II & part III 2001) for building works in pre
construction & post construction stages, using chemicals
conforming to relevant IS in water emulsion and effective
when aopplied uniformly over the area to treated. The
chemical to be used is chloro-pyriphos 20% EC or its
equivalent. The treatment is to be carried out as per the
procedure mentioned below and treated plinth surface
area is to be taken for measurement.
Qty
900.0
Unit
SMT
Rate
60.50
3
4
5
6
Excavation for foundation up to 1.5 mtr. Depth including
sorting out & stacking of useful materials & disposing off
the excavated stuff up to 50 meter lead. (a) Loose or soft
soil
Excavation for foundation for depth from 1.5 Mt to 3 Mt.
depth including sorting out and stacking of useful
materials and disposing of the excavated stuff upto 50Mt.
lead.(a) Loose or soft soil
Filling available excavated earth ( excluding Rock ) in
trenches, plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each deposited
layer by ramming & watering.
Filling in foundationand plinth with murrum or selected
soil brought from outside in layer of 20cm. including
watering ramming and consolidating etc. complete.
Filling in plinth with sand under floors including watering,
ramming, consolidating and dressing etc. complete.
Page 1 of 23
54450.00
0.00
For pre cons treatment:
For plinth filling & periphery holes in side plinth to be
drilled 300mm C/C each having depth 1.5 M and for inside
plinth the holes are to be treated with diluted chemical
solution, 1.5 Lit. per hole, in the ratio of 1:20. The entire
surface area is to be treated with diluted solution 2.25 M
per Rmt. In the ratio 1:20. The entire surface area is to e
treated with diluted solution of dose 2.5 Litres per Smt.
over and above as a plinth surface treatment.
2
Amount
460.0
CMT
75.00
34500.00
250.0
CMT
83.00
20750.00
520.0
CMT
48.30
25116.00
300.0
CMT
289.00
86700.00
185.0
CMT
625.00
115625.00
Sr.No.
Description
7
Providing & laying Cement concrete 1:4:8 ( 1 cement
:4Coarse sand : 8 machine crush metal aggregate
40mm.nominal size ) and curing complete excluding cost
of form work in (a) Foundation and plinth
8
Providing & Laying cement concrete M-200 and curing
complete excluding the cost of form work in (A)
Foundations, footings of column & mass concrete.
9
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in Beams Having cross sectional area more
than 0.08 Sq. M. and up to 0.12 Sq.M.
10
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in (B) Columns. Upto floor 2 levels
11
12
13
14
ii) Having cross sectional area more than 0.08 Sq.M. & up
to 0.12 Sq.M.
iii) Having cross sectional area more than 0.12 Sq.M. & up
to 0.18 Sq.M.
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in (B) Columns. Above floor 2 levels
ii) Having cross sectional area more than 0.08 Sq.M. & up
to 0.12 Sq.M.
iii) Having cross sectional area more than 0.12 Sq.M. & up
to 0.18 Sq.M.
Providing & laying CEMENT CONCRETE IN M-200
including the cost of necessary formwork, compacting
with vibrator, curing & shuttering in true line and level etc.
but excluding cost of reinforcement in RCC work for
COPINGS for any type of cross sectional area... etc.,
completed as directed by E.I.C.
Qty
208.0
Unit
CMT
Rate
2496.00
Amount
519168.00
170.0
CMT
4246.00
721820.00
20.0
CMT
6211.00
124220.00
1.0
CMT
7239.00
7239.00
33.0
CMT
6371.00
210243.00
1.0
CMT
7276.90
7276.90
22.0
CMT
6408.90
140995.80
13.0
CMT
4300.00
55900.00
15
Providing & Laying cement concrete M-200 for R.C.C. lintel
including finishing smooth with curing etc. complete
including the cost of form work but excluding the cost of
reinforcement. Upto floor two level
10.0
CMT
7045.00
70450.00
16
Providing & Laying cement concrete M-200 for R.C.C. lintel
including finishing smooth with curing etc. complete
including the cost of form work but excluding the cost of
reinforcement. Above floor two level
10.0
CMT
7082.90
70829.00
17
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in Beams
(3) Having cross sectional area more than 0.12 Sq. M. and
up to 0.18 Sq.M.
70.0
CMT
5645.00
395150.00
Page 2 of 23
Sr.No.
Description
18 Extra for additional lift of concrete for all R.C.C. work
Qty
Unit
Rate
Amount
(3) Having cross sectional area more than 0.12 Sq. M. and
up to 0.18 Sq.M.
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in (II) slab having more than 10cm & up to
13cm. thickness. Upto floor two level
48.0
CMT
5682.90
272779.20
78.0
CMT
5698.00
444444.00
20
Providing & Laying cement concrete M-200 and finishing
smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforcement for
R.C.C. work in (II) slab having more than 10cm & up to
13cm. thickness. Above floor two level
72.0
CMT
5735.90
412984.80
21
Providing & Laying cement concrete M-200 for Reinforced
concrete Chhajjas not exceeding 10cm. thickness up to
floor two level including finishing the exposed surfaces
with cement mortar 1:3 ( 1 Cement : 3 fine sand ) to give a
smooth & even surface centering and form work and
curing complete excluding the cost of reinforcement.
Upto floor two level
2.0
CMT
6058.00
12116.00
22
Providing & Laying cement concrete M-200 for Reinforced
concrete Chhajjas not exceeding 10cm. thickness up to
floor two level including finishing the exposed surfaces
with cement mortar 1:3 ( 1 Cement : 3 fine sand ) to give a
smooth & even surface centering and form work and
curing complete excluding the cost of reinforcement.
Above floor two level
2.0
CMT
6095.90
12191.80
23
Providing thermo Mechanically treated bars (TMT BARS) 39000.0
confirming to IS 1786 / FC 415 for R.C.C. works including
bendings, binding & placing in position complete upto
floor two level.
Extra for additional lift of reinforcing steel of all R.C.C. 18500.0
work above floor two level.
Brick work using common burnt clay building bricks having
110.0
crushing strength not less than 35 Kg./ sq.cm. in
foundation & plinth in cement mortar 1:6 ( 1 cement : 6
Fine sand )
(B) Conventional
Brick work using common burnt clay building bricks having
125.0
crushing strength not less than 35 Kg./ sq.cm. in Super
structure above plinth level upto floor two level in cement
mortar 1:6 ( 1 cement : 6 Fine sand )
(B) Conventional
KG.
56.30
2195700.00
KG.
56.80
1050800.00
CMT
3205.00
352550.00
CMT
3308.10
413512.50
CMT
3339.30
484198.50
19
24
25
26
27
Brick work using common burnt clay building bricks having
crushing strength not less than 35 Kg./ sq.cm. in Super
structure above floor two level in cement mortar 1:6 ( 1
cement : 6 Fine sand )
(B) Conventional
Page 3 of 23
145.0
Sr.No.
Description
28 Half brick masonary in common burnt clay building bricks
having crushing strength not less than 35 Kg./Sq.cm. in
cement mortar 1:4 (1cement :4 coarse sand) in super
structure above plinth level up to floor two level. With
CONVENTIONAL BRICKS
29 Half brick masonary in common burnt clay building bricks
having crushing strength not less than 35 Kg./Sq.cm. in
cement mortar 1:4 (1cement :4 coarse sand) in super
structure above floor two level. With CONVENTIONAL
BRICKS
30 Providing 15mm. Thick cement plaster in single coat on
brick/concrete wall for interior plastering up to floor two
level finished even and smooth in (i) Cement mortar 1:3 (
1 cement :3 sand) incl. finishing with a floating coat of
neat cement slurry.
31 Providing 15mm. Thick cement plaster in single coat on
brick/concrete wall for interior plastering above floor two
level finished even and smooth in (i) Cement mortar 1:3 (
1 cement :3 sand) incl. finishing with a floating coat of
neat cement slurry.
32 20mm. Thick sand faced cement plaster on walls up to
height 10 meters above ground level consisting of 12mm.
Thick backing coat of C.M. 1:3 ( 1 cement : 3 sand ) and 8
mm. thick finishing coat of C.M. 1:1 (1 Cement :1 sand)
etc.. Complete.
33 Providing and fixing window having extruded alluminum
colour powder coated section frame main outer size
63.5x38.10x1.95mm (of Jindal Section no4605,@ wt 1.094
Kg/Rmt), horizantal two/three track member size
61.85mmx31.75mmx1.20mm (of Jindal section no 8687 @
wt
of
0.695kg/Rmt),
vertical
memberof
size
61.85mmx31.75mmx1.30mm (of jindal section no 8758 @
wt of 0.659kg/mt) with sliding shutter of horizantal
member size 40mmx18mmx1.29mm (of jindal section no
8949 @ wt of 0.456kg/Rmt), vertical member of
size40mmx18mmx1.29mm (of jindal section of 8947 @ wt
of 0.456kg/mt, section 8948 @ wt of 0.457kg/mt) with
5mm thick transparent bronze colour tinted float glass
with powder coated alluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
details etc complete.
Page 4 of 23
Qty
240.0
Unit
SMT
Rate
460.80
Amount
110592.00
172.0
SMT
465.20
80014.40
2310.0
SMT
150.20
346962.00
1575.0
SMT
158.50
249637.50
1230.0
SMT
208.90
256947.00
96.0
SMT
2471.00
237216.00
Sr.No.
Description
34 Providing fitting & fixing fully glazed/ partly glazed double
leaf anodised aluminium entrance door using extruded
section fabricated by standard manufactures with framing
10.15cm x4.45cm rectangular section & door shutter
made from 10.15 cm x 4.45cm aluminium bottom section
top & vertical section 6.35x3.80cm size using 5.5mm thick
"Triveni"or HB4 smoke glass with glazing deep rubber
gasket with locking arrangement(Godrej type) with all
fixtures & fastenings of anodised section with
aluminium bedding, hydraulic door closer with all labours
& materials etc. Complete as per drawing and as directed
by E.I.C..Item also includes powder coating to alluminium
sections of approved colour / shade incl. all
materials,labour,tools & tackles etc. complete.
Qty
34.0
Unit
Sq.M.
Rate
2970.00
Amount
100980.00
35
Providing fitting & fixing fully glazed/ partly glazed double
leaf anodised aluminium entrance door using extruded
section fabricated by standard manufactures with framing
10.15cm x4.45cm rectangular section & door shutter
made from 10.15 cm x 4.45cm aluminium bottom section
top & vertical section 6.35x3.80cm size using 5.5mm thick
"Triveni"or HB4 smoke glass with glazing deep rubber
gasket with locking arrangement(Godrej type) with all
fixtures & fastenings of anodised section with
aluminium bedding floor spring mounted double door
closer with all labours & materials etc. Complete as per
drawing and as directed by E.I.C..Item also includes
powder coating to alluminium sections of approved colour
/ shade incl. all materials,labour,tools & tackles etc.
complete.
29.0
Sq.M.
3190.00
92510.00
36
Providing and fixing PVC door frame of size
48X40X1.80MM thick for PVC door with inserting country
wood in hollow part with approved size of corner,
necessary hole fast & grouting in wall etc. complete as
directed. ( Measurement will be paid for width out to out
without horns and height from floor top surface to top of
frame. Item to be used for W/C and bath only.)
28.0
SMT
632.50
17710.00
37
Providing and fixing PVC door shutter in single or double
leaf of 20mm thick with shutter outer frame top bottom
and style of size 54 X 24 X 1.80mm thick and locking rail
ara of size 100 X 24 X 1.80mm thick panels are made from
PVC section 200 X 20 X 1mm thick including fixing & joints
with providing 3 Nos. of 100 mm long hinges on each flap
of door including fixing with frame. The material is f
approved ISI brand colour & tint as per drawing &
instruction of E.I.C. ( To be used for bath & W/C only.
Measurement shall be paid for clear size of shutter only.)
26.0
SMT
1237.50
32175.00
Page 5 of 23
Sr.No.
Description
38 Providing & laying colour glazed tiles 6mm. Thick in
flooring, treads of steps & landing laid on a bed of 12mm.
Thick cement mortar (1:3) (1 cement : 3 coarse sand
finished with flush pointing in white cement.
39
40
41
42
43
Providing & laying colour glazed tiles 6mm. Thick in
skirting,risers of steps & dedo on 10mm. Thick cement
plaster (1:3) (1 cement : 3 coarse sand finished with flush
pointing in white cement.
Providing and laying vitrified tiles 8 mm. Thick in flooring
treads of steps and landings,skirting etc. laid on a Bed of
20 mm. Thick cement mortar 1:6 (1 cement : 6 coarse
sand) pointing in white cleaned jointed with white cement
slurry.Light shade
Providing & Fixing China Mosaic Tiles flooring as water
proofing treatment including (a) Applying Cement slurry of
cement mixed with water proofing compound after
cleaning the surfaces properly.(b) Cracks in slab shall be
open in "V" groove & all materials shall be removed &
approved type of expanding crack fillet material. (c)
Depression in slabif any be filled up with C.C. (1:2:4) I.P.S.
Flooring.(d) P/L 20mm thick plaster layer in C.M (1:4) with
cement admixed with water proofing compound including
rounding of junction of walls and slabby making cement
vatta. (e) Finishing the surface with china mosaic tiles
(pieces) flooring incl. fixing the samein cement mortar
(1:2) setting with ready made tile adhesive as
recommended by manufacturer's including filling of joints
mixed with pigment white slurry of matching.(f) after
finishing the whole terrace shall be flooded with water to
check the performance of work.
Distempering (two coats) with oil bound distemper of
approved brand & manufacturer & of required shade on
wall surfaces to give an even shade, over & including a
proming coat with a distemper primer of approved brand
& manufacture after throughly brushing the surface free
from mortar droping & other foreign matter & also
including preparing the surface even & sand papered
smooth.
Item also includes Applying two coats of Birla or Asian
acrylic lappy (putty) and two coats of primer of approved
brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand
papered smooth.
Providing & applying 2 coats of APEX or its equivalent
AACRYLIC EXTERIOR paint on exiting plastered surface or
approved makes & shade including finishing & thining as
per manufacturer’s instruction. A gap of 6 hrs. should be
given between 2 subsequent coats. The work should be
carried out strictly as per manufacturer’s specifications
and requirement etc., complete as directed by E.I.C.
Page 6 of 23
Qty
120.0
Unit
SMT
Rate
760.00
Amount
91200.00
300.0
SMT
916.00
274800.00
920.0
SMT
1007.00
926440.00
681.0
SMT
377.00
256737.00
3885.0
SMT
89.60
348096.00
1230.0
SMT
72.00
88560.00
Sr.No.
Description
44 providing and fixing 12.5 mm thick gypsum board
suspended false ceilling including provoding and fixing of
perimeter channels G.I. hings all joints finished with joint
filler as recommonded by manufacture ( india Gypsum)
including making opening holes for various fittings
Qty
120.0
Unit
SMT
Rate
647.00
Amount
77640.00
45
Providing and laying Black granite for entrance
steps,water counter etc. flooring over 20 mm. (average)
base of cement mortar 1:6 (1 cement : 6 coarse sand) or
L.M. 1:1.5 and jointed with grey cement slurry including
rubbing and polishing cimplete.
16.0
SMT
3198.00
51168.00
46
Providing 2500mm internal diameter and 5.0 mt. deep
soak pit including excavation in all types of soil and soft
rock and BBCC (1:4:8) bedding 300mm thick below
masonry and 450mm thick B.B. masonry in C.M. (1:6) up to
1000mm height 350mm thick for further 1000mm and
230mm thick for the remaining height and 100mm thick
R.C.C. slab with 600x600mm C.I. heavy cover with frame
with necessary reinforcement as per design and C.I. vent
pipe 1800mm long with B.B. masonry pillar
350x350x450mm plastered all around filling 40 to 50mm
size brick bats up to 1.5 metre depth including 16mm dia.
M.S. 'U' stage steps refilling etc. Complete as directed and
including disposing off the surplus excavated earth up to
lead of 300 metre radius including 3 coats of white or
colour wash to all exposed finished surface etc. Complete
as directed by E.I.C., Rate is inclusive of cement & Steel
cost.
1.0
NO
33964.00
33964.00
47
Steel work welded in built up sections,framed work
including cutting, histing, fixing in position and applying a
priming coat of red lead paint
(A) In beams and joints channels angles, tees, flats with
connecting cleats as in main and cross beems, hip and jack
reffers, purlins connected to common raffers and the like.
6875.00
928125.00
48
Painting two coats (including priming coat) on new steel
and other metal surfaces with enamel paint, brushing
interior to give an even shade including cleaning the
surface of all dirt, dust and othr foreign matter.
1350.0
SMT.
83.20
112320.00
49
Providing corrugated G.I. Sheets roofing fixed with
Galvanied iron 'J' or 'L' hooks bolts and nuts 8 m. diameter
with bitumen and G.I.Limpet washers filled with white lead
complete excluding the cost of purlins, raffers and trusses.
(I) 0.80 mm. Thick sheet
450.0
SMT
892.00
401400.00
Page 7 of 23
135.0 Quintel
Sr.No.
Description
50 Demolition of existing building (Old Quarters / Toilet
Blocks / Office Building / Overhead Water Tank etc.) incl
dismentalling of brick masonary , reinforced or plain
cement concrete work , sheet , roofng with purlins/ rafter,
flooring doors / windows etc incl removal; of masonary
from foundation & refilling the trenches thereof which are
not usable of new construction, item including carrying
out of all the building materials against demoliation job of
existing building at his cost & risk etc complete as directed
Qty
1211.0
Unit
SMT
Rate
0.00
Amount
0.00
51
Providing and making Glass wall / Glass brick as per detail
drawing as requied, and as per approval of architect. Cost
includes handles, floor spring etc for two nos double doors
and also, required patch fittings / supprots as required.
40.0
SMT
4400.00
176000.00
52
Providing and making SS Railing as per detail drawing
including welding, fixing etc
Labour charges for making moulding edge to Black granite
incl. all tools,tackles etc. complete as directed.
30.0
SMT
2500.00
75000.00
50.0
RMT.
120.00
6000.00
Labour charges for Moulding edge to Kota stone etc
complete.
Providing cement vata (10cm X 10cm. Size) quarter round
in cement mortar 1:1 including neat cement finishing,
watering etc.. Complete.
Providing Fixing 25mm. thick POLISHED KOTAH STONE wall
partitions 600mm. wide & required height & all sides
polished, machine cut & of approved quality including
fixing the same in wall in line & level etc., complete as
directed by E.I.C.
Supplying and filling cinder fiiling to toilet sunk, including
loading , unloading and conveying on site with required
filled up cinder compecting light weight material
completed in level at any floor
Providing & Laying Water Proofing Treatment in Sunken
Portion of W.C., Bathroom etc. by applying Cement Slurry
mixed with water proofing chemical ,as per
manufacturer's specifications of approved make as under.
90.0
RMT.
90.00
8100.00
150.0
RMT.
20.20
3030.00
15.0
SMT.
828.00
12420.00
9.0
CUM
3400.00
30600.00
20.0
SMT
395.00
7900.00
195.0 Cu.mt.
75.90
14800.50
93.0 Cu.mt.
182.00
16926.00
186.0 Cu.mt.
758.91
141157.26
53
54
55
56
57
58
59
60
61
Box cutting the road surface to proper slop and chamber
for making a base of road work including removing the
excavated stuff and depositing on the road side slope as
directed upto50 mts, lead.
Earth work in cutting including preparing the slope and
chamber and stacking ar utillising the cutting stuff in bank
as directed upto 200 meters from the endof cutting with
all lead and lift.
(I) Hard murrum
Supplying of graded stone aggregate of following sizes (for
W.B.M.road)
(1) hand broken stone aggregates 63 mm to 40 mm size
Page 8 of 23
Sr.No.
Description
62 Spreading the stone aggregates for soling and W. B. M.
including filling the interstices forming the surface to
required camber and gradient
(ii) 40 mm to 63 mm size aggregates (HB)
63 Supplying of murrum /binding material
Qty
Unit
Rate
Amount
186.0 Cu.mt.
99.00
18414.00
49.0 Cu.mt.
225.98
11073.02
49.0 Cu.mt.
930.0 Sq.m.
59.10
13.00
2895.90
12090.00
64
Spreading blindage Murrum filling the gaps in metal and
levelling to camber and gradient as directed.
65
Rolling and consolidating water bound macadum (execept
laterite and kunkar ) including watering not exceeding 150
mm. thickness (main layer including binding materials)
including filling in depressing which occur during the
process with power roller exceeding 8 tone but not
exceeding 12 tone
66
P/F pre - cast rubber dye inter locking concrete block
60mm thick with grade of concrete M-200 pnumatic
compressed by mechanically pressed and as per approved
design including 75 mm sand layers for leveling and filling
the jiont with sand in proper line and level etc completed .
450.0
SMT.
570.00
256500.00
67
Providing and laying cement concrete pavement for road
with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm. Nominal size) including finishing with
floating coat of neat cement.
Carring out cement concrete work for road pavement by
trimix ( vacume dewatering service ) process by using
vacume dewatering equipment / pump & floater disc
surface vibrator etc incl. proper vibration / compaction &
anti skid surface finish of concrete pavement incl. Making
groove in it incl. all tools,tackels,materials, labour etc.
complete as directed.
95.0
CMT.
3766.00
357770.00
930.0
SMT.
65.00
60450.00
68
69
Providing , supplying & fixing pre cast concrete Kerb stone
of grey cement base based concrete block having size of
300 *75 *300 mm depth of M-250 grade concrete as per
approved design and including excavation for fixing in
proper line and level filling the jiont with C.M.1:3 ( 1;
cement :3 sand ) etc complete
250.0
RMT
145.00
36250.00
70
Cleaning out grooves provided in concrete road pavement,
wetting, grouting with cement and sand slurry 1:3 and
curing etc incl.all materials & labour etc complete as
directed.
Providing and laying (two level or slopes) and jointing
reinforced concrete light duty, nonpressure pipes I.S> class
NP/2 of the follwing internal diameter with collars and
butt ends prepared for collar joints including testing of
units complete.
(C) 250 mm.
150.0
RMT
26.90
4035.00
60.0
RMT
275.00
16500.00
71
72
Providing / Fixing venetion blinds curtains of
approved brand,make,colour shade & pattern etc.
complete as directed by E.I.C.
90.00
Page 9 of 23
Rmt
645.00
58050.00
Sr.No.
Description
Qty
73 Providing & applying Dr.fixit( pidilite)LW+ In RCC Work 232.00
Unit
Rate
Amount
Litre
78.00
18096.00
for Better concreting of 200ml per bag as directed &
instructed by E.I.C
TOTAL OF PART - A CIVIL WORK
74
75
76
77
78
79
80
81
82
83
84
85
86
PLUMBING WORK
(I) External Drainage System:Providing and laying (Two level or slopes) and jointing with
stiff mixture or cement mortar in proportion 1:1, salt
glazed stone ware pipes following nominal intrnal
diametre including testing of pipes and joints etc.
complete.
(A) 100 mm dia.
(B) 150 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm. Nominal
size) bending for stone- ware pipes of following internal
diametres with necessary form work and curring
complete.
(A) 100 mm dia. (112 mm. Average bed thickness)
(B) 150 mm dia. (116 mm. Average bed thickness)
Extra over item 74-A-B for providing salt glazzed stone
ware fittings
(I) Bends of required Degree (any radius) of following
internal diameters
(A) 100 mm dia.
(B) 150 mm dia.
Taper bend of required degreeof folowing - internal
diametres
(A) 100 mm x 150 mm
Extra over item 74-A-B for providing salt glazzed stone
ware fittings
(iii) single junction of required angle of following internal
diametres.
(A) 100 mm
(B) 150 mm
Providing laying, jointing and pointing with stif mixture of
cement mortar 1:1 ( 1 cement : 1 fine sand) 150 mm
internal deiametre salt glazed stone ware half round
channels
Providing and fixing S.W. Gully trap with C.I. Grating brick
masonary chamber and water tight C.I. Cover with frame
of 300 mm. X 300 size (inside) with standard weight
(I) Square mouth traps
(A) 100 mm. X 100 mm. Size p -- type
(C) 150 mm. X 100 mm size p or R type
Providing and laying (two level or slopes) and jointing
reinforced concrete light duty, nonpressure pipes I.S> class
NP/2 of the follwing internal diameter with collars and
butt ends prepared for collar joints including testing of
units complete. ( Storm Water Under Ground Net Work)
(B) 150 mm.
50.0
125.0
Metre
Metre
170.00
239.00
8500.00
29875.00
50.0
125.0
Metre
Metre
108.00
181.00
5400.00
22625.00
10.0
15.0
Each
Each
74.90
87.70
749.00
1315.50
5.0
Each
106.00
530.00
Each
Each
Metre
93.50
124.00
153.00
187.00
248.00
19125.00
Each
Each
1447.00
1497.00
5788.00
8982.00
Metre
235.00
23500.00
2.0
2.0
125.0
4.0
6.0
100.0
Page 10 of 23
Sr.No.
Description
87 (C) 250 mm.
88 Constructing manhole with R.C.C. top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm.
Nominal size, foundationconcrete 1:3:6 mix (1 cement : 3
coarse sand : 6 Brick balts 40 + 50 mm. Thick with cement
mortar 1:5 (1 cement : 5 coarse sand) finished with a
floating coat of neat coment and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
aggregate 20 mm. nominal size) finished smooth complete
including curing and testing.
Qty
100.0
Unit
Metre
Rate
275.00
Amount
27500.00
17.0
Each
11107.00
188819.00
(I) Extra rate for constructing B.B. Masonry for every
additional epth of 0.1 M.or part thereof over item 88 (ii)
for depth from 0.9 M. to 1.5 M.
Providing and fixing cast iron steps of size 500 mm. X 150
mm. X 22.5 mm. And painting with two coat, coats of
anticorrosive paint etc. complete.
Supplying and fixing C.I. Cover 300 mm. X 300 mm.
Without frame for gully trap (Standard pattern) the weight
of cover to be not less than 4.35 Kg.
Constructing brick masonary chamber for under ground
C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35 Kg/cm2 in cm. 1:5 C.I.
Cover with frame (light duty) 455 mm. X 610 mm. Internal
dimensions, total weight of cover with frame to be not less
than 38 Kgs. weight of cover 23 Kg. and wt. of frame 15 Kg)
R.C.C. tiop slab with 1:2:4 mix(1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm. size ) foundation concrete
1:5:10 inside plaster 15 mm. thickwith cementmortar 1:3
finished smooth with a floating coat of neat cement on
walls & abed concrete etc. complete.
17.0
Each
511.00
8687.00
51.0
Each
166.00
8466.00
10.0
Each
614.00
6140.00
(I) inside dimensions, 455 mm. 610 mm. And 450 mm.
Deep for single pipe line.
(ii) Inside dimensions, 500 mm. X 700 mm. And 450 mm.
Deep for pipe line with one or two inlets.
(iii) Inside dimensions, 600 mm. X 850 mm. And 450 mm.
Deep for pipe lines with three of more inlets.
Providing item no. 92 for every additionaldepth of 0.1 mm.
Or part thereof beyond 450 mm. Depth for brick masonary
chember.
(I) or 445 mm. X 610 mm. Size
(ii) for 500 mm. X 700 mm. Size
(iii) for 600 mm. X 850 mm. Size
4.0
Each
2865.00
11460.00
1.0
Each
3400.00
3400.00
1.0
Each
8455.00
8455.00
4.0
1.0
1.0
Each
Each
Each
234.00
255.00
314.00
936.00
255.00
314.00
(I) Inside size 900 mm. X 1200 mm. And 1:5 mm. Deep
including C.I. Cover with frame size 560 mm. Total weight
of cover and frame to be not less than 128 Kgs. (Wt. Of
cover 64 Kgs and Wt. Of frame 64 Kgs)
(A) With 230 mm. Thick walls of brick masonry using brick
having crushing stregth not less than 35 Kg/sq cm. In
cement mortar 1:5(1 cement : 5 coarse sand)
(1) A type depth 0.90 metre for 150 mm diameter sewer.
89
90
91
92
93
94
95
96
97
Page 11 of 23
Sr.No.
98
99
100
101
102
103
104
105
106
107
108
109
110
Description
(II) Water Supply System:Providing and fixing to wall ceiling and floor U - PVC pipes
with special U - PVC fittings, wall clips etc. including
making good the wall ceiling and floor etc complete as
directed.
a) 15mm.dia.Pipe
c) 25mm.dia.Pipe
Providing and fixing to wall, ceiling and floor 6.0 Kg f/cm2
working pressure polythelene pipes of the following
outside dia. Low density, complete with special flange
compression type fittings wall clamps etc. including
making good the wall, ceiling and floor.
Qty
Unit
Rate
Amount
20.0
50.0
RMT.
RMT.
83.20
103.00
1664.00
5150.00
(D) 40 mm. 10 Kg/cm2
(E) 50 mm. 10 Kg/cm2
Providing and fixing to wall ceiling and floor 6.0 kg. F/cm2
working pressure polythylene pipes of the following
outside dia. special density, complete with special flange
compression type fittings, wall clips etc. including making
good the wall ceiling and floor.
95.0
200.0
Metre
Metre
91.00
122.00
8645.00
24400.00
a) 75mm. dia.pipe.
b) 100mm.dia.pipe.
Providing and fixing in position cowlvent to pipes :
(I) 75 mm dia.
(ii) 100 mm. Dia.
Providing and fixing cast iron (spun) Nahni trap of the
following nominal diametre of seld cleaning design with
C.I.screwed down or highd gratting including cost of
cutting and making good the walls and floors 100 mm.
Inlet and 50 mm. Outlet.
Providing and fixing wash down water closet (european
type, W.C. Pan with integral 'P' or 'S' trap including jointing
the trap with soil pipe in cement mortar 1:1 (1 cement :
1fine sand) (seat and cover to be measured and paid for
seperately)
(A) Vitereous china pattern : I
(I) In white color
Providing and fixing 100 mm. Size 'P' or 'S' trap for water
closet squatting pan including jointing the trap with the
pan and soil pipe in cement mortar 1:1 (1 cement : 1fine
sand)
(A) Vitreous china
Providing & Fixing jet spray for european w/c of approved
make as directed
Providing and fixing 12.5 litres low level flushing cistren
with a pair of C.L.I. Or Mild Brakets, complete with fittings
such as lead value syphon, 15 mm. Nominal size brass ball
valve with polythene float, C.P. Brass handleunions and
couplings for connections with inlet, outlet and over flow
pipes, 40 mm. dia. porcelain enamelled flush bend
including cutting holes in walls and making the flush bend
with cistern and closet (over flow pipe to be measured and
paid for seperately)
110.0
220.0
RMT.
RMT.
210.00
375.00
23100.00
82500.00
8.0
6.0
34.0
Each
Each
Each
428.00
581.00
431.00
3424.00
3486.00
14654.00
12.0
Each
1021.00
12252.00
12.0
12.0
Each
NO.
226.00
350.00
2712.00
4200.00
Page 12 of 23
Sr.No.
111
112
113
114
115
Description
(A) Vitreous china
(I) In white colour
Providing and fixing in position with clamps etc. 32 mm
nominal internal diametre galvanised stel tube flush pipe
for high level flushing cistern includig connecting the flush
pipe with cistern and closet making good the walls and
floors.
Providing & fixing G.I.inlet connection for flush pipe with
W.C. pan
Providing and fixing plastic seat and cover for wash down
water closet with C.P. Brass hinges and rubber buffers.
B.Black plastic seat and cover
Providing and fixing wash basin with single hole for pillar
tap with C.I. Or M.S. brackers painted white including
cutting holes and making good the same but excluding
fittings :
(A) Vitreous china
(ii) Flat back wash basin 500mm x 400mm size
(I) in white colour
Providing and fixing Kitchen sink with C.I. Or M.S. brakets
painted white including cutting holes in walls and making
good the same but excluding fittings :
Qty
Unit
12.0
12.0
Each
Metre
12.0
Rate
Amount
1293.00
158.00
15516.00
1896.00
Each
33.80
405.60
12.0
Each
398.00
4776.00
12.0
Each
1055.00
12660.00
1.0
Each
2280.00
2280.00
116
(C) Vitreous china sink
(I) 600mm x 450mm x 150mm size
Providing and fixing C.P. brass waste for wash basin or sink
(B) 40 mm dia.
Providing and fixing M.I. Fisher union for wash or sink.
13.0
Each
113.00
1469.00
117
(B) 40 mm dia.
Providing and fixing 100 mm. Sand coast iron grating for
gully floor or nahne trap.
Providing and fixing toilet paper holder
(A) C.P. Brass
Providing and fixing screw down bib taps of following size :
13.0
34.0
Each
Each
115.00
40.00
1495.00
1360.00
12.0
Each
404.00
4848.00
12.0
Each
256.00
3072.00
(A) 15 mm. Dia
Providing and fixing brass screw down stop
(A) 15 mm. Dia
Providing and fixing gun metal check or nonreturn fullway
wheel valve
(A) 15 mm. Dia
(C) 25 mm. Dia
(E) 40 mm. Dia
Providing and fixing urinal approved quality connecting
the urinal with waste pipe, trap etc. complete.
12.0
Each
422.00
5064.00
12.0
Each
282.00
3384.00
5.0
5.0
12.0
Each
Each
Each
302.00
575.00
907.00
1510.00
2875.00
10884.00
(A) White earthern ware flat back or cornor tpe size
11.0
Each
761.00
8371.00
118
119
120
121
122
123
124
125
126
(B) Brass chromium plated screw down bib tap
(I) 15 mm dia.
Providing and fixing Pillar Tap, capstan head, screw down
high pressure with screws, shanks and backnuts
Page 13 of 23
Sr.No.
127
128
Description
430mm x 260mm x 350 mm
Providing and fixing urinal approved quality connecting
the urinal with integral longitudinal flush pipe
Providng and fixing chromium plated bottle trap with
necessary coupling of approved quality for wash basin
130
Providing and fixing ball cock of approved quality as
directed
(B) Abonite
(I) 25 mm dia.
Providing and fixing C.I. Manhole cover 0.60m x 0.45m size
having weight not less than 35 kgs.
Providing and fixing G.I. Rain water spout of 50 mm. Dia.
And 30 cm. Length
Providing erecting and fixing double coated syntex or
equivalent PVC ( ISI) water tank of required capacity each
with all neceesary fitting and connection etc complete on
terrace
(A) 02 x 2000 Litre capacity
132
133
Unit
Rate
11.0
Each
1111.00
12221.00
13.0
Each
21.90
284.70
12.0
Each
380.00
4560.00
4.0
17.0
Each
Each
269.00
1311.00
1076.00
22287.00
12.0
Each
144.00
1728.00
4000.0
Liter
4.60
18400.00
1.0
1.0
Nos
Nos
550.00
105.00
550.00
105.00
9.0
Ea.
2490.00
22410.00
3.0
Ea.
2920.00
8760.00
162.0
Ea.
95.00
15390.00
(A) Squating plate pattern white earthern ware 550 mm. X
300 mm.
Providing and fixing rubber plug of sink or wash basin
129
131
Qty
Amount
PART C - ELECTRICAL WORK
PANEL
134
135
136
137
138
Providing and erecting four pole MCB Isolator AC 22 duly
confirms to IS:13947-3 having following capacity
for 63 Amp
b) cat-II
Plastic enclosure fitted with DIN rail suitable fr
incorporating Three / Four nos. MCB
Providing and erecting Sheet Steel powder coated
approved Make MCB Distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and
DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs. (The DBs should
be used of same company of MCB to be used)
(L) Three phase 6 way SS Double door for single phase
outgoing horizontal box.
(N) Three phase 8 way SS Double door for single phase
outgoing horizontal box.
Providing and erecting approved make Miniature circuit
breaker single pole 6A to 32A suitable to operate on 240 V
A.C. system and having overload and short circuit tripping
elements and breaking capacity 10 KA to be erected in
existing M.S. box confirming to IS 8828/1996 with ISI mark.
Cat.II
Page 14 of 23
Sr.No.
Description
139 Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
capacity
(C) 63 Amp.
Cat.II
140 Providing and erecting approved make ELCBs / RCCBs
conforming to IS : 12640 and having sensitivity of 30m A
and Short Circuit with stand capacity of 6 KA and suitable
for operation on single phase 240 V. having charectorstic
of quick acting & tripping with all advance feature & do
not incorporate any electronic component.for following
Max. rating.
141
142
143
144
145
146
147
148
149
150
Qty
Unit
Rate
Amount
12.0
Ea.
660.00
7920.00
36.0
Ea.
2010.00
72360.00
1.0
Ea.
9880.00
9880.00
1.0
Ea.
230.00
230.00
3.0
Ea.
80.00
240.00
B)3.1/2 Core 70 Sq.mm (35 Sq.mm 1/2 Core)
G)3.1/2 Core 240 Sq.mm (120 Sq.mm 1/2 Core)
Providing and erecting XLPE (IS : 7098)(I)-88 ISI marked
approved make armoured cable of multistrand
Aluminium conductor for 1.1 KV to be laid on wall with
necessary clamps or in existing cable trench / pipe at road
crossing or floor of following size of cables.
16.0
40.0
Mtr.
Mtr.
455.00
1360.00
7280.00
54400.00
(e) 4 core 16 sqmm
(f) 4 core 25 sqmm
Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with outgoing rails, insulating tape etc for
following size of cables.
a) 3.1/2 /4 Core 25 Sq.mm
c) 3.1/2 Core 70 Sq.mm
h) 3.1/2 Core 240 Sq.mm
ARMOURED COPPER CABLES
88.0
76.0
Mtr.
Mtr.
180.00
240.00
15840.00
18240.00
12.0
2.0
4.0
Ea.
Ea.
Ea.
70.00
110.00
265.00
840.00
220.00
1060.00
(ii) 40 Amps. DP
Cat.II
Providing Approved make Tripple Pole Metal Clad Switch
Fuse Unit 415/500V with HRC Fuse of suitable load and
neutral link confirming to I.S.
(c.) 250 A
Cat-III
Erection & connection charges for 250A/300A / 325A HRC
TPN as following.
(b) Erection on New angle iron frame duty painted with
red oxide.
Providing and erecting metallic vetrified Danger Notice
Boards for MEDIUM VOLTAGE installation to be erected as
per I.S.
Providing and erecting XLPE (IS : 7098)(I)-88 ISI marked
approved make armoured cable of approved make
multistrand Aluminium conductor for 1.1 KV to be laid on
wall with necessary clamps or in existing cable trench /
pipe at road crossing or floor of following size of cables.
Page 15 of 23
Sr.No.
Description
151 Providing and erecting XLPE (IS : 7098)(I)-88 ISI marked
approved cable of approved make multistrand Copper
conductor for 1.1 KV to be laid on wall with necessary
clamps or in existing cable trench / pipe at road crossing or
floor of following size of cables.
152
153
154
155
156
157
158
159
160
161
162
163
164
a) 3 Core 4 Sq.mm.
b) 3 Core 6 Sq.mm.
Providing and erecting XLPE(IS:7098)(I)-88 ISI marked
armoured cable multistrand Copper Conductor for 1.1 KV
to be laid on wall with necessary clamps or in existing
cable trench / pipe at road crossing or floor of following
size of cables.
B) 4 Core 6 Sq.mm.
Providing and erecting XLPE (IS : 7098)(I)-88 ISI marked
armoured cable of approved make multistrand Copper
conductor for 1.1 KV to be laid on wall with necessary
clamps or in existing cable trench / pipe at road crossing or
floor of following size of cables.
Qty
Unit
Rate
Amount
61.0
0.0
Mtr.
Mtr.
275.00
380.00
16775.00
450.0
Mtr.
490.00
220500.00
a) 3 Core 2.5 Sq.mm.
Cable Glands.
Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with outgoing rails, insulating tape etc for
following size of cables.
(a)2 to 4 core 2.5sqmm
(b)2 to 4 core 4sqmm
(c)2 to 4 core 6sqmm
(e) 2 to 4 Core 16 Sq.mm
Cable Lugs.
Solderiess crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner.
61.0
Mtr.
95.00
5795.00
6.0
6.0
60.0
14.0
Ea.
Ea.
Ea.
Ea.
35.00
35.00
40.00
50.00
210.00
210.00
2400.00
700.00
C) 16 Sq.mm.
D) 25 Sq.mm.
E) 35 /50Sq.mm.
F) 70 Sq.mm.
Solderiess crimping type Copper lugs conforming to IS
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner.
A) 2.5 to 6 Sq. mm.
(C) 16 Sq.mm.
Making Trench in soft soil of suitable width of 90 cms.
Deep for laying cable or locating the fault all over the run
and backfilling the same and making the surface proper.
0.0
48.0
2.0
6.0
Ea.
Ea.
Ea.
Ea.
15.00
15.00
20.00
25.00
720.00
40.00
150.00
36.0
56.0
Ea.
Ea.
8.00
12.00
288.00
672.00
60.0
Mtr.
40.40
2424.00
C) For 120 Sq.mm to 300 Sq.mm cable.
Point Wiring in Copper (Modular)
Note :Page 16 of 23
Sr.No.
165
166
167
Description
1. For Point wiring above 10 mtr of length, additional
length will be
added at rate of mains.
2. For point wiring in bathroom ,W/C and Wash basin area
in residential
quarters reduce overall rate by 50% of point wiring for
light.
3. For E.I. work in Highly Security restricted areas like Jails,
V.V.I.P.
Residences, add 10% of overall cost of estimate.
Point wiring for light with 2-1.0 sqmm & earthwire of 1.0
sqmm (green) both are of ISI marke approved make PVC
insulated multistrand copper wires, in existing pipe duly
erected complete with 6A Modular type switch/bell push
& accessories of approved make and earth continuty of
following type, erected on PVC/Metallic box covered with
appropriate front plate modules erected concealed in
wall/ceiling. (Loop point include)
(B) Single mounting base-frame & Textured/Metallic front
plates.
Cat. II
Point wiring for FAN with 2-1.0 sqmm & earth wire of 1.0
sqmm (green) both are of ISI marke approved make FR
PVC insulated mutistrand copper wires, in existing pipe
duly erected complete with 6A Modular type switch and
hum free EME 5/6 step type electronic fan regulator with
separately mounted and accessories of approved make
with earth continuity of following type erected on
PVC/Metallic box covered with appropriat front plate
modules erected concealed in wall/ceiling.
(a) with medium class rigid PVC Pipe and accessoris.
(B) Single mounting base-frame & Textured/Metallic front
plates.
Cat. II
Point wiring for Individual Plug with & earthwire of 1.5
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type
of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected
on PVC / Metallic box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.
Qty
Unit
Rate
Amount
150.0
Pt.
400.00
60000.00
45.0
Pt.
580.00
26100.00
76.0
Pt.
430.00
32680.00
(a) with medium class rigid PVC Pipe and accessiries.
168
(B) Single mounting base-frame & Textured/Metallic front
plates.
Cat. II
Point wiring for looped plug with 6A Modular type switch
and 5 pin socket erected on PVC/Metallic box covered
with appropriat front plate modules erected concealed in
wall/ceiling with following type of accessories of approved
make.
Page 17 of 23
Sr.No.
169
170
Description
(B) Single mounting base-frame & Textured/Metallic front
plates.
Cat. II
Point wiring for Two Way Controlled Light Point with 2-1.5
sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI
marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected
concealed in / flushed on wall/ceiling ,complete with 6A
Modular type switches and following type of accessories
erected on PVC / Metallic box, single mounting base frame
covered with textured / metallic front plate modules
erected on / in wall / ceiling as per pipe erected. with
necessary batten/angle holder or ceiling rose or
H.D.Connector as directed.
Qty
Unit
Rate
Amount
15.0
Pt.
220.00
3300.00
28.0
Pt.
510.00
14280.00
Cat. II
(4) Two Pin/RJ-11 Telephone socket with Top.
Cat. II
(5) TV Co-axial Socket outlet.
Cat. II
(8) Blank plate Single
Cat. II
(9) Modem Jack for Computer Open RJ-45
Cat. II
(10) 16 Amp. SP one way switch.
Cat. II
(11) 6/16 Amp. Universal socket.
Cat. II
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole Modular
MCB Switch
Cat.II
(20) Modular Buzzer
Cat.II
Providing & Erecting approved make following size of TV
Co-axial flexible cable comprising inner conductor of solid
bare copper insulated with Foam PE & Secondary
conductor made of poly - Aluminium film bonded Al.
Braids @ suitable coverage overall sheathed with black
PVC insulation.
70.0
Ea.
470.00
32900.00
50.0
Ea.
130.00
6500.00
5.0
Ea.
140.00
700.00
10.0
Ea.
15.00
150.00
70.0
Ea.
140.00
9800.00
15.0
Ea.
130.00
1950.00
15.0
Ea.
140.00
2100.00
5.0
Ea.
330.00
1650.00
6.0
Ea.
130.00
780.00
a) RG -6
Conduits & Pipes
30.0
mtr
30.00
900.00
(a) with medium class rigid PVC Pipes.
(B) Single mounting base-frame & Textured/Metallic front
plates.
Cat. II
Providing following type of Modular Type Accessories
mounted with pvc / metallic box, single mounting base
frame covered with textured / metallic front plate ,
modules erected with necessary connection. As desired by
Engineer In charge
(3) One No. 16 A SP switch and Two nos. 6Amp 5 pin plug.
171
172
173
174
175
176
177
178
179
Page 18 of 23
Sr.No.
Description
180 Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed
181
Qty
Unit
5099.0
Mtr.
32.00
163168.00
2020.0
Mtr.
80.00
161600.00
(a) 2 wire 4 sq. mm
Earthings & Lightning
Mains wit approved make ISI marked, 1.5 KV grade
electrilyte stranded, annealed copper conductor with 105
C heat resistant PVC insulated conforms to IS 694, IEC 227 erected in existing pipe of following size with required
size of copper lugs, nuts and bolts if required.
480.0
Mtr.
110.00
52800.00
(e) One wire 6.00 sq. mm
Supply, installation, testing and commissioning of
chemical pits using chemical earth enhancing compound
of 20 kg kits (ISOGEL).chem. rod 8 fts long,3 inch dia 0.12
inch complete with 25mm x 3 mm copper strip 7.5 mtrs to
the earth point upto the test link including test link
inspection chamber made of heavy duty plastic with cover
etc. as required.complete as per specifications and
direction of engineer in charge. The earth resistance
should be less than 0.5 ohms.
60.0
2.0
Mtr.
NO
25.00
10000.00
1500.00
20000.00
(b) 25 mm
Mains & Wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
Rate
Amount
(a) with medium class Rigid PVC pipe and accessories
182
(c) 2 wire 2.5 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size
(a) with medium class Rigid PVC pipe and accessories
183
184
185
Supplying & Erecting approved make Telephone Cable
electrolytic grade annealed copper conductor insulated
with PE insulation twisted in to pairs with colour
combination bunched together in concentric layers so as
to minimies cross - talk & wrapped with FR PVC tap &
sheathed with FR PVC or HFFR outer Jacket suitable for
indoor telephone wiring & confirming to C-DOT S/WS - 113
/ IEC 60189-2. UL - 1581 SECTION 1080 VW - 1 erected in
existing pipe of following size of conductors & nos. of
pairs. With necessary connections.
Page 19 of 23
Sr.No.
186
187
188
189
190
191
192
193
194
195
Description
(b) Armoured
21) Ten Pairs
23) Twenty Pair
23) Fifty Pairs
Supply and Installation of approved make telephone tag
block of following size as per direction of engineer
incharge.
20 pair
Supplying & erecting Digital / PCM / TDM EPABX System
having SMT design, system with flexible universal slots,
Inbuilt Auto attendant facility, Minimum 15 Nos.
conference, Analog extension line, Calling GSM, E&M line,
PRI / E1 & VOIP program me through Analog telephone
digital key from Ethernet, public address cord, shall have
unrestricted simultaneous dialling facility, QSIG protocol
on PRI, 95 / STD / ISD / Local- Locking ,Class of Service,
Quick Dial- Single Digit dialling of any two external
numbers, Once only ring device, Boss/Secretary- Do not
Disturb Facility, Power Down Mode, Hot Line, Hot
Outward Dialling, Day Night Mode, Auto Call Back, Bargein, Call Pick Up & Call Transfer, Call transfer while Ringing.
With Voice Guide System, (DISA), Caller ID (CLI), CLI Base
ECF,CLI Base routing Internet Ready Port, External Music
Port, Call Budgeting, Call Most Calculation(ASMDR), DID
Direct Inverse Dialling, External Music Input, Fax Homing,
Global Directory Printing. with following capacities
Small EPABX System with In Built 4 Port Voice Mail
[D] No. Extension - 64 , No. of Junction -16 , No. of
expandable ports -256 , Operator Console 01 - Compatible ISDN and Networking
Supply and laying of Approved make Lan wire cat-6 for
Data & telephone cabling as per direction of engineer
incharge.
Providing and fixing of Pach cord for CAT 6 Cable from CPU
to computer Jack 0.9 mtr Data Cable with 4 pair connector
both side.
Supply and laying of legrand make RG-11 for TV cabling as
per direction of engineer incharge.
INETRNAL LIGHT FIXTURE
Supply, installation, Testing and Commissioning of
approved make 2 X 36W Surface / reccess mounted CFL
Light fixture with lamp complete with all accessories as
required, as per drawing, as per approval of Architect /
Client and as per direction of engineer incharge.
Qty
Unit
Rate
Amount
0.0
35.0
5.0
Mtr.
Mtr.
Mtr.
100.00
160.00
390.00
5600.00
1950.00
3.0
Ea.
1720.00
5160.00
1.0
Ea.
217306.00
217306.00
2100.0
Mtr.
40.00
84000.00
70.0
Ea.
220.00
15400.00
150.0
Ea.
45.00
6750.00
24.0
Ea.
3350.00
80400.00
100.0
Ea.
443.00
44300.00
6.0
Ea.
1000.00
6000.00
Providing & fixing 4 feet T-5 type complete tubelight (28
watts)
Supply, installation, Testing and Commissioning of
Approved make 2 X 28W T-5 light fixture with lamp
complete with all accessories as required, as per drawing,
as per approval of Architect / Client and as per direction of
engineer incharge.
Page 20 of 23
Sr.No.
Description
196 Supply, installation, Testing and Commissioning of
approved make 2 X 26W Surface / reccess mounted CFL
Light fixture with lamp complete with all accessories as
required, as per drawing, as per approval of Architect /
Client and as per direction of engineer incharge.
Qty
35.0
Unit
Ea.
Rate
3000.00
Amount
105000.00
Supply, installation, Testing and Commissioning of
approved make Decorative Bracket Light fixture with lamp
complete with all accessories as per drawing, as per
approval of Consultant / Client and as per direction of
engineer incharge.
Supply, installation, Testing and Commissioning of
approved make Bulk Head 1 x 18W fixture with lamp
complete with all accessories as per drawing, as per
approval of Consultant / Client and as per direction of
engineer incharge.
Providing & erecting approved make 2 X 18 W CFL
decorative recess mounting Down Lighter fittings with
anodized Aluminium, lamp with copper ballast holder and
necessary lead wirecomplete with all accessories as per
drawing, as per approval of Consultant / Client and as per
direction of engineer incharge.
10.0
Ea.
1600.00
16000.00
12.0
Ea.
600.00
7200.00
5.0
Ea.
1700.00
8500.00
200
Providing & erecting approved make 2 X 18 W CFL
decorative Surface mounting Down Lighter fittings with
anodized Aluminium, lamp with copper ballast holder and
necessary lead wirecomplete with all accessories as per
drawing, as per approval of Consultant / Client and as per
direction of engineer incharge.
12.0
Ea.
1700.00
20400.00
201
Poviding and erecting recess/surface mounted fittings for
2 nos of 40W tubes complete with starter copper wound
polyester choke, complete holder and lead with the
connection.
Cat. II
1408.00
8448.00
197
198
199
202
203
204
205
FAN & ACCESSORIES
Approved make Power Saving 50 Watt Ceiling Fan with
Condenser 230 Volt A.C. 50 Cys. 1200 mm sweep
complete having 3 blades with aluminium blades with,
canopy & 30 core flexible wire with earthing. (Havells,
Orient, Crompton, Anchor, Bajaj)
Supplying and erection 19/20 mm nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
complete with necessary 24/0.2 flat 3 core flexible wire
with earthing
Supplying & erecting fan hook box of 10 mm M.S. round
bar bounded to the RCC bars up to 50 mm length each
side and pierced through a 16 Gauge M.S. box/Heavy Duty
PVC box having depth of 75 mm complete cercted
concealed in Ceiling with necessary finishing.
Providing 2.5 mm thick laminated sheet to cover the fan
hook or fan box.
Page 21 of 23
6.0
45.0
Ea.
2070.00
93150.00
45.0
Ea.
125.00
5625.00
45.0
Ea.
125.00
5625.00
45.0
Ea.
50.00
2250.00
Sr.No.
Description
206 Providing & Erecting follwing Shockproof tissino type
accessories erected on 3 mm thick laminated sheet in
wooden / PVC / Metal Box, erected on wall / ceiling.
207
208
7) Bakelite ceiling rose
Supplying & erecting single phase approved make
industrial exhaust fan suitable for medium duty ring
mounted low noise operation suitable for medium duty
having following dia size and maximum speed in RPM
cat.II
[C] 380 mm dia 1400 RPM
Providing, and erecting 11 KV D.P. 6 mtr. high Structure
made of 6" x 3" ‘I’-Section Girder, 4" x 2"channels, clamps,
nuts, bolts etc. Suitable for erection of the followings duly
connected with necessary ACSR conductors. as per
drawing approved by the Engineer- in charge complete
with following. Height as per IS 7 Mtr above ground )
(C) 11 KV lightening arrestor with clamp-
209
210
211
Three Nos.
Providing & Fixing submersible pump having 2.00 HP
motor of ISI brand with all G.I. fittings for inlet & outlet
connection etc complete as directed
Providing & laying 20 to 25mm thick, both faces polished
kotah stone with all edges machine cut up to 450mm
width and of required length (only one piece to be used )
of approved quality for cupboard shelves including fixing
the same in masonry wall by cement mortar in three
sides including curing etc. complete as directed by E.I.C .
Providing and fixing built in wall teak wood cup‑board
shutters having 75 * 50 mm. teak wood frame and shutter
with 19mm. Thick block board with 01 mm thick laminated
sheet on front side and fixing the same by adhesive &
necessary hardware incl. T.W. Beading of 20 * 10 mm size
surronding the edges of block board shutters and front
moulding of 40 * 15 mm size on periphery of shutters
incl.03 no. of hinges on each flap of shutters,good quality
handle,magnate & locking arrangement for C.B.shutters
etc. fixtures & fastenings with 03 – coats of french polish
etc complete incl.all materials,labour,tools & tackels as
directed.
( SHELVES SHALL BE PAID SEPARATELY.)
Qty
Unit
Rate
Amount
45.0
Ea.
15.00
675.00
17.0
Ea.
3600.00
61200.00
1.0
Ea.
10500.00
10500.00
1.00
Ea.
7500.00
7500.00
135.0
Smt
724.00
97740.00
100.0
Smt
3300.00
330000.00
Total estimated amount Rs.
17816972.88
We have read and clearly understood the terms, conditions,
Schedule ‘B’ and Technical specifications put up by UGVCL on
WEB site.
Page 22 of 23
Sr.No.
Description
Qty
Unit
Rate
I/We hereby accept all the conditions and specifications of this tender
document, and accordingly, I/We am/are willing to carry out the work at
_________________% (in words ______________percentage) above/below the
estimated cost. Accordingly the total amount of my/our tender works out to
Rs._____________________________
SIGNATURE OF CONTRACTOR
(With rubber stamp/seal of the company)
Page 23 of 23
Amount
Chief Engineer (Operation)
UGVCL R.O. MEHSANA
Fly UP