APPENDIX F DRAWINGS OF FULL-DEPTH DECK PANELS FROM UTAH DOT
by user
Comments
Transcript
APPENDIX F DRAWINGS OF FULL-DEPTH DECK PANELS FROM UTAH DOT
APPENDIX F DRAWINGS OF FULL-DEPTH DECK PANELS FROM UTAH DOT Note: These are direct extract from <http://www.udot.utah.gov/main/uconowner.gf?n=5440222707642218> (Last accessed June 25, 2012) CLOSURE POUR CONCRETE: PRECAST PANEL REINFORCING PDP-7 PRESTRESSED PANEL REINFORCING f’c = MATCH PRECAST ELEMENTS PDP-8 NON-SHRINK GROUT: PDP-9 REINFORCING STEEL (COATED) MIN. OVERHANG = 1’-0" DEAD LOADS: 40 PSF FUTURE OVERLAY NO MORE THAN 2 EXTERIOR TRAFFIC PARAPETS PER PANEL MAX. DEAD LOAD PER PARAPET = 569 PLF PANEL-TO-PANEL CONNECTIONS: ALL PANELS TO BE CONNECTED WITH LONGITUDINAL POST-TENSIONING COMBINED WITH A TRANSVERSE GROUTED KEYWAY JOINT. DEFINITIONS DESIGN ALL POST-TENSIONING. SHOW SIZE AND LAYOUT OF DUCTS. SPECIFY JACKING FORCES, SEQUENCE OF JACKING, DUCT WOBBLE COEFFICIENTS, AND DUCT COEFFICIENT OF FRICTION. PROVIDE POSITIVE DRAINAGE DETAILS PER UDOT STANDARD PRACTICE. DRAINAGE HOLES THROUGH THE PANELS ARE PROHIBITED. DESIGN AND ACCOMMODATE APPLICABLE REINFORCEMENT FOR A HAUNCH GREATER THAN 3". INCLUDE APPLICABLE GENERAL NOTES IN THE PLAN SET. PRECAST PANEL: CONCRETE PANEL REINFORCED WITH DEFORMED STEEL BARS. PRESTRESSED PANEL:CONCRETE PANEL REINFORCED WITH PRESTRESSING STEEL AND DEFORMED STEEL BARS. OPTIONAL DETAILS THESE DRAWINGS ARE BASED ON THE USE OF BLIND BLOCKOUTS FOR SHEAR CONNECTIONS FORMED WITH REMAIN IN PLACE STEEL BOXES. OPTIONAL BLOCKOUT DETAILS SHOWN ON DRAWING NUMBER PDP-9 ARE ALSO ACCEPTABLE. VERIFY SIZE AND SPACING OF REINFORCEMENT CONNECTING PARAPET TO PANEL IF PARAPET OTHER THAN TYPE SPECIFICALLY SHOWN IN THESE STANDARD DRAWINGS IS USED. AT A MINIMUM EXTEND CONTINUOUS REINFORCEMENT FROM PRECAST PANEL, #6 AT 6" SPACING TOP AND BOTTOM, INTO CLOSURE POUR. CLOSURE POUR DETAILS SHOWN FOR MAXIMUM BEAM SPACING OF 10’-0". FOR BEAM SPACINGS GREATER THAN 10’-0", DESIGN AND DETAIL CLOSURE POUR AND APPROPRIATE POST-TENSIONING AS REQUIRED. INCLUDE A TABLE OF ESTIMATED QUANTITIES OF PRECAST CONCRETE DECK PANELS. TABLE TO INCLUDE THE FOLLOWING: - PANEL TYPE (BASED ON PANEL LAYOUT) - NUMBER OF EACH PANEL TYPE REQUIRED - SQUARE FOOTAGE OF AREA PER PANEL - TOTAL SQUARE FOOTAGE OF DECK PANELS CLOSURE POUR DETAILS f’c = 5,000 PSI @ 24 HRS SHEAR CONNECTOR BLOCKOUT DETAILS fy = 60,000 PSI PDP-10 SHEAR CONNECTOR DETAILS NEW GIRDERS PRESTRESSED LOW RELAXATION STRAND: fpu fpbt = 202.5 KSI = 270.0 KSI PDP-11 SHEAR CONNECTOR DETAILS EXISTING GIRDERS PDP-12 VERTICAL ADJUSTMENT DETAILS STRUCTURAL STEEL: fy = 50,000 PSI AASHTO M270 GR 50 USE UTAH DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (THE LATEST EDITION AND SUPPLEMENTS THERETO WHICH ARE IN EFFECT AT THE DATE OF REQUEST FOR BIDS) ALONG WITH SPECIAL PROVISIONS SECTION 03339S-FULL DEPTH STANDARD PRECAST CONCRETE DECK PANELS FOR MATERIALS, CONSTRUCTION AND WORKMANSHIP. PDP-13 TYPICAL POST-TENSIONING DETAILS 1 PDP-14 TYPICAL POST-TENSIONING DETAILS 2 PDP-15 PARAPET DETAILS 1 PDP-16 PARAPET DETAILS 2 USE THE PCI DESIGN HANDBOOK, PRECAST AND PRESTRESSED CONCRETE, FIFTH EDITION WITH ALL INTERIMS AND ERRATA FOR THE DESIGN AND DETAIL OF LIFTING SUPPORTS AND HANDLING CONSIDERATIONS (NO CRACKING CRITERIA). USE A HEAVY BROOM FINISH FOR TOP SURFACE OF PANELS AND ALL JOINT SURFACES. CHAMFER ALL EXPOSED CORNERS ". PRECAST PANELS ADJACENT TO CLOSURE POURS OR OTHER PANELS ARE NOT CONSIDERED EXPOSED CORNERS. THE PRECAST PANELS HAVE A " CONCRETE GRINDING ALLOWANCE FOR CORRECTING UNEVEN ROADWAY SURFACES AT TRANSVERSE JOINTS BETWEEN PRECAST CONCRETE DECK PANELS AND END OF BRIDGE DECK OR EDGE OF ADJACENT PHASE(S). DECK THICKNESS SHOWN AS NOMINAL OR FINAL THICKNESS AFTER GRINDING. ACCOUNT FOR " GRINDING ALLOWANCE. APPLY CONCRETE POLYMER OVERLAY ON BRIDGE DECK AFTER CONCRETE GRINDING OR STEEL SHOT IS COMPLETE. SEE SECTION 03372 IN THE STANDARD SPECIFICATIONS FOR SURFACE PREPARATION REQUIREMENTS. SEE TOP OF PANEL ELEVATION SHEETS AND/OR CONCRETE UNIT SHEETS FOR SIZE, TYPE, ORIENTATION, NUMBER AND SPACING OF SHEAR STUDS/BLOCKOUTS. COAT ALL MILD REINFORCEMENT PER UDOT SPECIFICATIONS UNLESS OTHERWISE NOTED. USE A CORROSION INHIBITOR ADMIXTURE FOR ALL STRUCTURAL GROUT. USE A CORROSION INHIBITOR ADMIXTURE FOR ALL PANEL AND CLOSURE POUR CONCRETE. COUNTY PDP - 1 7/19/2010 QUANT. DRAW N DATE UDOT DESI GN M ANAGER SENI OR DESI GN ENGI NEER BY PDP-17 DECK PANEL TOLERANCES WELD ACCORDING TO AASHTO/AWS D1.5 BRIDGE WELDING CODE. SEE "GENERAL LAYOUTS" AND "TYPICAL DECK PANEL PLANS AND SECTIONS" SHEETS FOR PANEL TYPES AND LOCATIONS. PDP-01_PANEL GEN NOTES. dgn APPROVED FOR USE BY UDOT PANEL PLANS - SKEWED PDP-6 STRUCTURES DI VI SI ON PRESTRESSED PANEL CONCRETE: f’ci = 4,000 PSI f’c = 5,000 PSI PDP-5 PI N CHECK THE STRUCTURAL CAPACITY OF THE EXISTING GIRDERS/ BEAMS AND/OR NEW GIRDERS/BEAMS FOR THE INSTALLATION OF THE PANELS (INCLUDING EFFECTS OF PANEL INSTALLATION SEQUENCING). USE OF THESE GUIDELINE DRAWINGS IMPLIES NO ASSERTION AS TO THE STRUCTURAL CAPACITY OF ANY GIRDERS OR BEAMS SHOWN. DEVELOP LOAD RATINGS AS DIRECTED BY UDOT. VERIFY ADEQUATE CAPACITY IN GIRDERS FOR THE EFFECTS OF LONG TERM POST-TENSIONING WHEN APPLICABLE. PANEL PLANS - NON-SKEWED PRECAST PANEL CONCRETE: f’c = 4,000 PSI CLASS AA(AE) PROJECT NUM BER MAX. OVERHANG = 4’-0" TYPICAL DECK PANEL PLANS AND SECTIONS PDP-4 DATE DESIGN AND CHECK ALL CHARACTERISTICS RELATED TO REQUIRED CLOSURE POURS. PDP-3 RECOM M . FOR PRESTRESSED PANELS: MAX. BEAM/GIRDER SPACING = 12’-0" PANELS DESIGNED FOR AN HL-93 LOAD INCLUDING A 40 PSF LOAD FOR FUTURE OVERLAY. GENERAL NOTES CALCULATE FINAL DECK ELEVATIONS AND CREATE TOP OF PANEL ELEVATIONS SHEET(S). GENERAL LAYOUTS DATE FOR PRECAST PANELS: MAX. BEAM/GIRDER SPACING = 10’-0" GENERAL NOTES PDP-2 NO. CREATE THE CONCRETE DECK PANEL LAYOUT SHEET SHOWING TYPE AND NUMBER OF PANELS TO BE USED AS WELL AS NUMBER AND SPACING OF SHEAR BLOCKOUTS REQUIRED. PDP-1 APPROVAL PARALLEL STEEL GIRDERS WITH A MINIMUM TOP FLANGE WIDTH OF 16"; AASHTO GIRDERS (TYPE II, III, IV, V AND VI); OR PRESTRESSED BULB TEE GIRDER. TANGENTIAL (NO HORIZONTAL CURVATURE) PANELS PLACED ORTHOGONALLY TO THE BEAM/GIRDERS. PRECAST CONCRETE PANELS DESIGNED IN ACCORDANCE WITH AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 4TH EDITION WITH ALL INTERIM PROVISIONS. TRANSPORTATI ON SKEW : 0 TO 45 DEGREES DESIGN AND CHECK THE REQUIRED SHEAR STUDS AND/OR REINFORCING STEEL CONNECTING THE GIRDERS/BEAMS TO THE DECK TO ENSURE ADEQUATE COMPOSITE ACTION BETWEEN THE FRAMING MEMBERS AND PANELS IN ACCORDANCE WITH ALL APPLICABLE CODES. INDEX OF SHEETS UTAH DEPARTM ENT OF IT IS THE DESIGNER’S RESPONSIBILITY TO: GENERAL NOTES FULL DEPTH PRECAST CONCRETE DECK PANELS USE THESE GUIDELINE DRAWINGS FOR BRIDGES WHICH HAVE ALL OF THE FOLLOWING CHARACTERISTICS: IMPLEMENTATION TYPI CAL DETAI L SHEET GUIDELINES CHECK CHECK CHECK REVI SI ON REM ARKS DESI GN FULL DEPTH PRECAST CONCRETE DECK PANELS GENERAL NOTES DRG. NO. SHT. OF P# P# P# P# P# P# EP# DRAW N 15^MAX. (TYP.) EP# P# P# P# P# P# P# P# P# BY STANDARD PANEL APPLICATIONS EP# UDOT DESI GN M ANAGER P# SENI OR DESI GN ENGI NEER EP# TRA NS V ERS E TRAFFIC QUANT. DIRECTION OF DESI GN LONGITUDINAL CHECK CHECK TRAFFIC TRANSVERSE CHECK DIRECTION OF REVI SI ON REM ARKS LONGITUDINAL P# P# P# P# P# 45^ MAX. (TYP.) STANDARD PANEL APPLICATIONS STANDARD PANEL APPLICATIONS SKEWED BRIDGES (BETWEEN 0 AND 15) SKEWED BRIDGES (GREATER THAN 15”) NON-STANDARD PANEL LAYOUT AND CONFIGURATION BY DESIGNER SIMILAR TO EP (SEE NOTE) STANDARD PRECAST CONCRETE PANEL APPLICATIONS - NON-SKEWED STANDARD PRECAST CONCRETE PANEL APPLICATIONS - SKEWED DATE APPROVED FOR USE BY UDOT APPROVAL RECOM M . STRUCTURES DI VI SI ON P# TRANSPORTATI ON P# UTAH DEPARTM ENT OF NO. DATE DATE NON - SKEWED BRIDGES PI N GENERAL LAYOUTS PROJECT NUM BER PDP-02_GENERAL LAYOUTS. dgn TYPI CAL DETAI L SHEET FULL DEPTH PRECAST CONCRETE DECK PANELS NOTE: PARTIAL WIDTH PANELS MAY BE USED IN COMBINATION WITH CLOSURE POURS. COUNTY 7/19/2010 PDP - 2 DRG. NO. SHT. OF P# P# P# A OVERHANG > BENT (OR INTERIOR DIAPHRAGM) > BRG. ABUT > BRG. ABUT TRANSVERSE JOINT (TYP.) QUANT. DRAW N UDOT DESI GN M ANAGER SENI OR DESI GN ENGI NEER P# > BENT (OR INTERIOR DIAPHRAGM) DATE P# PRECAST CONCRETE DECK PANEL (TYP.) 4’-0" MAX. 1’-0" MIN. OVERHANG 4’-0" MAX. A CHECK CHECK P# APPROVED FOR USE BY UDOT P# TRANSVERSE JOINT (TYP.) TRANSVERSE JOINT (TYP.) CHECK REVI SI ON REM ARKS DESI GN BY P# STRUCTURES DI VI SI ON PRECAST CONCRETE DECK PANEL (TYP.) EP# DATE P# RECOM M . P# DATE P# TRAFFIC NO. P# DIRECTION OF APPROVAL P# > GIRDER (TYP.) BY DESIGNER TRANSPORTATI ON P# A UTAH DEPARTM ENT OF P# P# OVERALL PANEL WIDTH EP# OVERHANG 4’-0" MAX. 40’-0" MAX. TO TRAFFIC 24’-0" MIN. DIRECTION OF PARAPET (IF APPLICABLE) (TYP.) TO BE DETERMINED AS SPECIFIED > GIRDER (TYP.) BY DESIGNER NOM INA L P ANE LEN L GTH 8’ MIN . 16’ MAX . GIRDER SPACING MAX. 1’-0" MIN. OVERHANG 4’-0" 40’-0" MAX. TO PARAPET (IF APPLICABLE) (TYP.) A AS SPECIFIED 24’-0" MIN. 16’ MAX. TO BE DETERMINED GIRDER SPACING OVERALL PANEL WIDTH NOMINAL PANEL LENGTH 8’ MIN. PRECAST CONCRETE PANEL TYPES PRECAST PANEL TYPES PANEL ADJACENT TO ABUTMENT P# STANDARD INTERIOR PANEL PANEL ADJACENT TO ABUTMENT P# STANDARD INTERIOR PANEL 3 DECK 8 4" PANEL PRECAST PARAPET EP# BLIND BLOCKOUT (TYP.) SEE LAYOUT FOR SLOPE PRECAST DECK PANEL 4" SEE DETAIL A THIS SHEET " 3 PDP-03_GENERAL PLANS AND SECTIONS. dgn " 4" " DETAIL A: DRIP GROOVE PRESTRESSED BULB TEE GIRDER (TYP.) PRECAST PARAPET (IF APPLICABLE) (TYP.) TYPI CAL DETAI L SHEET EP# STEEL GIRDER (TYP.) SECTION A: PRECAST DECK PANEL COUNTY 7/19/2010 PDP - 3 DRG. NO. SHT. PI N NOTE: NOMINAL JOINT SPACING SHOWN PRECAST PANEL TYPES PROJECT NUM BER SEE "PANEL PLANS - SKEWED" SHEET FOR ADDITIONAL INFORMATION TYPI CAL DECK PANEL PLANS AND SECTI ONS NOTE: NOMINAL JOINT SPACING SHOWN FULL DEPTH PRECAST CONCRETE DECK PANELS PRECAST CONCRETE PANEL TYPES SEE "PANEL PLANS - NON-SKEWED" SHEET FOR ADDITIONAL INFORMATION OF CHECK 3. FOR VERTICAL ADJUSTMENT DEVICES SEE "VERTICAL ADJUSTMENT DETAILS" SHEET. DRAW N DESI GN 4. FOR DETAILS OF BLIND BLOCKOUT SEE "SHEAR CONNECTOR BLOCKOUT DETAILS" SHEET. QUANT. CHECK REVI SI ON REM ARKS 2. A MINIMUM OF 2 VERTICAL ADJUSTMENT ASSEMBLIES ARE REQUIRED AT EACH > GIRDER. CHECK NOTES 1. DESIGNER WILL DETERMINE NUMBER AND LOCATION OF LIFTING POINTS. BY 6. SEE "TYPICAL POST-TENSIONING DETAILS 2" SHEET FOR CONNECTION DETAILS. > GIRDER VERTICAL ADJUSTMENT SEE "VERTICAL ADJUSTMENT DETAILS" SHEET (TYP. SEE NOTE 2) TO BLOCKOUT FOR POST-TENSIONING DUCT CONNECTION - SEE "TYPICAL POST-TENSIONING DETAILS" SHEETS (TYP. BOTH SIDES) > GIRDER DIRECTION OF DIRECTION OF TRAFFIC TRAFFIC VERTICAL ADJUSTMENT SEE "VERTICAL ADJUSTMENT DETAILS" SHEET (TYP. SEE NOTE 2) SEE PANEL REINFORCING SHEETS FOR REINFORCING REQUIREMENTS AT OVERHANG. 2’-0" MIN. (TYP.) LIFTING POINT SPACING LIFTING POINT SEE NOTE 1 (TYP.) PARAPET (WHERE APPLICABLE) ROUGHEN SURFACE UNDER PARAPET PANEL TYPE EP > GIRDER LIFTING POINT SPACING (TYP.) LIFTING POINT SPACING (TYP.) > GIRDER SEE PANEL REINFORCING SHEETS FOR REINFORCING REQUIREMENTS AT OVERHANG. 2’-0" MIN. (TYP.) LIFTING POINT SPACING LIFTING POINT SEE NOTE 1 (TYP.) PARAPET (WHERE APPLICABLE) ROUGHEN SURFACE UNDER PARAPET DATE APPROVED FOR USE STRUCTURES DI VI SI ON PANEL TYPE P COUNTY PDP - 4 7/19/2010 BY UDOT DATE PI N DUCT SPLICE POCKET SEE NOTE 6 (TYP.) PROJECT NUM BER BLOCKOUT FOR POST-TENSIONING END ANCHORAGE - SEE "TYPICAL POST-TENSIONING DETAILS" SHEETS (TYP. THIS SIDE) > GIRDER PANEL PLANS -NONSKEW ED > GIRDER > POST-TENSION DUCT (TYP.) FULL DEPTH PRECAST CONCRETE DECK PANELS > POST-TENSION DUCT (TYP.) 2" - 2" DIA. POST-TENSION DUCT (TYP.) TYPI CAL DETAI L SHEET 24’-0" MIN. 2" - 2" DIA. POST-TENSION DUCT (TYP.) > GIRDER 24’-0" MIN. > GIRDER BLIND BLOCKOUT SEE NOTE 4 (TYP.) OVERALL PANEL WIDTH BLIND BLOCKOUT SEE NOTE 4 (TYP.) RECOM M . DATE NO. 1’-6" (MIN.) OF TRANSPORTATI ON 1’-6" (MIN.) UTAH DEPARTM ENT 1’-6" (MIN.) 40’-0" MAX. 1’-6" OVERALL PANEL WIDTH PDP-04_TYPICAL PANEL PLANS. dgn > GIRDER (MIN.) TO 40’-0" MAX. > GIRDER APPROVAL 1’-6" 8’-0" MIN. TO 16’-0" MAX. (MIN.) NOMINAL PANEL LENGTH 1’-6" 8’-0" MIN. TO 16’-0" MAX. (MIN.) NOMINAL PANEL LENGTH BLOCKOUT FOR POST-TENSIONING DUCT SPLICE - SEE "TYPICAL POST-TENSIONING DETAILS" SHEETS (TYP. THIS SIDE) UDOT DESI GN M ANAGER SENI OR DESI GN ENGI NEER 5. SEE "PRECAST PANEL REINFORCING" AND "PRESTRESSED PANEL REINFORCING" SHEETS FOR REQUIRED REINFORCING. DRG. NO. SHT. OF DIRECTION OF DIRECTION OF LIFTING POINT SEE NOTE 1 (TYP.) PARAPET (WHERE APPLICABLE) ROUGHEN SURFACE UNDER PARAPET PANEL TYPE EP > GIRDER LIFTING POINT SPACING (TYP.) LIFTING POINT SPACING (TYP.) SEE PANEL REINFORCING SHEETS FOR REINFORCING REQUIREMENTS AT OVERHANG. 2’0" MIN . (TY P.) VERTICAL ADJUSTMENT SEE "VERTICAL ADJUSTMENT DETAILS 2" SHEET (TYP. SEE NOTE 2) TRAFFIC > GIRDER PDP-05_TYPICAL PANEL PLANS SKEW ED. dgn APPROVAL SEE PANEL REINFORCING SHEETS FOR REINFORCING REQUIREMENTS AT OVERHANG. 2’0" MIN . (TY P.) LIF TIN G POI NT SPA CIN G LIFTING POINT SEE NOTE 1 (TYP.) PARAPET (WHERE APPLICABLE) ROUGHEN SURFACE UNDER PARAPET PANEL TYPE P COUNTY PDP - 5 7/19/2010 QUANT. UDOT DESI GN M ANAGER RECOM M . DATE > GIRDER TRAFFIC LIF TIN G POI NT SPA CIN G NO. BLOCKOUT FOR POST-TENSIONING DUCT CONNECTION - SEE "TYPICAL POST-TENSIONING DETAILS" SHEET (TYP. BOTH SIDES) PI N OVERALL PANEL WIDTH > GIRDER VERTICAL ADJUSTMENT SEE "VERTICAL ADJUSTMENT DETAILS" SHEET (TYP. SEE NOTE 2) > GIRDER DUCT SPLICE POCKET SEE NOTE 6 (TYP.) PROJECT NUM BER > GIRDER BLOCKOUT FOR POST-TENSIONING END ANCHORAGE - SEE "TYPICAL POST-TENSIONING DETAILS" SHEET (TYP. THIS SIDE) > POST-TENSION DUCT (TYP.) PANEL PLANS -SKEW ED > POST-TENSION DUCT (TYP.) 2" - 2" DIA. POST-TENSION DUCT (TYP.) FULL DEPTH PRECAST CONCRETE DECK PANELS 24’-0" MIN. 2" - 2" DIA. POST-TENSION DUCT (TYP.) > GIRDER TO TO > GIRDER BLIND BLOCKOUT SEE NOTE 4 (TYP.) 24’-0" MIN. BLIND BLOCKOUT SEE NOTE 4 (TYP.) 40’-0" MAX. 1’6" (MI N.) OVERALL PANEL WIDTH 40’-0" MAX. 1’6" (MI N.) OF TRANSPORTATI ON > GIRDER (MI N.) UTAH DEPARTM ENT 1’6" > GIRDER (MI N.) TYPI CAL DETAI L SHEET 1’6" 1’-6" NOM INA L P ANE L L 8’ENG 0" TH MIN . T O 1 6’0" MAX . (MIN.) 1’-6" NOM INA L P ANE L L 8’ENG 0" TH MIN . T O 1 6’0" MAX . (MIN.) BLOCKOUT FOR POST-TENSIONING DUCT SPLICE - SEE "TYPICAL POST-TENSIONING DETAILS" SHEET (TYP. THIS SIDE) DATE BY SENI OR DESI GN ENGI NEER 6. SEE "TYPICAL POST-TENSIONING DETAILS 2" SHEET FOR CONNECTION DETAILS. DATE 5. SEE "PRECAST PANEL REINFORCING" AND "PRESTRESSED PANEL REINFORCING" SHEETS FOR REQUIRED REINFORCING. DRAW N DESI GN 4. FOR DETAILS OF BLIND BLOCKOUT SEE "SHEAR CONNECTOR BLOCKOUT DETAILS" SHEET. APPROVED FOR USE 3. FOR VERTICAL ADJUSTMENT DEVICES SEE "VERTICAL ADJUSTMENT DETAILS" SHEET. STRUCTURES DI VI SI ON 2. A MINIMUM OF 2 VERTICAL ADJUSTMENT ASSEMBLIES ARE REQUIRED AT EACH > GIRDER. BY UDOT REVI SI ON REM ARKS CHECK CHECK 1. DESIGNER WILL DETERMINE NUMBER AND LOCATION OF LIFTING POINTS. CHECK NOTES DRG. NO. SHT. OF NOM INA L P ANE 8’L L 0’ ENG MIN TH . T O 1 6’0" MAX , #5 BARS AVERAGE SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING > GIRDER #5 BARS AVERAGE SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING > GIRDER FRONT FACE OF PRECAST PARAPET (WHERE APPLICABLE) TYPI CAL DETAI L SHEET SKEWED INTERIOR MILD REINFORCED PANEL SEE "PARAPET DETAILS" SHEETS PARAPET (WHERE APPLICABLE) SEE "PARAPET DETAILS" SHEETS #5 @ 6" PARAPET REINFORCING. EXTEND 3’-0" PAST > GIRDER #4 @ 6" PARAPET REINFORCING. WITH STANDARD 90^ HOOK #6 @ 6" AVERAGE SPACING TOP AND BOTTOM W/ STD. 180^ HK. EA. END (TOP) SEE NOTE 1 > GIRDER 0" POST-TENSIONING DUCT (TYP.) 2" TO 2" DIA. BLIND BLOCKOUT (TYP.) #6 BARS SPACED @ 6" C-C 2" CL. AVERAGE SPACING TOP AND BOTTOM - SEE NOTE 1 4" CL. 4" CL. BLIND BLOCKOUT (TYP.) 4’-0" MAX. SHEAR KEY PANEL CONNECTION (TYP.) 3 8 4 1" CL. " 8" 8 3 4" VERTICAL ADJUSTMENT (TYP.) #6 @ 12" AVERAGE SPACING TOP AND BOTTOM SEE NOTE 1 1 2" 2 CL. 1 #6 @ 12" TOP AND BOTTOM SEE NOTE 1 2 2" > TRANSVERSE JOINT > TRANSVERSE JOINT SECTION D: PRECAST PANEL CHECK QUANT. DRAW N UDOT DESI GN M ANAGER DATE BY UDOT APPROVED FOR USE COUNTY SECTION C: PRECAST PANEL 7/19/2010 RECOM M . CL. SEE NOTE 2 OVERHANG PDP - 6 DRG. NO. SHT. PI N LIFTING POINT REINFORCING (BY OTHERS) INTERIOR PANEL REINFORCING PLAN PROJECT NUM BER #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING PRECAST PANEL REI NFORCI NG D FULL DEPTH PRECAST CONCRETE DECK PANELS FRONT FACE OF PARAPET (WHERE APPLICABLE) #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING D DATE BY DATE NO. C STRUCTURES DI VI SI ON > GIRDER D C OF TRANSPORTATI ON C D #6 BARS AVERAGE SPA. @ 12" C-C TOP AND BOTTOM > GIRDER UTAH DEPARTM ENT > GIRDER LIFTING POINT REINFORCING (BY OTHERS) DESI GN #6 BARS AVERAGE SPA. @ 6" C-C TOP AND BOTTOM > GIRDER 24’-0" MIN. #6 BARS AVERAGE SPA. @ 6" C-C TOP AND BOTTOM OVERALL PANEL WIDTH 24’-0" MIN. 4. CROWNED ROADWAYS REQUIRE A CLOSURE POUR AT THE CROWN. THIS WILL REQUIRE MULTIPLE PANELS IN A CROSS SECTION. SEE CROWN CLOSURE POUR DETAILS. TO #6 BARS AVERAGE SPA.@ 12" C-C TOP AND BOTTOM SEE NOTE 1 C #5 BARS AVERAGE SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING 40’-0" MAX. > GIRDER TO 40’-0" MAX. #5 BARS AVERAGE SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING > GIRDER PDP-06_PRECAST PANEL REINF. dgn CHECK 3. HOOK TOP BARS STD 180^ EACH END. FRONT FACE OF PRECAST PARAPET (WHERE APPLICABLE) OVERALL PANEL WIDTH 2. STEEL GIRDER SHOWN, PRESTRESSED BULB TEE GIRDERS ALLOWED. > GIRDER > GIRDER CHECK #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING 1. ADJUST LOCATION OF BARS TO AVOID CONFLICTS WITH BLOCKOUTS AS APPROVED BY DESIGNER. ROTATE #6 HOOKS TOP BARS TO PROVIDE ADEQUATE COVER. SENI OR DESI GN ENGI NEER #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING APPROVAL 8’-0’ MIN. TO 16’-0" MAX, NOTES REVI SI ON REM ARKS FRONT FACE OF PARAPET (WHERE APPLICABLE) NOMINAL PANEL LENGTH OF > GIRDER #5 BARS SPACED @ 6" C-C > GIRDER ADDITIONAL #6 @ 6" OVERHANG REINF. EXTEND 8’-3" PAST > GIRDER, SEE NOTE 3 > GIRDER FRONT FACE OF PARAPET (WHERE APPLICABLE) #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING F F #4 BARS AVG. SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING LIFTING POINT REINFORCING (BY OTHERS) INTERIOR PANEL REINFORCING PLAN NON - SKEWED SKEWED INTERIOR PRESTRESSED REINFORCED PANEL SEE "PARAPET DETAILS" SHEET PARAPET (WHERE APPLICABLE) SEE "PARAPET DETAILS" SHEETS #5 @ 6" PARAPET REINF. EXTEND 7’-3" PAST > GIRDER #4 @ 6" PARAPET REINF. WITH STANDARD 90^ HOOK ADDITIONAL #6 @ 6" OVERHANG REINF. WITH STANDARD 180^ HOOK EXTEND 8’-3" PAST > GIRDER, SEE NOTE 3 0.600" DIA. PRESTRESSING STRANDS AVG. SP. @ 12" C-C TOP AND BOTTOM. SEE NOTE 1 BLIND BLOCKOUT (TYP.) 4" CL. 12" 2" CL. 0.600" DIA. PRESTR. STRANDS SPACED @ 12" 12" 4" CL. AVERAGE SPACING TOP AND BOTTOM - SEE NOTE 1 4" 3 VERTICAL ADJUSTMENT (TYP.) 1" CL. SHEAR KEY PANEL CONNECTION (TYP.) 8 8" 3 3 BLIND BLOCKOUT (TYP.) 4" 8 PDP-07_PRESTR PANEL REINF. dgn 0" 4 4’-0" MAX. POST-TENSIONING 2" TO 2" DIA. DUCT (TYP.) 2 OVERHANG 1 2" CL. SEE NOTE 2 #6 @ 12" AVG. SP. C-C TOP AND BOTTOM SEE NOTE 1 > TRANSVERSE JOINT #6 @ 12" AVERAGE SPACING TOP AND BOTTOM SEE NOTE 1 SECTION E: PRESTRESSED PANEL 1 2 2" 7/19/2010 CHECK DRAW N UDOT DESI GN M ANAGER BY UDOT DATE CL. > TRANSVERSE JOINT COUNTY SECTION F: PRESTRESSED PANEL QUANT. CHECK SENI OR DESI GN ENGI NEER DATE RECOM M . FRONT FACE OF PARAPET (WHERE APPLICABLE) PDP - 7 DRG. NO. PORTION OF DECK PANEL SHOWN. REMAINDER SIMILAR. SHT. PI N ADDITIONAL #6 @ 6" OVERHANG REINF. EXTEND 8’-3" PAST > GIRDER, SEE NOTE 3 DESI GN BY DATE NO. E E APPROVED FOR USE 40’-0" MAX. > GIRDER TRAFFIC LIFTING POINT REINFORCING (BY OTHERS) #6 BARS AVG. SPA. @ 12" C-C TOP AND BOTTOM SEE NOTE 1 PROJECT NUM BER #5 BARS SPACED @ 6" C-C DIRECTION OF F PRESTRESSED PANEL REI NFORCI NG > GIRDER > GIRDER APPROVAL 0.600" DIA. PRESTRESSING STRANDS AVG. SPA. @ 12" C-C TOP AND BOTTOM 0.600" DIA. PRESTRESSING STRANDS AVG. SPA. @ 12" C-C TOP AND BOTTOM OF TRANSPORTATI ON OVERALL PANEL WIDTH > GIRDER 3. CROWNED ROADWAYS REQUIRE A CLOSURE POUR AT THE CROWN. THIS WILL REQUIRE MULTIPLE PANELS IN A CROSS SECTION. SEE CROWN CLOSURE POUR DETAILS. UTAH DEPARTM ENT F 24’-0" MIN. TO #6 BARS AVERAGE SPA.@ 12" C-C TOP AND BOTTOM SEE NOTE 1 #5 BARS AVG. SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING OVERALL PANEL WIDTH 40’-0" MAX. 24’-0" MIN. TO E E CHECK 2. STEEL GIRDER SHOWN, PRESTRESSED BULB TEE GIRDERS ALLOWED. ADDITIONAL #6 @ 6" OVERHANG REINF. EXTEND 8’-3" PAST > GIRDER, SEE NOTE 3 > GIRDER 1. ADJUST LOCATION OF BARS AND STRANDS TO AVOID CONFLICTS WITH BLOCKOUTS AS APPROVED BY DESIGNER. STRUCTURES DI VI SI ON > GIRDER #5 BARS AVERAGE SPA. @ 6" C-C RUN FROM REAR FACE OF PARAPET TO TOP MAT OF PANEL REINFORCING NOTES ADDITIONAL #6 @ 6" OVERHANG REINF. EXTEND 8’-3" PAST > GIRDER, SEE NOTE 3 FRONT FACE OF PARAPET (WHERE APPLICABLE) > GIRDER #4 BARS AVG. SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING REVI SI ON REM ARKS FRONT FACE OF PARAPET (WHERE APPLICABLE) FULL DEPTH PRECAST CONCRETE DECK PANELS 8’-0’ MIN. TO 16’-0" MAX, NOM INA L P ANE 8’L L 0’ ENG MIN TH . T O 1 6’0" MAX , TYPI CAL DETAI L SHEET #4 BARS AVERAGE SPA. @ 6" C-C RUN FROM FRONT FACE OF PARAPET TO BOTTOM MAT OF PANEL REINFORCING NOMINAL PANEL LENGTH OF > TRANSVERSE JT. CLOSURE POUR PLAN CLOSURE POUR CHECK DRAW N QUANT. CHECK UDOT DESI GN M ANAGER DATE DATE DATE APPROVED FOR USE BY UDOT STRUCTURES DI VI SI ON 7. FOR STAGE CONSTRUCTION CLOSURE POURS, PLACE CONCRETE AFTER LONGITUDINAL POST-TENSIONING. NO. 6. THE MINIMUM LAP SPLICE LENGTH SHOWN IS BASED ON THE FOLLOWING PARAMETERS: - #6 @ 6" - f’c = 4 KSI - 2" CLEAR COVER - TENSION LAP WITH 100% OF BAR SPLICED - CLASS C SPLICE - AASHTO LRFD SPECIFICATIONS - COATED BARS FOR BOTTOM BARS WITH 1" CLEAR COVER, INCREASE THIS SPLICE LENGTH TO 3’-10". DESIGNER TO ADJUST LENGTH OF SPLICE FOR DESIGNS BEYOND THESE PARAMETERS. BY 5. CLOSURE POURS CAN BE USED FOR: - ROADWAY CROWNS - STAGE CONSTRUCTION JOINTS - BRIDGES GREATER THAN 40 FT WIDE - BRIDGE WIDENING PROJECTS SENI OR DESI GN ENGI NEER 4. DESIGNER TO CHECK OVERHANG REINFORCING FOR ANTICIPATED LOADS. G CLOSURE POUR PLAN REVI SI ON REM ARKS 3. AS AN ALTERNATIVE TO EMBEDDING BARS IN PRESTRESSED PANELS, THREADED INSERTS MAY BE ALLOWED AS DIRECTED BY THE DESIGNER. IN PRECAST PANELS WITHOUT PRESTRESSING, PANEL REINFORCEMENT, TOP AND BOTTOM, WILL BE CONTINUED INTO THE CLOSURE POUR. 8. FOR NON-STAGE CONSTRUCTION LONGITUDINAL CLOSURE POURS, CONCRETE MAY BE PLACED AFTER POST-TENSIONING. G DESI GN 2. PRECAST PANELS SHOWN, FOR PRESTRESSED PANELS, ADD DOWEL BARS EMBEDDED IN THE PANELS EXTENDING INTO THE CLOSURE POUR. THE LENGTH OF EMBEDMENT AND EXTENSION INTO THE CLOSURE POUR TO BE BASED ON THE LENGTH REQUIRED TO ACHIEVE A LAP SPLICE. UTAH DEPARTM ENT OF PANEL CLOSURE POUR PRECAST CONC. CAST-IN-PLACE PANEL > GIRDER PRECAST CONC. MAX. 6" 2" MIN. #6 @ 12" 2" MIN. EDGE OF PANELS LONG.BARS SPLICE TYP. PANEL REINF. EXTEND TO ACHIEVE REQ’D LAP SPLICE SEE NOTE 1 (TYP.) LAP EDGE OF PANELS 3’-1" MIN. TRAFFIC 6" MAX. PANEL DIRECTION OF CLOSURE POUR CAST-IN-PLACE > GIRDER PANEL MAX. PRECAST CONC. > GIRDER MIN. EDGE OF PANELS 6" #6 TYP. PANEL REINF. EXTEND TO ACHIEVE REQ’D LAP SPLICE SEE NOTE 1 (TYP.) 2" EDGE OF PANELS @ 12" TRAFFIC 6" MAX. DIRECTION OF LONG.BARS 2" MIN. > GIRDER PRECAST CONC. 1. MINIMUM REINFORCEMENT SHOWN. IT IS THE RESPONSIBILITY OF THE DESIGNER TO DETERMINE THE ACTUAL REINFORCEMENT REQUIRED. DESIGN AND DETAIL CLOSURE POUR FOR BEAM SPACINGS GREATER THAN 10’-0", AND APPROPRIATE POST-TENSIONING AS REQUIRED. CHECK NOTES > TRANSVERSE JT. G RECOM M . > TRANSVERSE JT. APPROVAL G TRANSPORTATI ON > TRANSVERSE JT. 6" MAX. 6" MAX. EXISTING DECK 3’-1" MIN. LAP SPLICE SEE NOTE 4 3’-1" MIN. 2" MIN. LAP SPLICE #6 @ 12" LONG. BARS LEVEL 2" MIN. 6" MAX. 6" MAX. SECTION G: CLOSURE POUR SECTION AT CROWN TYPICAL PANEL REINF. (OR ADDITIONAL PANEL REINF. FOR PRESTRESSED PANELS) EXTEND TO ACHIEVE REQ’D LAP SPLICE (TYP.) 2’-0" CLOSURE POUR LAP SPLICE SEE NOTES BELOW TYP. PANEL REINF. (OR ADDITIONAL PANEL REINF. FOR PRESTRESSED PANELS) EXTEND TO ACHIEVE REQ’D LAP SPLICE (TYP.) (SHOWING STEEL GIRDERS) 4" 1" CL. 3 2 PDP-08_CLOSURE POUR. dgn 7/19/2010 > GIRDER > GIRDER > GIRDER CLOSURE POUR TO EXISTING DECK SECTION #6 @ 12" CL. FOR CLOSURE POUR AT CROWN SEE DETAIL THIS SHEET EXISTING DECK REINF. BAR (TO REMAIN) SEE NOTE 3 LEVEL > CLOSURE POUR PRECAST DECK PANEL (TYP.) SECTION G: CLOSURE POUR SUPERELEVATED SECTION SECTION G: OPTIONAL CLOSURE POUR (SHOWING STEEL GIRDERS) SHOWING SECTION AT CROWN - SECTION AT OTHER LOCATIONS SIMILAR TYPI CAL DETAI L SHEET 6" MAX. SEE NOTE 4 2" MIN. #6 @ 12" LONG. BARS PROTECT EXISTING REINFORCING BARS WHEN REMOVING THE PORTION OF EXISTING DECK. BEFORE MAKING THE CLOSURE POUR, ALL EXISTING REINFORCING IS TO BE CLEANED OF RUST AND FOREIGN MATERIAL. RECOAT BAR IF ORIGINAL WAS EPOXY COATED AND DAMAGED. REPAIR OR REPLACE ANY EXISTING REBAR DAMAGED DURING THE REMOVAL OF CONCRETE. NOTES: 1. HOOKED BARS ARE REQUIRED IN TENSILE ZONES (TOP NEAR GIRDERS, BOTTOM NEAR MID-BAY). 2. HOOKED BARS ARE NOT REQUIRED IN COMPRESSION ZONES (BOTTOM NEAR GIRDERS, TOP NEAR MID-BAY). 3. ROTATE HOOKS TO PROVIDE REQUIRED COVER. 4. LAP SPLICE IN COMPRESSION ZONES TO BE 22 IN. PI N 2" MIN. PROJECT NUM BER CLOSURE POUR #6 @ 12" LONG. BARS CLOSURE POUR DETAI LS CLOSURE POUR 2" MIN. FULL DEPTH PRECAST CONCRETE DECK PANELS 3’-1" MIN. LAP SPLICE COUNTY PDP - 8 DRG. NO. SHT. OF PLATE 15"X11"x" PLACE AT LEAST TWO MAIN BARS OVER TOP OF POCKET 2" GROUT PORT " VENT TUBE CHECK HSS 14"X10"X" 14" BY > GIRDER & BLOCKOUT UDOT DESI GN M ANAGER SEAL WELD (TYP.) #6 @ 6" TOP AND BOTTOM (TYP.) 10" QUANT. DRAW N #6 @ 12" TOP AND BOTTOM (TYP.) SENI OR DESI GN ENGI NEER HSS 14"X10"X" #6 @ 6" TOP AND BOTTOM (TYP.) 2" GROUT PORT CHECK 2" 1 1 2" SEAL WELD (TYP.) 4 PLATE 15"X11"x" R 15" 11" HSS 14"X10"X" PLACE AT LEAST TWO MAIN BARS OVER TOP OF BLOCKOUT DESI GN S S GROUT VENT AND PORT PLATE 15"X11"x" 4 R > GIRDER & BLOCKOUT > BLOCKOUT REVI SI ON REM ARKS BLIND BLOCKOUT CHECK " VENT TUBE 3 4" 8 CONCRETE DECK PANEL U U 1 2" 5" 4" 8 1 3 4" 2" T CONCRETE DECK PANEL > GIRDER 1’-4" MAX. T 4" > GIRDER SECTION T SECTION U " VENT TUBE V BLIND BLOCKOUT > GIRDER & BLOCKOUT > BLOCKOUT PLACE AT LEAST TWO MAIN BARS OVER TOP OF POCKET 2" GROUT PORT 15" 1 1 2" 2" 11" #6 @ 12" TOP AND BOTTOM (TYP.) 4 4 PDP-09_BLOCKOUT DETAILS. dgn V 2" GROUT PORT PLACE AT LEAST TWO MAIN BARS OVER TOP OF BLOCKOUT " VENT TUBE W W GROUT VENT AND PORT TYPI CAL DETAI L SHEET OPTIONAL SHEAR STUD BLOCKOUT PLAN WITH SHEAR STUDS #6 @ 6" TOP AND BOTTOM (TYP.) 10" #6 @ 6" TOP AND BOTTOM (TYP.) DATE APPROVED FOR USE BY UDOT 14" > GIRDER & BLOCKOUT OPTIONAL BLIND BLOCKOUT PLAN COUNTY SECTION V 7/19/2010 STRUCTURES DI VI SI ON 1’-5" MAX. 5" NOTES: 1. REINFORCEMENT NOT SHOWN FOR CLARITY. 2. METHOD OF FORMING BLOCKOUT AND PORTS BY FABRICATOR. 3. USE PLASTIC PIPE FOR PORTS AND VENT TUBES. SECTION W PDP - 9 DRG. NO. SHT. PI N 1 2" PROJECT NUM BER 1’-4" MAX SHEAR CONNECTOR BLOCKOUT DETAI LS 2" RECOM M . DATE NO. UTAH DEPARTM ENT OF 1 FULL DEPTH PRECAST CONCRETE DECK PANELS 1’-5" MAX APPROVAL SECTION S NOTES: 1. REINFORCEMENT NOT SHOWN FOR CLARITY. 2. GALVANIZE STEEL FOR BLOCKOUTS 3. USE PLASTIC PIPE FOR PORTS AND VENT TUBES. TRANSPORTATI ON SECTION R DATE TYPICAL BLIND BLOCKOUT PLAN OF 3. USE A HEAVY BROOM FINISH ON TOP SURFACE OF DECK. 5. FOR SKEWED PANELS, ROTATE BLOCKOUTS TO BE PARALLEL WITH THE PANEL REINFORCING. I PLAN: SHEAR STUD CONNECTOR BULB TEE GIRDERS: OPTION 2 5" STEEL PLATE CAST INTO BEAM SEE GIRDER STANDARDS FOR DETAILS NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED FILL BLIND BLOCKOUT WITH NON-SHRINK GROUT M SHEAR STUD WELDED TO TOP FLANGE (TYP.) 3 4" 8 CONCRETE DECK PANEL FILL BLOCKOUT WITH NON-SHRINK GROUT 4" 4" 3 8 CONCRETE DECK PANEL L SECTION K: OPTION 2 SHEAR STUD (TYP.) SHEAR STUD (TYP.) FORM HAUNCH AND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING HAUNCH TO BE DETERMINED BY THE CONTRACTOR. REMOVE FORMS AFTER 24 HOURS. > GIRDER GIRDER TOP FLANGE UDOT DESI GN M ANAGER SENI OR DESI GN ENGI NEER DATE STRUCTURES DI VI SI ON APPROVED FOR USE BY UDOT RECOM M . APPROVAL NO. BULB TEE GIRDER SECTION J: OPTION 2 SHEAR STUD (TYP.) L 4" 4" 3 12" (TYP.) GIRDER TOP FLANGE NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED BLIND BLOCKOUT SEE DETAILS FORM HAUNCH AND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING HAUNCH TO BE DETERMINED BY THE CONTRACTOR. REMOVE FORMS AFTER 24 HOURS. EXPANDED POLYSTYRENE MAY BE USED TO FORM HAUNCH (TYP.) 4" > GIRDER PDP-10_SHEAR CONNECTOR NEW . dgn 8 SHEAR STUD WELDED TO EMBEDDED PLATE IN BULB TEE GIRDER (TYP.) J M CONCRETE DECK PANEL K SHEAR STUD (TYP.) TROWEL SMOOTH APPLY BOND BREAKER (TYP.) 4" 8 3 BLIND BLOCKOUT SEE DETAILS CONCRETE DECK PANEL 4" J FILL BLOCKOUT WITH NON-SHRINK GROUT SECTION M PLAN: STEEL GIRDER DETAILS NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED SECTION L NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED COUNTY 7/19/2010 PDP - 10 DRG. NO. SHT. PI N FILL BLIND BLOCKOUT WITH NON-SHRINK GROUT PROJECT NUM BER NOTE: ONE BAR SHOWN. MULTIPLE BARS MAY BE USE AND BUNDLED TO PROVIDE ADEQUATE SHEAR RESISTANCE. SHEAR CONNECTOR DETAI LS NEW GI RDERS #5 U-SHAPED SHEAR BAR SECTION I: OPTION 1 UTAH DEPARTM ENT OF BULB TEE GIRDER TRANSPORTATI ON 12" (TYP.) PLAN: U-SHAPED SHEAR BAR BULB TEE GIRDERS: OPTION 1 SHEAR STUD (TYP.) DATE EXPANDED POLYSTYRENE MAY BE USED TO FORM HAUNCH (TYP.) #5 U-SHAPED SHEAR BAR EMBEDDED IN PRESTRESSED SECTION H: OPTION 1 CONCRETE GIRDER (TYP.) NOTE: ONE BAR SHOWN. MULTIPLE BARS MAY BE USE AND BUNDLED TO PROVIDE ADEQUATE SHEAR RESISTANCE. DATE GIRDER TOP FLANGE > GIRDER K BY 8 4" 3 4" CONCRETE DECK PANEL FORM HAUNCH AND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING HAUNCH TO BE DETERMINED BY THE CONTRACTOR. REMOVE FORMS AFTER 24 HOURS. FULL DEPTH PRECAST CONCRETE DECK PANELS H 6. BLIND BLOCKOUTS FORMED WITH STEEL BOX SHOWN. OPTIONAL FORMED BLOCKOUTS SIMILAR. TYPI CAL DETAI L SHEET I 4" 8 H 3 4" BLIND BLOCKOUT SEE DETAILS CONCRETE DECK PANEL FILL BLOCKOUT WITH NON-SHRINK GROUT FILL BLOCKOUT WITH NON-SHRINK GROUT TROWEL SMOOTH APPLY BOND BREAKER (TYP.) DRAW N DESI GN 4. DESIGNER TO DETERMINE AND DETAIL THE MINIMUM SPACING OF SHEAR STUDS AND SHEAR BARS. QUANT. REVI SI ON REM ARKS 2. INCLUDE COST OF ALL NON-SHRINK GROUT IN THE COST OF THE PRESTRESSED CONCRETE DECK PANEL. #5 U-SHAPED SHEAR BAR CHECK CHECK 1. INCLUDE COST OF WELDED STUD SHEAR CONNECTORS IN THE COST OF THE PRESTRESSED CONCRETE DECK PANEL. INCLUDE COST OF THE U-SHAPED REINFORCING BARS IN THE COST OF THE PRESTRESSED CONCRETE GIRDER. CHECK NOTES OF 2. INCLUDE COST OF ALL NON-SHRINK GROUT IN THE COST OF THE PRESTRESSED CONCRETE DECK PANEL. 4. FOR SKEWED PANELS, ROTATE BLOCKOUTS TO BE PARALLEL WITH THE PANEL REINFORCING. CHECK DRAW N DESI GN 3. USE A HEAVY BROOM FINISH ON TOP SURFACE OF DECK. QUANT. REVI SI ON REM ARKS 1. INCLUDE COST OF WELDED STUD SHEAR CONNECTORS AND T-STUD SHEAR CONNECTORS IN THE COST OF THE PRESTRESSED CONCRETE DECK PANEL. CHECK CHECK NOTES > GIRDER GIRDER TOP FLANGE PLAN: STEEL GIRDER DETAILS SECTION P 4" 8 FORM HAUNCH AND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING HAUNCH TO BE DETERMINED BY THE CONTRACTOR. REMOVE FORMS AFTER 24 HOURS. SECTION Q 5 NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED 8" 1 NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED 2 4" SQ. STEEL PLATE PDP-11_SHEAR CONNECTOR EXISTING. dgn #6 REINFORCING BAR (A706) T-HEADED REINFORCING BAR DETAIL UDOT DESI GN M ANAGER DATE STRUCTURES DI VI SI ON APPROVED FOR USE BY UDOT RECOM M . COUNTY 7/19/2010 PDP - 11 DRG. NO. SHT. OF PI N SHEAR STUD WELDED TO TOP FLANGE (TYP.) P 3 4" Q Q CONCRETE DECK PANEL 4" 4" 3 8 BLIND BLOCKOUT SEE DETAILS CONCRETE DECK PANEL P SHEAR STUD (TYP.) FILL BLOCKOUT WITH NON-SHRINK GROUT PROJECT NUM BER SHEAR STUD DATE BY DATE FILL BLIND BLOCKOUT WITH NON-SHRINK GROUT APPROVAL NO. SECTION O SHEAR CONNECTOR DETAI LS EXI STI NG GI RDERS NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED TRANSPORTATI ON APPROVED EPOXY ANCHORAGE TO DEVELOP MIN. YIELD STRENGTH OF THE BAR (TYP.) SECTION N NOTE:ONE ROW OF CONNECTORS SHOWN. MULTIPLE ROWS MAY BE USED UTAH DEPARTM ENT OF CONTRACTOR TO VERIFY THE LOCATION. CONTRACTOR IS NOT TO DAMAGE THE EXISTING PRESTRESSING STRANDS. EXISTING GIRDER PLAN: T-HEADED SHEAR STUD CONNECTOR ON CONCRETE GIRDERS 8 3 4" 1 8 #6 T-HEADED REINFORCING BAR EXISTING GIRDER TOP FLANGE FULL DEPTH PRECAST CONCRETE DECK PANELS > GIRDER EXPANDED POLYSTYRENE MAY BE USED TO FORM HAUNCH (TYP.) MIN. N 2" #6 T-HEADED REINFORCING BAR (TYP.) EMBEDDED IN PRESTRESSED CONCRETE GIRDER. TYPI CAL DETAI L SHEET O O 4" 8 3 4" BLIND BLOCKOUT SEE DETAILS #6 T-HEADED REINFORCING BAR (TYP.) CONCRETE DECK PANEL N FORM HAUNCHAND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING HAUNCH TO BE DETERMINED BY THE CONTRACTOR. REMOVE HAUNCH FORMS AFTER 24 HOURS. CONCRETE DECK PANEL FILL BLIND BLOCKOUT WITH NON-SHRINK GROUT FILL BLIND BLOCKOUT WITH NON-SHRINK GROUT SENI OR DESI GN ENGI NEER 5. BLIND BLOCKOUTS FORMED WITH STEEL BOX SHOWN. OPTIONAL FORMED BLOCKOUTS SIMILAR. 1" 4"x4"x" 20 K 1" 4"x4"x" CHECK DRAW N SENI OR DESI GN ENGI NEER DATE COUNTY 7/19/2010 PDP - 12 DRG. NO. SHT. BY UDOT APPROVED FOR USE RECOM M . DATE APPROVAL NO. PDP-12_VERTICAL ADJUSTM ENT. dgn TYPI CAL DETAI L SHEET 10 K STRUCTURES DI VI SI ON STEEL PLATE WITH HOLE FOR BOLT CENTERED PI N BOLT DIA. PROJECT NUM BER SERVICE LOAD VERTI CAL ADJUSTM ENT DETAI LS VERTICAL ADJUSTMENT SCHEDULE FULL DEPTH PRECAST CONCRETE DECK PANELS VERTICAL ADJUSTMENT DETAIL ON CONCRETE GIRDER UTAH DEPARTM ENT "X6"X6" PLATE VERTICAL ADJUSTMENT DETAIL ON STEEL GIRDER DATE STEEL PLATE WITH HOLE FOR BOLT CENTERED (SEE TABLE) HEAVY HEX NUT WELDED TO PLATE HEAVY HEX NUT WELDED TO PLATE QUANT. CHECK DESI GN BY HAUNCH FILLED WITH NON-SHRINK GROUT STEEL PLATE WITH HOLE FOR BOLT CENTERED (SEE TABLE) HAUNCH EXPANDED POLYSTYRENE MAYBE USED TO FORM HAUNCH (TYP.) OF TRANSPORTATI ON HAUNCH FILLED WITH NON-SHRINK GROUT 1" MIN. 1" MIN. EXPANDED POLYSTYRENE MAYBE USED TO FORM HAUNCH (TYP.) HAUNCH (2) #5 BARS WITH 15" EXTENSION PAST END OF PLATE (2) #5 BARS WITH 15" EXTENSION PAST END OF PLATE UDOT DESI GN M ANAGER " REINFORCING STEEL WELDED TO PLATE MIN. 1" STEEL PIPE SLEEVE FORMED POCKET 2 3 4" 8 CONCRETE DECK PANEL " REINFORCING STEEL WELDED TO PLATE MIN. 1" STEEL PIPE SLEEVE FILL VOID WITH NON-SHRINK GROUT FORMED POCKET 2 3 4" 8 CONCRETE DECK PANEL FILL VOID WITH NON-SHRINK GROUT CHECK LEVELING BOLT (SEE SCHEDULE) REVI SI ON REM ARKS LEVELING BOLT (SEE SCHEDULE) OF SHOWING OPTIONAL SHEAR SHOWING BLIND BLOCKOUT SHOWING OPTIONAL SHEAR THE DESIGN OF POST-TENSIONING IS BASED ON THE FOLLOWING PARAMETERS: AA GENERAL ANCHORAGE ZONE REINF. CHECK QUANT. DRAW N DATE UDOT DESI GN M ANAGER SENI OR DESI GN ENGI NEER DATE APPROVED FOR USE RECOM M . BY UDOT CHECK CHECK DESI GN DATE NO. > INT. GIRDER, BLOCKOUT AND LEVELING DEVICE STRUCTURES DI VI SI ON > INT. GIRDER, BLOCKOUT AND LEVELING DEVICE UTAH DEPARTM ENT BB GENERAL ANCHORAGE ZONE REINF. BY N. ) > POST-TENSION DUCT AA REVI SI ON REM ARKS N.) 1 ’6" (MI " ( MAX .) 4’0 EE > POST-TENSION DUCT N. ) (MA 3’0 "¨ EE LOCAL ANCHORAGE ZONE REINF. (MI 2" TO 2" DIA. POST-TENSIONING DUCT (TYP.) X.) > POST-TENSION DUCT 3’-0"¨ LOCAL ANCHORAGE ZONE REINF. 1 ’9" BB (TYP.) 2" TO 2" DIA. POST-TENSIONING DUCT (TYP.) BLIND BLOCKOUT OVER GIRDER (TYP.) > GIRDER, BLOCKOUT & LEVELING DEVICE DD (MAX.) DD > POST-TENSION DUCT VERTICAL ADJUSTMENT SEE DETAIL OPTIONAL SHEAR STUD BLOCKOUT (SEE SHEAR STUD DETAILS TYP.) (MI 1’-9" > GIRDER, BLOCKOUT & LEVELING DEVICE TRANSISTION FROM FLAT ANCHORAGE TO ROUND DUCT > POST-TENSION DUCT (MIN.) (MIN.) BLIND BLOCKOUT OVER GIRDER (TYP.) VERTICAL ADJUSTMENT SEE DETAIL 4’-0" (MAX.) 1’-6" > POST-TENSION DUCT END OF PANEL (TYP.) APPROVAL TRANSISTION FROM FLAT ANCHORAGE TO ROUND DUCT END OF PANEL (TYP.) OPTIONAL SHEAR STUD BLOCKOUT (SEE SHEAR STUD DETAILS TYP.) SHOWING BLIND BLOCKOUT STUD BLOCKOUT OF TRANSPORTATI ON STUD BLOCKOUT COEFFICIENT OF FRICTION = 0.XX SEE POST-TENSION END ANCHORAGE DETAILS THIS SHEET 2 " CLEAR SEE NOTE 8 8 3 4" > POST-TENSION DUCT SHOWING SHEAR KEY PANEL CONNECTION > JOINT " CL. 2 MIN. (TYP.) > POST-TENSION DUCT 3. GALVANIZE BEARING PLATE ANCHOR HEADS AND METAL TRUMPETS AT ANCHORAGES. DO NOT GALVANIZE STRAND GRIPPING WEDGES. 5. DECK PANELS MUST BE ALLOWED TO SLIDE ON GIRDERS DURING POST-TENSIONING. > POST-TENSION DUCT 6. THE CONTRACTOR IS RESPONSIBLE FOR DESIGN OF ALL POST-TENSIONING ELEMENTS AND ANCHORAGE ZONE REINFORCEMENT (REQUIRED FOR SPLITTING, BURSTING, SPALLING, ETC.). DESIGN MUST CONFORM WITH AASHTO LRFD SPECIFICATIONS. TYPICAL REINFORCING FOR TWO DIFFERENT MANUFACTURERS ARE SHOWN. MIN. (TYP.) > POST-TENSION DUCT AND END ANCHOR BLOCKOUT 2" CL. 4" 3 2. USE 4 STRANDS PER DUCT MAXIMUM. 4. BEGIN STRESSING AT CENTER OF PANELS. DO NOT ALLOW MORE THAN 12.5% OF THE PRESTRESSING FORCE TO BE ECCENTRIC AT ANY TIME. SUBMIT STRESSING SEQUENCE TO ENGINEER FOR APPROVAL PRIOR TO WORK. CONCRETE DECK PANEL 8 MIN. (TYP.) BLIND BLOCKOUT WITH OR WITHOUT STEEL FORMING BOX 2" CL. OPTIONAL SHEAR STUD BLOCKOUT SECTION AA: TYPICAL TRANSVERSE PANEL SECTION PDP-13_POST-TENSION DETAILS 1. dgn POST-TENSIONING NOTES: 1. USE 0.5" DIA. GRADE 270 LOW RELAXATION STRANDS CONFORMING TO ASTM A416. > JOINT POST-TENSIONING DUCT 2" TO 2 " DIA. BEYOND ANCHORAGE (TYP.) SECTION BB: TYPICAL LONGITUDINAL PANEL SECTION 7/19/2010 CONCRETE DECK PANEL SEE POST-TENSIONING DUCT SPLICE DETAILS THIS SHEET TYPI CAL DETAI L SHEET 7. SEQUENCE OF CONSTRUCTION: A. ERECT DECK PANELS. B. ADJUST PANELS TO GRADE USING LEVELING DEVICES. C. INSTALL POST-TENSIONING STRAND LOOSE IN DUCTS. D. PLACE GROUT IN TRANSVERSE JOINTS ONLY. CURE TO 500 PSI. E. STRESS POST-TENSIONING STRAND AFTER GROUT ATTAINS A STRENGTH OF 500 PSI. F. GROUT POST-TENSIONING DUCTS. G. GROUT SHEAR CONNECTOR POCKETS AND CAMBER STRIPS. H. LEVELING BOLTS MAY BE REMOVED. GROUT BOLT RECESS. I. PLACE CLOSURE POURS. COUNTY PDP - 13 8. ANCHORAGE ASSEMBLY AND DUCTS MAY BE LOWERED UP TO " FROM CENTER OF SLAB IN ORDER TO PROVIDE 2" TOP COVER FOR REINFORCING ABOVE THE DUCT. DRG. NO. SHT. PI N IF THE PROPOSED DUCT DOES NOT MEET THESE VALUES, THEN THE CONTRACTOR TO ADJUST THE JACKING FORCE TO PRODUCE THE FINAL POST-TENSIONING FORCE LISTED. SHOWING BLIND BLOCKOUT PROJECT NUM BER P-FINAL PER STRAND = XX.X KIPS (AFTER LOSSES DUE TO FRICTION, ANCHORAGE SET, AND ELASTIC SHORTENING). NOMINAL PANEL WIDTH 8’-0" MIN. TO 16’-0" MAX. SHOWING OPTIONAL SHEAR STUD BLOCKOUT P-JACKING PER STRAND = XX.X KIPS. TYPI CAL POSTTENSI ONI NG DETAI LS 1 SKEWED POST-TENSION END ANCHORAGE DETAIL FULL DEPTH PRECAST CONCRETE DECK PANELS WOBBLE FRICTION COEFFICIENT = 0.000X POST-TENSION END ANCHORAGE DETAIL OF GROUT TUBE OR VENT 3 8" > POST-TENSION DUCT & DECK PDP-14_POST-TENSION DETAILS 2. dgn 4 SECTION CC: POST-TENSION DUCT SPLICE 8 3 4" > POST-TENSION DUCT & SPLICE POST-TENSION END ANCHOR BLOCKOUT SEE NOTE 1 LOCAL ANCHORAGE ZONE REINFORCEMENT, CAGE TYPE SECTION EE: LOCAL ANCHORAGE ZONE REINFORCEMENT OPTION 2 UDOT DESI GN M ANAGER DATE APPROVED FOR USE STRUCTURES DI VI SI ON COUNTY 7/19/2010 PDP - 14 DRG. NO. SHT. BY UDOT DATE PROJECT NUM BER > TRANSVERSE JOINT TYPI CAL POSTTENSI ONI NG DETAI LS 2 1" FOAM BACKER ROD RECOM M . DATE SECTION DD: LOCAL ANCHORAGE ZONE REINFORCEMENT OPTION 1 4" 7" PANEL SEE NOTE 1 CONCRETE DECK PANEL 3 8 LOCAL ANCHORAGE ZONE REINFORCEMENT, SPIRAL TYPE DECK 4" 6"+ TYPI CAL DETAI L SHEET > TRANSVERSE DECK PANEL JOINT POST-TENSION END ANCHOR BLOCKOUT APPROVAL NO. 8 4 3 8" 3 > POST-TENSION DUCT & DECK UTAH DEPARTM ENT GROUT TUBE OR VENT 4" > TRANSVERSE JOINT FULL DEPTH PRECAST CONCRETE DECK PANELS SKEWED DETAIL AT DUCT CONNECTION CONCRETE DECK PANEL DETAIL AT DUCT CONNECTION 1" FOAM BACKER ROD OF TRANSPORTATI ON 1" FOAM BACKER ROD PI N > POST-TENSION DUCT & SPLICE 4" DUCT SPLICE BY > POST-TENSION DUCT & SPLICE 6"¨ 4" DUCT SPLICE (TYP.) CC FILL WITH NON-SHRINK GROUT QUANT. DRAW N SEAL DUCT AT SPLICE (TYP.) CC SEAL DUCT AT SPLICE (TYP.) CHECK CHECK CHECK REVI SI ON REM ARKS (TYP.) SENI OR DESI GN ENGI NEER 6"¨ SEAL DUCT AT SPLICE (TYP.) 1. ANCHORAGE ASSEMBLY AND DUCTS MAY BE LOWERED UP TO " FROM MID-DEPTH OF SLAB IN ORDER TO PROVIDE 2" TOP COVER FOR REINFORCING ABOVE THE DUCT. DESI GN FILL WITH NON-SHRINK GROUT (TYP.) 3"¨ 6"+ POST-TENSIONING NOTES: > TRANSVERSE JOINT > TRANSVERSE JOINT OF 1’-5" 1’-5" 2" 9" 8" 9" 8" " SECTION Y - SMOOTH REAR FACE BEND BOTTOM BAR TO MAINTAIN 1" CL. OVER DRIP GROOVE DECK PANEL REINF. #6 @ 12" TOP & BOT. SECTION Y - FRACTURED FIN REAR FACE NOTE: PRECAST PANEL SHOWN, PRESTRESSED PANEL SIMILAR PARAPET JOINT DETAIL NOTE: PRECAST PANEL SHOWN, PRESTRESSED PANEL SIMILAR > DECK JOINT > DECK JOINT 8’-0" MIN. - 16’-0" MAX. - SEE NOTE 1 BELOW (TYP.) FRACTURED FIN Y FRACTURED FIN EDGE OF PRECAST PARAPET SECTION SMOOTH SECTION SMOOTH 1 1 6" (TYP.) 2" " (TYP.) (TYP.) 4" 3 PDP-15_PARAPET DETAILS 1. dgn (TYP.) " (TYP.) Y > TRANSVERSE JOINT FRACTURED FIN DETAIL NOTES 1. EXTEND SEALANT AND FOAM BACKER ROD FROM DECK TOP TO TOP OF PARAPET ON THE INSIDE PARAPET FACE, AND ACROSS TOP OF PARAPET. 2. ADJUST BAR SPACING AS REQUIRED TO NOT EXCEED MAXIMUM SPACING SHOWN. 7/19/2010 TYPI CAL DETAI L SHEET 6" 3. FRACTURED FIN PARAPETS AND CONSTANT SLOPE ARE SHOWN, OTHERS MAY BE USED. PRECAST DECK PANEL CHECK DRAW N DATE DATE APPROVED FOR USE BY UDOT RECOM M . STRUCTURES DI VI SI ON DECK PANEL REINF. #6 @ 12" TOP & BOT. " DIA. BACKER ROD 1 2" 7 PI N BEND BOTTOM BAR TO MAINTAIN 1" CL. OVER DRIP GROOVE ROTATE HOOK AS NEEDED TO ACHIVE CLEARANCES PROJECT NUM BER 2" 1 1 7 1" CL. " DECK PANEL REINF. #6 @ 6" T & B PARAPET DETAI LS 1 8" 1" CL. 1" CL. 1" CL. ROTATE HOOK AS NEEDED TO ACHIVE CLEARANCES UDOT DESI GN M ANAGER BY DATE 1 7 2" CL. DECK PANEL REINF. #6 @ 6" T & B UTAH DEPARTM ENT OF SEE DETAIL C 8" FULL DEPTH PRECAST CONCRETE DECK PANELS 1 7 SEALANT APPROVAL NO. PRECAST DECK PANEL TRANSPORTATI ON OVERLAY 1" 2" CL. SENI OR DESI GN ENGI NEER 2 4" DIA SCH 40 STEEL (GALVANIZED) CONDUIT 4" 2" CLEAR COVER MEASURED AT BOTTOM OF FIN VALLEY PRECAST DECK PANEL DESI GN PLACE AS SHOWN 2" DIA SCH 40 PVC (PLACED AFTER DECKINSTALLATION) 10 10 4" OVERLAY DETAIL C - 4" DIA SCH 40 STEEL (GALVANIZED) CONDUIT 1 4" DIA SCH 40 STEEL (GALVANIZED) CONDUIT #5 #5 2" DIA SCH 40 PVC (PLACED AFTER DECKINSTALLATION) 1 BARS, 3’-0" 3’-6" 4" DIA SCH 40 STEEL (GALVANIZED) CONDUIT - 2" CLEAR COVER MEASURED AT BOTTOM OF FIN VALLEY #4 @ 6" FRACTURED FIN SEE DETAIL BARS, 3’-6" PLACE AS SHOWN #4 @ 6" 1" QUANT. " #5 @ 6" 6" #5 @ 6" FRACTURED FIN CHECK BARRIER REFLECTOR MAX. SPA. = 50’ REVI SI ON REM ARKS BARRIER REFLECTOR MAX. SPA. = 50’ CHECK 2" ELEVATION NOTES: 1. LENGTH BASED ON PRECAST DECK PANEL. LENGTH AS DETERMINED BY DESIGNER. COUNTY PDP - 15 DRG. NO. 4. VALID FOR TL-4. SHT. OF 1’-5" PARAPET 1 BY 1" #5 DOWEL 2" 1 4" 2’-10" LAP SPLICE OF LONG. PARAPET 1 2" 1 1 2" CL. 1 1 (TYP.) > TRANSVERSE JT REINFORCING (TYP.) FOAM BACKER ROD (TYP.) 2" FILL SHEAR KEY WITH NON-SHRINK GROUT 2" SEALANT (TYP.) 2" 1 4" 3 3 4" SKEWED SECTION X: PRECAST PARAPET THROUGH SHEAR KEY 1 3 4" 3 " 8 PDP-16_PARAPET DETAILS 2. dgn CONCRETE DECK PANEL 1" BY UDOT APPROVED FOR USE FOAM BACKER ROD EXTENDS FULL LENGTH OF DECK JOINT BETWEEN PANELS SECTION V: SHEAR KEY THROUGH DECK PANEL 7/19/2010 DATE DATE FRACTURED FIN (TYP.) P.) 1 NOTE: PARAPET AND SHEAR KEY REINFORCING NOT SHOWN FOR CLARITY. 4 2" SECTION W: SHEAR KEY THROUGH DECK PANEL AND PARAPET SHEAR KEY SECTION THROUGH PARAPET AND DECK PANEL #5 LOOP DOWEL (TYP.) PI N FOAM BACKER ROD EXTENDS FULL LENGTH OF DECK JOINT BETWEEN PANELS PROJECT NUM BER V FULL DEPTH PRECAST CONCRETE DECK PANELS 4" 1" (TY W FILL VOID WITH NON-SHRINK GROUT (TYP.) PARAPET REINFORCING SEE "PARAPET DETAILS 1" SHEET 1 4" 3 15^ MAX. SKEW 1 4" 2" CL. NO. UTAH DEPARTM ENT 1 4" 6 > TRANSVERSE JOINT 3 1 2" 2" CL. 1 2" 1 2" 2 (TYP.) 4 FILL DECK PANEL SHEAR KEY WITH NON-SHRINK GROUT 3 4" 1 2" 10 3 4" 8 " V SECTION X: PRECAST PARAPET THROUGH SHEAR KEY PLACE NON-SHRINK GROUT TO THIS ELEVATION AT THE SAME TIME AS PLACEMENT OF THE DECK PANEL JOINT NON-SHRINK GROUT 4" PARAPET 7 13 10" 16" PLACE NON-SHRINK GROUT TO THIS ELEVATION AT THE SAME TIME AS PLACEMENT OF THE DECK PANEL JOINT NON-SHRINK GROUT DATE 4" 1 1 > TRANSVERSE JT STRUCTURES DI VI SI ON 1 4 2" CL. (TYP.) 1" 8" 4" 5" CONCRETE DECK PANEL SHEAR KEY 4" FOAM BACKER ROD (TYP.) SEALANT (TYP.) FILL UPPER VOID WITH NON-SHRINK GROUT AFTER COMPLETION OF POST-TENSIONING CONCRETE DECK PANEL 3 12 CONCRETE DECK PANEL 3 2’-10" LAP SPLICE OF LONG. PARAPET REINFORCING (TYP.) TYPI CAL DETAI L SHEET " C T Y C P . ) X W 8 #5 DOWEL ( 2 1’-5 1 2" #5 DOWEL 1’-5 1 2" 9" X 2" 2" CL. FAR SIDE PARAPET ELEMENT QUANT. 1 1 FRACTURED FIN (TYP.) (TYP.) (T YP .) NEAR SIDE PARAPET ELEMENT (TYP.) #5 LOOP DOWEL (TYP.) SHEAR KEY 3’-6" PARAPET AND PARAPET SHEAR KEY FILL UPPER VOID WITH NON-SHRINK GROUT AFTER COMPLETION OF POST-TENSIONING DESI GN #5 LOOP DOWEL (TYP.) 4" 1 4 4" FILL VOID WITH NON-SHRINK GROUT (TYP.) UDOT DESI GN M ANAGER PARAPET REINFORCING SEE "PARAPET DETAILS 1" SHEET DRAW N 1" (TYP.) > HALF ROUND BLOCKOUT REVI SI ON REM ARKS > TRANSVERSE JOINT CHECK 16" CHECK 10 CHECK 16" SENI OR DESI GN ENGI NEER 9 RECOM M . 4 PARAPET DETAI LS 2 8" APPROVAL 3 OF TRANSPORTATI ON 2 COUNTY PDP - 16 DRG. NO. SHT. OF I CHECK CONTROL LINE I B DRAW N I H G G DESI GN 10’ QUANT. A D CHECK CHECK REVI SI ON REM ARKS CONTROL LINE A I E F C BY C UDOT DESI GN M ANAGER A A E SENI OR DESI GN ENGI NEER E E G A LENGTH MEASURED FROM CONTROL LINE + A BOTTOM WIDTH OF PARAPET + " B WIDTH (OVERALL) + " B HEIGHT OF PARAPET + " C HORIZONTAL DISTANCE OF PARAPET SLOPE + " D LOCATION OF BOTTOM EDGE OF PARAPET ¨ " E LOCATION OF TOP EDGE OF PARAPET + " C DEPTH (OVERALL) + D VARIATION FROM SPECIFIED PLAN END SQUARENESS OR SKEW + " E PDP-17_Deck Panel TOLERANCES. dgn " LOCATION OF LEVELING BOLTS " + 1" F SWEEP OVER MEMBER LENGTH: + " G LOCATION OF PROJECTING REINFORCING MEASURED FROM A COMMON REFERENCE POINT + " H LOCAL SMOOTHNESS OF ANY SURFACE I LOCATION OF BLOCKOUT FOR SHEAR CONNECTORS J LOCATION OF POST TENSIONING DUCT MEASURED FROM A COMMON REFERENCE POINT K LOCATION OF POST TENSIONING DUCT MEASURED FROM BOTTOM OF PANEL AT EDGE OF PANEL + L ERECTION ELEVATION TOLERANCE + " + " IN 10 FEET + " + " TYPI CAL DETAI L SHEET PRECAST PARAPET TOLERANCES DECK PANEL TOLERANCES 1 8" DATE COUNTY 7/19/2010 PDP - 17 DRG. NO. SHT. BY UDOT APPROVED FOR USE STRUCTURES DI VI SI ON ELEVATION PI N PRECAST PARAPET - TRANSVERSE SECTION K PROJECT NUM BER C H L DECK PANEL TOLERANCES 10’ L FULL DEPTH PRECAST CONCRETE DECK PANELS POST TENSIONING DUCT UTAH DEPARTM ENT OF NO. PLAN RECOM M . B APPROVAL D B TRANSPORTATI ON D DATE POST TENSIONING DUCT J G REINFORCING PROJECTING INTO CLOSURE POURS DATE J OF APPENDIX G DRAWINGS OF BULB-TEE GIRDERS FROM UTAH DOT Note: These are direct extract from <http://www.udot.utah.gov/main/uconowner.gf?n=14493404283799689> (Last accessed June 25, 2012) IT IS THE DESIGNER’S RESPONSIBILITY TO: GENERAL NOTES INDEX OF SHEETS USE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 4TH EDITION WITH ALL INTERIM PROVISIONS EXCEPT AS NOTED OTHERWISE, FOR ALL BULB TEE GIRDER DESIGNS GNBT-1 FILL IN TABLE FOR EACH GIRDER TYPE ON A PROJECT. BT-1 PRECAST BULB TEE GIRDER STANDARD GIRDER SIZES CREATE A FRAMING PLAN OF EACH SPAN. SEE PRECAST BULB TEE GIRDER MANUAL SECTION 4. USE AN HL-93 LOAD INCLUDING A 35 PSF LOAD FOR FUTURE OVERLAY FOR GIRDER DESIGNS. BT-2 PRECAST DECK BULB TEE GIRDER STANDARD GIRDER SIZES FOR USE WITH PRECAST PANELS - MAXIMUM BEAM/GIRDER SPACING = 10’-0" CREATE TYPICAL TRANSVERSE SECTIONS AS NEEDED. SEE PRECAST BULB TEE GIRDER MANUAL SECTION 4. PRESTRESSED GIRDER CONCRETE: f’c = 8,500 PSI BT-3 FOR USE WITH PRESTRESSED PANELS - MAXIMUM BEAM/GIRDER SPACING = 12’-0" CREATE SPECIAL GIRDER END DETAILS AS NEEDED. SUCH AS, VARYING GEOMETRIC END TREATMENTS, EXTENSIONS OF PRESTRESSING STRAND FOR GIRDER ENDS FOR CONTINUITY OF LIVE LOAD. REVI SI ONS THESE GUIDELINE DRAWINGS CAN BE USED ONLY FOR BRIDGES WHICH HAVE ALL OF THE FOLLOWING CHARACTERISTICS: IMPLEMENTATION BULB TEE GIRDER GENERAL NOTES SKEW ANGLE: 0 TO 45 DEGREES BY UDBT50-(1,2) PRECAST DECK BULB TEE GIRDER UDBT50 DETAILS UDBT58-(1,2) PRECAST DECK BULB TEE GIRDER UDBT58 DETAILS UDBT66-(1,2) PRECAST DECK BULB TEE GIRDER UDBT66 DETAILS FOR TOP SURFACE OF BULB TEE AND POST TENSIONED BULB TEE, USE A ROUGHENED SURFACE (1/4" AMPLITUDE). FOR DECK BULB TEE USE A HEAVY BROOM FINISH ON RIDING SURFACE OF TOP FLANGE. UDBT74-(1,2) PRECAST DECK BULB TEE GIRDER UDBT74 DETAILS UDBT82-(1,2) PRECAST DECK BULB TEE GIRDER UDBT82 DETAILS DECK BULB TEES HAVE A " CONCRETE GRINDING ALLOWANCE FOR CORRECTING UNEVEN ROADWAY SURFACES AT LONGITUDINAL JOINTS. LOSS OF " OF TOP FLANGE TO BE ACCOUNTED FOR IN DESIGN. UDBT90-(1,2) PRECAST DECK BULB TEE GIRDER UDBT90 DETAILS UDBT98-(1,2) PRECAST DECK BULB TEE GIRDER UDBT98 DETAILS APPLY CONCRETE POLYMER OVERLAY ON BRIDGE DECK AFTER CONCRETE GRINDING OR STEEL SHOT IS COMPLETE. SEE SECTION 03372 IN THE STANDARD SPECIFICATIONS FOR SURFACE PREPARATION REQUIREMENTS. COAT ALL MILD REINFORCEMENT PER UDOT SPECIFICATIONS UNLESS OTHERWISE NOTED. UBT66PT-(1-4) PRECAST POST-TENSIONED BULB TEE GIRDER DETAILS UBT74PT-(1-4) PRECAST POST-TENSIONED BULB TEE GIRDER DETAILS UBT82PT-(1-4) PRECAST POST-TENSIONED BULB TEE GIRDER DETAILS UBT90PT-(1-4) PRECAST POST-TENSIONED BULB TEE GIRDER DETAILS GNBT1 BULB TEE NOTES. dgn UBT98PT-(1-4) PRECAST POST-TENSIONED BULB TEE GIRDER DETAILS DATE NO. DESIGN AND DETAIL LIFTING SUPPORTS AND HANDLING CONSIDERATIONS IN ACCORDANCE WITH THE PCI DESIGN HANDBOOK, PRECAST AND PRESTRESSED CONCRETE, FIFTH EDITION WITH ALL INTERIMS AND ERRATA (NO CRACKING CRITERIA). COUNTY GNBT-1 DRG. NO. 7/ 19/ 2010 CHECK PRECAST BULB TEE GIRDER UBT98 DETAILS UDBT42-(1,2) PRECAST DECK BULB TEE GIRDER UDBT42 DETAILS QUANT. PRECAST BULB TEE GIRDER UBT90 DETAILS UBT98-(1,2) UDOT BRI DGE ENGR. PRECAST BULB TEE GIRDER UBT82 DETAILS UBT90-(1,2) DATE UBT82-(1,2) PROJECT NUM BER USE UTAH DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (THE LATEST EDITION AND SUPPLEMENTS THERETO WHICH ARE IN EFFECT AT THE DATE OF REQUEST FOR BIDS) ALONG WITH SPECIAL PROVISIONS SECTION 03339S - FULL DEPTH STANDARD PRECAST CONCRETE DECK PANELS FOR MATERIALS, CONSTRUCTION AND WORKMANSHIP. CHECK ENSURE APPLICABLE GENERAL NOTES ARE INCLUDED IN THE PLAN SET. CHECK PRECAST BULB TEE GIRDER UBT74 DETAILS DRAW N ACCOUNT FOR THE HAUNCH LOAD CALCULATIONS,BUT DO NOT CONSIDER IT IN THE COMPOSITE SECTIONS PROPERTIES. 0.6" DIAMETER AASHTO M 203 GRADE 270 DESI GN PRECAST BULB TEE GIRDER UBT66 DETAILS UBT74-(1,2) PRESTRESSED LOW RELAXATION STRAND: SENI OR DESI GN ENGR. DO NOT USE TRANSFORMED SECTION PROPERTIES FOR GIRDER DESIGN. UBT66-(1,2) DESIGN AND CHECK ALL CHARACTERISTICS RELATED TO REQUIRED CLOSURE POURS. DATE POINTS OF SPAN FOR SPAN LENGTHS 80’-0" TO 120’-0" PRECAST BULB TEE GIRDER UBT58 DETAILS REINFORCING STEEL (COATED) fy = 60,000 PSI (WELDED WIRE REINFORCEMENT IS NOT ALLOWED) RECOM M . 1 3 PRECAST BULB TEE GIRDER UBT50 DETAILS UBT58-(1,2) DESIGN AND CHECK THAT END REINFORCEMENT DETAILED SATISFIES ALL APPLICABLE CODE PROVISIONS. APPROVAL POINTS OF SPAN FOR SPAN LENGTHS 120’-0" TO 160’-0" POINTS OF SPAN FOR SPAN LENGTHS LESS THAN 80’-0". PRECAST BULB TEE GIRDER UBT42 DETAILS UBT50-(1,2) APPROVED UBT42-(1,2) f’c = MATCH GIRDER STRENGTH GENERAL NOTES POINTS OF SPAN FOR SPAN LENGTHS GREATER THAN 160’-0" PRECAST DECK BULB TEE GIRDER WELDED STUD OPTION SALT LAKE CI TY,UTAH CLOSURE POUR CONCRETE FOR POST TENSIONED GIRDERS: INTERMEDIATE DIAPHRAGMS: 1 5 PRECAST BULB TEE GIRDER DIAPHRAGM DETAILS BT-5 STRUCTURES DI VI SI ON DESIGN AND CHECK WEB SHEAR REINFORCEMENT ALONG GIRDER SPAN. BT-4 BULB TEE GI RDER MINIMUM OVERHANG = 1’-0" SPECIFY CONCRETE RELEASE STRENGTH FOR EACH GIRDER BASED ON DESIGN. UTAH DEPARTM ENT OF TRANSPORTATI ON MAXIMUM OVERHANG = 4’-0" CONCRETE STRENGTH UP TO 10,000 PSI MAY BE USED WITH PRIOR APPROVAL FROM THE DEPARTMENT. PRECAST POST-TENSIONED BULB TEE GIRDER STANDARD GIRDER SIZES TYPI CAL DETAI L SHEET SPECIAL CONSIDERATIONS WITH PRECAST/PRESTRESSED PANELS: FOR USE BY UDOT GUIDELINES REM ARKS PRECAST BULB TEE GIRDERS GENERAL NOTES SHT. OF 4’-1" REM ARKS 3" 5’-6" REVI SI ONS 1’-9 1 8" BY 3" Yb (in) St 3 (in ) UBT98 Sb 3 (in ) UBT42 42 759 729 184042 71761 21.67 20.33 8494 9052 UBT50 50 810 778 283124 71914 25.88 24.12 10940 11738 UBT58 58 861 827 407026 72067 30.07 27.93 13538 14571 UBT66 66 912 876 557326 72221 34.23 31.77 16281 17544 UBT74 74 963 925 735599 72374 38.38 35.62 19166 20652 UBT82 82 1014 974 943421 72527 42.51 39.49 22191 23893 UBT90 90 1065 1023 1182360 72680 46.64 43.36 25353 27265 UBT98 98 1116 1072 1454000 72833 50.74 47.26 28653 30769 QUANT. UDOT BRI DGE ENGR. CHECK DRAW N DESI GN SENI OR DESI GN ENGR. PROJECT NUM BER Yt (in) 8" STANDARD GI RDER SI ZES 3’-2 UBT90 DEPTH WEIGHT AREA Ix c.g. Iy c.g. 2 4 4 (in) (Lbs/Ft) (in ) (in ) (in ) 3" 3 8" PRECAST BULB TEE GI RDER 3’-2 TYPI CAL DETAI L SHEET GIRDER TYPE 1 2" 5 3 8" UBT82 UBT74 3" 1 8" 1 2" 4 1 8" 5 3’-2 DATE 8’-2" 1 8" 1’-4 3" RECOM M . 3" 7’-6" 3" 1 4 8" 5 3 8" 16" APPROVAL 3" 16" 1’-4 3" 1 4 1’-9 4 3" 2" 3" 2" 1 8" 1 5 3 8" 1 8" 1’-4 3" 1’-9 7 3" 6’-2" 1 8" 8" 7 8" 1’-9 1’-9 3’-2 BT1 TO BT3 STANDARD GI RDER SHAPES. dgn 6 1 6 7 16" 8" 7 16" 8" 1 1’-4 7/ 19/ 2010 3" 3" 1 1 6 6’-10" 6 3" 3" 3" 3" 3" 3" 3" 4’-1" 1 3" 3" 4’-1" 3" 3" 4’-1" SALT LAKE CI TY,UTAH 4’-1" CHECK UBT66 UBT58 CHECK NO. 8" DATE 3’-2 STRUCTURES DI VI SI ON UBT50 3 8" UTAH DEPARTM ENT OF TRANSPORTATI ON 3’-2 DATE 5 3 8" APPROVED FOR USE BY UDOT 8" 1 2" 3" 1 4 3" 1 2" 1 5 8" 7 16" 8" 1’-4 3" 3 3’-2 UBT42 1’-9 4 3" 3" 8" 7 16" 8" 1’-4 5 3 3’-2 1 6 1 8" 8" 4 1 8" 1 3" 3" 1 6 3" 3" 3" 4’-10" 3" 3" 3" 7 1’-9 16" 8" 3" 1 2" 3" 2" 6 1’-4 4 1 7 1’-9 16" 5 1 8" 3’-6" 1 6 8" 1 4’-2" 3" 1 1’-4 8" 3" 3" 3" 3" 4’-1" 3" 4’-1" 3" 4’-1" COUNTY BT - 1 DRG. NO. SHT. OF 5’-11 2" 3" 2" 8" REM ARKS 3" 3" BY 1 3 3’-2 8’-2" 2" UDBT98 Yb (in) St 3 (in ) Sb 3 (in ) UDBT42 42 1015 974 238350 212226 17.33 24.67 13754 9662 UDBT50 50 1066 1023 368258 212379 20.74 29.26 17756 12586 UDBT58 58 1117 1072 530226 212532 24.19 33.81 21919 15683 UDBT66 66 1168 1121 725908 212685 27.70 38.30 26206 18953 UDBT74 74 1219 1170 956946 212839 31.24 42.76 30632 22379 UDBT82 82 1270 1219 1224970 212992 34.82 47.18 35180 25964 UDBT90 90 1321 1268 1531590 213148 38.44 51.56 39844 29705 UDBT98 98 1372 1317 1878430 213298 42.08 55.92 44639 33591 CHECK QUANT. PROJECT NUM BER 3" 8" COUNTY BT - 2 DRG. NO. 7/ 19/ 2010 UDOT BRI DGE ENGR. CHECK DRAW N DESI GN 1 4 8" 3 3’-2 STANDARD GI RDER SI ZES Yt (in) 3" PRECAST DECK BULB TEE GI RDER DEPTH WEIGHT AREA Ix c.g. Iy c.g. 2 4 4 (in) (Lbs/Ft) (in ) (in ) (in ) 8" 5 1 8" UDBT90 UDBT82 GIRDER TYPE 3 3’-2 5 8" 1’-4 3" 1 8" 3" 4 1 3 3’-2 5 8" 1 8" 3" 2" 3" 8" 4 8" 3 3’-2 5 1 1’-4 1 3" 3" UDBT74 BT1 TO BT3 STANDARD GI RDER SHAPES. dgn 1 1’-4 1 2" 1 8" 8" 1 4 2" 1 1’-4 7’-6" 6’-2" 6’-10" 2" DATE 2" APPROVED FOR USE BY UDOT 2" 2" SENI OR DESI GN ENGR. 1’-7 2" DATE 1 8" RECOM M . 3" 1 6 APPROVAL 3" 2" 2" TYPI CAL DETAI L SHEET 1’-7 1’-7 3" 1 2" 8" 2" 1 1 8" 2" 1 6 6 1 1’-7 2" 6" 1 8" 6 3" 2" 5 8" SALT LAKE CI TY,UTAH 6" 5 8" 6" 5’-11 5 8" 6" 5’-11 5 8" STRUCTURES DI VI SI ON 5’-11 CHECK UDBT66 UDBT58 5’-11 8" UTAH DEPARTM ENT OF TRANSPORTATI ON UDBT50 UDBT42 8" NO. 3 3’-2 5 8" 1 8" 8" 3 3’-2 1 8" 5 5 1 8" 3 3’-2 5 1 8" DATE 3" 3" 4 3" 8" 4 1 3" 1 1’-4 2" 4’-10" 3" 1 1’-4 1 4 3" 4 1 3" 1 8" 1’-4 2" 1’-7 2" 2" 2" 2" 4’-2" 2" 3’-6" 1 2" 8" 3" 1 6 2" 1 8" 1’-4 1 1’-7 2" 5’-6" 1 2" 1’-7 1 1’-7 2" 3" 1 8" 6 2" 6" 1 6 8" 1 8" REVI SI ONS 6 2" 5 8" 6" 5’-11 5 8" 6" 5’-11 5 8" 6" 5’-11 5 8" SHT. OF REM ARKS REVI SI ONS BY DATE NO. 4’-3" Yb (in) St 3 (in ) Sb 3 (in ) UBT66-PT 66 1050 1008 605416 84741 34.07 31.93 17769 18961 UBT74-PT 74 1117 1073 803380 85099 38.19 35.81 21036 22435 UBT82-PT 82 1185 1138 1035640 85456 42.30 39.70 24485 26084 UBT90-PT 90 1253 1203 1304270 85814 46.39 43.61 28115 29908 UBT98-PT 98 1320 1268 1611370 86171 50.48 47.53 31924 33906 COUNTY BT - 3 7/ 19/ 2010 DRG. NO. SHT. CHECK QUANT. UDOT BRI DGE ENGR. DATE CHECK CHECK DRAW N DESI GN SENI OR DESI GN ENGR. DATE SALT LAKE CI TY,UTAH UBT 98-PT APPROVED FOR USE BY UDOT 8" RECOM M . 3" 3 3’-4 APPROVAL 2" 1 8" PROJECT NUM BER Yt (in) 8" 3" STANDARD GI RDER SI ZES 5 3 3’-4 UBT 90-PT UBT 82-PT DEPTH WEIGHT AREA Ix c.g. Iy c.g. 2 4 4 (in) (Lbs/Ft) (in ) (in ) (in ) 3" PRECAST POSTTENSI ONED BULB TEE GI RDER UBT 74-PT 8" 1’-4 4 1 2" 1 8" 4 3" 1 4 3 3’-4 1 8" TYPI CAL DETAI L SHEET 1’-4 16" STRUCTURES DI VI SI ON 8’-2" 1 8" 7 UTAH DEPARTM ENT OF TRANSPORTATI ON 3" 3" 3" 3" 3" 16" 16" 3" 1 5 8" 3" 8" 1 5 3 8" 3’-4 GIRDER TYPE 1’-9 7’-6" 3" 4 3" 3 8" 3’-4 3" 3" 3" 1’-4 2" 2" 2" 1 4 1 8" 5 1 1’-4 3" 7 1 5 8" 8" 1 8" 8" 8" 1’-9 7 1’-9 16" 16" 1 5’-6" 1 1’-4 8 1 8" 7 1’-9 7 1’-9 UBT 66-PT BT1 TO BT3 STANDARD GI RDER SHAPES. dgn 3" 3" 8 1 8" 8 6’-10" 1 8" 1 6’-2" 8 3" 3" 1 8 3" 3" 3" 3" 4’-3" 3" 3" 3" 4’-3" 3" 4’-3" 3" 4’-3" OF DIAPHRAGM CONNECTIONS TO BE LOCATED ON THE GIRDER WEB. DESIGNER SHALL VERIFY THREAD INSERT CAPACITIES SPECIFIED AND MODIFY THEM WHERE APPLICABLE. > OF INTERIOR GIRDER THE BENT P L SHOWN IN SECTION B IS NOT NECESSARY FOR 0^ SKEWS. 6" 1’-4" L5x5x (MIN.) (TYP.) SLOPED NOTES MC18x42.7 REM ARKS SEE PLATE WELDING DETAIL 1 > OF EXTERIOR GIRDER 1 2" L8X6X 6" REVI SI ONS 1. INCLUDE ALL STEEL FOR DIAPHRAGMS IN THE COST OF THE PRESTRESSED CONCRETE GIRDER. > CONNECTOR ANGLE 2. ALL STEEL TO BE ASTM A709 GRADE 50 AND GALVANIZED IN IN ACCORDANCE WITH ASTM A 123. THREADED INSERT FOR " DIA. BOLT WITH 2" DIA. WASHER SEE NOTE 5 (TYP.) 2" 4. STEEL TO STEEL CONNECTIONS TO BE MADE USING " DIA. GALVANIZED HIGH-STRENGTH BOLTS. NOTE: CHANNEL SHOWN, K-FRAME DIAPHRAGM SIMILAR. INTERMEDIATE DIAPHRAGM SIZING TABLE > CONNECTOR ANGLE 1’-7" L3x3x (MIN.) (TYP.) BENT PLATE (TYP.) FORM 1" DIA. HOLES - SEE NOTE 3 (TYP.) SECTION B-B: INTERMEDIATE DIAPHRAGMS GIRDER DEPTH DIAPHRAGM CHANNEL SIZE (SEE NOTE 11) 42 TYPE I MC18x42.7 50 TYPE I MC18x42.7 58 TYPE I MC18x42.7 66 TYPE II N/A 74 TYPE II N/A 82 TYPE II N/A 90 TYPE II N/A 98 TYPE II N/A THREADED INSERT FOR " DIA. BOLT WITH 2" DIA. WASHER SEE NOTE 5 (TYP.) " P (MIN.) L > OF EXTERIOR GIRDER > OF INTERIOR GIRDER INTERMEDIATE DIAPHRAGM LOCATION TABLE A L8X6X 15" LONG (TYP.) SPAN LENGTH SLOPED < 80 FT 80 FT TO 120 FT B B MC18x42.7 SEE NOTE 8 120 FT TO 160 FT H/2 A SPAN PTS. 1 5 SPAN PTS. NOTE TO DESIGNER: INSERT SHEET AS NEEDED INTO DESIGN DRAWINGS AND NUMBER AS FOLLOWS: UBTXX-X, UDBTXX-X, OR UBTXXPT-X COUNTY BT - 4 NOTE: STOP WELDS " SHORT OF ALL PLATE ELEMENTS DRG. NO. SHT. CHECK QUANT. CHECK FORM 1" DIA HOLES - SEE NOTE 3 (TYP.) PLATE WELDING DETAIL 7/ 19/ 2010 3 SPAN PTS. TYP. GIRDER SPACING INTERMEDIATE - TYPE I SPAN PTS. 1 (TYP.) BT4 DI APHRAGM DETAI LS. dgn > 160 FT DIAPHRAGM LOCATION ALONG GIRDER PRECAST BULB TEE GI RDER SKEWED INTERMEDIATE DIAPHRAGM - TYPE II TYPI CAL DETAI L SHEET GIRDER SPACING UDOT BRI DGE ENGR. L8X6X (MIN.) (TYP.) DATE BENT PLATE " MIN. THICKNESS WELDED TO DIAPHRAGM (TYP.) THREADED INSERT FOR " DIA. BOLT WITH 2" DIA. WASHER SEE NOTE 5 (TYP.) PROJECT NUM BER > CONNECTOR ANGLE DRAW N THREADED INSERT FOR " DIA. BOLT WITH 2" DIA. WASHER SEE NOTE 5 (TYP.) SLOPED DESI GN BENT PLATE (TYP.) SENI OR DESI GN ENGR. 10. SEE GIRDER DRAWINGS FOR GIRDER CONNECTION REQUIREMENTS DATE > OF INTERIOR GIRDER RECOM M . > BOLT SEE PLATE WELDING DETAIL 9. FOR SQUARE SUPERSTRUCTURES, FORM 1" DIA. HOLES IN INTERIOR GIRDERS FOR THRU-BOLTING OF DIAPHRAGM ANGLE. FOR FASCIA GIRDERS AND SKEWED STRUCTURES, THREADED INSERTS ARE REQUIRED. PLACE HOLES AND THREADED INSERTS PERPENDICULAR TO GIRDER WEB. APPROVAL DIAPHRAGM CHECK 8. " BENT PLATE OF EQUAL DIMENSIONS MAY BE SUBSTITUTED FOR MC18X42.7. > GIRDER DI APHRAGM DETAI LS INTERMEDIATE DIAPHRAGM - TYPE II NO. 7. FIELD DRILLED HOLES IN DIAPHRAGM CONNECTION ANGLES TO BE PERMITTED AT NO ADDITIONAL EXPENSE. ALL OTHER HOLES TO BE SHOP DRILLED. GIRDER SPACING 1’-4" DATE 6. WASHERS TO BE ASTM F436. ALL BOLTS, NUTS, AND WASHERS TO BE GALVANIZED IN ACCORDANCE WITH ASTM A 153. FORM 1" DIA. HOLES - SEE NOTE 3 (TYP.) > OF EXTERIOR GIRDER BY 5. STEEL TO CONCRETE CONNECTIONS TO BE MADE USING ASTM A307 GRADE A BOLTS. SALT LAKE CI TY,UTAH L8x6x 9" LONG (TYP.) SECTION A-A: INTERMEDIATE DIAPHRAGM STRUCTURES DI VI SI ON 1’-7" L3x3x (MIN.) (TYP.) UTAH DEPARTM ENT OF TRANSPORTATI ON > CONNECTOR ANGLE APPROVED FOR USE BY UDOT 3 1 1 1 2" 3. FABRICATE INTERMEDIATE AND END DIAPHRAGMS WITH VERTICAL ENDS. 1 2 2" OF B D NOTES 20" 1 2" 1 2" 1 2 7 1. DETAILS DRAWN FOR 1" DIA. SHEAR STUDS. 2" 2. CONTRACTOR TO DETERMINE METHOD FOR ACHIEVING WELDING GROUND FOR ATTACHMENT OF SHEAR STUDS. A WELDED GROUND LUG IS ACCEPTABLE PROVIDED THERE IS NO INTERFERENCE WITH PLACEMENT OF STUDS OR PLACEMENT OF PRECAST PANEL. C 3. FORM CAMBER STRIP AND FILL WITH NON-SHRINK GROUT. METHOD OF FORMING CAMBER STRIP TO BE DETERMINED BY THE CONTRACTOR. REMOVE FORMS AFTER NON-SHRINK GROUT OBTAINS A COMPRESSIVE STRENGTH OF 3000 PSI. 1 2" 3 #5 U-SHAPED SHEAR BAR EMBEDDED IN PRESTRESSED CONCRETE GIRDER 6" 4" 4" REVI SI ONS > PLATE 6" C > STUD 5" A A 12" 3 6" 1 2" 2 REM ARKS 1 2" 7 6" 4. FOR BLOCKOUT IN PRECAST PANELS SEE OPTIONS IN PRECAST PANEL DRAWINGS. > GIRDER D DATE TROWEL SMOOTH - APPLY BOND BREAKER (TYP.) 2" 5" #5 U-SHAPED SHEAR BAR EMBEDDED IN PRESTRESSED CONCRETE GIRDER SECTION C-C: OPTIONAL SHEAR STUDS 6" SHEAR STUD FIELD WELDED TO EMBEDDED PLATE AFTER PRECAST PANEL IS PLACED (TYP.) CAMBER STRIP SEE NOTE 3 5" BULB TEE GIRDER TOP FLANGE 4" 4" CAMBER STRIP SEE NOTE 3 EMBEDDED " PLATE WITH SHEAR STUDS PRECAST INTO GIRDER 1 3 2" 5" 1 2" 3 > STUD SECTION B-B: U-SHAPED SHEAR BAR SECTION D-D: OPTIONAL SHEAR STUDS NOTE: ONE ROW OF STUDS SHOWN ON TOP. MULTIPLE ROWS MAY BE USED. NOTE TO DESIGNER: INSERT SHEET AS NEEDED INTO DESIGN DRAWINGS AND NUMBER AS FOLLOWS: UBTXX-X, UDBTXX-X, OR UBTXXPT-X COUNTY BT - 5 7/ 19/ 2010 DRG. NO. SHT. OF QUANT. DRAW N DESI GN CHECK CHECK 6" PRECAST CONCRETE DECK PANEL TYPI CAL DETAI L SHEET SECTION A-A: U-SHAPED SHEAR BAR BULB TEE EMBEDDED " PLATE WITH SHEAR STUDS PRECAST INTO GIRDER 2" > GIRDER > GIRDER PRECAST CONCRETE DECK PANEL 5" UDOT BRI DGE ENGR. BULB TEE GIRDER DATE #5 U-SHAPED SHEAR BAR EMBEDDED IN PRESTRESSED CONCRETE GIRDER SENI OR DESI GN ENGR. TROWEL SMOOTH - APPLY BOND BREAKER (TYP.) BULB TEE GIRDER EXPANDED POLYSTYRENE MAY BE USED TO FORM CAMBER STRIP (TYP.) CAMBER STRIP SEE NOTE 3 DATE CAMBER STRIP SEE NOTE 3 RECOM M . 5" 12" (TYP.) EXPANDED POLYSTYRENE MAY BE USED TO FORM CAMBER STRIP (TYP.) APPROVAL SLOPE 12" (TYP.) GIRDER TOP FLANGE SHEAR STUD FIELD WELDED TO EMBEDDED PLATE AFTER PRECAST PANEL IS PLACED (TYP.) 3" GI RDER W ELDED STUD OPTI ON 4" SLOPE BT5 W ELDED STUD DETAI LS. dgn 4" SALT LAKE CI TY,UTAH 4" STRUCTURES DI VI SI ON 3" PRECAST DECKS ON BULB TEE PRECAST CONCRETE DECK PANEL SEE NOTE 4 4" PRECAST CONCRETE DECK PANEL SEE NOTE 4 UTAH DEPARTM ENT OF TRANSPORTATI ON NOTE: ONE ROW OF STUDS SHOWN ON TOP. MULTIPLE ROWS MAY BE USED. CHECK NO. OPTIONAL SHEAR STUD PLAN ON BULB TEE GIRDER APPROVED FOR USE BY UDOT U-SHAPED SHEAR BAR PLAN ON BULB TEE GIRDER EMBEDDED " PLATE WITH SHEAR STUDS PRECAST INTO GIRDER PROJECT NUM BER SHEAR STUD WELDED TO EMBEDDED PLATE (TYP.) B BY > GIRDER APPENDIX H DETAILS OF NEXT D BEAM FROM PCI-NE Note: These are direct extract from <http://www.pcine.org/index.cfm/resources/bridge> (Last accessed June 25, 2012) NEXT 40 D NEXT 36 D NEXT 32 D NEXT 28 D 96.00 96.00 96.00 96.00 40.00 36.00 32.00 28.00 13.00 13.25 13.50 13.75 MINIMUM WIDTH BEAMS 1666 238059 1562 176674 1455 126111 1346 85651 25.47 23.03 20.57 18.06 14.54 12.97 11.43 9.94 16378 13624 11033 8620 9348 7671 6131 4742 1735 1627 1516 1402 NEXT 40 D NEXT 36 D NEXT 32 D NEXT 28 D 120.00 120.00 120.00 120.00 40.00 36.00 32.00 28.00 13.00 13.25 13.50 13.75 MAXIMUM WIDTH BEAMS 1858 258171 26.55 1754 191453 24.01 1647 136502 21.44 1538 92597 18.80 13.45 11.99 10.57 9.20 19201 15973 12920 10069 9722 7973 6368 4924 1935 1827 1716 1602 APPENDIX I STANDARD LONGITUDINAL CONNECTION DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION BUREAU OF HIGHWAY DEVELOPMENT DRAWN BY: CHECKED BY: ISSUED: SUPERSEDES: STANDARDIZED LONGITUDINAL CONNECTION DETAILS APPROVED BY: High performance concrete 3" 4 1 2" Sacrificial surface 3" 4 1" SLAB 92 2" 43 4" 1" 14 3" 4 3" 4 6"+41" BRIDGE LENGTH 641" 1 4" 641" COMPONENT WIDTH 1 4" EA03 BAR ** 1'-0" MIN LAP EK04 BAR Top/slab EK04 BARS * EK04 BARS * * EK04 BARS 1" SLAB 92 3"MIN. 1" 12 6" EA03 1 4" (TYP) COMPONENT WIDTH 641" 1 4" NOTES: HIGH PERFORMANCE CONCRETE COMPRESSIVE STRENGTH IS NOT LESS THAN 7 KSI YIELD STRENGTH OF THE STEEL IS 60 KSI TEMPERATURE GRADIENT ZONE 3 AND HL-93 MOD LOADS WERE CONSIDERED. * EK04 BAR SPACING IS : 11" FOR DECKED BOX-BEAM. 7" FOR OTHER DECKED PRECAST PRESTRESSED CONCRETE GIRDERS. ** DIAMETER OF BEND (D) SHALL NOT BE LESS THAN 3 IN. PREPARED BY DESIGN DIVISION 6.41.xx APPENDIX J SPECIAL PROVISION FOR GROUTING PBES CONNECTIONS (Template) ............. DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUTING PBES CONNECTIONS 1. General. This work shall consist of furnishing material, equipment, and manpower for grouting prefabricated component connections (or referred as joints in this section) in accordance with the details shown on the plans and the requirements of these Specification. The work shall also include the furnishing and installing of any appurtenant items necessary for completing the grouting operations, including but not limited to, inlets, vents, outlets, and grout and any material used for mixing and curing and protecting grout during the required period. 2. Contractor Proposed Options: The contractor may propose for consideration certain changes to the connection details (including but not limited to, the shape, size, reinforcement details), material for filling the voids, application procedures, and curing and protection methods than what is shown in the plans and given in this Specification. 3. Restrictions to Contractor Proposed Options: Any changes proposed by the contractor shall comply with the following: a. Any changes proposed to the connection details to enhance the grout application procedures shall be demonstrated through mock-up testing or contractors own experience with a previous project. b. The ultimate strength of the structure with the proposed changes to the connection details shall meet the requirement of Section xx of the AASHTO XXXX, YY edition, 20XX, and all applicable interims and shall be equivalent or greater than the ultimate strength provided by the original design. c. The contractor fully redesigns and details of all the connections and associated components where the alternate details are proposed, as required. d. The contractor submits complete shop drawings indicating the locations of the connections and including revised connection and component details, design calculations, and a summary of the specific changes and justification for the changes for Engineer’s review. A draft prepared by Dr. Upul Attanayake, PE, at Western Michigan University Page 1 of 5 4. Working Drawings: The contractor shall submit detailed working drawings in accordance with Section XX of the …….. Standard Specification for Construction that include, but are not limited to: 1. Connection detail with multiple views (a minimum of two cross-sections with respect to two perpendicular axes and a plan view) 2. Name (if manufactured grout) or the mix design for each connection in a format similar to Table E–1. 3. Equipment for mixing and placement 4. Formwork, if needed (process of forming and removal; potential challenges such as grout leakage and remedial measures) 5. Surface preparation procedures 6. Grouting procedure and sequence 7. Grout curing, if applicable, and/or protection methods 8. Mock-up testing plan (void if contractor demonstrates prior experience with the specific detail, material, and equipment) 9. QA/QC plan based on the requirements listed in Table E–2 No 1 2 3 4 5 6 Table E–1. Connection and the grout/special mix Connection Grout/special mix Pier column to pier cap ABC grout extended Transverse connection between deck panels ABC grout Longitudinal closure Mix 1 Mix 1: (example) Cement Supplementary cementitious material Aggregate Water Admixtures A draft prepared by Dr. Upul Attanayake, PE, at Western Michigan University Page 2 of 5 5. Material: The materials to be incorporated into work covered by this section shall conform to the requirements set out herein. a. Grout/Special mixes Contractor shall identify a non-shrink grout/concrete mixes based on size, shape, and detailing of the connection, and exposure conditions during mixing, placing, and in-service. Contractor shall submit laboratory test results obtained from an independent testing lab on the following properties as per the specifications listed; Table E–2. Grout properties, requirements and test methods Property Requirement Test Method 1 day 3 days Strength 7 days 28 days Slump/flow Setting time Early age height change ASTM C827/C1107 Height change of hardened grout ASTM C1090/C1107 Shrinkage Air content Freeze/thaw durability Modulus of elasticity Thermal expansion coefficient b. Curing The contractor shall furnish required grout curing material as per the manufacturer requirement or the Section XX of the ……………Standard Specification for Construction. c. Grout protection The contractor shall furnish required grout protection material as per the manufacturer requirement or the Section XX of the …………..Standard Specification for Construction. A draft prepared by Dr. Upul Attanayake, PE, at Western Michigan University Page 3 of 5 6. Grouting plan and qualifications: At least XX weeks before grouting commences, the contractor shall submit to the Engineer for review and approval a "Grouting Operation Plan for Precast Component Connections". Written approval of the plan is required before grouting occurs. • Names of grouting crew and supervisor • Experience of crewmembers and supervisor • Training to be provided or undertaken prior to operations • Type of equipment to be used, including capacity in relation to demand • Working condition of equipment, back-up and spare parts • Types, brands, and certifications of materials • Identity of independent testing laboratory for certification of materials • General grouting procedure • Production of grout, on-site testing, adjustments and controls • Estimate of grout required amount of each type of grout/special mixes • Method of controlling consistency of grout • Grout mixing and placement procedures • Procedure for controlling w/c ratio, and for ensuring that the water used is acceptable • Contractor's QC forms that are to be signed daily by grout supervisor The contractor shall, throughout the duration of the grouting, coordinate his work and cooperate with the engineer. The contractor shall also provide at least one person who shall be present at the all times during formwork installation and grouting who is familiar with the operations involved and will direct the work. 7. Contribution to knowledge base (Report): The engineer will determine the locations to sample grout and the number and type of samples collected for field and laboratory testing based on the test methods and applicable standards listed in Table E–2. Report should include at least the followings: (the following includes extracts from ASTM C1107 and presented in italics) • Source, type and name of grout tested. • Details of any variations and options practiced by the tester that are recommended or allowed by the manufacturer or others. Also, designate by whom exceptions are allowed or recommended. • Number and size of each kind of grout specimen and the date molded. A draft prepared by Dr. Upul Attanayake, PE, at Western Michigan University Page 4 of 5 • Consistency at the time the specimens were molded and the water to dry solids ratio. • Mixing temperature and curing temperature. • Identity of specimens as being from (a) freshly mixed grout or (b) grout from end of maximum allowed usable working time. State the mixing age of grout when the specimens were prepared. • Height change from placement to time of final setting, %. • Height change of hardened, moist-cured grout at specimen age of 1, 3, 14, and 28 days, %. • Height change of hardened grout at 56 days of age when exposed to air drying for 28 days after 28 days of moist-curing, %. • Compressive strength of cubes at 1, 3, 7, and 28 days. • Yield of the grout. • Equipment used for grouting or method of grouting. • Challenges and lessons learned. • Recommendations for enhancing performance and construction practices of similar details. A draft prepared by Dr. Upul Attanayake, PE, at Western Michigan University Page 5 of 5