Facility Summary in YELLOWSTONE County in the City of BALLANTINE

by user

on
Category: Documents
69

views

Report

Comments

Transcript

Facility Summary in YELLOWSTONE County in the City of BALLANTINE
Facility Summary in YELLOWSTONE County in the City of BALLANTINE
Location:
Contact:
TIGER TOWN
2253 S 16TH RD
BALLANTINE, MT 59006
YELLOWSTONE
Carol & James Hayes, (406) 967-2895
Owners/Operators: Carol Hayes, Owner
Sys Fac ID: 56-06325
Last Inspected On: 4/4/2014
Operating Permit Renewal Date: 7/10/2017
(406)-967-2753
DBA TIGER TOWN
PO BOX 26
BALLANTINE MT 59006-0026
Carol Hayes, UST Class A Operator
Patti Anderson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
9
23
11/1/1992
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Not Required
Automatic Tank Gauging 0.2
TS-1001 , Incon
none
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Not Required
Automatic Tank Gauging 0.2
TS-1001 , Incon
none
Safe Suction
Deferred
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Not Required
Automatic Tank Gauging 0.2
TS-1001 , Incon
none
Safe Suction
Deferred
3310
Currently in Use
Diesel
3,000
10
4/1/2014
23
3311
Currently in Use
Gasoline
4,000
11
11/1/1992
4/1/2014
23
3312
Currently in Use
Gasoline
5,000
Report Generation Date: 8/31/2016
11/1/1992
4/1/2014
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 1
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 51
1544 BROADWATER AVE
BILLINGS, MT 59102
YELLOWSTONE
(406) 651-0001
Owners/Operators: CHS Inc - Spokane Valley, Owner
Sys Fac ID: 56-00050
Last Inspected On: 2/23/2015
Operating Permit Renewal Date: 7/14/2018
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Ian Johnstone, UST Class A Operator
Nicholas Merritt, UST Class B Operator
Darcy Ziegler, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
3074
Currently in Use
Gasoline
18
10/30/1997
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
2/23/2015
10,000
5
3075
Currently in Use
Gasoline
18
10/30/1997
2/23/2015
10,000
6
3076
Currently in Use
Gasoline
18
15,000
Report Generation Date: 8/31/2016
10/30/1997
2/23/2015
Page 2
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
5 CORNERS EXPRESS
5550 US HIGHWAY 312
BILLINGS, MT 59105
YELLOWSTONE
Mykel Stockton, (406) 245-6376
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-00062
Last Inspected On: 8/23/2013
Operating Permit Renewal Date: 12/28/2016
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Joey McConnell, UST Class B Global Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
5653
Currently in Use
Gasoline
00
6/30/2016
6/30/2016
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Not Listed
Positive Shutoff
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Not Listed
Positive Shutoff
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Not Listed
Positive Shutoff
Yes
Not Applicable
8,000
5
5654
Currently in Use
Gasoline
6/29/2016
00
4,000
6
5655
Currently in Use
Diesel
6/30/2016
6/30/2016
6/29/2016
00
8,000
Report Generation Date: 8/31/2016
6/30/2016
6/30/2016
6/29/2016
Yes
Yes
Yes
Page 3
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
5 CORNERS EXPRESS
5550 US HIGHWAY 312
BILLINGS, MT 59105
YELLOWSTONE
Mykel Stockton, (406) 245-6376
Sys Fac ID: 56-00062
Last Inspected On: 8/23/2013
Operating Permit Renewal Date: 12/28/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
7
5656
Currently in Use
Diesel
00
6/30/2016
6/30/2016
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Not Listed
Positive Shutoff
Yes
Not Applicable
4,000
Report Generation Date: 8/31/2016
6/29/2016
Yes
Page 4
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 GS CONVENIENCE CENTER 3
730 LAKE ELMO DR
BILLINGS, MT 59105
YELLOWSTONE
(406) 255-0688
Owners/Operators: SNG Inc 3, Owner
Sys Fac ID: 56-00063
Last Inspected On: 10/3/2014
Operating Permit Renewal Date: 1/8/2018
(406)-245-0161
4410 STATE AVE
BILLINGS MT 59101-5060
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
31
12/20/1984
Cathodically Protected Steel
Flexible Plastic
9/30/2014
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Continuous Interstitial Monitor, MLLD Line
Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
9/29/2014
TLS-350/Gilbarco EMC , Veeder Root
12/20/1984
Cathodically Protected Steel
Flexible Plastic
1872
Currently in Use
Gasoline
9/30/2014
Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Continuous Interstitial Monitor, MLLD Line
Tightness Testing
10,000
9/29/2014
TLS-350/Gilbarco EMC , Veeder Root
12/20/1984
Cathodically Protected Steel
Flexible Plastic
1873
Currently in Use
Gasoline
9/30/2014
Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Continuous Interstitial Monitor, MLLD Line
Tightness Testing
10,000
9/29/2014
TLS-350/Gilbarco EMC , Veeder Root
1871
Currently in Use
Diesel
10,000
2
3
31
31
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Page 5
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
RIMROCK SUBARU INC
324 S 24TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Scott Hazlet, (406) 655-8572
Owners/Operators: Rimrock Subaru Inc, Owner
Sys Fac ID: 56-00066
Last Inspected On: 4/29/2016
Operating Permit Renewal Date: 6/7/2019
(406)-651-5200
Jack McCoy, Operator
(406)-651-5000
PO BOX 80208
BILLINGS MT 59108
RIMROCK AUTO
324 S 24TH ST W
BILLINGS MT 59102-5644
Scott Haslet, UST Class A Operator
Scott Haslet, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
24
10/1/1991
Cathodically Protected Steel
Fiberglass Reinforced Plastic
5/4/2016
4/7/2010
None
Not Required
Automatic Tank Gauging 0.2
OPW 1500 , OPW
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.2
OPW 1500 , OPW
Fiberglass Reinforced Plastic
None
Gravity Feed
MLLD Line Tightness Testing
1863
Temporarily Out of Use
Gasoline
1,000
5
1864
Currently in Use
Waste Oil
1,000
24
Report Generation Date: 8/31/2016
10/1/1991
5/4/2016
5/4/2016
Ball Float Valve
Yes
Galvanic
Page 6
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ARCHIE COCHRANE MOTORS
2133 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Garry Brayko, (406) 656-1100
Owners/Operators: Archie Cochrane Motors, Owner
Sys Fac ID: 56-00123
Last Inspected On: 10/24/2014
Operating Permit Renewal Date: 3/26/2018
(406)-656-1100
PO BOX 80605
BILLINGS MT 59108-0605
LAUREN GOPP, UST Class A Operator
Don Hofer, UST Class A Operator
Don Hofer, UST Class B Operator
LAUREN GOPP, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
23
8/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
10/24/2014
Double-Walled
Not Required
Manual Interstitial Monitor
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
8/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
10/3/2011
Double-Walled
Not Required
Manual Interstitial Monitor
None
Safe Suction
Deferred
390
Currently in Use
Gasoline
2,000
5
23
391
Currently in Use
Diesel
1,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 7
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONOMART SUPERSTORE 4
1240 S 27TH ST
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-00503
Last Inspected On: 6/14/2016
Operating Permit Renewal Date: 9/28/2019
Owners/Operators: C Store Properties LLC, Owner
(406)-651-5101
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Laura Geffre, UST Class B Operator
Kim Hauck, UST Class B Operator
Roger Schmechel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
1148
Currently in Use
Gasoline
18
5/1/1998
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
5/28/2013
10,000
5
1149
Currently in Use
Gasoline
8/23/2010
18
10,000
Report Generation Date: 8/31/2016
5/1/1998
5/28/2013
8/22/2010
Page 8
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONOMART SUPERSTORE 4
1240 S 27TH ST
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-00503
Last Inspected On: 6/14/2016
Operating Permit Renewal Date: 9/28/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
1150
Currently in Use
Diesel
18
5/1/1998
4/1/2015
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
8,000
Report Generation Date: 8/31/2016
5/28/2013
5/3/2015
Page 9
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 1
1028 US HIGHWAY 87 E
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: Billings Holdings LLC, Owner
Sys Fac ID: 56-00767
Last Inspected On: 2/3/2015
Operating Permit Renewal Date: 2/6/2018
(406)-497-6700
PO BOX 6000
BUTTE MT 59702-6000
Charles A Armstrong, UST Class A Operator
Charles A Armstrong, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
4583
Currently in Use
Gasoline
19
10/2/1996
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
19
10/2/1996
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
19
10/2/1996
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
19
10/2/1996
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
12,000
7
2665
Currently in Use
Gasoline
12,000
8
2666
Currently in Use
Diesel
12,000
9
2667
Currently in Use
Diesel
12,000
Report Generation Date: 8/31/2016
Page 10
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 1
1028 US HIGHWAY 87 E
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-00767
Last Inspected On: 2/3/2015
Operating Permit Renewal Date: 2/6/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
10
17
2/1/1999
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
3921
Currently in Use
Diesel
6,000
Report Generation Date: 8/31/2016
1/1/2009
Page 11
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MSU FACILITY SERVICES BLDG
1500 UNIVERSITY DR
BILLINGS, MT 59101
YELLOWSTONE
Ken Billman, (406) 657-2309
Owners/Operators: Montana State University Billings, Owner
Sys Fac ID: 56-00904
Last Inspected On: 4/27/2015
Operating Permit Renewal Date: 8/21/2018
(406)-657-2309
1500 UNIVERSITY DR
BILLINGS MT 59101-0252
Brian Mackey, UST Class A Operator
Jason McGimpsey, UST Class A Operator
John Grimstad, UST Class B Operator
Brian Mackey, UST Class B Operator
Brian Mackey, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
19
9/1/1996
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Not Required
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
TLS-300 , Veeder Root
Double-Walled
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
846
Currently in Use
Gasoline
1,000
Report Generation Date: 8/31/2016
Continuous Interstitial Monitor
Page 12
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS LOGAN INTERNATIONAL AIRPORT UST
1901 TERMINAL CIR STE 216
BILLINGS, MT 59105
YELLOWSTONE
Donald (Kim) Annin, (406) 657-8482
Owners/Operators: Billings Logan International Airport, Owner
Sys Fac ID: 56-00909
Last Inspected On: 6/9/2016
Operating Permit Renewal Date: 9/4/2019
(406)-657-8482
1901 TERMINAL CIR STE 216
BILLINGS MT 59105-1991
Donald Annin, UST Class A Operator
Shawn Gaalswyk, UST Class A Operator
Shawn Gaalswyk, UST Class B Operator
Colter Smith, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
623
Currently in Use
Diesel
29
1/1/1987
Cathodically Protected Steel
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
10/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/9/2016
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
10/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/9/2016
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
6/6/2016
4,000
3
22
624
Currently in Use
Gasoline
10,000
4
22
625
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 13
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS LOGAN INTERNATIONAL AIRPORT UST
1901 TERMINAL CIR STE 216
BILLINGS, MT 59105
YELLOWSTONE
Donald (Kim) Annin, (406) 657-8482
Sys Fac ID: 56-00909
Last Inspected On: 6/9/2016
Operating Permit Renewal Date: 9/4/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
17
4826
Currently in Use
Waste Oil
500
22
10/1/1993
Cathodically Protected Steel
Double-Walled
Not Required
Manual Interstitial Monitor
Fiberglass Reinforced Plastic
Secondary Containment Chase
Gravity Feed
MLLD Line Tightness Testing
Ball Float Valve
Yes
Galvanic
Report Generation Date: 8/31/2016
6/9/2016
6/9/2016
Page 14
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
NORTHWESTERN ENERGY FACILITY
405 S 20TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Darren Brockel, (406) 655-2521
Owners/Operators: Northwestern Energy, Owner
Sys Fac ID: 56-01188
Last Inspected On: 8/29/2014
Operating Permit Renewal Date: 12/9/2017
(406)-655-2521
405 S 20TH ST W
BILLINGS MT 59102
John Habeger, UST Class A Operator
Darren Brockel, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
36
4/30/1980
Cathodically Protected Steel
Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
EECO 1500 , EMCO Electronics
None
Pressurized
Automatic Tank Gauging 0.2
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Impressed Current
Cathodically Protected Steel
Steel
None
Not Required
Automatic Tank Gauging 0.2
EECO 1500 , EMCO Electronics
None
Safe Suction
Deferred
Cathodically Protected Steel
Steel
None
Not Required
Automatic Tank Gauging 0.2
EECO 1500 , EMCO Electronics
None
Safe Suction
Deferred
1683
Currently in Use
Diesel
4,000
4
4/4/2014
36
1684
Currently in Use
Diesel
2,000
5
4/30/1980
4/4/2014
36
1685
Currently in Use
Gasoline
4,000
Report Generation Date: 8/31/2016
4/30/1980
4/4/2014
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Impressed Current
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Impressed Current
Page 15
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CARDLOCK #3
1004 4TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Roger Schmechel, (406) 252-4661
Owners/Operators: W G Properties LLC, Owner
Sys Fac ID: 56-01290
Last Inspected On: 6/23/2016
Operating Permit Renewal Date: 8/16/2019
(406)-651-5101
City Service Valcon LLC DBA GM Petroleum Distributors,
Operator
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Cody P Oconnor, UST Class A Operator
Roger Schmechel, UST Class A Operator
Laura Geffre, UST Class B Operator
Cody P Oconnor, UST Class B Operator
Roger Schmechel, UST Class B Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108-0391
PO BOX 30335
BILLINGS MT 59101
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
40
2/4/1976
Fiberglass Reinforced Plastic
Flexible Plastic
6/23/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
752
Currently in Use
Diesel
7/8/2013
20,000
2
TLS-350/Gilbarco EMC , Veeder Root
40
753
Currently in Use
Diesel
20,000
Report Generation Date: 8/31/2016
1/1/1976
Fiberglass Reinforced Plastic
Flexible Plastic
7/8/2013
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Page 16
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CARDLOCK #3
1004 4TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Roger Schmechel, (406) 252-4661
Sys Fac ID: 56-01290
Last Inspected On: 6/23/2016
Operating Permit Renewal Date: 8/16/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
40
2/4/1976
Fiberglass Reinforced Plastic
Flexible Plastic
6/23/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
754
Currently in Use
Diesel
7/8/2013
20,000
4
TLS-350/Gilbarco EMC , Veeder Root
40
755
Currently in Use
Diesel
2/4/1976
Fiberglass Reinforced Plastic
Flexible Plastic
6/23/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
7/8/2013
20,000
5
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
40
756
Currently in Use
Gasoline
20,000
Report Generation Date: 8/31/2016
2/4/1976
Fiberglass Reinforced Plastic
Flexible Plastic
7/8/2013
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
TLS-350/Gilbarco EMC , Veeder Root
Page 17
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
REDDAWAY
833 MULLOWNEY LN
BILLINGS, MT 59101
YELLOWSTONE
Fort Gary, (406) 252-3877
Owners/Operators: Reddaway, Owner
Sys Fac ID: 56-01340
Last Inspected On: 3/20/2013
Operating Permit Renewal Date: 5/30/2019
(913)-344-3367
10990 ROE AVE MS A-650
OVERLAND PARK KS 66211
Gary Fort, UST Class A Operator
Gary Fort, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
23
8/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
8/1/2003
4/7/2016
None
Not Required
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
3154
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Page 18
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 56
16 SHILOH RD
BILLINGS, MT 59106
YELLOWSTONE
Sean Hurley, (509) 535-7701
Owners/Operators: CHS Inc - Spokane Valley, Owner
Sys Fac ID: 56-01664
Last Inspected On: 2/17/2015
Operating Permit Renewal Date: 7/9/2018
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Ian Johnstone, UST Class A Operator
Darcy Ziegler, UST Class B Operator
Karina Serrano, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4344
Currently in Use
Diesel
31
12/31/1984
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
2/17/2015
12,000
2
4345
Currently in Use
Gasoline
31
12/31/1984
2/17/2015
12,000
3
4346
Currently in Use
Gasoline
26
10,000
Report Generation Date: 8/31/2016
11/10/1989
2/17/2015
Page 19
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 57
1046 N 27TH ST
BILLINGS, MT 59101
(406) 252-9654
Sys Fac ID: 56-01665
Last Inspected On: 2/9/2015
Operating Permit Renewal Date: 7/11/2018
YELLOWSTONE
Owners/Operators: CHS Inc - Spokane Valley, Owner
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Ian Johnstone, UST Class A Operator
Chuck Crane, UST Class B Operator
ROBERT HAYS, UST Class B Operator
Ian Johnstone, UST Class B Global Operator
Katherine Warmus, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
3080
Currently in Use
Gasoline
18
1/28/1998
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
High Level Alarm
Yes
Not Applicable
1/8/2009
1/8/2009
15,000
4
3081
Currently in Use
Gasoline
Gilbarco EMC Basic , Gilbarco
18
12,000
Report Generation Date: 8/31/2016
1/28/1998
1/8/2009
1/8/2009
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Page 20
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MT STATE WOMENS PRISON
701 S 27TH ST
BILLINGS, MT 59101
YELLOWSTONE
Dennis Wolfe, (406) 247-5133
Owners/Operators: Montana State Womens Prison, Owner
Sys Fac ID: 56-01757
Last Inspected On: 3/10/2015
Operating Permit Renewal Date: 4/4/2018
(406)-247-5100
701 S 27TH ST
BILLINGS MT 59101-4511
Ron Himmelspach, UST Class A Operator
Dennis Wolff, UST Class A Operator
Ron Himmelspach, UST Class B Operator
Dennis Wolff, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
10
10/1/2005
Cathodically Protected Steel
Flexible Plastic
2/10/2015
Double-Walled
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-300 , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
5053
Currently in Use
Diesel
2,000
Report Generation Date: 8/31/2016
2/10/2015
Page 21
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DEACONESS BILLINGS CLINIC 9TH AVE
2800 10TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Mitch Goplen, (406) 657-4030
Owners/Operators: Deaconess Clinic Billings, Owner
Sys Fac ID: 56-02067
Last Inspected On: 6/1/2015
Operating Permit Renewal Date: 9/29/2018
(406)-657-4036
2800 10TH AVE N
BILLINGS MT 59101-0703
Cody Anderson, UST Class A Operator
Lloyd Newman, UST Class A Operator
Cody Anderson, UST Class B Operator
Lloyd Newman, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
24
2/1/1992
Cathodically Protected Steel
Flexible Plastic
9/17/2012
Double-Walled
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
826
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
2/27/2015
Page 22
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SAINT VINCENT HOSPITAL & HEALTH CENTER
1233 N 30TH ST
BILLINGS, MT 59101
YELLOWSTONE
Kevin Maddox, (406) 657-7000
Owners/Operators: Saint Vincent Hospital & Health Center, Owner
Sys Fac ID: 56-02666
Last Inspected On: 12/23/2015
Operating Permit Renewal Date: 1/22/2019
(406)-237-3065
PO BOX 35200
BILLINGS MT 59107-5200
Kevin Maddox, UST Class A Operator
Kevin Maddox, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
1953
Currently in Use
Diesel
4,000
16
Yes
11/8/1999
11/9/2012
Bare Steel
None
Auto Dialer
Deferred
Auto Stik II , EBW
Copper
Secondary Containment Chase
Pressurized
MLLD Line Tightness Testing
Yes
Not Applicable
6
1954
Currently in Use
Diesel
4,000
16
Yes
Bare Steel
None
Auto Dialer
Deferred
Auto Stik II , EBW
Copper
Secondary Containment Chase
Pressurized
MLLD Line Tightness Testing
Yes
Not Applicable
1/13/2016
Report Generation Date: 8/31/2016
11/8/1999
11/9/2012
1/13/2016
Page 23
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SYSCO FOOD SERVICES OF MONTANA MONAD RD
1509 MONAD RD
BILLINGS, MT 59101
YELLOWSTONE
Greg Murray, (406) 247-1100
Owners/Operators: Sysco Food Services of Montana, Owner
Sys Fac ID: 56-03530
Last Inspected On: 4/24/2014
Operating Permit Renewal Date: 6/11/2017
(406)-247-1131
PO BOX 31198
BILLINGS MT 59107-1198
Greg Murray, UST Class A Operator
Greg Murray, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
4
5144
Currently in Use
Diesel
08
Yes
12/27/2007
Unknown
None
Electronic Line Leak Detector
Deferred
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor
10,000
5
5145
Currently in Use
Diesel
08
Yes
10,000
Report Generation Date: 8/31/2016
11/23/2013
TLS-350/Gilbarco EMC , Veeder Root
12/27/2007
Unknown
None
Electronic Line Leak Detector
Deferred
11/21/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
Yes
Not Applicable
Yes
Yes
Not Applicable
Yes
Page 24
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
YELLOWSTONE COUNTY PUBLIC WORKS DEPT
3321 KING AVE E
BILLINGS, MT 59101
YELLOWSTONE
John Ostlund, (406) 256-6812
Owners/Operators: Yellowstone County Public Works Dept, Owner
Sys Fac ID: 56-03658
Last Inspected On: 6/11/2015
Operating Permit Renewal Date: 9/29/2018
(406)-256-6812
3321 KING AVE E
BILLINGS MT 59101-5533
Kim Peterson, UST Class A Operator
Oscar Thompson, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
4092
Currently in Use
Waste Oil
17
6/1/1999
6/11/2015
Cathodically Protected Steel
Double-Walled
Not Required
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Yes
Galvanic
2,000
Report Generation Date: 8/31/2016
6/11/2015
Page 25
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
POLY CONOCO
1704 POLY DR
BILLINGS, MT 59102
YELLOWSTONE
Larry Sperry, (406) 245-6944
Owners/Operators: Poly Conoco Inc, Owner
Sys Fac ID: 56-04414
Last Inspected On: 4/7/2016
Operating Permit Renewal Date: 7/14/2019
(406)-245-6944
1704 POLY DR
BILLINGS MT 59102-1729
Lawrence Sperry, UST Class A Operator
Lawrence Sperry, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
4718
Currently in Use
Gasoline
18
2/11/1998
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
4/7/2016
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
4/5/2016
Gilbarco EMC Basic , Gilbarco
2/11/1998
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
4/7/2016
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
4/5/2016
Gilbarco EMC Basic , Gilbarco
2/11/1998
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
4/7/2016
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
4/5/2016
Gilbarco EMC Basic , Gilbarco
10,000
6
4719
Currently in Use
Gasoline
18
7,000
7
4720
Currently in Use
Diesel
18
3,000
Report Generation Date: 8/31/2016
Page 26
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MEADOW GOLD DAIRIES INC BILLINGS
109 S 28TH ST
BILLINGS, MT 59101
YELLOWSTONE
Tim Diet, (406) 252-2118
Owners/Operators: Meadow Gold Dairies Inc Billings, Owner
Sys Fac ID: 56-04464
Last Inspected On: 5/19/2015
Operating Permit Renewal Date: 10/1/2018
(406)-252-2118
109 S 28TH ST
BILLINGS MT 59101-4134
WADE BARMAN, UST Class A Operator
FRANK COOK, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
4264
Currently in Use
Diesel
27
8/7/1989
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
EECO 1500 , EMCO Electronics
Steel
none
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
10,000
Report Generation Date: 8/31/2016
5/19/2015
Page 27
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FIRST STUDENT INC
425 SUGAR AVE PO BOX 31133
BILLINGS, MT 59101
YELLOWSTONE
Fernando Crosa, (406) 248-3667
Owners/Operators: FIRST STUDENT INC, Owner
Sys Fac ID: 56-04467
Last Inspected On: 6/18/2016
Operating Permit Renewal Date:
(513)-241-2200
600 VINE ST STE 1400
CINCINNATI OH 45202-2426
Ronald Messman, UST Class A Operator
Ronald Messman, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
1869
Temporarily Out of Use
Diesel
19
7/25/1997
Fiberglass Reinforced Plastic
Double-Walled
Not Required
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Safe Suction
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
9/28/2011
12,000
Report Generation Date: 8/31/2016
Page 28
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
UNITED PARCEL SERVICE BILLINGS
1830 LAMPMAN DR
BILLINGS, MT 59102
YELLOWSTONE
Scott Oleson, (406) 652-8772
Owners/Operators: United Parcel Service, Inc, Owner
Sys Fac ID: 56-04542
Last Inspected On: 2/19/2016
Operating Permit Renewal Date: 3/22/2019
(503)-978-7678
United Parcel Service Plant Engineering Dept, Operator
(206)-621-6261
6707 N BASIN AVE
PORTLAND OR 97217
4455 7TH AVE S
SEATTLE WA 98108
Robert Counts, UST Class A Operator
Treair Smith, UST Class A Operator
Russell Stott, UST Class A Operator
Paul Vandehey, UST Class A Operator
Robert Counts, UST Class B Operator
Russell Stott, UST Class B Operator
Treair Smith, UST Class B Global Operator
Paul Vandehey, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
23
7/20/1993
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
2/19/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
7/20/1993
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
2/19/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
2183
Currently in Use
Diesel
12,000
6
23
2184
Currently in Use
Gasoline
12,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Page 29
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
STOCKTON OIL CO 4TH AVE N
1607 4TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Joey McConnell, (406) 245-6376
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-04839
Last Inspected On: 11/26/2013
Operating Permit Renewal Date: 12/3/2016
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Mykel Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1988
Currently in Use
Gasoline
6,000
36
3/26/1980
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Impressed Current
5
1989
Currently in Use
Diesel
5,000
24
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
6
1990
Currently in Use
Diesel
8,000
24
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
7
1991
Currently in Use
Gasoline
8,000
24
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
11/1/2013
4/1/1992
11/1/2013
4/1/1992
11/1/2013
Report Generation Date: 8/31/2016
4/1/1992
11/1/2013
Page 30
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
STOCKTON OIL CO 4TH AVE N
1607 4TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Joey McConnell, (406) 245-6376
Sys Fac ID: 56-04839
Last Inspected On: 11/26/2013
Operating Permit Renewal Date: 12/3/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
1992
Currently in Use
Gasoline
8,000
24
4/1/1992
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
9
1993
Currently in Use
Gasoline
8,000
24
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
10
22
Cathodically Protected Steel
None
Fiberglass Reinforced Plastic
None
Not Listed
MLLD Line Tightness Testing, Deferred
11/1/2013
4/1/1992
11/1/2013
Currently in Use
Oil/Water Separator
1,000
Report Generation Date: 8/31/2016
7/1/1994
Automatic Tank Gauging 0.2
Yes
Page 31
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 GS CONVENIENCE CENTER STATE AVE
4410 STATE AVE
BILLINGS, MT 59101
YELLOWSTONE
Larry or Kelly Grosulak, (406) 256-6246
Owners/Operators: SNG Inc 3, Owner
Larry Groslack, Operator
Sys Fac ID: 56-04946
Last Inspected On: 7/22/2013
Operating Permit Renewal Date: 11/5/2016
(406)-245-0161
4410 STATE AVE
(406)-256-6246
BILLINGS MT 59101-5060
4410 STATE AVE
BILLINGS MT 59101-5060
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
03
4/1/2013
Fiberglass Reinforced Plastic
Flexible Plastic
5/1/2013
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Not Listed
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
4/1/2013
Fiberglass Reinforced Plastic
Flexible Plastic
5/1/2013
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Not Listed
5400
Currently in Use
Gasoline
10,000
4
03
5401
Currently in Use
Gasoline
10,000
Report Generation Date: 8/31/2016
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Page 32
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 GS CONVENIENCE CENTER STATE AVE
4410 STATE AVE
BILLINGS, MT 59101
YELLOWSTONE
Larry or Kelly Grosulak, (406) 256-6246
Sys Fac ID: 56-04946
Last Inspected On: 7/22/2013
Operating Permit Renewal Date: 11/5/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
03
4/1/2013
Fiberglass Reinforced Plastic
Flexible Plastic
5/1/2013
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Not Listed
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
5402
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Yes
Page 33
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SOCO EXPRESS 10
5400 LAUREL RD
BILLINGS, MT 59101
YELLOWSTONE
Michael Stockton, (406) 245-6376
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-04951
Last Inspected On: 3/5/2015
Operating Permit Renewal Date:
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
1994
Temporarily Out of Use
Gasoline
25
5/1/1991
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Galvanic
2/9/2015
8,000
6
1995
Temporarily Out of Use
Gasoline
1/15/2005
25
2/9/2015
8,000
7
1996
Temporarily Out of Use
Gasoline
11/5/2008
25
5/1/1991
2/9/2015
8,000
8
1997
Temporarily Out of Use
Diesel
5/1/1991
11/5/2008
25
8,000
Report Generation Date: 8/31/2016
5/1/1991
2/9/2015
11/5/2008
Page 34
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SOCO EXPRESS 10
5400 LAUREL RD
BILLINGS, MT 59101
YELLOWSTONE
Michael Stockton, (406) 245-6376
Sys Fac ID: 56-04951
Last Inspected On: 3/5/2015
Operating Permit Renewal Date:
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
9
1998
Temporarily Out of Use
Diesel
25
5/1/1991
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Galvanic
15,000
Report Generation Date: 8/31/2016
2/9/2015
11/5/2008
Page 35
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SOCO EXPRESS
1503 GRAND AVE
BILLINGS, MT 59102
(406) 256-0386
Sys Fac ID: 56-04954
Last Inspected On: 2/12/2014
Operating Permit Renewal Date:
YELLOWSTONE
Owners/Operators: Stockton Oil Company, Owner
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Joey McConnell, UST Class B Global Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Mykel Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
28
6/1/1988
Cathodically Protected Steel
Steel
2/12/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
none
Pressurized
Stat. Inventory Reconcilitation
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
3/26/1986
Cathodically Protected Steel
Steel
2/12/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
none
Pressurized
Stat. Inventory Reconcilitation
3/26/1986
Cathodically Protected Steel
Steel
2/12/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
none
Pressurized
Stat. Inventory Reconcilitation
3780
Temporarily Out of Use
Gasoline
10,000
4
30
3781
Temporarily Out of Use
Gasoline
10,000
5
30
3782
Temporarily Out of Use
Gasoline
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 36
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SOCO EXPRESS 15TH & BROADWATER
1503 BROADWATER AVE
BILLINGS, MT 59102
YELLOWSTONE
Mykel Stockton, (406) 245-6376
Owners/Operators: Stockton Oil Company, Owner/Operator
Sys Fac ID: 56-04956
Last Inspected On: 12/23/2014
Operating Permit Renewal Date: 2/19/2018
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Mykel Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
39
3/26/1977
Cathodically Protected Steel
Fiberglass Reinforced Plastic
12/22/2014
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, MLLD Line
Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
3/26/1969
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
12/22/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, MLLD Line
Tightness Testing
3/26/1969
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
12/22/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, MLLD Line
Tightness Testing
3751
Temporarily Out of Use
Gasoline
8,000
2
47
3752
Temporarily Out of Use
Gasoline
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
8,000
3
47
3753
Temporarily Out of Use
Gasoline
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
8,000
Report Generation Date: 8/31/2016
Page 37
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 GS CONVENIENCE CENTER E WICKS LANE
1221 WICKS LN
BILLINGS, MT 59105
YELLOWSTONE
Larry Grosulak, (406) 670-0085
Owners/Operators: SNG Inc 3, Owner
Sys Fac ID: 56-04957
Last Inspected On: 3/30/2015
Operating Permit Renewal Date: 3/31/2018
(406)-245-0161
4410 STATE AVE
BILLINGS MT 59101-5060
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
5532
Currently in Use
Gasoline
01
9/14/2014
12/17/2014
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TS-550 EVO , Incon
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor, Not Listed
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TS-550 EVO , Incon
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor, Not Listed
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TS-550 EVO , Incon
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor, Not Listed
High Level Alarm
Yes
Not Applicable
10,000
4
5533
Currently in Use
Gasoline
12/17/2014
01
10,000
5
5534
Currently in Use
Diesel
9/14/2014
12/17/2014
12/17/2014
01
10,000
Report Generation Date: 8/31/2016
9/14/2014
12/17/2014
12/17/2014
Page 38
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
PACIFIC SUPPLY
600 DANIEL ST
BILLINGS, MT 59101
YELLOWSTONE
Dennis Yonts, (406) 254-8876
Owners/Operators: Pacific Coast Building Products, Owner
Dennis Yonts, Operator
Sys Fac ID: 56-04965
Last Inspected On: 3/14/2014
Operating Permit Renewal Date: 5/14/2017
(916)-971-2301
(406)-245-8876
PO BOX 419074
RANCHO CORDOVA CA 95741-9074
600 DANIEL ST
BILLINGS MT 59101-0637
Ryan Eklund, UST Class A Operator
Kate Renner, UST Class A Operator
Dennis Yonts, UST Class A Operator
Ryan Eklund, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
22
11/1/1993
Fiberglass Reinforced Plastic
Steel
Double-Walled
Not Required
Continuous Interstitial Monitor
Double-Walled
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
4350
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Page 39
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Automatic Carwash Inc
2344 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Michael Stockton, (406) 245-6376
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 56-05072
Last Inspected On: 7/17/2014
Operating Permit Renewal Date: 9/25/2017
(406)-248-2558
Stockton Oil Company, Owner
(406)-245-6376
PO BOX 1278
BILLINGS MT 59103-1278
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Christopher Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
2002
Currently in Use
Gasoline
20,000
21
11/8/1994
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
6
2003
Currently in Use
Gasoline
10,000
21
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
7
2004
Currently in Use
Gasoline
10,000
21
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
6/19/2014
7/17/2014
11/8/1994
6/19/2014
7/17/2014
Report Generation Date: 8/31/2016
11/8/1994
6/19/2014
7/17/2014
Page 40
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
LOCKWOOD INTERSTATE EXXON
1031 US HIGHWAY 87 E
BILLINGS, MT 59101
YELLOWSTONE
Michael Stockton, (406) 245-6376
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-05074
Last Inspected On: 1/30/2015
Operating Permit Renewal Date: 2/7/2018
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Mykel Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
2006
Temporarily Out of Use
Diesel
22
11/1/1993
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
12/12/2014
6,000
2
2005
Temporarily Out of Use
Diesel
6/25/2014
22
12/12/2014
8,000
7
3677
Temporarily Out of Use
Gasoline
11/1/1993
6/25/2014
28
8,000
Report Generation Date: 8/31/2016
11/30/1987
12/12/2014
6/25/2014
Page 41
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
LOCKWOOD INTERSTATE EXXON
1031 US HIGHWAY 87 E
BILLINGS, MT 59101
YELLOWSTONE
Michael Stockton, (406) 245-6376
Sys Fac ID: 56-05074
Last Inspected On: 1/30/2015
Operating Permit Renewal Date: 2/7/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
9
3676
Temporarily Out of Use
Gasoline
28
11/30/1987
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
12/12/2014
10,000
10
3675
Temporarily Out of Use
Gasoline
6/25/2014
28
10,000
Report Generation Date: 8/31/2016
11/30/1987
12/12/2014
6/25/2014
Page 42
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MERIDIAN AUTOMOTIVE SERVICE INC
1240 AVENUE C
BILLINGS, MT 59102
YELLOWSTONE
Richard Skewis, (406) 259-6922
Owners/Operators: Meridian Automotive Service LLC, Owner
Sys Fac ID: 56-05077
Last Inspected On: 7/10/2015
Operating Permit Renewal Date:
(406)-259-6922
1240 AVENUE C
BILLINGS MT 59102-3238
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
3182
Temporarily Out of Use
Gasoline
22
1/11/1994
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
none
Safe Suction
Not Listed
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
none
Safe Suction
Not Listed
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
none
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
7/2/2015
2,000
6
3183
Temporarily Out of Use
Gasoline
22
1/11/1994
7/2/2015
4,000
7
3184
Temporarily Out of Use
Gasoline
22
6,000
Report Generation Date: 8/31/2016
1/11/1994
7/2/2015
Page 43
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CASEY'S CORNER #10
3443 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Jason Shanley, (406) 587-0702
Owners/Operators: Story Distributing Co, Owner
Sys Fac ID: 56-05085
Last Inspected On: 4/1/2016
Operating Permit Renewal Date: 6/14/2019
(406)-587-0702
Jason Shanley, Operator
(406)-587-0702
PO BOX 1201
BOZEMAN MT 59771-1201
PO BOX 1201
BOZEMAN MT 59771-1201
Jeffrey Fletcher, UST Class A Operator
Gary Scales, UST Class A Operator
Ethan Granzow, UST Class B Operator
Gary Scales, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
21
5/1/1995
Cathodically Protected Steel
Flexible Plastic
2009
Currently in Use
Diesel
6/30/2014
2/16/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
6,000
1/7/2016
TLS-450 , Veeder Root
5/1/1995
Cathodically Protected Steel
Flexible Plastic
6/30/2014
2/16/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
1/7/2016
TLS-450 , Veeder Root
5/1/1995
Cathodically Protected Steel
Flexible Plastic
4473
Currently in Use
Gasoline
6/30/2014
2/16/2016
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
8,000
1/7/2016
TLS-450 , Veeder Root
6
21
2007
Currently in Use
Gasoline
4,000
7
21
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 44
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 G'S CONVENIENCE STORE
1425 US HIGHWAY 87 E
BILLINGS, MT 59101
YELLOWSTONE
(406) 252-9763
Owners/Operators: VESTA VENTURES LLP, Owner
Sys Fac ID: 56-05086
Last Inspected On: 11/16/2013
Operating Permit Renewal Date: 12/31/2016
(406)-656-8402
5629 BILLY CASPER DR
BILLINGS MT 59106-1053
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
JERRY KLEIN, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
JERRY KLEIN, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1151
Currently in Use
Diesel
10,000
41
4/25/1975
Bare Steel
Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Impressed Current
2
1152
Currently in Use
Gasoline
4,000
41
Bare Steel
Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Impressed Current
3
1153
Currently in Use
Gasoline
4,000
41
Bare Steel
Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Impressed Current
9/11/2013
9/11/2013
4/25/1975
9/11/2013
9/11/2013
Report Generation Date: 8/31/2016
4/25/1975
9/11/2013
9/11/2013
Page 45
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONO MART SUPER STORE 10
11 W WICKS LN
BILLINGS, MT 59105
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Owners/Operators: B & A Holding LLC, Owner
Sys Fac ID: 56-05088
Last Inspected On: 11/21/2014
Operating Permit Renewal Date: 3/3/2018
(406)-252-4661
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 30335
BILLINGS MT 59107
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
Mark Zinnecker, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
25
11/16/1990
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
High Level Alarm, Ball
Float Valve
Yes
Galvanic
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
1156
Currently in Use
Gasoline
11/21/2014
6,000
9/18/2011
2
25
11/16/1990
1154
Currently in Use
Gasoline
11/21/2014
10,000
9/18/2011
Report Generation Date: 8/31/2016
High Level Alarm, Ball
Float Valve
Yes
Galvanic
Page 46
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONO MART SUPER STORE 10
11 W WICKS LN
BILLINGS, MT 59105
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-05088
Last Inspected On: 11/21/2014
Operating Permit Renewal Date: 3/3/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
25
11/16/1990
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
High Level Alarm, Ball
Float Valve
Yes
Galvanic
1155
Currently in Use
Gasoline
11/21/2014
8,000
9/18/2011
Report Generation Date: 8/31/2016
Page 47
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MCFINYS #2
3306 RIMROCK RD
BILLINGS, MT 59102
YELLOWSTONE
Ken McCullough, (406) 861-3952
Owners/Operators: VESTA VENTURES LLP, Owner
Sys Fac ID: 56-05090
Last Inspected On: 1/27/2016
Operating Permit Renewal Date: 6/14/2019
(406)-656-8402
MCFINNY'S, Operator
5629 BILLY CASPER DR
BILLINGS MT 59106-1053
2108 BROADWATER AVE STE 102
BILLINGS MT 59102
Joe McCullough, UST Class A Operator
Ken McCullough, UST Class A Operator
Joe McCullough, UST Class B Operator
Ken McCullough, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
28
11/30/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1/26/2016
1/26/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Gilbarco EMC Basic , Gilbarco
None
Pressurized
MLLD Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
11/30/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1/26/2016
1/26/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Gilbarco EMC Basic , Gilbarco
None
Pressurized
MLLD Line Tightness Testing
11/30/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1/26/2016
1/26/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Gilbarco EMC Basic , Gilbarco
None
Pressurized
MLLD Line Tightness Testing
3681
Currently in Use
Gasoline
10,000
2
28
3682
Currently in Use
Gasoline
10,000
3
28
3683
Currently in Use
Gasoline
8,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 48
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS CAR WASH GRAND AVE
1125 GRAND AVE
BILLINGS, MT 59102
YELLOWSTONE
Gary Carlson, (406) 259-4955
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 56-05491
Last Inspected On: 11/4/2014
Operating Permit Renewal Date: 2/10/2018
(406)-248-2558
PO BOX 1278
BILLINGS MT 59103-1278
Gene Carlson, UST Class A Operator
Gene Carlson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
406
Currently in Use
Gasoline
28
5/4/1988
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
High Level Alarm
Yes
Galvanic
11/4/2014
10,000
3
407
Currently in Use
Gasoline
12/3/2011
28
11/4/2014
10,000
4
408
Currently in Use
Diesel
5/4/1988
12/4/2011
28
6,000
Report Generation Date: 8/31/2016
5/4/1988
11/4/2014
5/15/2011
Page 49
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS CAR WASH CENTRAL AVE
2343 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Gene Carlson, (406) 656-7051
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 56-05492
Last Inspected On: 10/23/2014
Operating Permit Renewal Date: 2/10/2018
(406)-248-2558
PO BOX 1278
BILLINGS MT 59103-1278
Gene Carlson, UST Class A Operator
Gene Carlson, UST Class B Operator
Jamie Gehring, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
409
Currently in Use
Gasoline
10,000
26
5/1/1990
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
Automatic Tank Gauging 0.1
High Level Alarm
Yes
Galvanic
5
4467
Currently in Use
Gasoline
10,000
26
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
Automatic Tank Gauging 0.1
High Level Alarm
Yes
Galvanic
6
411
Currently in Use
Diesel
6,000
26
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
Automatic Tank Gauging 0.1
High Level Alarm
Yes
Galvanic
10/23/2014
10/12/2014
5/1/1990
10/23/2014
7/3/2014
Report Generation Date: 8/31/2016
5/1/1990
10/23/2014
7/3/2014
Page 50
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 Gs CONVENIENCE STORE
4106 STATE AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 259-0995
Owners/Operators: VESTA VENTURES LLP, Owner
Sys Fac ID: 56-05748
Last Inspected On: 12/3/2014
Operating Permit Renewal Date: 1/6/2018
(406)-656-8402
5629 BILLY CASPER DR
BILLINGS MT 59106-1053
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
4714
Currently in Use
Gasoline
14
8/23/2002
5/3/2016
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
12/3/2014
9,000
4
4715
Currently in Use
Gasoline
5/13/2016
14
3,000
Report Generation Date: 8/31/2016
8/23/2002
5/3/2016
12/3/2014
5/13/2016
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
Continuous Interstitial Monitor
Page 51
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MCFINY'S 3
446 GRAND AVE
BILLINGS, MT 59101
(406) 259-0466
Sys Fac ID: 56-05749
Last Inspected On: 10/16/2014
Operating Permit Renewal Date: 1/6/2018
YELLOWSTONE
Owners/Operators: Kwik Way Inc, Owner
(406)-656-6310
THERESA J JENKINS
PO BOX 20799
BILLINGS MT 59104-0799
Ken McCullough, UST Class A Operator
Ken McCullough, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
3456
Currently in Use
Gasoline
10,000
18
11/1/1997
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
6
3457
Currently in Use
Gasoline
10,000
18
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
10/16/2014
10/11/2014
Report Generation Date: 8/31/2016
11/1/1997
10/16/2014
10/11/2014
Page 52
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
24TH STREET CENEX
1031 24TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Teresa Bidleman, (406) 652-1529
Owners/Operators: Quast Inc, Owner
Sys Fac ID: 56-05750
Last Inspected On: 10/5/2015
Operating Permit Renewal Date: 2/5/2019
(406)-652-1529
1031 24TH ST W
BILLINGS MT 59102-3807
Teresa Bidleman, UST Class A Operator
Jeff Bidleman, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3720
Currently in Use
Gasoline
31
9/1/1984
5/2/2015
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
3/20/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
9/1/1984
8/17/2015
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
3/20/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
10,000
2
3721
Currently in Use
Gasoline
31
10,000
Report Generation Date: 8/31/2016
Page 53
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS CAR WASH
1433 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Bob Carlson, (406) 256-1941
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 56-05755
Last Inspected On: 3/30/2015
Operating Permit Renewal Date: 5/14/2018
(406)-248-2558
PO BOX 1278
BILLINGS MT 59103-1278
Gene Carlson, UST Class A Operator
Gene Carlson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
5030
Currently in Use
Gasoline
10
11/10/2005
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
3/30/2015
12,000
5
5031
Currently in Use
Gasoline
7/4/2011
10
3/30/2015
6,000
6
5032
Currently in Use
Diesel
11/10/2005
7/4/2011
10
6,000
Report Generation Date: 8/31/2016
11/10/2005
3/30/2015
7/8/2011
Page 54
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
AT & T COMMUNICATIONS BILLINGS
3011 2ND AVE N
BILLINGS, MT 59101
YELLOWSTONE
Gary Donnovan, (406) 256-6607
Owners/Operators: AT & T Communications Inc, Owner
Sys Fac ID: 56-05758
Last Inspected On: 11/23/2015
Operating Permit Renewal Date: 3/9/2019
(214)-464-1469
ENVIRONMENTAL MANAGER
308 S AKARD ST RM 1700
DALLAS TX 75202-5315
Philip Bunker, UST Class A Operator
Gerald Eshbaugh, UST Class A Operator
Richard Powell, UST Class A Operator
Gary Vantress, UST Class A Operator
Gary Vantress, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
21
9/1/1994
Cathodically Protected Steel
Fiberglass Reinforced Plastic
11/23/2015
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
399
Currently in Use
Diesel
8,000
Report Generation Date: 8/31/2016
Page 55
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SUPER VALU INC BILLINGS
1629 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Scott Armstrong, (406) 247-1513
Owners/Operators: Super Valu Inc Billings Distribution Center, Owner
Sys Fac ID: 56-06097
Last Inspected On: 6/3/2016
Operating Permit Renewal Date: 8/28/2019
(406)-761-8444
1629 KING AVE W
BILLINGS MT 59102-6448
John Beadle, UST Class A Operator
Scott Combs, UST Class A Operator
Mike Frost, UST Class A Operator
Jeffrey Lindell, UST Class A Operator
John Beadle, UST Class B Operator
Steve Schilling, UST Class B Operator
Scott Combs, UST Class B Global Operator
Mike Frost, UST Class B Global Operator
Jeffrey Lindell, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
1867
Currently in Use
Diesel
17
9/1/1998
Cathodically Protected Steel
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
4/18/2016
12,000
5
1868
Currently in Use
Diesel
17
10,000
Report Generation Date: 8/31/2016
9/1/1998
4/18/2016
Page 56
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FOOD SERVICES OF AMERICA BILLINGS
802 PARKWAY LN
BILLINGS, MT 59101
YELLOWSTONE
Kevin Malley, (406) 238-7800
Owners/Operators: Food Services Of America Inc, Owner
Sys Fac ID: 56-06132
Last Inspected On: 11/1/2013
Operating Permit Renewal Date: 12/14/2016
(406)-238-7800
PO BOX 25119
SCOTTSDALE AZ 85255-0178
Jeff Brent, UST Class A Operator
Rick Hansen, UST Class A Operator
Rod Ostman, UST Class A Operator
Jeff Brent, UST Class B Operator
Larry Hoye, UST Class B Operator
Rodney Hunt, UST Class B Operator
Duane Young, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
1781
Currently in Use
Diesel
12,000
22
11/2/1993
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.2
Steel
none
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Report Generation Date: 8/31/2016
11/1/2013
Page 57
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BLUE BASKET #2
2347 MAIN ST
BILLINGS, MT 59105
(406) 252-7679
Sys Fac ID: 56-06593
Last Inspected On: 2/21/2014
Operating Permit Renewal Date: 4/25/2017
YELLOWSTONE
Owners/Operators: Blue Basket Markets Billings, Owner
(406)-252-0166
PO BOX 531
BILLINGS MT 59103-0531
Brit Miller, UST Class A Operator
Steve Berg, UST Class B Operator
Randy Lowe, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
459
Currently in Use
Diesel
34
10/1/1981
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
1/24/2014
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/6/2010
TLS-350/Gilbarco EMC , Veeder Root
10/1/1981
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
1/24/2014
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/6/2010
TLS-350/Gilbarco EMC , Veeder Root
10/1/1981
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
1/24/2014
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/6/2010
TLS-350/Gilbarco EMC , Veeder Root
6,000
2
460
Currently in Use
Gasoline
34
10,000
3
461
Currently in Use
Gasoline
34
10,000
Report Generation Date: 8/31/2016
Page 58
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Caseys #8
2816 OLD HARDIN RD
BILLINGS, MT 59101
YELLOWSTONE
Gary Scales, (406) 587-7438
Owners/Operators: Story Distributing Company, Owner
Jason Shanley, Operator
Sys Fac ID: 56-06594
Last Inspected On: 1/21/2015
Operating Permit Renewal Date: 2/28/2018
(406)-587-0702
(406)-587-0702
PO BOX 1201
BOZEMAN MT 59771
PO BOX 1201
BOZEMAN MT 59771-1201
Jason Shanley, UST Class A Operator
Chuck Crane, UST Class B Operator
Andrew Mclellan, UST Class B Operator
Jason Shanley, UST Class B Operator
STEVE WILLDEN, UST Class B Operator
Kelly Scott Shutes, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
18
5/1/1998
Fiberglass Reinforced Plastic
Flexible Plastic
8/25/2011
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm,
Positive Shutoff
Yes
Not Applicable
5/1/1998
Fiberglass Reinforced Plastic
Flexible Plastic
8/25/2011
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing, ELLD Line Tightness Testing
Continuous Interstitial Monitor
462
Currently in Use
Gasoline
20,000
5
18
463
Currently in Use
Gasoline
10,000
6
464
Currently in Use
Gasoline
18
8,000
Report Generation Date: 8/31/2016
5/1/1998
8/25/2011
High Level Alarm,
Positive Shutoff
Yes
Not Applicable
High Level Alarm
Yes
Not Applicable
Page 59
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Caseys #8
2816 OLD HARDIN RD
BILLINGS, MT 59101
YELLOWSTONE
Gary Scales, (406) 587-7438
Sys Fac ID: 56-06594
Last Inspected On: 1/21/2015
Operating Permit Renewal Date: 2/28/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
7
465
Currently in Use
Diesel
18
5/1/1998
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
8,000
Report Generation Date: 8/31/2016
8/25/2011
Page 60
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Caseys #7
2007 BLUE CREEK RD
BILLINGS, MT 59101
YELLOWSTONE
Jason Shanley, (406) 587-7438
Owners/Operators: Central Holdings LLC, Owner
Sys Fac ID: 56-06595
Last Inspected On: 9/26/2014
Operating Permit Renewal Date: 11/29/2017
(406)-587-0702
Jason Shanley, Operator
(406)-587-0702
PO BOX 1201
BOZEMAN MT 59771
PO BOX 1201
BOZEMAN MT 59771-1201
Jason Shanley, UST Class A Operator
Irene Matzen, UST Class B Operator
Jason Shanley, UST Class B Operator
Melanie Sims, UST Class B Operator
Kelly Scott Shutes, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
466
Currently in Use
Diesel
6,000
23
11/2/1992
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
4
467
Currently in Use
Gasoline
8,000
23
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
5
468
Currently in Use
Gasoline
8,000
23
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
ELLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
9/19/2014
7/24/2014
11/2/1992
9/19/2014
7/28/2014
Report Generation Date: 8/31/2016
11/2/1992
9/19/2014
8/7/2014
Page 61
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SHORT STOP
804 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Joe Stockton, (406) 591-7332
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-06609
Last Inspected On: 8/28/2013
Operating Permit Renewal Date: 10/26/2016
(406)-245-6376
PO BOX 1756
BILLINGS MT 59103-1756
Mykel Stockton, UST Class A Operator
Joey McConnell, UST Class B Global Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
35
3/26/1981
Cathodically Protected Steel
Steel
8/23/2013
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, Deferred
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
3/26/1981
Cathodically Protected Steel
Steel
8/23/2013
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
3/26/1981
Cathodically Protected Steel
Steel
8/23/2013
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
3754
Temporarily Out of Use
Gasoline
8,000
2
35
3899
Temporarily Out of Use
Gasoline
8,000
3
35
4920
Temporarily Out of Use
Gasoline
8,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Page 62
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SHORT STOP
804 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Joe Stockton, (406) 591-7332
Sys Fac ID: 56-06609
Last Inspected On: 8/28/2013
Operating Permit Renewal Date: 10/26/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
35
3/26/1981
Cathodically Protected Steel
Steel
8/23/2013
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
4921
Temporarily Out of Use
Gasoline
8,000
Report Generation Date: 8/31/2016
Page 63
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONO MART SUPER STORE 6
1219 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-06948
Last Inspected On: 11/21/2014
Operating Permit Renewal Date: 1/28/2018
Owners/Operators: C Store Properties LLC, Owner
(406)-651-5101
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Troy Davis, UST Class B Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3618
Currently in Use
Gasoline
40
4/21/1976
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
none
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
none
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
11/21/2014
10,000
2
3619
Currently in Use
Gasoline
10/16/2011
45
10,000
Report Generation Date: 8/31/2016
4/22/1971
11/21/2014
6/28/2011
Page 64
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONO MART SUPER STORE 6
1219 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-06948
Last Inspected On: 11/21/2014
Operating Permit Renewal Date: 1/28/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
3620
Currently in Use
Gasoline
45
4/22/1971
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
none
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
4,000
Report Generation Date: 8/31/2016
11/21/2014
9/28/2011
Page 65
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
REDDI ELECTRIC INC
1045 1/2 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Mike Schmidt, (406) 245-3141
Owners/Operators: Reddi Electric Inc, Owner
Sys Fac ID: 56-06953
Last Inspected On: 4/22/2015
Operating Permit Renewal Date: 9/16/2018
(406)-245-3141
1045 1/2 CENTRAL AVE
BILLINGS MT 59102-5821
Darin Linger, UST Class A Operator
Mike Schmidt, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
29
1/10/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
4/21/2015
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-300 , Veeder Root
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
1837
Currently in Use
Gasoline
560
Report Generation Date: 8/31/2016
Page 66
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS CAR WASH 1ST AVE
1924 1ST AVE N
BILLINGS, MT 59101
YELLOWSTONE
Bob Carlson, (406) 259-3539
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 56-06956
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/10/2018
(406)-248-2558
PO BOX 1278
BILLINGS MT 59103-1278
Gene Carlson, UST Class A Operator
Dick Berg, UST Class B Operator
Gene Carlson, UST Class B Operator
Gene Carlson, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
412
Currently in Use
Gasoline
27
11/11/1988
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
11/11/1998
12/21/2005
10,000
6
413
Currently in Use
Gasoline
TLS-350/Gilbarco EMC , Veeder Root
27
11/11/1988
11/1/2011
6,000
7
414
Currently in Use
Diesel
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
27
6,000
Report Generation Date: 8/31/2016
11/11/1988
12/2/2011
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Page 67
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HEIGHTS CONOCO 13 UST
1320 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Timothy Gross, (406) 259-3709
Owners/Operators: TAG Inc, Owner
Sys Fac ID: 56-06960
Last Inspected On: 7/18/2013
Operating Permit Renewal Date: 12/12/2016
(406)-259-3700
1320 MAIN ST
BILLINGS MT 59105-1742
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
40
4/21/1976
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1164
Currently in Use
5/1/2005
Lined Interior/Impressed Current
Mechanical Line Leak Detector
None
Pressurized
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Gasoline
10,000
7/18/2013
7/18/2013
Stat. Inventory Reconcilitation
MLLD Line Tightness Testing
4/21/1976
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1165
Currently in Use
5/1/2005
Lined Interior/Impressed Current
Mechanical Line Leak Detector
None
Pressurized
Gasoline
10,000
7/18/2013
7/18/2013
Stat. Inventory Reconcilitation
MLLD Line Tightness Testing
4/21/1976
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1166
Currently in Use
5/1/2005
Lined Interior/Impressed Current
Mechanical Line Leak Detector
None
Pressurized
Gasoline
5,000
7/18/2013
7/18/2013
Stat. Inventory Reconcilitation
MLLD Line Tightness Testing
2
3
40
40
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Page 68
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
GM PETROLEUM DISTRIBUTORS
2100 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Jay Brookie, (406) 294-0865
Owners/Operators: City Service Valcon LLC DBA GM Petroleum Distributors,
Owner/Operator
Laura Geffre, UST Class A Operator
Roger Schmechel, UST Class A Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
Sys Fac ID: 56-06962
Last Inspected On: 12/15/2014
Operating Permit Renewal Date: 3/14/2018
(406)-252-4661
PO BOX 30335
BILLINGS MT 59101
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1167
Currently in Use
Diesel
31
6/1/1985
Bare Steel
Impressed Current
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Safe Suction
Not Listed
High Level Alarm
Yes
Impressed Current
Bare Steel
Impressed Current
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Safe Suction
Not Listed
High Level Alarm
Yes
Impressed Current
Bare Steel
Impressed Current
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Safe Suction
Not Listed
High Level Alarm
Yes
Impressed Current
6/28/2012
6,000
2
1168
Currently in Use
Diesel
31
6/1/1985
6/28/2012
6,000
3
1169
Currently in Use
Diesel
31
6,000
Report Generation Date: 8/31/2016
6/1/1985
6/28/2012
Page 69
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
GM PETROLEUM DISTRIBUTORS
2100 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Jay Brookie, (406) 294-0865
Sys Fac ID: 56-06962
Last Inspected On: 12/15/2014
Operating Permit Renewal Date: 3/14/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
4626
Currently in Use
Gasoline
31
6/1/1985
Bare Steel
Impressed Current
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Safe Suction
Not Listed
High Level Alarm
Yes
Impressed Current
Bare Steel
Impressed Current
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Gravity Feed
Deferred
High Level Alarm
Yes
Impressed Current
6/28/2012
6,000
5
4627
Currently in Use
Waste Oil
33
1,000
Report Generation Date: 8/31/2016
5/7/1983
6/28/2012
Page 70
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TRADING POST CONOCO
1225 MULLOWNEY LN
BILLINGS, MT 59101
YELLOWSTONE
Jeff Sowden, (406) 256-8465
Owners/Operators: S & G Partnership, Owner
Sys Fac ID: 56-06963
Last Inspected On: 10/14/2013
Operating Permit Renewal Date: 11/30/2016
(406)-252-4661
1225 MULLOWNEY LN
BILLINGS MT 59101-6301
Jeffrey Sowden, UST Class A Operator
Jeffrey Sowden, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
4836
Currently in Use
Gasoline
13
5/9/2003
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Not Applicable
10/14/2013
12,000
6
4837
Currently in Use
Gasoline
6/18/2010
13
10/14/2013
4,000
7
4838
Currently in Use
Gasoline
6/18/2010
13
5/9/2003
10/14/2013
4,000
8
4839
Currently in Use
Diesel
5/9/2003
6/18/2010
13
4,000
Report Generation Date: 8/31/2016
5/9/2003
10/14/2013
6/18/2010
Page 71
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DOWNTOWN CONOCO
2701 6TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 254-1401
Owners/Operators: Grunstead Family Limited Partnership, Owner
J & L Properties Management Inc, Operator
Sys Fac ID: 56-06967
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 1/28/2018
(406)-252-4661
(406)-254-1401
PO BOX 30335
BILLINGS MT 59107
2701 6TH AVE N
BILLINGS MT 59101
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Jim Murphy, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Laura Geffre, UST Class B Operator
Jim Murphy, UST Class B Operator
Roger Schmechel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3621
Currently in Use
Gasoline
48
4/22/1968
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
High Level Alarm
Yes
Impressed Current
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
High Level Alarm
Yes
Impressed Current
8/26/2010
8,000
2
3622
Currently in Use
Gasoline
12/1/2011
46
6,000
Report Generation Date: 8/31/2016
4/22/1970
8/26/2010
11/7/2011
Page 72
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DOWNTOWN CONOCO
2701 6TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 254-1401
Sys Fac ID: 56-06967
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 1/28/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
3623
Currently in Use
Gasoline
42
4/22/1974
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Impressed Current
6,000
Report Generation Date: 8/31/2016
8/26/2010
11/9/2011
Page 73
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
WILSON DUNHAM SERVICE INC
2511 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Joan Erickson, (406) 724-7335
Owners/Operators: Wilson Dunham Petroleum Supply, Owner
Erick Forum, Operator
Sys Fac ID: 56-07756
Last Inspected On: 4/10/2014
Operating Permit Renewal Date: 6/3/2017
(406)-252-0880
(406)-724-7335
2511 1ST AVE S
BILLINGS MT 59101-2320
2511 1ST AVE S
BILLINGS MT 59101
William Dunham, UST Class A Operator
Joan Erickson, UST Class A Operator
Joan Erickson, UST Class B Operator
William Dunham, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
2277
Currently in Use
Diesel
4,000
25
11/16/1990
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
6
2278
Currently in Use
Gasoline
25
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
4/8/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/4/2013
TLS-350/Gilbarco EMC , Veeder Root
11/16/1990
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
4/8/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/4/2013
TLS-350/Gilbarco EMC , Veeder Root
4/8/2014
4,000
7
2279
Currently in Use
Gasoline
25
4,000
Report Generation Date: 8/31/2016
11/16/1990
Page 74
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
WILSON DUNHAM SERVICE INC
2511 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Joan Erickson, (406) 724-7335
Sys Fac ID: 56-07756
Last Inspected On: 4/10/2014
Operating Permit Renewal Date: 6/3/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
2280
Currently in Use
Gasoline
25
11/16/1990
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
4/8/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
11/4/2013
TLS-350/Gilbarco EMC , Veeder Root
8,000
Report Generation Date: 8/31/2016
Page 75
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
LYNCH FLYING SERVICE
1691 AVIATION PL
BILLINGS, MT 59105
YELLOWSTONE
Warren Nemitz, (406) 252-0508
Owners/Operators: LYNCH FLYING SERVICE INC, Owner
Sys Fac ID: 56-07797
Last Inspected On: 10/8/2015
Operating Permit Renewal Date: 12/17/2018
(406)-252-0508
DBA EDWARDS JET CENTER
1691 AVIATION PL
BILLINGS MT 59105-1981
Warren Nemitz, UST Class A Operator
Joel Simmons, UST Class A Operator
Aaron VanLuchene, UST Class A Operator
Joel Simmons, UST Class B Operator
Warren Nemitz, UST Class B Global Operator
Aaron VanLuchene, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1565
Currently in Use
Jet Fuel
25
10/25/1990
Cathodically Protected Steel
Lined Interior
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Steel
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
10/8/2015
20,000
2
1566
Currently in Use
Aviation Gas
25
10/25/1990
10/8/2015
20,000
3
1567
Currently in Use
Gasoline
25
10,000
Report Generation Date: 8/31/2016
10/25/1990
10/8/2015
Page 76
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
LYNCH FLYING SERVICE
1691 AVIATION PL
BILLINGS, MT 59105
YELLOWSTONE
Warren Nemitz, (406) 252-0508
Sys Fac ID: 56-07797
Last Inspected On: 10/8/2015
Operating Permit Renewal Date: 12/17/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
11
1563
Currently in Use
Jet Fuel
25
10/25/1990
Cathodically Protected Steel
Lined Interior
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
Lined Interior
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
10/8/2015
20,000
12
1564
Currently in Use
Jet Fuel
25
10/25/1990
10/8/2015
20,000
13
1568
Currently in Use
Jet Fuel
18
6/26/1998
10/8/2015
20,000
14
1569
Currently in Use
Jet Fuel
18
20,000
Report Generation Date: 8/31/2016
6/26/1998
10/8/2015
Page 77
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 266
745 GRAND AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 248-7038
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-08058
Last Inspected On: 8/1/2016
Operating Permit Renewal Date: 11/20/2019
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Stephen Reckinger, UST Class A Operator
Courtney Sheriff, UST Class B Operator
Linda French, UST Class B Global Operator
Travis Struckman, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3039
Currently in Use
Diesel
21
6/8/1995
6/8/2005
7/29/2016
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Not Applicable
3/23/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
6/8/1995
6/8/2005
7/29/2016
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
3/23/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
6/8/1995
6/8/2005
7/29/2016
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
3/23/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
8,000
2
3036
Currently in Use
Gasoline
21
12,000
3
3037
Currently in Use
Gasoline
21
8,000
Report Generation Date: 8/31/2016
Page 78
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 266
745 GRAND AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 248-7038
Sys Fac ID: 56-08058
Last Inspected On: 8/1/2016
Operating Permit Renewal Date: 11/20/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
3038
Currently in Use
Gasoline
21
6/8/1995
6/8/2005
7/29/2016
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
3/23/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
8,000
Report Generation Date: 8/31/2016
Page 79
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 274
2620 6TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
(406) 248-7037
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-08062
Last Inspected On: 7/28/2016
Operating Permit Renewal Date: 10/29/2019
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Stephen Reckinger, UST Class A Operator
Dean Townsend, UST Class A Operator
Ronald VanDenBroeke, UST Class A Operator
Michael Boileau, UST Class B Operator
Linda French, UST Class B Global Operator
Stephen Reckinger, UST Class B Global Operator
Travis Struckman, UST Class B Global Operator
Dean Townsend, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
3040
Currently in Use
Gasoline
20
10/1/1995
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
10/1/2005
8/23/2013
8,000
5
4399
Currently in Use
Gasoline
12/25/2009
20
10/1/2005
8/23/2013
8,000
6
3042
Currently in Use
Gasoline
10/1/1995
12/25/2009
20
10,000
Report Generation Date: 8/31/2016
10/1/1995
10/1/1995
8/23/2013
12/25/2009
Page 80
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 275
105 BROADWATER AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 259-7361
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-08063
Last Inspected On: 6/3/2014
Operating Permit Renewal Date: 11/6/2017
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Lisa Pedersen, UST Class A Operator
Lisa Pedersen, UST Class B Operator
Travis Struckman, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
3043
Currently in Use
Gasoline
21
7/13/1995
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor, Manual Interstitial
Monitor
Ball Float Valve
Yes
Galvanic
Yes
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor, Manual Interstitial
Monitor
Ball Float Valve
Yes
Galvanic
Yes
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor, Manual Interstitial
Monitor
Ball Float Valve
Yes
Galvanic
Yes
5/23/2012
8,000
6
3044
Currently in Use
Gasoline
TLS-350/Gilbarco EMC , Veeder Root
21
7/13/1995
5/23/2012
8,000
7
3045
Currently in Use
Gasoline
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
21
8,000
Report Generation Date: 8/31/2016
7/13/1995
5/23/2012
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Page 81
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 275
105 BROADWATER AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 259-7361
Sys Fac ID: 56-08063
Last Inspected On: 6/3/2014
Operating Permit Renewal Date: 11/6/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
3046
Currently in Use
Gasoline
21
7/13/1995
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor, Manual Interstitial
Monitor
Ball Float Valve
Yes
Galvanic
Yes
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Continuous Interstitial Monitor, Manual Interstitial
Monitor
Ball Float Valve
Yes
Galvanic
5/23/2012
8,000
9
3047
Currently in Use
Diesel
TLS-350/Gilbarco EMC , Veeder Root
21
8,000
Report Generation Date: 8/31/2016
7/13/1995
5/23/2012
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Page 82
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 54
151 ROSEBUD LN
BILLINGS, MT 59101
YELLOWSTONE
Ian Johnstone, (406) 259-5426
Owners/Operators: CHS Inc - Spokane Valley, Owner
Sys Fac ID: 56-08208
Last Inspected On: 6/24/2015
Operating Permit Renewal Date: 6/25/2018
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Pete Nussbaum, UST Class A Operator
Tom Savas, UST Class A Operator
Chuck Crane, UST Class B Operator
Nicholas Merritt, UST Class B Operator
Karina Serrano, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
7
01
9/1/2014
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
11/1/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor
2/13/2015
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Manual Interstitial Monitor
TLS-450 , Veeder Root
High Level Alarm,
Auto Limiter
Yes
Not Applicable
9/1/2014
Fiberglass Reinforced Plastic
Flexible Plastic
5526
Currently in Use
Gasoline
11/1/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor, Not Listed
8,000
2/13/2015
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Manual Interstitial Monitor
TLS-450 , Veeder Root
9/1/2014
Fiberglass Reinforced Plastic
Flexible Plastic
5527
Currently in Use
Gasoline
11/1/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor, Not Listed
17,000
2/13/2015
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Manual Interstitial Monitor
TLS-450 , Veeder Root
5525
Currently in Use
Diesel
17,000
8
9
01
01
Report Generation Date: 8/31/2016
Not Listed
High Level Alarm,
Auto Limiter
Yes
Not Applicable
Not Listed
High Level Alarm,
Auto Limiter
Yes
Not Applicable
Not Listed
Page 83
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 54
151 ROSEBUD LN
BILLINGS, MT 59101
YELLOWSTONE
Ian Johnstone, (406) 259-5426
Sys Fac ID: 56-08208
Last Inspected On: 6/24/2015
Operating Permit Renewal Date: 6/25/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
10
01
9/1/2014
Fiberglass Reinforced Plastic
Flexible Plastic
11/1/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor, Not Listed
2/13/2015
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Manual Interstitial Monitor
TLS-450 , Veeder Root
High Level Alarm,
Auto Limiter
Yes
Not Applicable
9/1/2014
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
5529
Currently in Use
Diesel
11/1/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor, Not Listed
25,000
2/13/2015
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Manual Interstitial Monitor
TLS-450 , Veeder Root
5528
Currently in Use
Diesel
8,000
11
01
Report Generation Date: 8/31/2016
Not Listed
High Level Alarm,
Auto Limiter
Yes
Not Applicable
Not Listed
Page 84
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 58
610 WICKS LN
BILLINGS, MT 59105
(406) 259-7054
Sys Fac ID: 56-08209
Last Inspected On: 1/19/2015
Operating Permit Renewal Date: 3/17/2018
YELLOWSTONE
Owners/Operators: CHS Inc - Spokane Valley, Owner
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Sean Hurley, UST Class A Operator
Tom Savas, UST Class A Operator
Chuck Crane, UST Class B Operator
Karina Serrano, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
17
1/1/1999
Cathodically Protected Steel
Flexible Plastic
4/19/2012
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
1/1/1999
Cathodically Protected Steel
Flexible Plastic
4/19/2012
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
4256
Currently in Use
Gasoline
12,000
5
17
4257
Currently in Use
Gasoline
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
Page 85
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 58
610 WICKS LN
BILLINGS, MT 59105
(406) 259-7054
Sys Fac ID: 56-08209
Last Inspected On: 1/19/2015
Operating Permit Renewal Date: 3/17/2018
YELLOWSTONE
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
17
1/1/1999
Cathodically Protected Steel
Flexible Plastic
4/19/2012
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
4258
Currently in Use
Diesel
5,000
Report Generation Date: 8/31/2016
Page 86
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MARKET BASKET STORE
8014 S FRONTAGE RD
BILLINGS, MT 59101
YELLOWSTONE
Kebi Bowers, (406) 652-1529
Owners/Operators: Market Basket Store, Owner
Sys Fac ID: 56-08286
Last Inspected On: 4/19/2016
Operating Permit Renewal Date: 7/28/2019
(406)-656-3546
8014 S FRONTAGE RD
BILLINGS MT 59101-6202
Teresa Bidleman, UST Class A Operator
Jeff Bidleman, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
20
10/6/1995
Cathodically Protected Steel
Flexible Plastic
2/19/2016
4/1/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
10/6/1995
Cathodically Protected Steel
Flexible Plastic
2/19/2016
4/1/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
11/28/2003
Cathodically Protected Steel
Flexible Plastic
2/19/2016
4/1/2016
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Double-Walled
Pressurized
MLLD Line Tightness Testing
Continuous Interstitial Monitor
3314
Currently in Use
Gasoline
8,000
2
20
3315
Currently in Use
Gasoline
4,000
5
12
4945
Currently in Use
Diesel
8,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
Flapper Valve (Auto
Shutoff), High Level
Alarm
Yes
Galvanic
Page 87
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
PEPSI COLA BOTTLING CO BILLINGS
344 HOWARD AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 252-9355
Owners/Operators: Pepsi Cola Bottling Co Billings, Owner
Sys Fac ID: 56-08323
Last Inspected On: 10/23/2015
Operating Permit Renewal Date: 12/4/2018
(406)-252-9355
344 HOWARD AVE
BILLINGS MT 59101-3039
ERNE BRESTER, UST Class A Operator
ERNE BRESTER, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
26
8/1/1990
Cathodically Protected Steel
Steel
10/23/2015
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
OPW 1500 , OPW
none
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
1798
Currently in Use
Gasoline
3,000
Report Generation Date: 8/31/2016
Page 88
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CARDLOCK #2
36TH & 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Roger Schmechel, (406) 252-4661
Owners/Operators: GM Petroleum Dist, Owner
Sys Fac ID: 56-08324
Last Inspected On: 7/26/2013
Operating Permit Renewal Date: 12/24/2016
(406)-661-1112
City Service Valcon LLC DBA GM Petroleum Distributors,
Operator
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Roger Schmechel, UST Class A Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59101
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1179
Currently in Use
Diesel
38
5/6/1978
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Impressed Current
7/11/2011
10,000
2
1180
Currently in Use
Diesel
10/29/2010
38
7/11/2011
8,000
3
1181
Currently in Use
Gasoline
5/6/1978
10/29/2010
38
8,000
Report Generation Date: 8/31/2016
5/6/1978
7/11/2011
10/29/2010
Page 89
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BROADWATER QUICK STOP
942 BROADWATER AVE
BILLINGS, MT 59101
YELLOWSTONE
Duane Young, (406) 208-8232
Sys Fac ID: 56-08671
Last Inspected On: 9/19/2014
Operating Permit Renewal Date: 12/16/2017
Owners/Operators: Gordon Vandiviere, Operator
(406)-348-2222
Subzero Inc, Owner/Operator
(406)-208-8232
235 3RD ST N
HUNTLEY MT 59037-2714
1244 POE ST
BILLINGS MT 59105
Gordon Vandiviere, UST Class A Operator
Duane Young, UST Class A Operator
Diane Vandiviere, UST Class B Operator
Cerena Young, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
22
12/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Mechanical Line Leak Detector
Tank Tightness Testing, Stat. Inventory
Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, MLLD Line
Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
12/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
9/9/2014
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation, MLLD Line
Tightness Testing
3170
Currently in Use
Gasoline
9/9/2014
8,000
5
22
3169
Currently in Use
Gasoline
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
8,000
Report Generation Date: 8/31/2016
Page 90
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
QWEST BILLINGS WEST CENTRAL OFFICE
3190 CENTRAL AVE
BILLINGS, MT 59102
YELLOWSTONE
Kevin Robison, (801) 237-3006
Owners/Operators: Qwest Corporation, Owner
Sys Fac ID: 56-08762
Last Inspected On: 6/25/2015
Operating Permit Renewal Date: 11/13/2018
(801)-237-3006
Qwest Corporation, Operator
(801)-237-3006
250 E 200 S #1601
SALT LAKE CITY UT 84111
250 E 200 S #1601
SALT LAKE CITY UT 84111
Thomas J Pitts, UST Class A Operator
Kevin Robison, UST Class A Operator
Thomas J Pitts, UST Class B Operator
Thomas J Pitts, UST Class B Global Operator
Kevin Robison, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
1733
Currently in Use
Diesel
21
11/1/1994
Fiberglass Reinforced Plastic
Double-Walled
Auto Dialer
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-300 , Veeder Root
Flexible Plastic
Double-Walled
U.S. Suction
MLLD Line Tightness Testing
High Level Alarm
Yes
Not Applicable
1,000
Report Generation Date: 8/31/2016
8/20/2012
6/25/2015
Continuous Interstitial Monitor
Page 91
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 52
1201 CENTRAL AVE
BILLINGS, MT 59102
(406) 245-9670
Sys Fac ID: 56-08903
Last Inspected On: 3/13/2014
Operating Permit Renewal Date: 5/21/2017
YELLOWSTONE
Owners/Operators: CHS Inc - Spokane Valley, Owner
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Sean Hurley, UST Class A Operator
Pete Nussbaum, UST Class A Operator
Darcy Ziegler, UST Class B Operator
Pete Nussbaum, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
5270
Currently in Use
Gasoline
05
11/22/2010
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
High Level Alarm
Yes
Not Applicable
15,000
7
5271
Currently in Use
Diesel
05
11/22/2010
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
High Level Alarm
Yes
Not Applicable
05
11/22/2010
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
High Level Alarm
Yes
Not Applicable
7,000
8
5272
Currently in Use
Gasoline
Yes
8,000
Report Generation Date: 8/31/2016
Yes
Yes
Page 92
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 55
236 MAIN ST
BILLINGS, MT 59105
(406) 259-3240
Sys Fac ID: 56-08904
Last Inspected On: 2/27/2015
Operating Permit Renewal Date: 7/11/2018
YELLOWSTONE
Owners/Operators: CHS Inc - Spokane Valley, Owner
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Ian Johnstone, UST Class A Operator
Chuck Crane, UST Class B Operator
Darcy Ziegler, UST Class B Operator
Karina Serrano, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
589
Currently in Use
Gasoline
33
10/3/1982
10/8/2014
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
Cathodically Protected Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Impressed Current
8/1/2013
12,000
2
590
Currently in Use
Gasoline
10/13/2014
33
8/1/2013
12,000
3
591
Currently in Use
Diesel
10/3/1982
10/8/2014
10/13/2014
33
12,000
Report Generation Date: 8/31/2016
10/3/1982
10/8/2014
8/1/2013
10/13/2014
Page 93
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CARDLOCK #4
275 DANIELS ST
BILLINGS, MT 59101
YELLOWSTONE
Roger Schmechel, (406) 252-4661
Owners/Operators: Monad Daniels LLC, Owner
Sys Fac ID: 56-09271
Last Inspected On: 1/26/2016
Operating Permit Renewal Date: 4/20/2019
(406)-252-4661
City Service Valcon LLC DBA GM Petroleum Distributors,
Operator
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Roger Schmechel, UST Class A Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59101
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
23
1/1/1993
Fiberglass Reinforced Plastic
Flexible Plastic
10/10/2009
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff), Ball Float
Valve
Yes
Not Applicable
1/1/1993
Fiberglass Reinforced Plastic
Flexible Plastic
10/10/2009
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
4716
Currently in Use
Diesel
12,000
2
23
4717
Currently in Use
Gasoline
8,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff), Ball Float
Valve
Yes
Not Applicable
Page 94
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MDOT BILLINGS SITE
424 MOREY ST
BILLINGS, MT 59101
YELLOWSTONE
Joe Radonich, (406) 444-9204
Owners/Operators: MDOT Helena, Owner
Sys Fac ID: 56-09501
Last Inspected On: 1/13/2014
Operating Permit Renewal Date: 4/25/2017
(406)-444-6200
Joseph J Radonich, Operator
(406)-444-9204
KIM JANZEN
PO BOX 201001
HELENA MT 59620-1001
MDT
DEADHEAD
HELENA MT 59620-0901
Jeff Gleason, UST Class A Operator
Walt Kerttula, UST Class A Operator
Mike Murolo, UST Class A Operator
Joe Radonich, UST Class A Operator
Charlie Eddlemon, UST Class B Operator
Ronald Joslyn, UST Class B Operator
John McCloskey, UST Class B Operator
Joe Radonich, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
22
9/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1/13/2014
None
Not Required
Automatic Tank Gauging 0.2
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
9/1/1993
Cathodically Protected Steel
Fiberglass Reinforced Plastic
1/13/2014
None
Not Required
Automatic Tank Gauging 0.2
None
Safe Suction
Deferred
2948
Currently in Use
Gasoline
10,000
2
22
2949
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 95
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 280
1020 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
(406) 245-1254
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-09695
Last Inspected On: 6/25/2014
Operating Permit Renewal Date: 11/29/2017
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Stephen Reckinger, UST Class A Operator
Kimberly Robers, UST Class B Operator
Linda French, UST Class B Global Operator
Travis Struckman, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3048
Currently in Use
Gasoline
29
4/1/1987
10/3/2013
6/25/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
none
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Impressed Current
Yes
3/12/2014
TLS-350/Gilbarco EMC , Veeder Root
4/1/1987
10/3/2013
6/25/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
none
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Impressed Current
Yes
11/27/2013
TLS-350/Gilbarco EMC , Veeder Root
4/1/1987
10/3/2013
6/25/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
none
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Impressed Current
Yes
6/25/2014
TLS-350/Gilbarco EMC , Veeder Root
12,000
2
3049
Currently in Use
Gasoline
29
12,000
3
3050
Currently in Use
Gasoline
29
8,000
Report Generation Date: 8/31/2016
Page 96
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 280
1020 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
(406) 245-1254
Sys Fac ID: 56-09695
Last Inspected On: 6/25/2014
Operating Permit Renewal Date: 11/29/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
3051
Currently in Use
Diesel
29
4/1/1987
10/3/2013
Steel
none
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Impressed Current
6/25/2014
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
3/14/2014
TLS-350/Gilbarco EMC , Veeder Root
8,000
Report Generation Date: 8/31/2016
Page 97
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS FIRE STATION 1
2305 8TH AVE N
BILLINGS, MT 59101
YELLOWSTONE
(406) 657-8423
Owners/Operators: City of Billings Fire Dept, Owner
Sys Fac ID: 56-09739
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/20/2018
(406)-657-8428
2305 8TH AVE N
BILLINGS MT 59101-1018
Boyd Vopel, UST Class A Operator
Boyd Vopel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
2729
Currently in Use
Gasoline
22
12/1/1993
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Copper
Secondary Containment Chase
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Copper
Secondary Containment Chase
U.S. Suction
Deferred
High Level Alarm
Yes
Galvanic
6/18/2012
517
2
2728
Currently in Use
Diesel
22
12/1/1993
6/18/2012
1,035
Report Generation Date: 8/31/2016
Page 98
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS FIRE STATION 2
501 S 28TH ST
BILLINGS, MT 59101
YELLOWSTONE
Marvin Jochems, (406) 657-8423
Owners/Operators: City of Billings Fire Dept, Owner
Sys Fac ID: 56-09740
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/20/2018
(406)-657-8428
2305 8TH AVE N
BILLINGS MT 59101-1018
Boyd Vopel, UST Class A Operator
Boyd Vopel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
26
6/12/1990
Cathodically Protected Steel
Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
none
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Cathodically Protected Steel
Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
none
Safe Suction
Deferred
3699
Currently in Use
Diesel
10/22/2014
1,000
4
26
3700
Currently in Use
Diesel
6/12/1990
10/22/2014
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
1,000
Report Generation Date: 8/31/2016
Page 99
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS FIRE STATION 3
1928 17TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Marvin Jochems, (406) 657-8423
Owners/Operators: City of Billings Fire Dept, Owner
Sys Fac ID: 56-09741
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/20/2018
(406)-657-8428
2305 8TH AVE N
BILLINGS MT 59101-1018
Boyd Vopel, UST Class A Operator
Boyd Vopel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
4297
Currently in Use
Diesel
500
24
3/1/1992
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Fiberglass Reinforced Plastic
None
Safe Suction
Not Listed
High Level Alarm
Yes
Galvanic
Report Generation Date: 8/31/2016
6/18/2012
Page 100
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS FIRE STATION 5
605 S 24TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Marvin L Jochems, (406) 657-8423
Owners/Operators: City of Billings Fire Dept, Owner
Sys Fac ID: 56-09742
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/20/2018
(406)-657-8428
2305 8TH AVE N
BILLINGS MT 59101-1018
Boyd Vopel, UST Class A Operator
Boyd Vopel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
2731
Currently in Use
Gasoline
23
1/1/1993
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Fiberglass Reinforced Plastic
None
Safe Suction
Deferred
High Level Alarm
Yes
Galvanic
6/18/2012
517
5
2732
Currently in Use
Diesel
23
1/1/1993
6/18/2012
517
Report Generation Date: 8/31/2016
Page 101
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS FIRE STATION 6
1601 ST ANDREWS DR
BILLINGS, MT 59105
YELLOWSTONE
Marvin Jochems, (406) 657-8423
Owners/Operators: City of Billings Fire Dept, Owner
Sys Fac ID: 56-09743
Last Inspected On: 11/3/2014
Operating Permit Renewal Date: 2/20/2018
(406)-657-8428
2305 8TH AVE N
BILLINGS MT 59101-1018
Boyd Vopel, UST Class A Operator
Boyd Vopel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
28
10/19/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
2733
Currently in Use
Diesel
6/18/2012
500
Report Generation Date: 8/31/2016
Page 102
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS REGIONAL LANDFILL
5240 JELLISON RD
BILLINGS, MT 59101
YELLOWSTONE
Barbara Butler, (406) 657-8260
Owners/Operators: CITY OF BILLINGS SOLID WASTE DIVISION,
Owner/Operator
Clarence Kostenko, UST Class A Operator
Anthony Lehner, UST Class A Operator
Tony Lehner, UST Class A Operator
Anthony Lehner, UST Class B Operator
Tony Lehner, UST Class B Operator
Clarence Kostenko, UST Class B Global Operator
Sys Fac ID: 56-09744
Last Inspected On: 6/25/2015
Operating Permit Renewal Date: 9/4/2018
(406)-657-8240
PO BOX 1178
BILLINGS MT 59103
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
29
10/1/1986
Cathodically Protected Steel
Flexible Plastic
6/25/2015
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-300 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
630
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
6/25/2015
Page 103
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
PUBLIC UTILITIES DEPT
2251 BELKNAP AVE
BILLINGS, MT 59101
YELLOWSTONE
Larry Diedrich, (406) 657-8335
Owners/Operators: City of Billings Public Works, Owner
Sys Fac ID: 56-09746
Last Inspected On: 6/19/2015
Operating Permit Renewal Date: 10/29/2018
(406)-657-8335
2251 BELKNAP AVE
BILLINGS MT 59101
Lawrence Diedrich, UST Class A Operator
Lawrence Diedrich, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
26
1/1/1990
Steel Clad
Fiberglass Reinforced Plastic
6/19/2015
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
1/1/1990
Steel Clad
Fiberglass Reinforced Plastic
6/19/2015
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
None
Safe Suction
Deferred
631
Currently in Use
Gasoline
10,000
2
26
632
Currently in Use
Diesel
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 104
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS METROPOLITAN TRANSIT
1705 MONAD RD
BILLINGS, MT 59101
YELLOWSTONE
John Bishop, (406) 657-8218
Owners/Operators: City of Billings MET Transit, Owner
Sys Fac ID: 56-09747
Last Inspected On: 8/13/2015
Operating Permit Renewal Date: 12/18/2018
(406)-657-8219
PO BOX 1178
BILLINGS MT 59103-1178
John Bishop, UST Class A Operator
Rick Pirami, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
635
Currently in Use
Waste Oil
2,000
32
10/15/1983
Cathodically Protected Steel
None
Not Required
Automatic Tank Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
None
Gravity Feed
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
4
4862
Currently in Use
Diesel
12
Fiberglass Reinforced Plastic
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
8/13/2015
8/13/2015
8/13/2015
8,000
5
4863
Currently in Use
Diesel
9/3/2003
8/13/2015
12
8,000
Report Generation Date: 8/31/2016
9/3/2003
8/13/2015
8/13/2015
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Continuous Interstitial Monitor
Page 105
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 284
3226 ROSEBUD DR
BILLINGS, MT 59102
YELLOWSTONE
Barbara Sparovic, (406) 652-4095
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-09752
Last Inspected On: 3/3/2014
Operating Permit Renewal Date: 5/30/2017
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Ronald VanDenBroeke, UST Class A Operator
Garrett Lapp, UST Class B Operator
Irene Matzen, UST Class B Operator
Linda French, UST Class B Global Operator
Jack Krueger Jr, UST Class B Global Operator
Travis Struckman, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3052
Currently in Use
Gasoline
32
11/5/1983
3/3/2014
Cathodically Protected Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Impressed Current
Yes
11/24/2007
TLS-350/Gilbarco EMC , Veeder Root
11/5/1983
3/3/2014
Cathodically Protected Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Impressed Current
Yes
11/24/2007
TLS-350/Gilbarco EMC , Veeder Root
11/5/1983
3/3/2014
Cathodically Protected Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
IImpressed Current
Yes
11/24/2007
TLS-350/Gilbarco EMC , Veeder Root
10,000
2
3053
Currently in Use
Gasoline
32
10,000
3
3054
Currently in Use
Gasoline
32
6,000
Report Generation Date: 8/31/2016
Page 106
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 285
785 S 20TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Jack Krueger, (406) 656-3430
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-09753
Last Inspected On: 11/19/2014
Operating Permit Renewal Date: 1/22/2018
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Russell Ericson, UST Class B Operator
Stan Sauer, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
3055
Currently in Use
Gasoline
19
4/1/1997
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Galvanic
Yes
11/19/2014
8,000
6
3056
Currently in Use
Gasoline
19
4/1/1997
11/19/2014
8,000
7
3057
Currently in Use
Gasoline
19
4/1/1997
11/19/2014
8,000
8
3058
Currently in Use
Gasoline
19
4/1/1997
11/19/2014
8,000
Report Generation Date: 8/31/2016
Page 107
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 285
785 S 20TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Jack Krueger, (406) 656-3430
Sys Fac ID: 56-09753
Last Inspected On: 11/19/2014
Operating Permit Renewal Date: 1/22/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
9
3059
Currently in Use
Diesel
19
4/1/1997
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Galvanic
8,000
Report Generation Date: 8/31/2016
11/19/2014
10/8/2008
Page 108
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 286
405 ALKALI CREEK RD
BILLINGS, MT 59105
YELLOWSTONE
Steve Reckinger, (952) 830-8028
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-09754
Last Inspected On: 10/28/2013
Operating Permit Renewal Date:
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3060
Temporarily Out of Use
Gasoline
32
6/1/1984
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Stat. Inventory Reconcilitation
Steel
None
Pressurized
Automatic Tank Gauging 0.2, Stat. Inventory
Reconcilitation
Ball Float Valve
Yes
Impressed Current
Bare Steel
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Stat. Inventory Reconcilitation
Steel
None
Pressurized
Automatic Tank Gauging 0.2, Stat. Inventory
Reconcilitation
Ball Float Valve
Yes
Impressed Current
10/28/2013
10,000
2
3061
Temporarily Out of Use
Gasoline
9/13/2007
32
10,000
Report Generation Date: 8/31/2016
6/1/1984
10/28/2013
9/13/2007
Page 109
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DEEDLES
3189 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Paul DiLorenzo, (406) 591-1921
Owners/Operators: Stockton Oil Company, Owner
Sys Fac ID: 56-10075
Last Inspected On: 12/31/2013
Operating Permit Renewal Date: 3/15/2017
(406)-245-6376
Paul J DiLorenzo, Operator
(406)-839-2399
PO BOX 1756
BILLINGS MT 59103-1756
3189 KING AVE WEST
BILLINGS MT 59102-7466
Paul J DiLorenzo, UST Class A Operator
Mykel Stockton, UST Class A Operator
Christopher Stockton, UST Class B Global Operator
Joseph Stockton, UST Class B Global Operator
Mykel Stockton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
29
1/13/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
12/31/2013
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
1/13/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
12/31/2013
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
1/13/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
12/31/2013
None
Mechanical Line Leak Detector
Stat. Inventory Reconcilitation
None
Pressurized
Stat. Inventory Reconcilitation
3834
Currently in Use
Gasoline
8,000
2
29
3835
Currently in Use
Gasoline
6,000
3
29
3836
Currently in Use
Gasoline
6,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 110
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SKYVIEW HIGH SCHOOL DIST 2
1775 HIGH SIERRA BLVD
BILLINGS, MT 59105
YELLOWSTONE
Jim Miller, (406) 281-5200
Owners/Operators: Billings School District, Owner
Sys Fac ID: 56-10585
Last Inspected On: 2/3/2016
Operating Permit Renewal Date: 6/22/2019
(406)-247-3777
415 N 30TH ST
BILLINGS MT 59101-1298
Dennis Stellingwerf, UST Class A Operator
Jim Miller, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
29
3/16/1987
Cathodically Protected Steel
Flexible Plastic
2/3/2016
None
Auto Dialer
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-300 , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
448
Currently in Use
Heating Oil
5,000
Report Generation Date: 8/31/2016
2/3/2016
Page 111
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
3 GS CONVENIENCE CENTER 27TH ST
702 S 27TH ST
BILLINGS, MT 59101
YELLOWSTONE
Larry Grosulak, (406) 256-6246
Owners/Operators: SNG Inc 3, Owner
Sys Fac ID: 56-10797
Last Inspected On: 9/30/2014
Operating Permit Renewal Date: 1/7/2018
(406)-245-0161
4410 STATE AVE
BILLINGS MT 59101-5060
KELLY GROSLACK, UST Class A Operator
Larry Groslack, UST Class A Operator
TAMI MAUCH, UST Class A Operator
KELLY GROSLACK, UST Class B Operator
Larry Groslack, UST Class B Operator
TAMI MAUCH, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
18
7/1/1998
Cathodically Protected Steel
Flexible Plastic
12/19/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor
7/18/2008
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-300 , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
7/1/1998
Cathodically Protected Steel
Flexible Plastic
4752
Currently in Use
Gasoline
12/19/2014
Double-Walled
Pressurized
Continuous Interstitial Monitor
4,000
7/18/2008
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-300 , Veeder Root
4751
Currently in Use
Gasoline
8,000
5
18
Report Generation Date: 8/31/2016
Automatic Tank Gauging 0.2
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Automatic Tank Gauging 0.2, MLLD Line
Tightness Testing
Page 112
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
GAS N GO
800 JACKSON ST
BILLINGS, MT 59101
YELLOWSTONE
Connie Pelican, (406) 656-5882
Owners/Operators: TLC Enterprises Inc, Owner
Sys Fac ID: 56-10866
Last Inspected On: 10/28/2013
Operating Permit Renewal Date: 1/4/2017
(406)-245-1133
Gas N Go, Operator
(406)-245-1133
122 1ST AVE S
LAUREL MT 59044
800 JACKSON STREET
BILLINGS MT 59101
Renee Andrews, UST Class A Operator
Connie Pelican, UST Class A Operator
Renee Andrews, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
32
4/10/1984
Cathodically Protected Steel
Steel
9/1/2008
10/28/2013
Lined Interior/Impressed Current
Not Required
Stat. Inventory Reconcilitation
None
Safe Suction
Not Listed
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
4551
Currently in Use
Gasoline
6,000
Report Generation Date: 8/31/2016
Page 113
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
EXXON MARKETING BILLINGS TERMINAL
607 EXXONMOBIL RD
BILLINGS, MT 59101
YELLOWSTONE
Kris Gagnon, (406) 657-5400
Owners/Operators: Exxon Company USA Billings, Owner
Sys Fac ID: 56-11335
Last Inspected On: 2/12/2016
Operating Permit Renewal Date: 5/12/2019
(406)-657-5404
TERMINAL SUPERVISOR
607 EXXONMOBIL RD
BILLINGS MT 59101-7363
Michael T Bailey, UST Class A Operator
Charles Herre, UST Class A Operator
Alan Mizner, UST Class A Operator
James Vokral Sup, UST Class A Operator
Christopher Scott Martin, UST Class B Operator
Alan Mizner, UST Class B Operator
Michael T Bailey, UST Class B Global Operator
Charles Herre, UST Class B Global Operator
Marc Larson, UST Class B Global Operator
James Vokral Sup, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
1
Currently in Use
Oil/Water Separator
4,000
2
2736
Currently in Use
Mixture
3,000
21
4
2738
Currently in Use
66
Yes
Report Generation Date: 8/31/2016
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Bare Steel
None
10/3/2008
11/10/2009
Deferred
Steel
none
Not Listed
Deferred
10/1/1994
Steel Clad
Double-Walled
Not Required
Continuous Interstitial Monitor
Steel
None
Gravity Feed
Not Listed
Unknown
Impressed Current
Not Required
Steel - Terminal Piping
None
Pressurized
Deferred
MLLD Line Tightness Testing
12/5/2015
11/22/2015
Gasoline
197,000
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
1/1/1950
12/5/2015
11/17/2015
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
Yes
High Level Alarm
Yes
Impressed Current
Yes
Not Applicable,
Impressed Current
Page 114
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
EXXON MARKETING BILLINGS TERMINAL
607 EXXONMOBIL RD
BILLINGS, MT 59101
YELLOWSTONE
Kris Gagnon, (406) 657-5400
Sys Fac ID: 56-11335
Last Inspected On: 2/12/2016
Operating Permit Renewal Date: 5/12/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
6
2740
Currently in Use
66
Yes
1/1/1950
Unknown
Impressed Current
Not Required
Steel - Terminal Piping
None
Pressurized
12/5/2015
11/17/2015
Deferred
MLLD Line Tightness Testing
1/1/1950
Unknown
Impressed Current
Not Required
Steel - Terminal Piping
None
Pressurized
12/5/2015
11/22/2015
Deferred
MLLD Line Tightness Testing
1/1/1950
Unknown
Impressed Current
Not Required
Steel - Terminal Piping
None
Pressurized
12/5/2015
11/22/2015
Deferred
MLLD Line Tightness Testing
1/1/1952
Unknown
Impressed Current
Continuous Interstitial Monitoring
Steel - Terminal Piping
None
Pressurized
12/5/2015
11/17/2015
Deferred
MLLD Line Tightness Testing
1/1/1952
Unknown
Impressed Current
Continuous Interstitial Monitoring
Steel - Terminal Piping
None
Pressurized
Deferred
MLLD Line Tightness Testing
Diesel
60,000
15
2749
Currently in Use
66
Yes
Diesel
60,000
16
2750
Currently in Use
66
Yes
Gasoline
60,000
36
2764
Currently in Use
64
Yes
Gasoline
2,959,110
37
2765
Currently in Use
64
Yes
Diesel
1,784,454
Report Generation Date: 8/31/2016
12/5/2015
11/17/2015
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
Yes
Not Applicable,
Impressed Current
Yes
Not Applicable,
Impressed Current
Yes
Not Applicable,
Impressed Current
Yes
Not Applicable,
Impressed Current
Yes
Not Applicable,
Impressed Current
Page 115
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
EXXON MARKETING BILLINGS TERMINAL
607 EXXONMOBIL RD
BILLINGS, MT 59101
YELLOWSTONE
Kris Gagnon, (406) 657-5400
Sys Fac ID: 56-11335
Last Inspected On: 2/12/2016
Operating Permit Renewal Date: 5/12/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
38
2766
Currently in Use
64
Yes
1/1/1952
Unknown
Impressed Current
Continuous Interstitial Monitoring
Steel - Terminal Piping
None
Pressurized
12/5/2015
11/17/2015
Deferred
MLLD Line Tightness Testing
5/1/1997
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
Diesel
1,749,888
39
2758
Currently in Use
Hazardous Substance
15,000
19
Yes
40
2759
Currently in Use
Hazardous Substance
15,000
19
Yes
41
2760
Currently in Use
Hazardous Substance
15,000
19
Yes
42
2761
Currently in Use
Hazardous Substance
15,000
19
Yes
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
Report Generation Date: 8/31/2016
5/1/1997
10/3/2008
11/10/2009
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
Yes
Not Applicable,
Impressed Current
Page 116
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
EXXON MARKETING BILLINGS TERMINAL
607 EXXONMOBIL RD
BILLINGS, MT 59101
YELLOWSTONE
Kris Gagnon, (406) 657-5400
Sys Fac ID: 56-11335
Last Inspected On: 2/12/2016
Operating Permit Renewal Date: 5/12/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
43
2762
Currently in Use
Hazardous Substance
15,000
19
Yes
5/1/1997
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
44
2751
Currently in Use
Hazardous Substance
15,000
19
Yes
Unknown
None
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
MLLD Line Tightness Testing
Yes
Not Applicable
45
2752
Currently in Use
Hazardous Substance
6,000
19
Yes
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
46
2753
Currently in Use
Hazardous Substance
6,000
19
Yes
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
47
2754
Currently in Use
Hazardous Substance
6,000
19
Yes
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
Report Generation Date: 8/31/2016
5/1/1997
10/3/2008
11/10/2009
Page 117
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
EXXON MARKETING BILLINGS TERMINAL
607 EXXONMOBIL RD
BILLINGS, MT 59101
YELLOWSTONE
Kris Gagnon, (406) 657-5400
Sys Fac ID: 56-11335
Last Inspected On: 2/12/2016
Operating Permit Renewal Date: 5/12/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
48
2755
Currently in Use
Hazardous Substance
6,000
19
Yes
5/1/1997
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
49
2756
Currently in Use
Hazardous Substance
6,000
19
Yes
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
50
2763
Currently in Use
Hazardous Substance
6,000
19
Yes
Unknown
Impressed Current
Continuous Interstitial Monitoring
Deferred
Steel
None
Pressurized
Not Listed
Yes
Not Applicable
10/3/2008
11/10/2009
5/1/1997
10/3/2008
11/10/2009
Report Generation Date: 8/31/2016
5/1/1997
10/3/2008
11/10/2009
Page 118
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FLYING J INC BILLINGS
2775 OLD HARDIN RD
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: Montana Innovations LLC, Owner
Sys Fac ID: 56-12585
Last Inspected On: 2/2/2015
Operating Permit Renewal Date: 2/13/2018
(406)-497-6700
PO BOX 6000
BUTTE MT 59702-6000
Trent Biggers, UST Class A Operator
Trent Biggers, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
25
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
1109
Currently in Use
Diesel
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
20,000
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
1108
Currently in Use
Diesel
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
20,000
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
1105
Currently in Use
Gasoline
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
12,000
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
2
3
25
25
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Page 119
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FLYING J INC BILLINGS
2775 OLD HARDIN RD
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-12585
Last Inspected On: 2/2/2015
Operating Permit Renewal Date: 2/13/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
25
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
1110
Currently in Use
Diesel
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
20,000
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
8/1/1991
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
4448
Currently in Use
Gasoline
11/29/2012
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
12,000
6/26/2007
None
Electronic Line Leak Detector
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
8/1/2013
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
10/4/2013
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Not Listed
4447
Currently in Use
Gasoline
12,000
5
6
7
25
25
03
5425
Currently in Use
Diesel
6,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Page 120
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FLYING J INC BILLINGS
2775 OLD HARDIN RD
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-12585
Last Inspected On: 2/2/2015
Operating Permit Renewal Date: 2/13/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
9
03
8/1/2013
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
10/4/2013
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Not Listed
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
5427
Currently in Use
Diesel
6,000
Report Generation Date: 8/31/2016
Yes
Page 121
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
ZIP TRIP 53
2975 GRAND AVE
BILLINGS, MT 59102
(406) 655-0871
Sys Fac ID: 56-13245
Last Inspected On: 2/23/2015
Operating Permit Renewal Date: 7/14/2018
YELLOWSTONE
Owners/Operators: CHS Inc - Spokane Valley, Owner
(509)-535-7701
Cenex Zip Trip, Operator
(509)-535-7701
16124 E MARIETTA LANE
SPOKANE WA 99213
16124 E MARIETTA LANE
SPOKANE VALLEY WA 99216
Ian Johnstone, UST Class A Operator
Nicholas Merritt, UST Class B Operator
Darcy Ziegler, UST Class B Operator
Karina Serrano, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
594
Currently in Use
Diesel
22
9/1/1993
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Ball Float Valve
Yes
Galvanic
2/23/2015
12,000
2
592
Currently in Use
Gasoline
22
9/1/1993
2/23/2015
12,000
3
593
Currently in Use
Gasoline
22
12,000
Report Generation Date: 8/31/2016
9/1/1993
2/23/2015
Page 122
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 87
4041 GRAND AVE
BILLINGS, MT 59106
YELLOWSTONE
Paul Courchaine, (406) 651-9353
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-13723
Last Inspected On: 8/19/2016
Operating Permit Renewal Date: 11/20/2019
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
David Kujath, UST Class A Operator
Stephen Reckinger, UST Class A Operator
Paul Courchaine, UST Class B Operator
Greg Hoffman, UST Class B Operator
Garrett Lapp, UST Class B Operator
Linda French, UST Class B Global Operator
David Kujath, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3062
Currently in Use
Gasoline
20
6/1/1996
6/1/2006
7/11/2013
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Impressed Current
Yes
6/21/2013
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
6/1/1996
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Impressed Current
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Impressed Current
Yes
8,000
2
3063
Currently in Use
Gasoline
20
6/1/2006
7/11/2013
8,000
3
3064
Currently in Use
Gasoline
6/21/2013
20
8,000
Report Generation Date: 8/31/2016
6/1/1996
6/1/2006
7/11/2013
6/21/2013
Page 123
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 87
4041 GRAND AVE
BILLINGS, MT 59106
YELLOWSTONE
Paul Courchaine, (406) 651-9353
Sys Fac ID: 56-13723
Last Inspected On: 8/19/2016
Operating Permit Renewal Date: 11/20/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
3065
Currently in Use
Gasoline
20
6/1/1996
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Impressed Current
Yes
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
Ball Float Valve
Yes
Impressed Current
6/1/2006
7/11/2013
8,000
5
3066
Currently in Use
Diesel
6/21/2013
20
8,000
Report Generation Date: 8/31/2016
6/1/1996
6/1/2006
7/11/2013
6/21/2013
Page 124
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN AND COUNTRY HILL TOP
523 HILLTOP RD
BILLINGS, MT 59105
YELLOWSTONE
Wes Burley, (406) 256-1020
Owners/Operators: Town & Country Supply Association, Owner
Sys Fac ID: 56-13731
Last Inspected On: 10/30/2013
Operating Permit Renewal Date: 12/12/2016
(406)-628-6314
PO BOX 367
LAUREL MT 59044-0367
Lucy Green, UST Class A Operator
Mark Heimbichner, UST Class A Operator
Leilani McCarthy, UST Class A Operator
Steven Shelton, UST Class A Operator
Leilani McCarthy, UST Class B Operator
Mark Heimbichner, UST Class B Global Operator
Steven Shelton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3419
Currently in Use
Gasoline
20
7/1/1996
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
6/30/2014
6/30/2014
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Not Applicable
7/14/2014
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor, Not Listed
10/30/2013
10,000
2
3420
Currently in Use
Gasoline
12/3/2010
20
10/30/2013
10,000
3
5509
Currently in Use
Gasoline
7/1/1996
12/3/2010
02
4,000
Report Generation Date: 8/31/2016
Page 125
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP BILLINGS #8
3969 GRAND AVE
BILLINGS, MT 59102
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: Townhouse Inns of Conrad, Owner
Sys Fac ID: 56-13741
Last Inspected On: 9/29/2014
Operating Permit Renewal Date: 2/7/2018
(406)-497-6700
Town Pump Inc, Operator
(406)-497-6700
PO BOX 6000
BUTTE MT 59702
PO BOX 6000
BUTTE MT 59702-2534
Charles A Armstrong, UST Class A Operator
Charles A Armstrong, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
19
9/1/1996
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation
2013
Currently in Use
Gasoline
10,000
2
12/22/2011
19
2014
Currently in Use
Gasoline
20,000
3
12/22/2011
19
2015
Currently in Use
Diesel
10,000
4
9/1/1996
9/1/1996
12/22/2011
19
2016
Currently in Use
Diesel
4,000
Report Generation Date: 8/31/2016
9/1/1996
12/22/2011
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Page 126
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP BILLINGS #8
3969 GRAND AVE
BILLINGS, MT 59102
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-13741
Last Inspected On: 9/29/2014
Operating Permit Renewal Date: 2/7/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
19
9/1/1996
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
2017
Currently in Use
Diesel
4,000
Report Generation Date: 8/31/2016
12/22/2011
Page 127
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FIRST INTERSTATE BANK UST
401 N 31ST ST
BILLINGS, MT 59101
YELLOWSTONE
Jermone Ries, (406) 255-7100
Owners/Operators: Billings 401 LLC, Owner
Sys Fac ID: 56-13766
Last Inspected On: 1/15/2016
Operating Permit Renewal Date: 6/1/2019
(406)-255-7100
PO BOX 7047
BILLINGS MT 59103-7047
Jerome Ries, UST Class A Operator
Ricky Coop, UST Class B Operator
Patrick Kelly, UST Class B Operator
Leonard Meyer, UST Class B Operator
Jerome Ries, UST Class B Operator
Dennis Tallant, UST Class B Operator
Brad Zimmer, UST Class B Operator
Jim Zimmer, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
17
10/1/1998
Steel Clad
Flexible Plastic
1/15/2016
Double-Walled
Not Required
Manual Interstitial Monitor
Double-Walled
U.S. Suction
Manual Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
3400
Currently in Use
Diesel
560
Report Generation Date: 8/31/2016
1/16/2013
Page 128
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
AMERICA FAMILY RESTAURANT AND LOUNGE
4910 SOUTHGATE DR
BILLINGS, MT 59101
YELLOWSTONE
John Williamson, (406) 254-2510
Sys Fac ID: 56-13781
Last Inspected On: 3/14/2014
Operating Permit Renewal Date: 5/22/2017
Owners/Operators: America Foods Inc, Owner
(406)-672-6151
John Williamson, Operator
(406)-254-2510
745 HENESTA PLACE
BILLINGS MT 59102
4910 SOUTHGATE DR
BILLINGS MT 59101-4667
John Williamson, UST Class A Operator
John Williamson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
19
5/1/1997
Cathodically Protected Steel
Steel
5/1/2007
3/14/2014
None
Not Required
Manual Tank Gauging
none
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
3429
Temporarily Out of Use
Gasoline
500
Report Generation Date: 8/31/2016
Page 129
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONOMART SUPERSTORE 7
4903 SOUTHGATE DR
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-13808
Last Inspected On: 7/26/2013
Operating Permit Renewal Date: 12/31/2016
Owners/Operators: C Store Properties LLC, Owner
(406)-651-5101
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Laura Geffre, UST Class B Operator
Kerry Schmelzer, UST Class B Operator
Ron Tenney, UST Class B Operator
Tammie Turner, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1182
Currently in Use
Gasoline
18
12/5/1997
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
5/29/2013
10,000
2
1183
Currently in Use
Gasoline
18
12/5/1997
5/29/2013
10,000
Report Generation Date: 8/31/2016
Page 130
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
CONOMART SUPERSTORE 7
4903 SOUTHGATE DR
BILLINGS, MT 59101
YELLOWSTONE
Dennis Whitmore, (406) 252-4661
Sys Fac ID: 56-13808
Last Inspected On: 7/26/2013
Operating Permit Renewal Date: 12/31/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
1184
Currently in Use
Diesel
17
12/5/1998
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
5/29/2013
8,000
Report Generation Date: 8/31/2016
Page 131
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
THE WAVE CAR WASH
858 S 29TH ST W
BILLINGS, MT 59102
YELLOWSTONE
Steve Ott, (406) 656-2781
Owners/Operators: Ste Ott, Owner
Sys Fac ID: 56-13884
Last Inspected On: 7/6/2016
Operating Permit Renewal Date: 9/13/2019
(406)-656-2781
858 S 29TH ST W
BILLINGS MT 59102-7449
Stacy Ott, UST Class A Operator
Steven Ott, UST Class A Operator
Jessica Mascarena, UST Class B Operator
Stacy Ott, UST Class B Operator
Mark Roth, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
3527
Currently in Use
Gasoline
18
6/1/1998
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
High Level Alarm
Yes
Galvanic
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
High Level Alarm
Yes
Galvanic
6/10/2013
12,000
2
3528
Currently in Use
Gasoline
TLS-350/Gilbarco EMC , Veeder Root
18
12,000
Report Generation Date: 8/31/2016
6/1/1998
6/10/2013
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Page 132
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
COSTCO WHOLESALE GASOLINE 69
2290 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Dennis Bock, (425) 313-8100
Owners/Operators: Costco Wholesale, Owner
Sys Fac ID: 56-13953
Last Inspected On: 1/22/2016
Operating Permit Renewal Date: 4/1/2019
(425)-313-8100
ATTN: LICENSING
PO BOX 35005
SEATTLE WA 98124-8990
Dennis Bock, UST Class A Operator
Michael Clough, UST Class A Operator
Richard Colgrove, UST Class A Operator
Andrew Jurcich, UST Class A Operator
Arthur Kraft, UST Class A Operator
Dan Martinez, UST Class A Operator
Joel Osborne, UST Class A Operator
Samuel Rodriguez, UST Class A Operator
Michael Schaeffer, UST Class A Operator
Andrew Jurcich, UST Class B Operator
Arthur Kraft, UST Class B Operator
Joel Osborne, UST Class B Operator
Hal Ostlund, UST Class B Operator
Brett G Smith, UST Class B Operator
Dennis Bock, UST Class B Global Operator
Michael Clough, UST Class B Global Operator
Samuel Rodriguez, UST Class B Global Operator
Michael Schaeffer, UST Class B Global Operator
Mark Shellabarger, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4109
Currently in Use
Gasoline
16
10/1/1999
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing, Approved Remote Monitoring
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
30,000
Report Generation Date: 8/31/2016
11/19/2015
Page 133
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
COSTCO WHOLESALE GASOLINE 69
2290 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Dennis Bock, (425) 313-8100
Sys Fac ID: 56-13953
Last Inspected On: 1/22/2016
Operating Permit Renewal Date: 4/1/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
4110
Currently in Use
Gasoline
16
10/1/1999
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing, Approved Remote Monitoring
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing, Approved Remote Monitoring
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Concrete
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor, Deferred
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing, Approved Remote
Monitoring
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
15,000
3
4111
Currently in Use
Diesel
11/19/2015
16
15,000
4
5354
Currently in Use
Hazardous Substance
10/1/1999
11/19/2015
05
Yes
1,200
Report Generation Date: 8/31/2016
4/1/2011
11/19/2015
Yes
Page 134
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
WELLS FARGO CENTER
175 N 27TH ST
BILLINGS, MT 59101
YELLOWSTONE
Robert Slayton, (406) 245-2748
Owners/Operators: S F H II LLC, Owner
Sys Fac ID: 56-13972
Last Inspected On: 3/27/2014
Operating Permit Renewal Date: 8/20/2017
(406)-651-0603
PO BOX 1942
BILLINGS MT 59103-1942
John Schafnitz, UST Class A Operator
John Schafnitz, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
15
11/1/2000
Cathodically Protected Steel
Copper
Double-Walled
Not Required
Continuous Interstitial Monitor
LDE Series , Pneumercator
Secondary Containment Chase
Safe Suction
Not Listed
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
4231
Currently in Use
Diesel
400
Report Generation Date: 8/31/2016
3/27/2014
Page 135
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
WELLS FARGO BANK OPERATIONS CENTER
2324 OVERLAND AVE
BILLINGS, MT 59102
YELLOWSTONE
Barr Stan, (406) 690-6680
Owners/Operators: Wells Fargo Bank Billings Operations Center, Owner
Sys Fac ID: 56-13992
Last Inspected On: 5/19/2014
Operating Permit Renewal Date: 8/19/2017
(406)-655-7390
2324 OVERLAND AVE
BILLINGS MT 59102-6401
Greg Amos, UST Class A Operator
Stan Barr Jr, UST Class A Operator
Richard Brodston, UST Class A Operator
Greg Amos, UST Class B Operator
Stan Barr Jr, UST Class B Operator
Richard Brodston, UST Class B Operator
Stan Barr Jr, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4279
Currently in Use
Diesel
15
9/1/2000
9/10/2014
Steel Clad
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Steel Clad
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
5/30/2008
8,000
2
4280
Currently in Use
Diesel
15
8,000
Report Generation Date: 8/31/2016
9/1/2000
9/10/2014
5/30/2008
Page 136
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 108
790 S BILLINGS BLVD
BILLINGS, MT 59101
YELLOWSTONE
Jack Krueger, (406) 860-9083
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 56-13994
Last Inspected On: 12/3/2013
Operating Permit Renewal Date: 2/4/2017
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Stephen Reckinger, UST Class A Operator
Jeff Reed, UST Class B Operator
Linda French, UST Class B Global Operator
Jack Krueger Jr, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4285
Currently in Use
Diesel
15
5/1/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
6/19/2010
TLS-350/Gilbarco EMC , Veeder Root
5/4/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
6/29/2010
TLS-350/Gilbarco EMC , Veeder Root
5/1/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
7/25/2010
TLS-350/Gilbarco EMC , Veeder Root
10,000
2
4286
Currently in Use
Gasoline
15
10,000
3
4287
Currently in Use
Gasoline
15
10,000
Report Generation Date: 8/31/2016
Page 137
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 108
790 S BILLINGS BLVD
BILLINGS, MT 59101
YELLOWSTONE
Jack Krueger, (406) 860-9083
Sys Fac ID: 56-13994
Last Inspected On: 12/3/2013
Operating Permit Renewal Date: 2/4/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
4288
Currently in Use
Gasoline
20,000
15
5/1/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Stat. Inventory Reconcilitation
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
Ball Float Valve
Yes
Not Applicable
Yes
Report Generation Date: 8/31/2016
6/22/2009
Page 138
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
JTL GROUP INC UST
1102 SHILOH RD
BILLINGS, MT 59106
YELLOWSTONE
Patrick Schneider, (406) 322-2012
Owners/Operators: JTL Group Inc, Owner
Sys Fac ID: 56-14001
Last Inspected On: 6/6/2016
Operating Permit Renewal Date: 10/23/2019
(406)-655-2012
PO BOX 80066
BILLINGS MT 59108-0066
Dan Ottman, UST Class A Operator
Dan Ottman, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4397
Currently in Use
Gasoline
1,958
15
4/1/2001
Steel Clad
Double-Walled
Not Required
Automatic Tank Gauging 0.2
TLS-300 , Veeder Root
Fiberglass Reinforced Plastic
None
Safe Suction
Deferred
High Level Alarm
Yes
Not Applicable
2
4398
Currently in Use
Diesel
15
4/1/2001
Steel Clad
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
13,019
Report Generation Date: 8/31/2016
TLS-300 , Veeder Root
Page 139
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS SENIOR HIGH SCHOOL
425 GRAND AVE
BILLINGS, MT 59101
YELLOWSTONE
(406) 247-2100
Owners/Operators: Billings School District, Owner
Sys Fac ID: 56-14045
Last Inspected On: 2/4/2016
Operating Permit Renewal Date:
(406)-247-3777
415 N 30TH ST
BILLINGS MT 59101-1298
Dennis Stellingwerf, UST Class A Operator
Rodney Grotbo, UST Class B Operator
Bruce Schliticing, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
14
12/17/2001
Cathodically Protected Steel
Flexible Plastic
10/27/2012
Double-Walled
Auto Dialer
Continuous Interstitial Monitor
ILS-350 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
4601
Temporarily Out of Use
Diesel
3,000
Report Generation Date: 8/31/2016
2/3/2016
Page 140
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
LEWIS AND CLARK MIDDLE SCHOOL
1315 LEWIS AVE
BILLINGS, MT 59102
YELLOWSTONE
Richard Whitney, (406) 255-3778
Owners/Operators: Lewis and Clark Middle School, Owner
Sys Fac ID: 56-14070
Last Inspected On: 11/22/2013
Operating Permit Renewal Date: 3/30/2017
(406)-255-3778
1315 LEWIS AVE
BILLINGS MT 59102-4237
Dennis Stellingwerf, UST Class A Operator
Fred Gleich, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
11
11/15/2004
Cathodically Protected Steel
Flexible Plastic
8/24/2012
Double-Walled
Continuous Interstitial Monitoring
Continuous Interstitial Monitor
Double-Walled
Pressurized
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
4970
Currently in Use
Heating Oil
2,000
Report Generation Date: 8/31/2016
11/22/2013
Page 141
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MIDWEST MOTOR EXPRESS INC
214 ORCHARD LN
BILLINGS, MT 59101
YELLOWSTONE
Chris Booth, (406) 245-5938
Owners/Operators: Midwest Motor Express, Owner
Sys Fac ID: 56-14075
Last Inspected On: 11/17/2014
Operating Permit Renewal Date: 2/3/2018
(406)-245-5938
Chris Booth, Operator
(406)-245-5938
220 ORCHARD LN
BILLINGS MT 59101-4952
214 ORCHARD LANE
BILLINGS MT 59101
Loyd Allison, UST Class A Operator
Chris Booth, UST Class A Operator
Loyd Allison, UST Class B Operator
Chris Booth, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
13
1/9/2003
Steel Clad
Flexible Plastic
10/17/2012
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-300 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
4782
Currently in Use
Diesel
20,000
Report Generation Date: 8/31/2016
Page 142
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS DIGITAL AIRPORT SURVEILLANCE RADAR
1901 TERMINAL CIR
BILLINGS, MT 59105
YELLOWSTONE
Charles Osborne, (406) 657-6981
Owners/Operators: Federal Aviation Admin Yellowstone SSC, Owner
Sys Fac ID: 56-14077
Last Inspected On: 1/23/2015
Operating Permit Renewal Date: 3/26/2018
(406)-657-6455
FAA YELLOWSTONE SSC
1540 LAKE ELMO DR STE 6
BILLINGS MT 59105-1798
Michael Atkins, UST Class A Operator
Kim Feldt, UST Class A Operator
Paul Henley, UST Class A Operator
George Lamb, UST Class A Operator
Evan Wolfe, UST Class A Operator
Michael Atkins, UST Class B Operator
Paul Henley, UST Class B Operator
Kim Feldt, UST Class B Global Operator
Paul Henley, UST Class B Global Operator
George Lamb, UST Class B Global Operator
Evan Wolfe, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
13
12/30/2002
Fiberglass Reinforced Plastic
Flexible Plastic
7/3/2013
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Positive Shutoff, High
Level Alarm
Yes
Not Applicable
4780
Currently in Use
Diesel
1,000
Report Generation Date: 8/31/2016
Page 143
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY #731
1280 GRAND AVE
BILLINGS, MT 59102
(952) 830-8899
Sys Fac ID: 56-14090
Last Inspected On: 5/13/2015
Operating Permit Renewal Date: 10/1/2018
YELLOWSTONE
Owners/Operators: Rocky Mountain Oil Inc, Owner
(952)-830-8700
Holiday #731, Operator
(952)-830-8747
ATTN: ENVIRONMENTAL DIRECTOR
4567 AMERICAN BLVD W
BLOOMINGTON MN 55437
1280 GRAND AVE
BILLINGS MT 59102
Robert Deninno, UST Class A Operator
Michael Anderson, UST Class B Operator
Denny Munger, UST Class B Operator
Jason Vetsch, UST Class B Operator
Shelley Waters, UST Class B Operator
Darold Heck, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
13
6/24/2003
Fiberglass Reinforced Plastic
Flexible Plastic
6/22/2012
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm,
Positive Shutoff
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
4844
Currently in Use
Gasoline
15,000
2
4845
Currently in Use
Gasoline
13
10,000
3
4846
Currently in Use
Diesel
6/24/2003
5/9/2012
13
5,000
Report Generation Date: 8/31/2016
6/24/2003
5/7/2012
Page 144
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
RADISSON HOTEL BILLINGS
5500 MIDLAND RD
BILLINGS, MT 59101
YELLOWSTONE
Tony Contreraz, (406) 248-7701
Owners/Operators: 5500 Midland Holdings LLC, Owner
Sys Fac ID: 56-14103
Last Inspected On: 4/20/2016
Operating Permit Renewal Date: 6/22/2019
(386)-947-7741
1275 W GRANADA BLVD STE 3B
ORMOND BEACH FL 32174
Jonathan Harpole, UST Class A Operator
Douglas Schmidt, UST Class A Operator
Douglas Schmidt, UST Class B Operator
Jonathan Harpole, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
12
3/12/2004
Cathodically Protected Steel
Flexible Plastic
4/20/2016
None
Not Required
Automatic Tank Gauging 0.2
EECO 1500 , EMCO Electronics
Secondary Containment Chase
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
4887
Currently in Use
Diesel
500
Report Generation Date: 8/31/2016
4/20/2016
9/20/2004
Page 145
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
BILLINGS OPERATION CENTER
4848 MIDLAND RD
BILLINGS, MT 59101
YELLOWSTONE
Clifford Fillner, (406) 657-8216
Owners/Operators: City of Billings Operation Center, Owner
Sys Fac ID: 56-14118
Last Inspected On: 10/16/2013
Operating Permit Renewal Date: 12/10/2016
(406)-657-8216
PO BOX 1178
BILLINGS MT 59103-1178
Larry Deschene, UST Class A Operator
Troy Namen, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4935
Currently in Use
Diesel
12
7/9/2004
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
12
7/9/2004
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
12
7/9/2004
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
12
7/9/2004
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Ball Float Valve
Yes
Not Applicable
10,000
2
4936
Currently in Use
Diesel
10,000
3
4937
Currently in Use
Gasoline
5,000
4
4938
Currently in Use
Gasoline
5,000
Report Generation Date: 8/31/2016
Page 146
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
AIR TRAFFIC CONTROL TOWER
1907 TERMINAL CIR
BILLINGS, MT 59105
YELLOWSTONE
Chuck Osborn, (406) 657-6981
Owners/Operators: Federal Aviation Admin Yellowstone SSC, Owner
Sys Fac ID: 56-14127
Last Inspected On: 2/12/2014
Operating Permit Renewal Date: 4/18/2017
(406)-657-6455
FAA YELLOWSTONE SSC
1540 LAKE ELMO DR STE 6
BILLINGS MT 59105-1798
Michael Atkins, UST Class A Operator
Kim Feldt, UST Class A Operator
Craig Fitzgerald, UST Class A Operator
Paul Henley, UST Class A Operator
George Lamb, UST Class A Operator
Evan Wolfe, UST Class A Operator
Michael Atkins, UST Class B Operator
Paul Henley, UST Class B Operator
Kim Feldt, UST Class B Global Operator
Craig Fitzgerald, UST Class B Global Operator
Paul Henley, UST Class B Global Operator
George Lamb, UST Class B Global Operator
Evan Wolfe, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
11
12/9/2004
Fiberglass Reinforced Plastic
Flexible Plastic
9/1/2013
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Double-Walled
U.S. Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
4976
Currently in Use
Diesel
4,000
Report Generation Date: 8/31/2016
Page 147
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 3
3150 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: New Inns Inc, Owner
Sys Fac ID: 60-15023
Last Inspected On: 12/21/2015
Operating Permit Renewal Date: 4/2/2019
PO BOX 6000
BUTTE MT 59702
Charles A Armstrong, UST Class A Operator
Don Edmisten, UST Class A Operator
Charles A Armstrong, UST Class B Global Operator
Don Edmisten, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5062
Currently in Use
Gasoline
10
4/14/2006
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
20,000
2
5056
Currently in Use
Gasoline
5/1/2006
10
4/1/2006
5/1/2006
10,000
3
5057
Currently in Use
Diesel
10
8,000
Report Generation Date: 8/31/2016
4/6/2006
5/1/2006
Page 148
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 3
3150 KING AVE W
BILLINGS, MT 59102
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 60-15023
Last Inspected On: 12/21/2015
Operating Permit Renewal Date: 4/2/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
5058
Currently in Use
Diesel
10
4/14/2006
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
10
4/6/2006
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
10,000
5
5059
Currently in Use
Diesel
5/1/2006
8,000
6
5060
Currently in Use
Diesel
10
8,000
Report Generation Date: 8/31/2016
4/6/2006
5/1/2006
Page 149
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
MCDONALD LIGHTHOUSE
3212 1ST AVE S
BILLINGS, MT 59101
YELLOWSTONE
Dale Orth, (406) 670-2012
Owners/Operators: Yellowstone Boys & Girls Ranch, Owner
DALE ORTH, Operator
Sys Fac ID: 60-15027
Last Inspected On: 6/4/2015
Operating Permit Renewal Date: 9/6/2018
(406)-651-3100
(406)-670-2012
ATTN DALE ORTH
3212 1ST AVE S
BILLINGS MT 59101-3824
671 REPUBLIC AVE
BILLINGS MT 59105
Gregory Leeds, UST Class A Operator
DALE ORTH, UST Class A Operator
Rick Kelum, UST Class B Operator
DALE ORTH, UST Class B Operator
Patrick Friesen, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
10
2/6/2006
Fiberglass Reinforced Plastic
Flexible Plastic
6/4/2015
Double-Walled
Continuous Interstitial Monitoring
Continuous Interstitial Monitor
ILS-350 , Veeder Root
Double-Walled
U.S. Suction
MLLD Line Tightness Testing
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
5072
Currently in Use
Heating Oil
6,000
Report Generation Date: 8/31/2016
Page 150
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 385
3630 GABEL ROAD
BILLINGS, MT 59102
YELLOWSTONE
Jack Krueger, (406) 651-9872
Owners/Operators: Rocky Mountain Oil Co Inc, Owner
Sys Fac ID: 60-15065
Last Inspected On: 2/21/2014
Operating Permit Renewal Date: 5/20/2017
(952)-830-8899
ATTN: ENVIRONMENTAL DIRECTOR
PO BOX 1224
MINNEAPOLIS MN 55437-1123
Jack Krueger Jr, UST Class A Operator
Ronald VanDenBroeke, UST Class A Operator
Carrie Cook, UST Class B Operator
Terry Youngblood, UST Class B Operator
Linda French, UST Class B Global Operator
Jack Krueger Jr, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5139
Currently in Use
Gasoline
08
12/11/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor,
Manual Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Yes
12/24/2010
TLS-350/Gilbarco EMC , Veeder Root
12/11/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
12/22/2010
TLS-350/Gilbarco EMC , Veeder Root
12/11/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
12/16/2010
TLS-350/Gilbarco EMC , Veeder Root
20,000
2
5140
Currently in Use
Gasoline
08
12,000
3
5141
Currently in Use
Gasoline
08
8,000
Report Generation Date: 8/31/2016
Yes
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor,
Manual Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Yes
Yes
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor,
Manual Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Yes
Yes
Page 151
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
HOLIDAY STATIONSTORE 385
3630 GABEL ROAD
BILLINGS, MT 59102
YELLOWSTONE
Jack Krueger, (406) 651-9872
Sys Fac ID: 60-15065
Last Inspected On: 2/21/2014
Operating Permit Renewal Date: 5/20/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
5142
Currently in Use
Diesel
08
12/11/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor,
Manual Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
12/24/2010
TLS-350/Gilbarco EMC , Veeder Root
12/11/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
12/24/2010
TLS-350/Gilbarco EMC , Veeder Root
12,000
5
5143
Currently in Use
Diesel
08
8,000
Report Generation Date: 8/31/2016
Yes
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor,
Manual Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
Yes
Page 152
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS EXPRESS CENTER
2324 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Gary Carlson, (406) 248-2558
Owners/Operators: Automatic Car Wash Inc, Owner
Sys Fac ID: 60-15096
Last Inspected On: 10/17/2014
Operating Permit Renewal Date: 1/10/2018
(406)-248-2558
PO BOX 1278
BILLINGS MT 59103-1278
Gene Carlson, UST Class A Operator
Gene Carlson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5160
Currently in Use
Gasoline
08
6/29/2008
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Not Applicable
Continuous Interstitial Monitor, ELLD Line
Tightness Testing
Yes
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Not Applicable
Continuous Interstitial Monitor, ELLD Line
Tightness Testing
Yes
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Not Applicable
Continuous Interstitial Monitor, ELLD Line
Tightness Testing
Yes
12,000
2
5161
Currently in Use
Gasoline
7/21/2014
08
5,000
3
5162
Currently in Use
Diesel
6/29/2008
7/21/2014
08
5,000
Report Generation Date: 8/31/2016
6/29/2008
7/20/2014
Page 153
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
DONS EXPRESS CENTER
2324 MAIN ST
BILLINGS, MT 59105
YELLOWSTONE
Gary Carlson, (406) 248-2558
Sys Fac ID: 60-15096
Last Inspected On: 10/17/2014
Operating Permit Renewal Date: 1/10/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
5163
Currently in Use
Diesel
08
6/29/2008
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
High Level Alarm
Yes
Not Applicable
Continuous Interstitial Monitor, ELLD Line
Tightness Testing
Yes
5,000
Report Generation Date: 8/31/2016
7/23/2014
Page 154
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Lynch Flying Service Inc
1482 AVIATION PLACE
BILLINGS, MT 59105
(406) 252-0508
Sys Fac ID: 60-15100
Last Inspected On: 8/8/2014
Operating Permit Renewal Date: 10/15/2017
YELLOWSTONE
Owners/Operators: Edwards Jet Center, Owner
(406)-252-0508
LYNCH FLYING SERVICE INC, Operator
(406)-252-0508
1691 AVIATION PL
BILLINGS MT 59105-1994
DBA EDWARDS JET CENTER
1691 AVIATION PL
BILLINGS MT 59105-1981
Warren Nemitz, UST Class A Operator
Joel Simmons, UST Class A Operator
Aaron VanLuchene, UST Class A Operator
Joel Simmons, UST Class B Operator
Warren Nemitz, UST Class B Global Operator
Aaron VanLuchene, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5172
Currently in Use
Jet Fuel
08
2/25/2008
7/28/2014
Fiberglass Reinforced Plastic
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Not Listed
Continuous Interstitial Monitor, Not Listed
High Level Alarm
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Not Listed
Continuous Interstitial Monitor, Not Listed
Fiberglass Reinforced Plastic
Double-Walled
Continuous Interstitial Monitoring
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
No Piping
None
Not Listed
Continuous Interstitial Monitor, Not Listed
20,000
2
5173
Currently in Use
Jet Fuel
08
2/25/2008
7/28/2014
20,000
3
5174
Currently in Use
Aviation Gas
08
12,000
Report Generation Date: 8/31/2016
2/25/2008
7/28/2014
Yes
High Level Alarm
Yes
Not Applicable
Yes
High Level Alarm
Yes
Not Applicable
Yes
Page 155
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 4
2711 N FRONTAGE RD
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: Town Pump Inc, Owner
Sys Fac ID: 60-15104
Last Inspected On: 2/1/2016
Operating Permit Renewal Date: 4/2/2019
(406)-497-6700
Park Street Holdings LLC, Operator
(406)-467-6700
PO BOX 6000
BUTTE MT 59702-2534
PO BOX 6000
BUTTE MT 59702-6000
Charles A Armstrong, UST Class A Operator
Don Edmisten, UST Class A Operator
Charles A Armstrong, UST Class B Global Operator
Don Edmisten, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
07
12/15/2008
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
5180
Currently in Use
Diesel
30,000
2
07
12/15/2008
5181
Currently in Use
Diesel
30,000
3
07
5182
Currently in Use
Diesel
30,000
Report Generation Date: 8/31/2016
12/15/2008
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Page 156
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
TOWN PUMP INC BILLINGS 4
2711 N FRONTAGE RD
BILLINGS, MT 59101
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 60-15104
Last Inspected On: 2/1/2016
Operating Permit Renewal Date: 4/2/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
07
12/15/2008
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-450 , Veeder Root
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor
5183
Currently in Use
Gasoline
24,000
5
07
12/18/2008
5184
Currently in Use
Diesel
8,000
6
07
12/18/2008
5185
Currently in Use
Gasoline
24,000
7
07
5186
Currently in Use
Diesel
8,000
Report Generation Date: 8/31/2016
12/15/2008
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Yes
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Yes
Page 157
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SAM'S CLUB
4420 KING AVE E
BILLINGS, MT 59101
YELLOWSTONE
John May, (479) 277-9639
Owners/Operators: WALMART STORES INC, Owner
Sys Fac ID: 60-15138
Last Inspected On: 4/6/2016
Operating Permit Renewal Date: 6/17/2019
(479)-273-4000
ATTN JOHN MAY
702 SW 8TH ST
BENTONVILLE AR 72716-6209
Kevin E Allen, UST Class A Operator
Taryn Bailey, UST Class A Operator
Dustin Branson, UST Class A Operator
Donald Elderbaum, UST Class A Operator
Steven Hodge, UST Class A Operator
Scott Murray, UST Class A Operator
Dustin Branson, UST Class B Operator
Joseph Khan, UST Class B Operator
Kevin E Allen, UST Class B Global Operator
Taryn Bailey, UST Class B Global Operator
Donald Elderbaum, UST Class B Global Operator
Steven Hodge, UST Class B Global Operator
Scott Murray, UST Class B Global Operator
James Ray, UST Class B Global Operator
Rick Weaver, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
06
9/8/2009
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
4/6/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
OPW 1500 , OPW
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
5210
Currently in Use
Gasoline
20,000
Report Generation Date: 8/31/2016
Continuous Interstitial Monitor
Yes
Page 158
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
SAM'S CLUB
4420 KING AVE E
BILLINGS, MT 59101
YELLOWSTONE
John May, (479) 277-9639
Sys Fac ID: 60-15138
Last Inspected On: 4/6/2016
Operating Permit Renewal Date: 6/17/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
2
06
9/8/2009
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
4/6/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
OPW 1500 , OPW
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Continuous Interstitial Monitor
Yes
9/8/2009
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
4/6/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
OPW 1500 , OPW
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
Continuous Interstitial Monitor
Yes
9/8/2009
Fiberglass Reinforced Plastic
Flexible Plastic
Double-Walled
Pressurized
MLLD Line Tightness Testing
4/6/2016
Double-Walled
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
OPW 1500 , OPW
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
5211
Currently in Use
Gasoline
20,000
3
06
5212
Currently in Use
Gasoline
12,000
4
06
5213
Currently in Use
Diesel
8,000
Report Generation Date: 8/31/2016
Continuous Interstitial Monitor
Yes
Page 159
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Rental Car Wash
3301 OVERLOOK DR
BILLINGS, MT 59105
YELLOWSTONE
DONALD KIM ANNIN, (406) 657-8482
Owners/Operators: Billings Logan International Airport, Owner
Donald Kim Annin, Operator
Sys Fac ID: 60-15179
Last Inspected On: 12/23/2014
Operating Permit Renewal Date: 3/24/2018
(406)-657-8482
(406)-657-8495
1901 TERMINAL CIR STE 216
BILLINGS MT 59105-1991
BILLINGS LOGAN INTERNATIONAL AIRPORT
1901 TERMINAL CIR STE 216
BILLINGS MT 59105-1991
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5288
Currently in Use
Gasoline
05
4/11/2011
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Ball Float Valve
Yes
Not Applicable
20,000
Report Generation Date: 8/31/2016
12/23/2014
Yes
Page 160
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
Fed Ex Freight
7107 COMMERCIAL AVE
BILLINGS, MT 59101
YELLOWSTONE
Chong Lee, (408) 654-3112
Owners/Operators: K W Billings, LLC, Owner
Sys Fac ID: 60-15181
Last Inspected On: 1/16/2015
Operating Permit Renewal Date: 3/17/2018
(619)-435-1614
941 ORANGE AVE STE 512
CORONADO CA 92118
Adren Hillenburg, UST Class A Operator
Chong Lee, UST Class A Operator
Nick Haynes, UST Class B Operator
Kevin Roberts, UST Class B Operator
Adren Hillenburg, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5293
Currently in Use
Diesel
05
5/23/2011
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Not Applicable
20,000
Report Generation Date: 8/31/2016
7/16/2014
Yes
Page 161
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
FEDEX GROUND BILLINGS
3815 HESPER ROAD
BILLINGS, MT 59106
YELLOWSTONE
Nancy Beaumont, (412) 262-7347
Owners/Operators: FedEx Ground, Owner
Sys Fac ID: 60-15209
Last Inspected On: 12/15/2014
Operating Permit Renewal Date: 12/30/2017
(412)-262-7347
1000 FEDEX DRIVE
MOON TOWNSHIP PA 15108
Lorraine Nogrady, UST Class A Operator
Lorraine Nogrady, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
02
10/1/2013
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
11/6/2013
8/13/2014
Double-Walled
Mechanical Line Leak Detector
Continuous Interstitial Monitor
TLS-450 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
MLLD Line Tightness Testing, Not Listed
Ball Float Valve, High
Level Alarm
Yes
Not Applicable
10/1/2013
Fiberglass Reinforced Plastic
Fiberglass Reinforced Plastic
11/9/2013
8/13/2014
Double-Walled
Mechanical Line Leak Detector
Continuous Interstitial Monitor
TLS-450 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
MLLD Line Tightness Testing, Not Listed
10/1/2013
Fiberglass Reinforced Plastic
Other
11/9/2014
Double-Walled
Continuous Interstitial Monitoring
Continuous Interstitial Monitor
TLS-450 , Veeder Root
Double-Walled
Pressurized
Continuous Interstitial Monitor
Not Listed
5447
Currently in Use
Diesel
30,000
2
02
5448
Currently in Use
Diesel
30,000
3
02
5449
Currently in Use
>B20
12,000
Report Generation Date: 8/31/2016
Ball Float Valve, High
Level Alarm
Yes
Not Applicable
Ball Float Valve, High
Level Alarm
Yes
Not Applicable
Page 162
Facility Summary in YELLOWSTONE County in the City of BILLINGS
Location:
Contact:
OLD DOMINION FREIGHT LINES
1030 INTERMOUNTAIN STREET
BILLINGS, MT 59101
YELLOWSTONE
Robert Alexander, (336) 822-5571
Owners/Operators: Old Dominion Freight Line, Owner
Sys Fac ID: 60-15216
Last Inspected On: 7/25/2016
Operating Permit Renewal Date: 8/25/2019
(336)-889-5000
Robert Alexander, Operator
(406)-256-6506
ATTN: CONTROL MAINTENANCE
500 OLD DOMINION WAY
THOMASVILLE NC 27360
1030 INTERMOUNTAIN
BILLINGS MT 59101
Richard A McGuire, UST Class A Operator
Lorrin Wallace, UST Class A Operator
Ben Figg, UST Class B Global Operator
Lorrin Wallace, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
1
5393
Currently in Use
Diesel
03
Yes
10/1/2012
Unknown
Double-Walled
Electronic Line Leak Detector
Deferred
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor, Not Listed
15,000
Report Generation Date: 8/31/2016
7/25/2016
TLS-350/Gilbarco EMC , Veeder Root
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
No
Not Applicable
Yes
Page 163
Facility Summary in YELLOWSTONE County in the City of BROADVIEW
Location:
Contact:
BROADVIEW 500 KV SUBSTATION
MT HIGHWAY 3
BROADVIEW, MT 59015
YELLOWSTONE
Beth Stimatz, (406) 497-2687
Owners/Operators: Northwestern Energy, Owner
Sys Fac ID: 56-01431
Last Inspected On: 7/12/2013
Operating Permit Renewal Date: 11/7/2016
(406)-655-2521
405 S 20TH ST W
BILLINGS MT 59102
John Habeger, UST Class A Operator
Darren Brockel, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
34
4/30/1982
Fiberglass Reinforced Plastic
Flexible Plastic
7/5/2012
None
Not Required
Automatic Tank Gauging 0.2
Double-Walled
Safe Suction
Continuous Interstitial Monitor
Flapper Valve (Auto
Shutoff)
Yes
Not Applicable
1686
Currently in Use
Diesel
2,500
Report Generation Date: 8/31/2016
Page 164
Facility Summary in YELLOWSTONE County in the City of BROADVIEW
Location:
Contact:
BROADVIEW SERVICE STATION LLC
16437 IOWA AVE
BROADVIEW, MT 59015
YELLOWSTONE
Elisha Lewis, (406) 322-5214
Owners/Operators: Broadview Service Station LLC, Owner
Farmers Union Trading Co Columbus, Operator
Sys Fac ID: 56-02373
Last Inspected On: 12/23/2014
Operating Permit Renewal Date: 2/24/2018
(406)-667-2253
(406)-322-5618
16437 IOWA AVE
BROADVIEW MT 59015-9751
PO BOX 509
COLUMBUS MT 59019-0509
Sonia Hollingsworth, UST Class A Operator
Jarred Mosdal, UST Class A Operator
Nathanial Williams, UST Class A Operator
Scott Hollingsworth, UST Class B Operator
Sonia Hollingsworth, UST Class B Operator
Susan Wood, UST Class B Operator
Sonia Hollingsworth, UST Class B Global Operator
Elisha Lewis, UST Class B Global Operator
Nathanial Williams, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
6
3410
Currently in Use
Gasoline
20
5/1/1996
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Galvanic
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Galvanic
12/23/2014
4,000
7
3411
Currently in Use
Gasoline
7/28/2014
20
6,000
Report Generation Date: 8/31/2016
5/1/1996
12/23/2014
7/28/2014
Page 165
Facility Summary in YELLOWSTONE County in the City of BROADVIEW
Location:
Contact:
BROADVIEW SERVICE STATION LLC
16437 IOWA AVE
BROADVIEW, MT 59015
YELLOWSTONE
Elisha Lewis, (406) 322-5214
Sys Fac ID: 56-02373
Last Inspected On: 12/23/2014
Operating Permit Renewal Date: 2/24/2018
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
3412
Currently in Use
Diesel
20
5/1/1996
Cathodically Protected Steel
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
Ball Float Valve
Yes
Galvanic
4,000
Report Generation Date: 8/31/2016
12/23/2014
7/28/2014
Page 166
Facility Summary in YELLOWSTONE County in the City of CUSTER
Location:
Contact:
CUSTER STATION
523 2ND ST
CUSTER, MT 59024
YELLOWSTONE
Kirk Marzolf, (406) 967-3100
Owners/Operators: Farmers Union Oil Co, Owner
Sys Fac ID: 56-05291
Last Inspected On: 2/6/2016
Operating Permit Renewal Date: 4/30/2019
(406)-967-3100
PO BOX 309
WORDEN MT 59088-0309
Scott Black, UST Class A Operator
Kirk Marzolf, UST Class A Operator
Tammy Onstine, UST Class B Operator
Marion Perrin, UST Class B Operator
Lenore Rogers, UST Class B Operator
Sherry Ward, UST Class B Operator
Trina Wilson, UST Class B Operator
Scott Black, UST Class B Global Operator
Marion Perrin, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
4079
Currently in Use
Diesel
5,000
17
Yes
7/1/1999
6/21/2013
Unknown
None
Continuous Interstitial Monitoring
Deferred
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
Yes
Not Applicable
6
4080
Currently in Use
Diesel
12,000
17
Yes
7/1/1999
6/21/2013
Unknown
None
Continuous Interstitial Monitoring
Deferred
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
Yes
Not Applicable
7
4081
Currently in Use
Gasoline
12,000
17
Yes
7/1/1999
6/21/2013
Unknown
None
Continuous Interstitial Monitoring
Deferred
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
Yes
Not Applicable
Report Generation Date: 8/31/2016
Page 167
Facility Summary in YELLOWSTONE County in the City of CUSTER
Location:
Contact:
CUSTER STATION
523 2ND ST
CUSTER, MT 59024
YELLOWSTONE
Kirk Marzolf, (406) 967-3100
Sys Fac ID: 56-05291
Last Inspected On: 2/6/2016
Operating Permit Renewal Date: 4/30/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
4082
Currently in Use
Gasoline
10,000
17
Yes
7/1/1999
6/21/2013
Unknown
None
Continuous Interstitial Monitoring
Deferred
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Continuous Interstitial Monitor
Yes
Not Applicable
Report Generation Date: 8/31/2016
Page 168
Facility Summary in YELLOWSTONE County in the City of HUNTLEY
Location:
Contact:
HUNTLEY EXPRESSWAY
135 NORTHERN AVE
HUNTLEY, MT 59037
YELLOWSTONE
Jim Woods, (406) 640-2860
Owners/Operators: Set Five LLC, Owner
Sys Fac ID: 56-00627
Last Inspected On: 9/30/2014
Operating Permit Renewal Date: 12/16/2017
(406)-348-9209
Bernie Greenfield, Operator
PO BOX 161730
BIG SKY MT 59716
1126 YORKTOWN ST
BILLINGS MT 59105
Bernie Greenfield, UST Class A Operator
Cheryl Greenfield, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
3660
Currently in Use
Gasoline
5,000
17
11/1/1998
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
4
3661
Currently in Use
Diesel
5,000
17
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
5
3662
Currently in Use
Gasoline
10,000
17
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.2
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
9/30/2014
11/1/1998
9/30/2014
Report Generation Date: 8/31/2016
11/1/1998
9/30/2014
Page 169
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL TRAVEL CENTER
11360 S FRONTAGE RD
LAUREL, MT 59044
YELLOWSTONE
Kelly Gelski, (440) 808-7406
Owners/Operators: TA Operating LLC, Owner/Operator
Sys Fac ID: 56-00626
Last Inspected On: 10/30/2013
Operating Permit Renewal Date: 12/31/2016
(440)-808-7406
24601 CENTER RIDGE RD
WESTLAKE OH 44145
Renee Andrews, UST Class A Operator
Connie Pelican, UST Class A Operator
Renee Andrews, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1795
Currently in Use
Diesel
10,000
45
5/3/1971
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
2
1796
Currently in Use
Diesel
10,000
48
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
3
1794
Currently in Use
Diesel
10,000
48
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
4
1792
Currently in Use
Gasoline
10,000
48
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
10/30/2013
12/30/2013
5/2/1968
10/30/2013
12/30/2013
5/2/1968
10/30/2013
12/30/2013
Report Generation Date: 8/31/2016
5/2/1968
10/30/2013
12/30/2013
Page 170
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL TRAVEL CENTER
11360 S FRONTAGE RD
LAUREL, MT 59044
YELLOWSTONE
Kelly Gelski, (440) 808-7406
Sys Fac ID: 56-00626
Last Inspected On: 10/30/2013
Operating Permit Renewal Date: 12/31/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
1793
Currently in Use
Diesel
10,000
48
5/2/1968
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
6
1791
Currently in Use
Gasoline
6,000
48
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
7
1797
Currently in Use
Diesel
10,000
48
Cathodically Protected Steel
Lined Interior/Impressed Current
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Steel
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
10/30/2013
12/30/2013
5/2/1968
10/30/2013
12/30/2013
Report Generation Date: 8/31/2016
5/2/1968
10/30/2013
12/30/2013
Page 171
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL SERVICE CENTER INC UST
201 W MAIN ST
LAUREL, MT 59044
YELLOWSTONE
David Powers, (406) 628-4216
Owners/Operators: John Munro, Owner
Sys Fac ID: 56-01069
Last Inspected On: 7/8/2014
Operating Permit Renewal Date: 8/20/2017
(406)-628-4216
Laurel Service Center Inc, Operator
(406)-628-4216
201 W MAIN ST
LAUREL MT 59044-3108
201 W MAIN ST
LAUREL MT 59044-3108
John Munro, UST Class A Operator
John Munro, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
30
4/29/1986
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2007
Impressed Current
Not Required
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Safe Suction
Deferred
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
4/28/1988
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2007
Impressed Current
Mechanical Line Leak Detector
Not Listed
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
Not Listed
4/29/1987
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2006
None
Not Required
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Safe Suction
Deferred
4/28/1988
Cathodically Protected Steel
No Piping
6/20/2014
8/8/2007
None
Mechanical Line Leak Detector
Not Listed
TLS-350/Gilbarco EMC , Veeder Root
None
Safe Suction
Not Listed
1808
Currently in Use
Gasoline
10,000
2
28
1809
Temporarily Out of Use
Gasoline
10,000
10
29
1810
Currently in Use
Gasoline
10,000
11
28
1811
Temporarily Out of Use
Diesel
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Page 172
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL SERVICE CENTER INC UST
201 W MAIN ST
LAUREL, MT 59044
YELLOWSTONE
David Powers, (406) 628-4216
Sys Fac ID: 56-01069
Last Inspected On: 7/8/2014
Operating Permit Renewal Date: 8/20/2017
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
12
28
4/28/1988
Cathodically Protected Steel
No Piping
6/20/2014
None
Safe Suction
Not Listed
8/8/2007
None
Not Required
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
4/28/1988
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2007
None
Not Required
Not Listed
TLS-350/Gilbarco EMC , Veeder Root
None
Safe Suction
Not Listed
4/28/1988
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2007
None
Mechanical Line Leak Detector
Not Listed
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
Not Listed
11/15/1998
Cathodically Protected Steel
Fiberglass Reinforced Plastic
6/20/2014
8/8/2007
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
MLLD Line Tightness Testing
1812
Temporarily Out of Use
Diesel
8,000
13
28
1813
Temporarily Out of Use
Diesel
4,000
14
28
1814
Temporarily Out of Use
Gasoline
4,000
15
17
1815
Currently in Use
Gasoline
10,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Page 173
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN & COUNTRY SUPPLY LAUREL ASSN
800 E MAIN ST
LAUREL, MT 59044
YELLOWSTONE
Wes Burley, (406) 628-6314
Owners/Operators: Town & Country Supply Association, Owner
Sys Fac ID: 56-04497
Last Inspected On: 9/19/2013
Operating Permit Renewal Date: 12/14/2016
(406)-628-6314
PO BOX 367
LAUREL MT 59044-0367
Wesley Burley, UST Class A Operator
Karissa DeRudder, UST Class A Operator
Vincent Farr, UST Class A Operator
Ronni Nace, UST Class A Operator
Steven Shelton, UST Class A Operator
Karissa DeRudder, UST Class B Operator
Vincent Farr, UST Class B Operator
Ronni Nace, UST Class B Operator
Jennifer Reinhardt, UST Class B Operator
Steven Shelton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
4470
Currently in Use
Gasoline
2,000
26
2/12/1990
Steel Clad
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
2
1520
Currently in Use
Gasoline
4,000
26
Steel Clad
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
3
4471
Currently in Use
Diesel
2,000
26
Steel Clad
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
9/19/2013
9/19/2013
2/12/1990
9/19/2013
9/19/2013
Report Generation Date: 8/31/2016
2/12/1990
9/19/2013
9/19/2013
Page 174
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN & COUNTRY SUPPLY LAUREL ASSN
800 E MAIN ST
LAUREL, MT 59044
YELLOWSTONE
Wes Burley, (406) 628-6314
Sys Fac ID: 56-04497
Last Inspected On: 9/19/2013
Operating Permit Renewal Date: 12/14/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
11
1518
Currently in Use
Gasohol/Ethanol
4,000
26
2/12/1990
Steel Clad
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
12
4472
Currently in Use
Diesel
4,000
26
Steel Clad
None
Mechanical Line Leak Detector
Automatic Tank Gauging 0.2
Fiberglass Reinforced Plastic
None
Pressurized
MLLD Line Tightness Testing
High Level Alarm
Yes
Galvanic
9/19/2013
9/19/2013
Report Generation Date: 8/31/2016
2/12/1990
9/19/2013
9/19/2013
Page 175
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
FASTLANE C STORES
815 E MAIN ST
LAUREL, MT 59044
(406) 628-6204
Sys Fac ID: 56-05083
Last Inspected On: 7/28/2014
Operating Permit Renewal Date: 9/25/2017
YELLOWSTONE
Owners/Operators: East Main Development LLC, Owner
Fastlane C Stores, Operator
(406)-628-6204
(406)-628-6204
1415 RIDGE DR
LAUREL MT 59044
1415 RIDGE DR
LAUREL MT 59044
Dan Foos, UST Class A Operator
Dan Foos, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
40
10/1/1975
Bare Steel
Fiberglass Reinforced Plastic
7/28/2014
5/27/2014
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
Automatic Tank Gauging 0.2
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
10/1/1975
Bare Steel
Fiberglass Reinforced Plastic
7/28/2014
5/25/2014
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
Automatic Tank Gauging 0.2
10/1/1975
Bare Steel
Fiberglass Reinforced Plastic
7/28/2014
6/14/2014
Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
None
Pressurized
Automatic Tank Gauging 0.2
3831
Currently in Use
Gasoline
10,000
2
40
3832
Currently in Use
Diesel
5,200
3
40
3833
Currently in Use
Gasoline
6,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current
Page 176
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
CONOMART SUPERSTORE 3
519 W MAIN ST
LAUREL, MT 59044
YELLOWSTONE
Dennis Whitmore, (406) 628-2034
Sys Fac ID: 56-06965
Last Inspected On: 1/25/2016
Operating Permit Renewal Date: 6/2/2019
Owners/Operators: C Store Properties LLC, Owner
(406)-651-5101
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Jewell Borchardt, UST Class B Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1173
Currently in Use
Gasoline
20
10/17/1995
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
1/29/2016
8,000
2
1174
Currently in Use
Diesel
11/9/2009
20
8,000
Report Generation Date: 8/31/2016
10/17/1995
1/29/2016
11/9/2009
Page 177
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
CONOMART SUPERSTORE 3
519 W MAIN ST
LAUREL, MT 59044
YELLOWSTONE
Dennis Whitmore, (406) 628-2034
Sys Fac ID: 56-06965
Last Inspected On: 1/25/2016
Operating Permit Renewal Date: 6/2/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
1172
Currently in Use
Gasoline
20
10/17/1995
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
Gilbarco EMC Basic , Gilbarco
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
Continuous Interstitial Monitor
High Level Alarm
Yes
Galvanic
10,000
Report Generation Date: 8/31/2016
1/29/2016
11/9/2009
Page 178
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
CONOMART SUPERSTORE 2
411 E 1ST ST
LAUREL, MT 59044
YELLOWSTONE
Whitmore Dennis, (406) 252-4661
Sys Fac ID: 56-06966
Last Inspected On: 9/22/2015
Operating Permit Renewal Date: 3/17/2019
Owners/Operators: C Store Properties LLC, Owner
(406)-651-5101
GM Cono Stores LLC, Operator
(406)-252-4661
PO BOX 80391
BILLINGS MT 59108
PO BOX 30335
BILLINGS MT 59107
Laura Geffre, UST Class A Operator
Bill Grunstead, UST Class A Operator
Ken Jackson, UST Class A Operator
Charlie McHenry, UST Class A Operator
Roger Schmechel, UST Class A Operator
Stephanie Zierke, UST Class A Operator
Linda Degele, UST Class B Operator
Laura Geffre, UST Class B Operator
Roger Schmechel, UST Class B Operator
Janice Wade, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
1177
Currently in Use
Gasoline
39
4/22/1977
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
9/22/2015
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
5/22/2015
TLS-350/Gilbarco EMC , Veeder Root
4/22/1977
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, ELLD Line Tightness Testing
High Level Alarm
Yes
Impressed Current
9/22/2015
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
5/22/2015
TLS-350/Gilbarco EMC , Veeder Root
10,000
2
1176
Currently in Use
Gasoline
39
10,000
Report Generation Date: 8/31/2016
Page 179
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
CONOMART SUPERSTORE 2
411 E 1ST ST
LAUREL, MT 59044
YELLOWSTONE
Whitmore Dennis, (406) 252-4661
Sys Fac ID: 56-06966
Last Inspected On: 9/22/2015
Operating Permit Renewal Date: 3/17/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
3
1175
Currently in Use
Diesel
39
4/22/1977
Fiberglass Reinforced Plastic
None
Pressurized
Automatic Tank Gauging 0.2, ELLD Line Tightness
Testing
High Level Alarm
Yes
Impressed Current
9/22/2015
Bare Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
5/16/2015
TLS-350/Gilbarco EMC , Veeder Root
4,000
Report Generation Date: 8/31/2016
Page 180
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL CENEX C STORE
315 S 1ST AVE
LAUREL, MT 59044
YELLOWSTONE
Wayne M Reese, (406) 628-8660
Owners/Operators: Town & Country Supply Association, Owner
Sys Fac ID: 56-08161
Last Inspected On: 9/26/2013
Operating Permit Renewal Date: 12/27/2016
(406)-628-6314
PO BOX 367
LAUREL MT 59044-0367
Wesley Burley, UST Class A Operator
Steven Shelton, UST Class A Operator
Cathy Culp, UST Class B Global Operator
Steven Shelton, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
5
1523
Currently in Use
Gasohol/Ethanol
21
5/22/1995
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
9/20/2013
12,000
6
1524
Currently in Use
Gasoline
21
5/22/1995
9/20/2013
12,000
7
1525
Currently in Use
Gasoline
21
5/22/1995
9/20/2013
12,000
Report Generation Date: 8/31/2016
Page 181
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
LAUREL CENEX C STORE
315 S 1ST AVE
LAUREL, MT 59044
YELLOWSTONE
Wayne M Reese, (406) 628-8660
Sys Fac ID: 56-08161
Last Inspected On: 9/26/2013
Operating Permit Renewal Date: 12/27/2016
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
8
1526
Currently in Use
Diesel
21
5/22/1995
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
Cathodically Protected Steel
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.2
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
High Level Alarm
Yes
Galvanic
9/20/2013
6,000
9
1527
Currently in Use
Diesel
21
5/22/1995
9/20/2013
6,000
Report Generation Date: 8/31/2016
Page 182
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN PUMP INC LAUREL
312 FIRST AVE S
LAUREL, MT 59044
YELLOWSTONE
Trent Biggers, (406) 497-6700
Owners/Operators: Major Brands Distributing Imports Inc, Owner
Sys Fac ID: 56-08710
Last Inspected On: 2/29/2016
Operating Permit Renewal Date: 4/29/2019
(406)-497-6700
PO BOX 6000
BUTTE MT 59702-6000
Charles A Armstrong, UST Class A Operator
Don Edmisten, UST Class A Operator
Charles A Armstrong, UST Class B Global Operator
Don Edmisten, UST Class B Global Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
42
4/14/1974
Cathodically Protected Steel
Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
None
Pressurized
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
11/18/2014
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
4/14/1974
Cathodically Protected Steel
Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
None
Pressurized
11/18/2014
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
4/14/1974
Cathodically Protected Steel
Steel
Lined Interior/Impressed Current
Electronic Line Leak Detector
None
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
2668
Currently in Use
Diesel
8,000
2
42
2669
Currently in Use
Gasoline
8,000
3
42
2670
Currently in Use
Gasoline
8,000
Report Generation Date: 8/31/2016
11/18/2014
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Page 183
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN PUMP INC LAUREL
312 FIRST AVE S
LAUREL, MT 59044
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-08710
Last Inspected On: 2/29/2016
Operating Permit Renewal Date: 4/29/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
4
36
4/14/1980
Cathodically Protected Steel
Fiberglass Reinforced Plastic
None
Electronic Line Leak Detector
Double-Walled
Pressurized
Flapper Valve (Auto
Shutoff), Ball Float
Valve
Yes
Impressed Current,
Galvanic
11/18/2014
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
4/14/1980
Cathodically Protected Steel
Flexible Plastic
None
Electronic Line Leak Detector
Double-Walled
Pressurized
11/18/2014
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
4/1/1987
Cathodically Protected Steel
Flexible Plastic
None
Electronic Line Leak Detector
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
4589
Currently in Use
Diesel
12,000
5
36
2672
Currently in Use
Gasoline
12,000
6
29
4603
Currently in Use
Diesel
12,000
Report Generation Date: 8/31/2016
11/18/2014
Flapper Valve (Auto
Shutoff)
Yes
Impressed Current,
Galvanic
Flapper Valve (Auto
Shutoff), Ball Float
Valve
Yes
Impressed Current,
Galvanic
Page 184
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN PUMP INC LAUREL
312 FIRST AVE S
LAUREL, MT 59044
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-08710
Last Inspected On: 2/29/2016
Operating Permit Renewal Date: 4/29/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
7
4590
Currently in Use
Diesel
15
6/1/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
Ball Float Valve
Yes
Not Applicable
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
Ball Float Valve
Yes
Not Applicable
11/18/2014
5,000
8
4591
Currently in Use
Diesel
15
6/1/2001
11/18/2014
10,000
9
4592
Currently in Use
Diesel
15
6/1/2001
11/18/2014
5,000
10
4593
Currently in Use
Gasoline
15
10,000
Report Generation Date: 8/31/2016
6/1/2001
11/18/2014
Page 185
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
TOWN PUMP INC LAUREL
312 FIRST AVE S
LAUREL, MT 59044
YELLOWSTONE
Trent Biggers, (406) 497-6700
Sys Fac ID: 56-08710
Last Inspected On: 2/29/2016
Operating Permit Renewal Date: 4/29/2019
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
11
4594
Currently in Use
Gasoline
15
8/25/2001
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Continuous Interstitial Monitor, Stat. Inventory
Reconcilitation, Approved Remote Monitoring
TLS-350/Gilbarco EMC , Veeder Root
Flexible Plastic
Double-Walled
Pressurized
Stat. Inventory Reconcilitation, Approved Remote
Monitoring
Continuous Interstitial Monitor, Approved Remote
Monitoring
Ball Float Valve
Yes
Not Applicable
15,000
Report Generation Date: 8/31/2016
11/18/2014
Page 186
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
NORTHERN SKIES AVIATION
3900 FOX ROAD
LAUREL, MT 59044
YELLOWSTONE
Brent Larson, (406) 628-2219
Owners/Operators: Kent Potter, Owner
Sys Fac ID: 56-13474
Last Inspected On: 11/16/2015
Operating Permit Renewal Date: 1/27/2019
(406)-628-2219
NORTHERN SKIES AVIATION
PO BOX 936
LAUREL MT 59044-0936
Brent Larson, UST Class A Operator
Brent Larson, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
22
6/1/1994
Cathodically Protected Steel
Fiberglass Reinforced Plastic
Double-Walled
Mechanical Line Leak Detector
Manual Interstitial Monitor
Double-Walled
Pressurized
MLLD Line Tightness Testing
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
6/1/1994
Cathodically Protected Steel
Fiberglass Reinforced Plastic
11/16/2015
Double-Walled
Not Required
Manual Interstitial Monitor
Double-Walled
Safe Suction
Deferred
4295
Currently in Use
Gasoline
7,000
2
11/16/2015
11/16/2015
22
4296
Currently in Use
Gasoline
3,000
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 187
Facility Summary in YELLOWSTONE County in the City of LAUREL
Location:
Contact:
RICCIS EXPRESS
704 1ST AVE
LAUREL, MT 59044
YELLOWSTONE
Vince Ricci, (406) 628-7221
Owners/Operators: Ricci of Laurel Inc, Owner/Operator
Sys Fac ID: 60-15061
Last Inspected On: 7/6/2016
Operating Permit Renewal Date: 11/2/2019
(406)-628-7221
VINCE RICCI
704 1ST AVE
LAUREL MT 59044-2100
Vince Ricci, UST Class A Operator
Wes Salveson, UST Class A Operator
Sandi Frank, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
5105
Currently in Use
Gasoline
09
3/28/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
High Level Alarm
Yes
Not Applicable
5/7/2014
TLS-350/Gilbarco EMC , Veeder Root
3/28/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Fiberglass Reinforced Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
High Level Alarm
Yes
Not Applicable
5/11/2014
TLS-350/Gilbarco EMC , Veeder Root
3/28/2007
Fiberglass Reinforced Plastic
Double-Walled
Electronic Line Leak Detector
Automatic Tank Gauging 0.2, Continuous
Interstitial Monitor
Flexible Plastic
Double-Walled
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2, Continuous Interstitial Monitor, ELLD
Line Tightness Testing
High Level Alarm
Yes
Not Applicable
5/13/2014
TLS-350/Gilbarco EMC , Veeder Root
6,000
2
5106
Currently in Use
Diesel
09
6,000
3
5107
Currently in Use
Gasoline
09
12,000
Report Generation Date: 8/31/2016
Page 188
Facility Summary in YELLOWSTONE County in the City of WORDEN
Location:
Contact:
VALLEY FARMERS SUPPLY
1545 HIGHWAY 312
WORDEN, MT 59088
YELLOWSTONE
Ronald Broker, (406) 967-3100
Owners/Operators: Farmers Union Oil Co, Owner
Sys Fac ID: 56-02326
Last Inspected On: 12/2/2014
Operating Permit Renewal Date: 2/27/2018
(406)-967-3100
PO BOX 309
WORDEN MT 59088-0309
Scott Black, UST Class A Operator
Kirk Marzolf, UST Class A Operator
Scott Black, UST Class B Operator
Deborah Dvorak, UST Class B Operator
Tank Id
Tag Number
Status
Product
Capacity
Age
AST
Installed
Sump Tightness
Inventory Control
Tank/Pipe CP
Line Tightness
Tank Material of Construction
Secondary Option
Catastrophic L.D. Type 3.0
Tank Detection
ATG Type
Piping Material
Secondary Option
Piping Type
Primary Pipe Detection
Secondary Pipe Detection
Overfill Types
Spill Protected
CP Met Types
Vapor Recovery
Energy Act
1
24
11/1/1991
Steel Clad
Fiberglass Reinforced Plastic
9/16/2011
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
6/6/2011
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
11/1/1991
Steel Clad
Fiberglass Reinforced Plastic
1007
Currently in Use
Gasoline
9/16/2011
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
6,000
6/6/2011
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
11/1/1991
Steel Clad
Fiberglass Reinforced Plastic
1008
Currently in Use
Diesel
9/16/2011
None
Pressurized
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
3,000
6/6/2011
None
Electronic Line Leak Detector
Automatic Tank Gauging 0.1, Automatic Tank
Gauging 0.2
TLS-350/Gilbarco EMC , Veeder Root
1006
Currently in Use
Gasoline
6,000
2
3
24
24
Report Generation Date: 8/31/2016
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Flapper Valve (Auto
Shutoff)
Yes
Galvanic
Page 189
Fly UP