OVERVIEW OF LAS VEGAS VALLEY PERCHLORATE REMEDIAL EFFORTS
by user
Comments
Transcript
OVERVIEW OF LAS VEGAS VALLEY PERCHLORATE REMEDIAL EFFORTS
OVERVIEW OF LAS VEGAS VALLEY PERCHLORATE REMEDIAL EFFORTS Prepared for: Perchlorate Task Force Meeting Union Station, Los Angeles, California July 20, 2004 Todd Croft Nevada Division of Environmental Protection (702) 486-2871, [email protected] Perchlorate Manufacturing Operations Henderson, NV Pepcon (AMPAC): 1958 – 1988 • • US Government – Navy (1945 – 1962) Kerr-McGee & Predecessors (1945 – 1998) • • July 1998: Curtailed Perchlorate Production March 2002: Process Shut Down May 1988: Destroyed in Explosion March 1998: Purchased Manufacturing Line & Customer Base from Kerr-McGee Perchlorate Plumes & Remediation Infrastructure LAS VEGAS WASH SEEP SEEP AREA WELL FIELD WASH IX COH-RIB ATHENS ROAD WELL FIELD PABCO ROAD PIPELINE ON-SITE IX GW-11 POND DX WELLS & PILOT TESTING INTERCEPTOR SLURRY WALL & ON-SITE WELL FIELD KMCLLC PEPCON FBR SYSTEM 2002 1997 – – Initial Discovery – Source traced back to Las Vegas Wash – 1998 – – Plume Characterization On-Site Capture (Kerr-McGee) – Seep Capture (Kerr-McGee) – – 1999 Full-Scale Plant (ISEP-PDM): Construction Completed Start-up Initiated • Heat Exchanger Fouling • Reactor Pressure Spikes • Corrosion One-Pass IX System Replaces ISEP-PDM All Collection Points Operating (October 2002) 2003 – 2000 – – – Seep Area Characterization Pilot Plants Constructed ISEP-PDM Design Initiated – Full-Scale GW Treatment System (ISEPPDM) Constructed All Well Fields & Infrastructure Installed Permitting Finalized On-Site Slurry Wall Constructed – 2001 – – – 5 Additional Seep Area Wells Installed • Operating March 2003 • Compliments the 4 Existing Seep Area Wells Full-Scale Ex-Situ Fluidized Bed Reactor (FBR) Biological Treatment System • Will Replace ISEP-PDM & IX • Design, Permitting, & Construction Initiated 2004 – FBR Full-Scale Operation Planned by Summer 2004 On-Site IX Perchlorate Remedial Systems Full-Scale GW Treatment System Current Recent Past Capture & Treatment Wash IX: ~ 300 gpm @ ~ 30 - 120 ppm • Seep Area Collection On-Site IX: ~ 700 gpm @ ~ 200 - 300 ppm • Athens Road • Seep Area Collection • On-Site Pond with Return Flow Full-Scale System: ~ 850 - 1,000 gpm @ ~ 250 ppm • • • • Athens Road Well Field On-Site Pond On-Site Well Field Seep Area Collection - GW & Surface Perchlorate Removal Rate: June 2004 Location Perchlorate Removed from the Environment: Through June 2004 Mass (Pounds per Day) Location Mass (Tons) Seep Area 156 Seep Area 312 Athens Road 757 Athens Road 265 706 On-Site 1,044 On-Site Total 1,957 Total 1,283 AMPAC Pilot: Biodegradation of Perchlorate • Flow Rate - 10 GPM • Approximately 600 ppm perchlorate near source area • Carbon Source – Ethanol/Citric Acid/Potassium Oleate • Bio-fouling Control – Ultrasonic/Citric Acid/ Chlorine Dioxide • Degraded ~ 600 ppm to < 2ppb in approximately 110 days • Evaluated Several Electron Donors • Corrected Chemical and Biological Fouling Issues Conceptual Model of Perchlorate Loading to the Las Vegas Wash Prior To October 2002 Capture and Treatment Northshore Road LM2 Existing Upstream Flow 10 lbs/day LM8 LM6 200 lbs/day 500 lbs/day Kerr-McGee Treatment 400 lbs/day Wash Flow S E E P Athens Road y /da bs l 0 50 Groundwater Discharge to Wash 250 to 300 lbs/day Horse Spring Formation Extraction Wells leo a P 00 9 ay /d lbs Wash Gravels el n n a Ch Former Complex Loading Fault Slurry Cutoff Wall 500 lbs/day Breakthrough Curve: 90% Efficient Model Results, Mass 1000 900 P e rc h lo ra te M a s s F lu x (lb s /d a y ) Lower 95% Confidence Median Higher 95% Confidence October 2002 ~ 420 - 580 lbs/day 800 Northshore Rd Expon. (Northshore Rd) 700 600 500 October 2004 ~ 80 - 120 lbs/day 400 300 200 October 2003 ~ 150 - 300 lbs/day 100 0 0 1 2 Time (Years) 3 4 Predicted Perchlorate at Whitsett Intake* Medium Lake Mead Storage Condition Perchlorate (ppb) 10 Original Projection 8 Revised Projection (90% capture at Athens Rd.) 6 4 2 0 '04 '05 '06 '07 '08 Year *Provided by Metropolitan Water District and Flow Science '09 '10 Perchlorate Concentration Perchlorate Detection Limit Specific Conductance Jan-05 Oct-04 Jul-04 Apr-04 Jan-04 Oct-03 Jul-03 Apr-03 Jan-03 Oct-02 Jul-02 Apr-02 Jan-02 Oct-01 Jul-01 Apr-01 Jan-01 Oct-00 Jul-00 Apr-00 Jan-00 Oct-99 Jul-99 Apr-99 Jan-99 Perchlorate Concentration ( µ g/L) 20.0 1200 18.0 1080 16.0 960 14.0 840 12.0 720 10.0 600 8.0 480 6.0 360 4.0 240 2.0 120 0.0 0 Specific Conductance ( µ S/cm) Willow Beach Sampling Point Perchlorate Concentration (µg/L) On-Going Activities Entities Involved • Investigation of LV Wash & BMI Areas to Evaluate Other Potential Perchlorate Sources • US Environmental Protection Agency • NV Division of Environmental Protection • Southern Nevada Water Authority • Metropolitan Water District • City of Henderson • Kerr-McGee • AMPAC • BMI • Continued Evaluation of Remedial Technologies • Consideration of Opportunities to Further Refine Capture & Treatment