(Please see Appendix CD for additional documents) Documents
by user
Comments
Transcript
(Please see Appendix CD for additional documents) Documents
Greater Los Angeles County Region Attachment 3 Work Plan Appendix 3-G: Pacoima Spreading Grounds Improvements Supporting Documents (Please see Appendix CD for additional documents) IRWM Implementation Grant Proposal Proposition 84, Round 2 March 2013 This page intentionally left blank. April 6, 2011 Approved Diego Cadena TO: Diego Cadena FROM: Christopher Stone Water Resources Division PACOIMA SPREADING GROUNDS PROJECT CONCEPT REPORT Recommendations 1. Approve the attached project concept report for the Pacoima Spreading Grounds Improvements Project. 2. Authorize Water Resources Division (WRD) to pursue project funding opportunities with interested stakeholders. 3. Authorize Design Division to complete final design plans and specifications in Fiscal Year (FY) 2011-12. 4. Authorize Watershed Management Division (WMD) (Flood Programs) to allocate: a. $200,000 for the project's environmental contract. ;2_A M ? Tu YeAR-5 5. Authorize WRD to pursue the environmental document required for the project. Discussion Pacoima Spreading Grounds has insufficient storage capacity, low percolation rates, and intake restrictions during high flow conditions. The proposed spreading grounds improvements will reconfigure the basins to provide increased storage capacity, while removing clay to increase percolation rates. The project consists of improving the existing intake structure by replacing the intake canal with four 54-inch diameter reinforced concrete pipes. The area will be backfilled to create an area for future recreational or habitat enhancement opportunities. The radial gate will be replaced with a rubber dam. The improved intake will convey an intake flow rate of 600 cubic feet per second (cfs) even under high flow conditions and eliminate flooding problems at Arleta Avenue. The recharge basins will be reconfigured and deepened. The shallow clay layer in the upper 12 to 24 feet of the subsurface will be removed to improve percolation and Diego Cadena April 6, 2011 Page 2 increase storage capacity. Estimated removal depths for each basin are based on recommendations reported in the January 2009 Geological Investigation Report completed by Geotechnical and Materials Engineering Division, but field conditions will be used to determine the final removal limits. Approximately 1,370,000 cubic yards of excavated material will be removed from the site. The material will be sent to the nearby Vulcan Materials Co. processing site or trucked to an alternative location. The proposed improvements will increase the storage capacity of the grounds from 530 to 1,197 acre-feet (AF) by deepening and combining basins. Operational efficiency will be enhanced with the proposed interbasin structures and facility layout. The percolation is expected to increase from 65 to 142 cfs as a result of the clay removal. The improvements are estimated to conserve an additional 10,500 AF of water per wet year. Department of Water and Power (DWP) has expressed an interest in improvements to Pacoima Spreading Grounds. Upon approval of this concept we will meet with DWP to discuss the approved concept and to explore cost sharing opportunities. WMD and Flood Maintenance Division have reviewed the concept and we have incorporated their comments. If you have any questions, please contact Ken Zimmer at Extension 6188. OZ:vt ,ie P: \wrd \WATER CONSERVATIONTROJECTS\Current\PacoimaTinal Memo to Diego.docx Attach. cc: Design Flood Maintenance (Vander Vis) Watershed Management March 28, 2011 Approved Chri opher Stone TO: Christopher Stone FROM: Ken Zimmer Water Conservation Planning Section PACOIMA SPREADING GROUNDS PROJECT CONCEPT REPORT Background Pacoima Spreading Grounds is located in the City of Los Angeles near the intersection of Paxton and Arleta Streets on the west side of Pacoima Diversion Channel. The facility consists of 12 large shallow basins and has a storage capacity of 530 acre-feet (AF). The facility is one of the major water conservation facilities that recharge the San Fernando Basin. The water conserved at Pacoima Spreading Grounds is supplied by storm flows and controlled releases from Pacoima Dam, partially controlled flow from Lopez Basin, and uncontrolled flows from East Canyon and Pacoima Wash. Water is diverted from Pacoima Wash into the spreading grounds utilizing a radial gate, and then the water flows through the intake canal to the spreading basins. The facility's percolation is limited due to clay-rich lenses with low permeability that underlie the recharge area. The intake to the spreading grounds is limited to 600 cubic feet per second (cfs) since higher flows cause the intake canal to overflow, which causes flooding on Arleta Street. Channel flows in Pacoima Wash frequently exceed the radial gate's limited operating capacity of 1,700 cfs. When this occurs, diversion to the spreading grounds is suspended since the radial gate must be removed from the channel invert, allowing water to be wasted to the ocean. Additional maintenance and operational difficulties exist at the facility. A Department of Water and Power (DWP) 72-inch diameter water main, runs across the lower basins and has been previously damaged during spreading grounds maintenance activities. Also, flow is limited to the western basins south of Devonshire Street because the culverts cannot convey the design intake flow. Proposed Spreading Grounds Improvements The proposed improvements will increase the storage capacity and simplify operations by combining basins and constructing new interbasin structures. The radial gate will be replaced with a rubber dam that can operate during higher flows. Different options to Christopher Stone March 28, 2011 Page 2 upgrade the intake structure have resulted in the following three alternatives for this project: Alternative A - Modify Existing Intake and Remove Clay Alternative B - Build New Intake at Different Location and Remove Clay Alternative C — No Change to Existing Intake, Remove Clay Intake Upgrade Modify Existing Intake — Alternative A Alternative A consists of improving the existing intake structure by replacing the intake canal with four 54-inch diameter reinforced concrete pipes (RCP). The area will be backfilled to create an area for future recreational or habitat enhancement opportunities. The radial gate will be replaced with a rubber dam. The improved intake will convey an intake flow rate of 600 cfs and eliminate flooding at Arleta Avenue. The recharge basins will be reconfigured and deepened. Build New Intake at Different Location — Alternative B Alternative B consists of constructing a new intake structure located at the southeast corner of Arleta Avenue and Paxton Street. An air-inflatable rubber dam will be installed in Pacoima Diversion Channel at the new location, the radial gate and old Headworks Structure will be removed, the settling basin will be reconstructed, and recharge basins will be reconfigured and deepened. The parcel that is proposed for the new Headworks location is privately owned and an easement will need to be acquired, or the parcel will need to be purchased outright. No Change to Existing Intake — Alternative C Alternative C consists of leaving the existing intake operational. This option would save $1,400,000 of the capital costs but would reduce the water conservation benefit. Percolation Improvement Clay Removal For both alternatives the shallow clay layer in the upper 12 to 24 feet of the subsurface Christopher Stone March 28, 2011 Page 3 will be removed to improve percolation and increase storage capacity. Estimated removal depths for each basin are based on recommendations reported in the January 2009 Geological Investigation Report completed by Geotechnical and Materials Engineering Division, but field conditions will determine the final removal depths. Approximately 1,370,000 cubic yards (CY) of excavated material will be removed from the site. The material will be sent to the nearby Vulcan Materials Co. processing site or trucked to an alternative location. Storage Improvement Alternative A — Storage capacity will increase by approximately 667 AF. Alternative B — Storage capacity will increase by approximately 692 AF. Alternative C — Storage capacity will increase by approximately 667 AF. Alternatives The alternatives along with their respective estimated costs and benefits during a high rainfall year are listed in the following table. Alternative Descri tion Estimated Cost Wet Year Benefit A Modify existing intake, remove clay layers. $28,068,000 $5,160,300 B Build new intake, remove clay layers. $28,282,600* $5,124,700 C No change to existing intake, remove clay layers. $26,600,000 $5,039,000 * plus cost to acquire Ian Recommendation The proposed alternative A will increase the storage capacity of the grounds from 530 to 1,197 AF by deepening and combining basins. Operational efficiency will be enhanced Christopher Stone March 28, 2011 Page 4 with the new interbasin structures and facility layout. The percolation is expected to increase from 65 to 142 cfs as a result of the clay removal. The improvements are estimated to conserve an additional 10,500 AF of water per wet year. DWP has expressed an interest in improvements to Pacoima Spreading Grounds. We will meet with DWP to discuss the approved concept and to explore cost sharing opportunities. MG:vt P:\wrd\WATER CONSERVATIONTROJECTS \Current\Pacoima Writeup.docx Attach. April 6, 2011 Approved Diego Cadena TO: Diego Cadena FROM: Christopher Stone Water Resources Division PACOIMA SPREADING GROUNDS PROJECT CONCEPT REPORT Recommendations 1. Approve the attached project concept report for the Pacoima Spreading Grounds Improvements Project. 2. Authorize Water Resources Division (WRD) to pursue project funding opportunities with interested stakeholders. 3. Authorize Design Division to complete final design plans and specifications in Fiscal Year (FY) 2011-12. 4. Authorize Watershed Management Division (WMD) (Flood Programs) to allocate: a. $200,000 for the project's environmental contract. ;2_A M ? Tu YeAR-5 5. Authorize WRD to pursue the environmental document required for the project. Discussion Pacoima Spreading Grounds has insufficient storage capacity, low percolation rates, and intake restrictions during high flow conditions. The proposed spreading grounds improvements will reconfigure the basins to provide increased storage capacity, while removing clay to increase percolation rates. The project consists of improving the existing intake structure by replacing the intake canal with four 54-inch diameter reinforced concrete pipes. The area will be backfilled to create an area for future recreational or habitat enhancement opportunities. The radial gate will be replaced with a rubber dam. The improved intake will convey an intake flow rate of 600 cubic feet per second (cfs) even under high flow conditions and eliminate flooding problems at Arleta Avenue. The recharge basins will be reconfigured and deepened. The shallow clay layer in the upper 12 to 24 feet of the subsurface will be removed to improve percolation and Diego Cadena April 6, 2011 Page 2 increase storage capacity. Estimated removal depths for each basin are based on recommendations reported in the January 2009 Geological Investigation Report completed by Geotechnical and Materials Engineering Division, but field conditions will be used to determine the final removal limits. Approximately 1,370,000 cubic yards of excavated material will be removed from the site. The material will be sent to the nearby Vulcan Materials Co. processing site or trucked to an alternative location. The proposed improvements will increase the storage capacity of the grounds from 530 to 1,197 acre-feet (AF) by deepening and combining basins. Operational efficiency will be enhanced with the proposed interbasin structures and facility layout. The percolation is expected to increase from 65 to 142 cfs as a result of the clay removal. The improvements are estimated to conserve an additional 10,500 AF of water per wet year. Department of Water and Power (DWP) has expressed an interest in improvements to Pacoima Spreading Grounds. Upon approval of this concept we will meet with DWP to discuss the approved concept and to explore cost sharing opportunities. WMD and Flood Maintenance Division have reviewed the concept and we have incorporated their comments. If you have any questions, please contact Ken Zimmer at Extension 6188. OZ:vt ,ie P: \wrd \WATER CONSERVATIONTROJECTS\Current\PacoimaTinal Memo to Diego.docx Attach. cc: Design Flood Maintenance (Vander Vis) Watershed Management March 28, 2011 Approved Chri opher Stone TO: Christopher Stone FROM: Ken Zimmer Water Conservation Planning Section PACOIMA SPREADING GROUNDS PROJECT CONCEPT REPORT Background Pacoima Spreading Grounds is located in the City of Los Angeles near the intersection of Paxton and Arleta Streets on the west side of Pacoima Diversion Channel. The facility consists of 12 large shallow basins and has a storage capacity of 530 acre-feet (AF). The facility is one of the major water conservation facilities that recharge the San Fernando Basin. The water conserved at Pacoima Spreading Grounds is supplied by storm flows and controlled releases from Pacoima Dam, partially controlled flow from Lopez Basin, and uncontrolled flows from East Canyon and Pacoima Wash. Water is diverted from Pacoima Wash into the spreading grounds utilizing a radial gate, and then the water flows through the intake canal to the spreading basins. The facility's percolation is limited due to clay-rich lenses with low permeability that underlie the recharge area. The intake to the spreading grounds is limited to 600 cubic feet per second (cfs) since higher flows cause the intake canal to overflow, which causes flooding on Arleta Street. Channel flows in Pacoima Wash frequently exceed the radial gate's limited operating capacity of 1,700 cfs. When this occurs, diversion to the spreading grounds is suspended since the radial gate must be removed from the channel invert, allowing water to be wasted to the ocean. Additional maintenance and operational difficulties exist at the facility. A Department of Water and Power (DWP) 72-inch diameter water main, runs across the lower basins and has been previously damaged during spreading grounds maintenance activities. Also, flow is limited to the western basins south of Devonshire Street because the culverts cannot convey the design intake flow. Proposed Spreading Grounds Improvements The proposed improvements will increase the storage capacity and simplify operations by combining basins and constructing new interbasin structures. The radial gate will be replaced with a rubber dam that can operate during higher flows. Different options to Christopher Stone March 28, 2011 Page 2 upgrade the intake structure have resulted in the following three alternatives for this project: Alternative A - Modify Existing Intake and Remove Clay Alternative B - Build New Intake at Different Location and Remove Clay Alternative C — No Change to Existing Intake, Remove Clay Intake Upgrade Modify Existing Intake — Alternative A Alternative A consists of improving the existing intake structure by replacing the intake canal with four 54-inch diameter reinforced concrete pipes (RCP). The area will be backfilled to create an area for future recreational or habitat enhancement opportunities. The radial gate will be replaced with a rubber dam. The improved intake will convey an intake flow rate of 600 cfs and eliminate flooding at Arleta Avenue. The recharge basins will be reconfigured and deepened. Build New Intake at Different Location — Alternative B Alternative B consists of constructing a new intake structure located at the southeast corner of Arleta Avenue and Paxton Street. An air-inflatable rubber dam will be installed in Pacoima Diversion Channel at the new location, the radial gate and old Headworks Structure will be removed, the settling basin will be reconstructed, and recharge basins will be reconfigured and deepened. The parcel that is proposed for the new Headworks location is privately owned and an easement will need to be acquired, or the parcel will need to be purchased outright. No Change to Existing Intake — Alternative C Alternative C consists of leaving the existing intake operational. This option would save $1,400,000 of the capital costs but would reduce the water conservation benefit. Percolation Improvement Clay Removal For both alternatives the shallow clay layer in the upper 12 to 24 feet of the subsurface Christopher Stone March 28, 2011 Page 3 will be removed to improve percolation and increase storage capacity. Estimated removal depths for each basin are based on recommendations reported in the January 2009 Geological Investigation Report completed by Geotechnical and Materials Engineering Division, but field conditions will determine the final removal depths. Approximately 1,370,000 cubic yards (CY) of excavated material will be removed from the site. The material will be sent to the nearby Vulcan Materials Co. processing site or trucked to an alternative location. Storage Improvement Alternative A — Storage capacity will increase by approximately 667 AF. Alternative B — Storage capacity will increase by approximately 692 AF. Alternative C — Storage capacity will increase by approximately 667 AF. Alternatives The alternatives along with their respective estimated costs and benefits during a high rainfall year are listed in the following table. Alternative Descri tion Estimated Cost Wet Year Benefit A Modify existing intake, remove clay layers. $28,068,000 $5,160,300 B Build new intake, remove clay layers. $28,282,600* $5,124,700 C No change to existing intake, remove clay layers. $26,600,000 $5,039,000 * plus cost to acquire Ian Recommendation The proposed alternative A will increase the storage capacity of the grounds from 530 to 1,197 AF by deepening and combining basins. Operational efficiency will be enhanced Christopher Stone March 28, 2011 Page 4 with the new interbasin structures and facility layout. The percolation is expected to increase from 65 to 142 cfs as a result of the clay removal. The improvements are estimated to conserve an additional 10,500 AF of water per wet year. DWP has expressed an interest in improvements to Pacoima Spreading Grounds. We will meet with DWP to discuss the approved concept and to explore cost sharing opportunities. MG:vt P:\wrd\WATER CONSERVATIONTROJECTS \Current\Pacoima Writeup.docx Attach. SUBSURFACE INVESTIGATION PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS CITY OF LOS ANGELES, CALIFORNIA September 2007 }aEa~v flEOIAtlW dEDLOGY ~d - W a ~ 0 lirEO~ECII~I~A~L AI~T~ IV~.A~TERIALS ' ! # o ~.'• y -~ ~rA .., ~; w_;.~w ;_;.z $' -~ °w -~--1— g o— i ~"nEOL~QCY ~a~l}LOGY GFALCKaYi SUBSURFACE INVESTIGATION PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS CITY OF LOS ANGELES, CALIFORNIA Prepared for County of Los Angeles Department of Public Works Water Resources Division Prepared by County of Los Angeles Department of Public Works Geotechnical and Materials Engineering Division Geology Investigations Section September 12, 2007 TABLE OF CONTENTS 1.0 INTRODUCTION ..................................................................................................1 1.1 PURPOSE..................................................................................................1 SCOPE OF SERVICES..............................................................................1 1.2 1.3 SITE PLAN .................................................................................................1 2.0 SITE DESCRIPTION .............................................................................................2 3.0 PHYSICAL SETTING ............................................................................................2 3.1 SITE CONDITIONS ....................................................................................2 3.2 GEOLOGIC SETTING ................................................................................3 3.3 HYDROGEOLOGIC SETTING ..................................................................3 4.0 FIELD WORK ........................................................................................................3 4.1 RECONNAISSANCE ..................................................................................3 4.2 SUBSURFACE EXPLORATION ................................................................4 5.0 FINDINGS .............................................................................................................4 6.0 CONCLUSIONS....................................................................................................5 7.0 REFERENCES......................................................................................................6 FIGURES FIGURE 1 -SITE LOCATION MAP FIGURE 2 -SITE PLAN FIGURE 3-CROSS SECTION A-A' FIGURE 4 -CROSS SECTION B-B' FIGURE 5 -CROSS SECTION C-C' APPENDIX A - PACOIMA SPREADING GROUNDS IMPROVEMENTS REQUEST FOR SUBSURFACE INVESTIGATION REPORT, MARCH 5, 2007 APPENDIX B SUMMARY OF LOG OF BORINGS Geotechnica!and 1L9aterials En r~ou Geology •Soils •Materials Testing Subsurface Investigation Pacoima Spreading Grounds September 12, 2007 Page 1 1.0 INTRODUCTION A subsurface investigation for determining the lateral and vertical limits of a large clayrich bed was performed for the Pacoima Spreading Grounds as requested in your March 5, 2007, memo (Appendix A). The site consists of 12 basins and associated levees located on approximately 150 acres southwest and northwest of the intersection of Devonshire Street and Arleta Avenue in the communities of Arleta and Mission Hills in the City of Los Angeles (Figure 1). 1.1 PURPOSE The main objective of this subsurface investigation was to locate and identify the limits of anear-surface clay-rich soil layer by drilling ten boreholes within the subject site. The results of this investigation and our conclusions are provided in this report. 1.2 SCOPE OF SERVICES To achieve the project objectives, the following scope of services was provided: • Performing site reconnaissance. • Reviewing selected geologic reports and maps. • Drilling and logging ten boreholes. • Preparing this report which presents our findings and conclusions. 1.3 SITE PLAN The site map supplied by your Division consists of a scanned composite plan at the approximate scale of 1 inch equals 120 feet. This plan was utilized during fieldwork and the geotechnical cross-sections were prepared using this map as the base. However, the format of this map was not conducive to computer drafting systems and is not included in this report. The Site Plan (Figure 2) was prepared utilizing a schematic of the Pacoima Spreading Grounds and is presented at the approximate scale of 1 inch equals 480 feet. Owing to the scale of the site plan, the geologic contact separating artificial fill from Quaternary alluvium cannot be shown in the detail provided on the geologic cross sections. Geotechnical and Materials En Division rues~i Geology • Sorls • Materials Testing Subsurface Investigation Pacoima Spreading Grounds September 12, 2007 Page 2 In general, the levees and streets are underlain by 2 to 16 feet of artificial fill and the basins bottoms are underlain by Quaternary alluvium. 2.0 SITE DESCRIPTION The site is an irregularly shaped parcel that consists of approximately 150 acres located adjacent to and southwest and northwest of the intersection of Arleta Avenue and Devonshire Street in the Arleta and Mission Hills communities of the City of Los Angeles in the north-central San Fernando Valley. The site is located within a portion of Sections 15 and 16, Township 2 North, Range 15 West of the U.S. Geological Survey San Fernando Quadrangle (7.5-Minute Series). The site is operated by your Division as an infiltration/groundwater recharge facility. The facility consists of 12 basins separated by a series of levees. The facility is bounded by Arleta Avenue, Filmore Street, Woodman Avenue, residential properties, and Devonwood Park. Devonshire Street bisects the site into northerly and southerly sections. Service roadways within the facility are located on the levees; ramps from the roads provide access to the basins. Other improvements onsite include aboveground and belowground utilities that cross the central portion of the site. The surrounding area consists of residential structures and the accompanying streets located adjacent to the site on the north, west, southwest, and southeast. A park is located adjacent to the west-central portion of the site and spreading ground facilities are located offsite on the north side of Arleta Avenue. The Pacoima Diversion Canal is located to the northeast of the site and the Pacoima Wash Channel is located to the south of the site. 3.0 PHYSICAL SETTING 3.1 SITE CONDITIONS The site is located in the north-central San Fernando Valley south of the San Gabriel Mountains at elevations ranging from 948 feet to 901 feet above mean sea level. Overall, the site slopes gently to the south; however, as the site consists of basins and levees, the natural grades and gradients have been modified to impound water and to move water in a controlled manner from one end of the site to the other. The basins have been excavated below native grade and the levees have been constructed above natural adjacent grade along the perimeter of the site. Vegetation consists of grasses and brush in the basins and on the levees. Various trees are located on the levees along the perimeter of the site. Geotechnica!and Materials Enpineerirtq Division • Soils •Maier+als Testing Subsurface Investigation Pacoima Spreading Grounds September 12, 2007 Page 3 3.2 GEOLOGIC SETTINGS The site is located within the San Fernando Valley, which is an east-west trending basin within the Transverse Ranges geologic/geomorphic province. Overtime, the basin has subsided and been infilled with alluvial material as the mountains bounding the valley/basin have uplifted along underlying thrust-fault systems. This portion of the basin has infilled with sediments derived from the crystalline bedrock of the San Gabriel Mountains and received from the Pacoima Wash and Tujunga Wash drainage systems. The sediments include sand, silt, and gravel of granitic origin, and clays that have formed during the weathering process. The onsite geologic units include artificial fill (af) and Quaternary alluvium (Qal). The artificial fill consists of sand, silt, gravel, and clay that apparently was excavated from the basin areas and used to construct the levees. The levees vary in height from approximately 8 feet to 16 feet above the bottoms of the adjacent basins. The Quaternary alluvium consists of sand, silt, gravel, and clay deposited in stream channel and/or floodplain environments. 3.3 HYDROGEOLOGIC SETTING The site is located in the San Fernando hydrologic subarea of the upper Los Angeles River groundwater basin. Fresh water is typically found at a depth of several hundred feet in loose to partially consolidated, coarse to very coarse, alluvial deposits in the eastern portion of the San Fernando hydrologic subarea. Data for nearby wells (within two miles) provided by the State of California and the County of Los Angeles indicate that the historic high groundwater levels in the subject area are greater than 200 feet below the ground surface. 4.0 FIELDWORK 4.1 RECONNAISSANCE On April 10, 2007, Geotechnical and Materials Engineering Division (GMED) performed a site reconnaissance with contract driller, Boart Longyear, and Flood Maintenance Division. No concerns were observed that would significantly limit the field investigation. Subsurface Investigation Pacoima Spreading Grounds September 12, 2007 Paae 4 SUBSURFACE EXPLORATION Subsurface exploration was performed from May 21 through 23, 2007. Ten borings (B1 through B10) were drilled, utilizing a sonic drill rig provided by Boart Longyear, to depths ranging from 27 feet to 57 feet (Summary Log of Borings are provided in Appendix B). The approximate locations of the borings are shown on Figure 2. The sonic drill rig drilled approximately 8-inch-diameter borings and allowed for the collection of nearly continuous, disturbed core samples. The core samples were then inspected and logged by GMED personnel. At the completion of drilling, each boring was backfilled with clean, bagged Monterey Sand. Soil cuttings from each boring were manually spread within the basin in the vicinity of each boring. The clay-rich bed was initially observed during the 2006 Fugro West, Inc., investigation. (References). During the 2006 study, the clay-rich bed was observed only in the northern-most borings along the margins of the Pacoima Spreading Grounds. Figure 2 shows the location of the Fugro West Borings. For the current investigation, the boring locations were chosen to determine if the clay-rich bed was continuous and extended beneath the basins. As the clay-rich bed was encountered during this study, additional boring locations were chosen to delineate the southerly and westerly limits of the bed. 5.0 FINDINGS • The alluvium observed underlying the Pacoima Spreading Grounds is predominantly a combination of sand, silt, and gravel. Additionally, a relatively continuous clay-rich bed was encountered in Borings B-1 through B-5, B-7, B-9, and B-10. • The clay-rich bed varied in thickness from 3 feet in Boring B-10 to 10 feet in Boring B-5. The bed appears to dip to the south-southwest and is approximately located on the Site Plan (Figure 2) and the geologic cross sections (Figures 3, 4, and 5). This bed appears to underlie all of Basins 1, 6 through 11, and portions of Basins 2 through 5, and 12. The depth to the top of the clay-rich bed, below the bottoms of the affected basins, varies from 5 to 15 feet. The maximum anticipated depth to the bottom of the continuous clay-rich bed is 19 feet below the bottom of Basin 11. • Additional clay-rich beds were observed in several borings. However, these beds appear to be significantly thinner, generally less than 3 feet thick. These clay-rich beds were observed at widely varying depths and are anticipated to be less continuous than the above-described clay bed. Geotechnical and Materials Engineering Division Geology •Soils •Materials Testing Subsurface Investigation Pacoima Spreading Grounds • September 12, 2007 Pape 5 Static groundwater was not observed in the 10 borings drilled for this investigation (to a maximum depth of 51 feet below the bottom of Basin 2). However, zones of perched groundwater were observed in Borings B-2, B-6, B-7, and B-8 at depths ranging from 16 feet to 44.5 feet below the top of the boring. These perched conditions generally occurred above less permeable clay-rich zones. Groundwater levels onsite are anticipated to vary widely as a result of recharge, precipitation, and irrigation. 6.0 CONCLUSIONS The shallow subsurface investigation has shown that a continuous clay-rich bed underlies much of the Pacoima Spreading Grounds. This bed is anticipated to limit the vertical infiltration of recharge water placed in the affected basins. Based on the perched groundwater observed in Borings B-2 and B-6 through B-8, the thinner clay-rich beds also appear to limit the vertical infiltration of recharge water. However, as these clay-rich beds appear to be laterally discontinuous, it is anticipated that recharge water moves along the clay bed until a path for downward infiltration is found. Additional clay-rich beds may exist below the depths explored during this investigation which may yet impede infiltration rates. Removal of the continuous clay-rich bed underlying all of Basins 1, 6 through 11, and portions of Basins 2 through 5, and 12 and replacement with a more permeable (and better sorted) coarse-grained material as planned by your Division, is expected to improve the infiltration characteristics of the Pacoima Spreading Grounds. This subsurface investigation report was prepared, reviewed, and/or submitted by the undersigned geologists. If you have any questions regarding this matter, please contact Clayton Masters at (626)458-4923. Prepared by: Reviewed and submitted by: Clayton R. Masters Engineering Geologist P.G. 4943, C.E.G. 1636 erald Goodman Engineering Geologist P.G. 7094, C.E.G. 2227, C.HG. 777 CM:af~P:GMEDISEC\GEOINV\RPTS\PACOIMASG Geotechnica!and Materials En Division Geology •Soils •Materials Testing Please complete a Customer Service Survey at http://dpw.lacounty.gov/go/gmedsurvey. YUtlLI~ Subsurface Investigation Pacoima Spreading Grounds September 12, 2007 Page 6 7.0 REFERENCES California Department of Conservation, Division of Mines and Geology, 1969; Geologic Map of California Los Angeles Sheet, Scale 1:250,000. California Department of Conservation, Division of Mines and Geology, 1975; San Fernando, California; Earthquake of 9 February 1971; Gordon B. Oakeshott, editor; Bulletin 196. California Department of Conservation, Division of Mines and Geology, 1997; Seismic Hazard Zone Report for the Van Nuys 7.5-minute Quadrangle; Los Angeles County, California; Seismic Hazard Zone Report 008, revised 2001. California Department of Conservation, Division of Mines and Geology, 1998; Seismic Hazard Evaluation of the San Fernando 7.5-Minute Quadrangle; Los Angeles County, California; Open-File Report 98-06. California Department of Conservation, Division of Mines and Geology, 2000; Quaternary Geology of the San Fernando Valley; Los Angeles County, California; Map Sheet 50. Dibblee, Thomas W. Jr., 1991; Geologic Map of the San Fernando and Van Nuys (North'/2) Quadrangles; Los Angeles County, California, DF-33. Fugro West, Inc., 2006; Geotechnical Study Levee Evaluation Pacoima Spreading Grounds Woodman Avenue and Fillmore Street, Los Angeles County, California; prepared for County of Los Angeles, dated October 12, 2006, Fugro Project No. 3009.015. U.S. Geological Survey, 1900, San Fernando Quadrangle 15-minute series, reprinted 1930. U.S. Geological Survey, 1927, Pacoima Quadrangle 6-minute series, reprinted 1939. U.S. Geological Survey, 1966, San Fernando Quadrangle 7.5-minute series, photo-revised 1972. Division ruesuc; w~rzres Geology •Soils• Materials Testing FIGURES .?-• Sun. €C~ga1~u f /~,~ (/ 1. l < .,T •~~ 3 ~ t *~i ~ _'Z.. _ r. e Std _,_ 'l~ranA. `~ ~i 95c ~~'.~. _ ~ s~~ p mark g~NO~'~. ~ ~~ irailftr ~ ~ ~ ~ li ; 5: ~m 7 a ~tt"'!J k/ '~, ~t1 ~ ~. I ~ • ~ 4'4. ~,_ ',_ ~.,,s:.~~ ~~~!~.'~ll,~ ~.~~~ 'l qtr iii 1 $fit i.x~ g`ia i nje J 1~ .013 HI~~$ i 909 __sue ~r~ E i 9t I ~ a.._..S. ~.~-. 4 l_ n _ ~ ~ ,; .~; 4 ~, ~ Le]gen ~ i~~h _ ~ ~. i ! _ ` / ~ 4 I,t M `: ~ Q '' :o d6I ~~~ ~ihs !' ~ SCII m~ TVOFER~. --, 0 TN*IMhI ,5 1 Y111E ~rJ ~~.70FEE1 0 {13%° ~ ~ .egg `' 1 FCA ~ _ ` ~ ..f. ~ .~. ~ ~ t c4.,.~.,_ ived~ Y iury Srh 116 ` ~^ Jr ~ ~- ,;a ~ ~- 4 ~~ ° ..~su s _ --- - Site -T r TERA:~S~ ITAL .914 ~ 1~ 1 ~ ST ~ W Y;t ~ ~x L~'s~~ ~ `°• ,: ' .,~~, `' ' BM 1 ~ •.~ ? a _~,v~ ?4~'Ph"f1Ct~S PNIapcreated with TOPO!~ f~2003 National Geo~aphic(www.nationa~geographic.cornitopo) GEOLOGY GEOLOGY GEOLOGY o ~ W " o . Illi_ ~~ o Geology Investigations Unit m ,.~,~illl~~~ o ~I`I`~ \II~/~ `~dll~i~ ~~~iini_~°' ~IIII =~ ~—~% ~— o LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS Geotechnical and Materials Engineering Division SITE LOCATION MAP ~ ~ PACOIMA SPREADING GROUNDS _ O ARLETAAND MISSION HILLS, CITY OF LOS ANGELES, CALIFORNIA ~o GEOLOGY GEOLOGY GEOLOGY PREPARED BY: Eddie Ly DATE: August 2007 SCALE: 1" = 2000' FIGURE 1 J B-~o ~ EXPLORATORY BORING PUBLIC WORKS MAY 2007 LEGEND P-9 480' 960' APPROXIMATE LIMITS OF THICK (>3') CLAY-RICH BED, QUERRIED WHERE UNCERTAIN. LOCATION OF GEOLOGIC CROSS-SECTION EXPLORATORY BORING - FUGRO WEST, INC., INVESTIGATION DATED OCTOBER 12, 2006 ~ i , t t_1 ~ ~ 240' SCALE APPROXIMATELY: 1 INCH = 480 FEET .~~~1 ~ 0' LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOTECHNICAL AND MATERIALS ENGINEERING DIVISION GEOLOGY INVESTIGATIONS UNIT DATE: AUGUST 2007 SCALE AS SHOWN FIGURE 2 SITE PLAN PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS, CITY OF LOS ANGELES, CALIFORNIA PREPARED BY: EDDIE LY NOTE: THE GEOLOGIC CROSS-SECTIONS WERE PREPARED UTILIZING A NON-REPRODUCIBLE FIELD MAP(SCALE 1" = 120') SUPPLIED BY WATER RESOURCES DIVISION. MINOR LOCATION DISCREPANCIES MAY BE NOTED BETWEEN THE GEOLOGIC CROSS-SECTION AND FIGURE 2 THE SITE PLAN SUPPLIED IN THIS REPORT. :~~ 840' 920' •.~ N 25°W -10 )'E) BASIN 11 Qai `—'--= ~ -? --- _? ?_ ---_- of BORING B-5 (PROJ. 50'V~ DEVONSHIRE STREET - FUGRO BORING P-7 (PROJ. 310'N1~ 800' 840' ::~ 920' •.~ 1000' 0' 60' 120' 240' EDDIE LY PREPARED BY: I DATE: AUGUST 2007 SCALE AS SHOWN FIGURE 3 CROSS SECTION A-A' PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS, CITY OF LOS ANGELES, CALIFORNIA GEOLOGY INVESTIGATIONS UNIT LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOTECHNICAL AND MATERIALS ENGINEERING DIVISION 0 N 0 SCALE: HORIZONTAL SCALE 1" = 120'(APPROXIMATE) VERTICAL SCALE 1" = 40' THIN(<3' THICK) CLAY-RICH BED CLAY BED _= —~—o-- SILT BED ~^~~ GEOLOGIC CONTACT, QUERRIED WHERE UNCERTAIN QUATERNARY ALLUVIUM Qai ?— ~ ~ ~ ~ ARTIFICIAL FILL of EXPLANATION :~~ 840' 920' ~.~ 1000' N 24°W :~~ 840' ::~ 920' •.~ 1000' 0' 60' 120' 240' SCALE: HORIZONTAL SCALE 1" = 120'(APPROXIMATE) VERTICAL SCALE 1" = 40' PREPARED BY: EDDIE LY SCALE AS SHOWN DATE: AUGUST 2007 FIGURE 4 CROSS SECTION g-B' PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS, CITY OF LOS ANGELES, CALIFORNIA GEOLOGY INVESTIGATIONS UNIT LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOTECHNICAL AND MATERIALS ENGINEERING DIVISION o• N o'' 0 v 0 THIN(<3' THICf~ CLAY-RICH BED CLAY BED _= —°—°— SILT BED ~~^ GEOLOGIC CONTACT, QUERRIED WHERE UNCERTAIN QUATERNARY ALLUVIUM Qal --~ ~? ~ ? ARTIFICIAL FILL of EXPLANATION :~~ 840' CZL~~I 920' •.~ 1000' C N 26°W C~ 800' 840' ::~ 920' 960' 1000' QUATERNARY ALLUVIUM Qal 240' PREPARED BY: EDDIE LY DATE: AUGUST 2007 SCALE AS SHOWN FIGURE 5 CROSS SECTION C-C' PACOIMA SPREADING GROUNDS ARLETA AND MISSION HILLS, CITY OF LOS ANGELES, CALIFORNIA GEOLOGY INVESTIGATIONS UNIT LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOTECHNICAL AND MATERIALS ENGINEERING DIVISION 0 120' VERTICAL SCALE 1" = 40' SCALE: HORIZONTAL SCALE 1" = 120'(APPROXIMATE) THIN(<3' THICf~ CLAY-RICH BED CLAY BED O' 60' ' N 0 v 0 °—°— _= SILT BED ?— ~ GEOLOGIC CONTACT, QUERRIED WHERE UNCERTAIN ~ ~ ARTIFICIAL FILL of EXPLANATION March 5, 2007 TO: Amir Alam Geotechnical and Materials Engineering Division FROM: Ken Zimmer Water Conservation Planning Section ~ ~j- PACOIMA SPREADING GROUNDS IMPROVEME` TS REQUEST FOR SUBSURFACE INVESTIGATION REPORT PCA NO. H0321129 It is requested that your division make the necessary subsurface explorations for concept planning purposes and prepare logs and a report, which will describe the earth materials beneath Pacoima Spreading Grounds. The logs and report should also show sampling method used, location, identification designation, date of start and completion, name of the logger, and drilling subcontractor. Previously, nine drill holes were excavated as part of a geotechnical study for levee evaluation by Fugro West, Inc. Locations of drill holes are not representative of the entire spreading basin. Therefore, exploration of additional drill holes is necessary to identify the limits of a large clay layer. The plan of Pacoima Spreading Grounds with existing drill hole locations is attached for your use. ~~ This information is required no later than April 2, 2007, to enable us to meet the established project schedule. If you have any questions, please contact Marine' Gaplandzhyan at 458-6170. ~"-1MG:yg P:\wrd\GENERAL\Pacoima(Memo Attach. cc: Water Resources (Zimmer, Gaplandzhyan) LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MAl ERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds SOB NUMBER H0321129 CLIENT Water Resources Division ELEVATION DRILLER/TYPE/DIAMETER OF BORING DATES) 05/21/2007 935 Ft. BORING NO. B-1 LOGGED BY C. Masters Boart Longyear, Sonic Drilling. 8" hole LOCATION DRILLER Alex PAGE 7 OF 2 TOTAL DEPTH 40 Ft. North-central portion of Basin 6 Note. This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions classifications based on laboratory testing. Alluvium (Q81) ~ ~ w 0 ~ z Q ~ COMMENTS INTERPRETATIONS ATTITUDES DESCRIPTION ~ 0'-1': Light brown, silty sand, fine- to medium-grained, dry, loose. - ~ 1'-4': Gray-brown, silty sand, medium- to coarse-grained, with gravel to —_ 2 3" diameter, dry, loose. 3 _ 4 4'-6': Brown, silty sand, fine-grained, moist, loose to slightly dense. — 5 6 6'-12': Brown to red-brown, silty clay with fine sand, moist, slightly firm. -- — 7 — $ @ 8': 2"-4" thick sand/gravel bed. 9 10 11 12 12'-18': Green-brown to brown, silty sand with gravel, fine- to coarse-grained, o°.~ moist, loose to slightly dense. 13 @ 13.5'-14.5': Less gravelly. o~ .o ~ 14 ~ 15 .o.' o~ 16 17 o~ 18 18'-20': Orange-brown, silty sand, fine- to coarse-grained, moist, slightly dense. 19 —20 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT Water Resources Division DRILLER/TYPE/DIAMETER OF BORING DATES) SOB NUMBER H0321129 ELEVATION 935 Ft. BORING N0. B-1 LOGGED BY C. Masters Boart Longyear, Sonic Drilling, 8" hole DRILLER Alex PAGE 2 OF 2 TOTAL DEPTH 40 Ft. LOCATION North-central portion of Basin 6 05/21/2007 Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptionslclassifications based on laboretory testing. COMMENTS INTERPRETATIONS ATTITUDES LL ~ Q ~ z Q ~ DESCRIPTION Alluvium (Qal) ::a 20 20'-22': Green-brown to brown, silty sand with gravel, fine- to coarse-grained, moist, loose to slightly dense. ~. 21 .=-~ — 22 22'-26': Gray-brown, silty sand, fine- to coarse-grained, with gravel (2"-3" diameter), slightly moist, slightly dense to dense. ~: x:.-23 a— ~° — 24 ° ~~~. — 25 oo~ o — 26 O' ~' — 2~ °. — 2$ 29 @ 26'-27': Gravel to 4" diameter. 27'-28': Red-brown togreen-brown, clayey sand, fine- to coarse-grained, moist, firm. 28-33': Gray-brown, silty sand, fine- to coarse-grained, slightly moist, slightly dense. 30 -- 31 -~ 32 33 33'-34': Green-brown, clayey sand, medium- to coarse-grained with gravel. �_= 34 34'-35': Red-brown, clayey silt, moist, firm. 35 35'-37': Brown silty sand, fine-grained, moist, slightly dense. -~ 36 37 _ _ 38 -_Backfilled with Monterey sand. 37'-38': Brown, clayey sand, fine- to medium-grained, with gravel to 2" diameter. 38'-40': Brown silty sand, fine- grained, moist, slightly dense. 39 - —40 T. D.: 40 Feet. No Groundwater Encountered LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT Water Resources Division JOB NUMBER H0321129 ELEVATION 930 Ft. BORING NO. B-2 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/Sonic Drilling/8-inch diameter boring DATE 5-21-07 LOCATION North-Central portion of Basin 7 PAGE ~ OF 2 TOTAL DEPTH 40 Ft. DRILLER Alex Note: vThis log contains observations and interpretations that are valid only for the specifc date and location of the boring Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classifiralion methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ _ Q ~ ~ ~ Alluvium (Qal) _ 0 DESCRIPTION 0'-2': Brown, silty sand, fine- to coarse-grained, slightly moist, slightly dense. 1 2 °~o — 3 2'-6': Gray-brown sand, fine- to medium-grained, slightly moist, slightly dense. @ 3': Becomes gravelly (1" diameter) 4.o_ .~,o. °. p~ o•. .'. o — 5 ~o.a.. ,v g °~o °.~ ~ ' :~a°_ 7 p~ o~. .-. o _ o.o.. ,.o 8 — g 9' sharp contact. 6'-9': Dark gray sand, medium- to coarse-grained, with minor gravel, slightly moist to moist. 9'-15': Red-brown, sandy clay, moist, firm, plastic. —10 — 11 @ 11'-15': Slightly more sand, with coarse white sand grains. —12 —13 —14 15 — Groundwater @ 16' (Perched). 16 —17 15'-16': Brown, clayey sand, medium- to coarse-grained, with gravel, moist, slightly dense to dense. 16'-17': Orange brown sand, fine- to medium-grained, with gravel (2" diameter). 17'-18.5': As above @ 6'-9', except clayey .~ _18 °'' ~ . .;o gyp: a:;~.. ~. ..o 18.5'-20.5': As above @ 16'-17'. _19 ... o.' ~ 2 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds SOB NUMBER H0321129 CLIENT Water Resources Division ELEVATION 930 Ft. BORING NO. B-2 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/Sonic Drilling/8-inch diameter boring DATE 5-21-07 LOCATION North-Central portion of Basin 7 PAGE 2 OF 2 TOTAL DEPTH 40 Ft. DRILLER Alex Note: vThis log contains observations and interpretations that are valid only for the specifc date and location of the boringSubsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ _ Q ~ ~ ~ DESCRIPTION 20 @ 21'-24' slightly cemented. - .-~— 21 ~-E_ 22 ~~ 20.5'-21': Brown, silty sand, fine-grained,slightly moist, slightly dense. 21'-24': Gray-brown, silty sand, fine- to medium-grained, with gravel, slightly moist, dense. c-~-~ —°-'— 23 ~_ 24 24'-27': Orange-brown, silty sand, medium- to coarse-grained, with gravel. — 25 — 26 — 27 _— 28 _ --29 27'-28': Gray-brown sand, fine- to coarse-grained, with clay, moist, slightly dense. 28'-30.5': Light gray-brown, silty sand, fine-grained, with gravel to 1/2" diameter. --30 -- 31 @ 32'-35' sample _—_ 32 =— bag broke, material logged from broken —— 33 bag appeared similar = -- 34 to material above and below. _— 30.5'-34': Light gray, silty sand, coarse-grained, with gravel to 4"diameter, dry to slightly moist, slightly dense. 34'-40': As above @ 30.5'-34' except orange-brown color. =— — 35 _--36 --37 =— — 38 — 39 Backfilled with Monterey Sand -- 40 T. D.: 40 feet Groundwater encountered @ 16'. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT Water Resources Division DRILLER/TYPE/DIAMETER OF BORING DATES) 5-21-2007 JOB NUMBER H0321129 BORING NO. ELEVATION 935 Ft. LOGGED BY Boart Longyear/ Sonic Drilling/8" diameter boring LOCATION Central portion of Basin 1 B-3 PAGE 1 OF 2 C. Masters DRILLER TOTAL DEPTH 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptionslclassifcations based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ Q ~ ~ w 0 Alluvium (Qal) 0 = 1 2 000~ 3 DESCRIPTION 0'-1' Light brown, silty sand, fine-grained, with some clay, slightly moist, loose, roots throughout. 1'-2': Dark brown, clayey sand, fine- to medium-grained, slightly moist, slightly dense. 2'-8': Gray-brown sand, fine- to medium-grained, slightly moist, loose to slightly dense. @ 3': A 4" thick gravel lens, 0.5" diameter, rounded gravel. 4 5 6 7 @ 8': sharp contact. $ 8'-11': Orange-brown to red-brown, clayey silt/silty clay with fine-grained sand, slightly moist, firm. 9 10 0 11 12 11'-15': Brown to orange-brown, silty sand, fine-grained, with a trace of gravel and clay, slightly moist, slightly dense. Becomes coarser with depth. G o p'< ° 13 00 o.- 14 o° 15 15'-18': Light brown sand, fine- to coarse-grained, with gravel, slightly moist, slightly dense. Becomes coarser with depth. o ~ 16 000 a 17 o~ ~$ 18'-19': Brown, clayey sand, fine-grained, slightly moist. 1g 19'-22': Brown, silty sand, fine-grained, slightly clayey, slightly moist, slightly dense. Becomes more clayey with depth. 20 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT Water Resources Division DRILLER/TYPE/DIAMETER OF BORING DATES) 5-21-2007 SOB NUMBER H0321129 BORING NO. ELEVATION 935 Ft. LOGGED BY Boart Longyear/ Sonic Drilling/8"diameter boring LOCATION Central portion of Basin 1 B-3 PAGE 2 OF 2 C. Masters DRILLER TOTAL DEPTH 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classifcation methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ ~ ~ DESCRIPTION ~ Q 20 21 - - 22 23 22'-23': Red-brawn to orange-brown, silty sand, fine-grained, moist to very moist. 23'-27': As above at 19'-22'. 24 25 26 27 27'-28.5': Light green-gray sand, medium- to coarse-grained, with gravel, slightly moist, slightly dense. 28 28.5'-30': Brown silty sand, fine-grained, with clay, moist, slightly dense 29 =~ ~ @ 31'-32.5': possibly °° cemented, cuttings are ~ °:°'T fragmented. `~' ::;"~.a~o ~:d:= °~ 30 31 30'-31': Orange-brown sand, fine- to coarse-grained, with gravel, slightly moist, slightly dense. 31'-32.5': Gray-brown, silty sand, fine- to medium-grained, with gravel, slightly moist, fragmented cuttings are dense. 32 32.5'-37': Same as from 30'-31'. 33 34 35 36 37 @ 39' gradational contact. Backfilled boring with Monterey Sand @ 37': Becomes less gravelly. 38 39 39'-40': Orange-brown, slightly silty sand, fine- to medium-grained, slightly - - 40 moist, slightly dense. T. D.: 40 feet. No Graundwater Encountered. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION JOB NUMBER H0321129 ELEVATION 917 Ft. BORING N0. B-4 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/ Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION Northeast portion of Basin 10 DRILLER PAGE ~ OF TOTAL DEPTH 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classifcation methods and may vary from descriptions/classifications based on laboratory testing. ~ _ Q COMMENTS INTERPRETATIONS ATTITUDES ~ ~ ~ Alluvium (Qal) ... . _ p DESCRIPTION 0'-3.5': Light gray-brown, silty sand, fine- to coarse-grained, with gravel, dry, loose. 1 ~e° — 2 3 _ 4 3.5'-9.5': Dark brown to dark red-brown, clayey silt with fine sand, slightly moist to moist, slightly dense. — 5 — 6 ___ -_ 7 — 8 =~ — 9 ~ 9.5': sharp contact. Y a ~,'~ — 10 .;-;:a 9.5'-10': Orange-brown, silty sand, fine- to coarse-grained, with gravel, slightly moist, slightly dense. —11 a; ;a. — —12 ~— 13 - — 14 @ 14': 1.0' thick silty sand, fine-grained. _15 ~~ -~ — 16 ~: -- 17 _ ~$ °:u,-a~e~ —19 20 2 18'-24': Orange-brown to gray-brown sand, fine- to coarse-grained, with gravel, slightly moist, slightly dense. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION JOB NUMBER H0321129 ELEVATION 917 Ft. BORING NO B-4 LOGGED BY C. Masters Sonic Drilling/ 8-inch diameter boring DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/ DATES) 5-22-2007 LOCATION Northeast portion of Basin 10 DRILLER PAGE 2 OF TOTAL DEPTH 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specif c date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifcations based on laboratory testing. ~ z Q ~ COMMENTS INTERPRETATIONS ATTITUDES ~ ~ w 0 DESCRIPTION 20 'P:~~ _21 ~~ — 22 b• - 23 ~_'° ~ ° ~_ 24. 24'-36': Brown to dark orange-brown, silty sand, fine- to medium-grained, slightly moist, loose to slightly dense. --25 — 26 — 27 — 28 - — 29 — 30 — 31 — 32 — 33 — 34 '.-35 @ 36'-37.5' broken into fragments that are smaller than 1/2". _ 36 36'-37.5': Light gray, silty clay to clayey silt with sand, dry, dense. — 37 37.5'-40': As above @ 24'-36'. - 38 - 39 Backfilled with Monterey sand 2 40 T. D.: 40 Feet. No Groundwater Encountered LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICAL AND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION JOB NUMBER H0321129 ELEVATION 913 Ft. BORING NO. B-5 LOGGED BY B Thomas DRILLER/TYPE/DIAMETER OF BORING Boart Longhyear/Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION Northwest portion of Basin 11 PAGE ~ OF TOTAL DEPTH 43 Ft. Alex DRILLER Note' This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with lime. Lithologic descriptions are derived using visual classifcalion methods and may vary from descriptions/dassifcations based on laborelory testing. COMMENTS INTERPRETATIONS ATTITUDES ~' z Q ~ DESCRIPTION ~ ~ Q Allumvium (Qal) _ Q 0'-3': Dark gray to black, gravelly clay with sand, slightly moist. 1 — 2 _ 3 3'-5': Gray to dark brown, clayey silt, dry. 4 _ 5 5'-7': Medium gray to dark brown-gray, silty clay, slightly moist. — 6 _ 7 7'-9': Light tan to medium brows, sandy gravel, slightly moist, loose. 0 °— 8 ° o. ~ _ 9 9'-12': Dark brown to gray, silty clay, moist. —10 —11 @ 12'-15': more gravelly than overlying units. _ ~2 12'-15': Gray to dark brown, gravelly clay with silt, moist. — 13 —14 — 15 @ 15'-19': clay is plastic. 15'-19': Dark brown to dark. gray, clay to silty clay, very moist. — 16 —17 —18 Q—a ° ~g ° - — 20 19'-21': Tan to brown, sandy gravel with silt, dry. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds SOB NUMBER H0321129 CLIENT WATER RESOURCES DIVISION ELEVATION 913 Ft. BORING NO. B-5 LOGGED BY B. Thomas DRILLER/TYPE/DIAMETER OF BORING Boart Longhyear/Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION Northwest portion of Basin 11 PAGE 2 OF TOTAL DEPTH 43 Ft. Alex DRILLER Note. This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with lime. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z Q ~ ~ ~ Q DESCRIPTION Allumvium (Qal) 20 @ 21'-22': ash-like. _ — 21 21'-22': Gray to black silt, dry. — 22 22'-29': Medium brown to medium gray, gravelly sand with cobbles to 3" diameter, dry. o 0°° o. — 23 a ~— 24 0 0 ~ — 25 0 °~o — 26 a 0 oo.~— 27 o. — 28 o — 29 29'-34': Dark gray to dark brown, silty clay with some gravel, moist. — 30 — 31 — 32 33 .p~.. — 34 34'-37': Brown, sandy silt with gravel, slightly moist. o::4 ;~o~ —35 ~~ — 36 ~~ ~~ — 37 38 — 39 40 37'-40': Brown to gray, gravelly clay with silt, moist. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION SOB NUMBER H0321129 ELEVATION 913 Ft. BORING N0. B-5 LOGGED BY B~ Thomas DRILLER/TYPE/DIAMETER OF BORING Boart Longhyear/Sonic Drilling/ S-inch diameter boring DATES) 5-22-2007 LOCATION Northwest portion of Basin 11 PAGE 3 OF TOTAL DEPTH 43 Ft. Alex DRILLER Note: This log contains observations and interpretations that are valid only for the specif c date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z Q ~ ~ ~ w 0 DESCRIPTION Allumvium (Qal) — 40 40'-43': Brown silty clay with some gravel, moist. —41 42 Backfilled with Monterey sand. — 43 — 44 — 45 — 46 — 47 — 48 — 49 — 50 — 51 — 52 — 53 54 — 55 — 56 — 57 — 58 — 59 — 60 3 T. D.: 43 feet. No Groundwater Encountered. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION SOB NUMBER H0321129 ELEVATION 931 Ft BORING NO. B-6 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/ Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION South - Central portion of Basin 2 PAGE 1 OF TOTAL DEPTH 51 Ft. DRILLER Alex Note: This log cordains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. ~ithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. ~ z ~ COMMENTS INTERPRETATIONS ATTITUDES ~ ~ _ ~ w 0 Q Alluvium (Qal) 1 DESCRIPTION 0'-1': Light brown, silty sand, fine- to medium-grained, dry, slightly dense, roots throughout. 1'-8': Brown, silty sand, fine- to medium-grained, with clay, slightly moist slightly dense. 2 3 4 5 - 6 7 $ 8'-9': Dark brown, silty sand, fine-grained, slightly moist, slightly dense. 9 9'-14': Dark brown, silty sand, fine-grained, with clay and some gravel, slightly moist, slightly dense. 10 11 12 13 o ~4 o , o. o: 0 ~o o ~ a ° o. . o° . ao °~ 15 16 O 17 18 19 20 3 14'-23': Orange-brown sand, fine- to coarse grained, with gravel (to 2" diameter), slightly moist, slightly dense. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION JOB NUMBER H0321129 ELEVATION 931 Ft BORING N0. B-6 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION South - Central portion of Basin 2 PAGE 2 OF TOTAL DEPTH 51 Ft. DRILLER Alex Note' This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES v z Q ~ DESCRIPTION ~ ~ w 0 00 2O a 0 21 o o. . 22 @ 23'-26': water on fracture surfaces. °0 23 23'-26': Brown, clayey silt-silty clay with fine-grained sand, moist to wet, dense. 24 25 00 o 26 26'-28': As above @ 14'-23'. 27 @28'-34': Moderately 'opo cemented. '•,g ~ 28 2g~_34': Light gray-brown, silty sand, fine- to coarse-grained, with gravel to 2" diameter, slightly moist, dense. ..°:: 29 a': ~. ., _~ °. 30 f:°' 31 ~`o' 32 ~.~:, ...o.~. 33 34 34'-36': As above @ 23'-26'. 35 • .:off; °:~,;.• :o~. ~'..0 40': 6" diameter cobble 36 36'-47': Orange-brown, silty sand, fine- to coarse-grained, with gravel to 3"diameter, slightly moist, slightly dense. 37 38 39 .:~:: a.. :o °' '~ 40 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION SOB NUMBER H0321129 ELEVATION 931 Ft BORING NO. B-6 LOGGED BY C. Masters DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/ Sonic Drilling/ 8-inch diameter boring DATES) 5-22-2007 LOCATION South - Central portion of Basin 2 PAGE 3 OF TOTAL DEPTH 51 Ft. DRILLER Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location ~f the boring. Subsurface conditions vary hetween borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ Q ~ ~ ~ w 0 DESCRIPTION 40 ~:o, ;: d.... ~ 41 `-.~.~. ::ca:~: 42 ~~, 43 .:.a: ~ 44 a. ,~~ ~: 45 .n~.,.; 47 47'-50': Brown, clayey silt, moist, slightly dense to dense. 48 __. Backfilled with Monterey sand. - --- 49 50 50'-51': Brown clayey silt with fine-grained sand, moist, slightly dense to dense. 51 52 53 54 55 56 57 58 59 60 3 T. D.: 51 feet. Seepage encountered from 23' to 26'. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION SOB NUMBER H0321129 ELEVATION 930 Ft. BORING NO. B-7 LOGGED BY B• Thomas/L. Bell DRILLER/TYPE/DIAMETER OF BORING Boart Longyear/Sonic Drilling/ 8-inch diameter boring DATES) 5-22 to 23-2007 LOCATION Southern portion of Basin 7 PAGE ~ OF TOTAL DEPTH DRILLER 2 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z ~ ~ Q Alluvium (Qal) DESCRIPTION ~ _ Q p~ o~'o 1 ~~ o~' 2 °~ 3 - 4 0'-3': Dark brown to dark gray, gravelly sand, moist. o' 3'-9': Moderate brown to gray, sandy silty, dry. 5 6 - -_ -- 7 $ g 9'-17': Dark brown, sandy clay with silt, very moist. 10 11 12 @ 12'-15': more clayey. 13 14 15 @ 15'-19': more silty. 16 Perched water@ 17'. ~~ p' ~~ 18 19 ° ~~~ 20 17'-21': Dark brown, clayey fine- to coarse-grained sand with gravel and cobbles, moist, loose. Gravel and cobbles to 2" diameter, sub-angular to sub-rounded, granitic. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION SOB NUMBER H0321129 ELEVATION 930 Ft. BORING NO. B-7 LOGGED BY B Thomas/L. Bell DRILLER/TYPE/DIAMETER OF BORING Boart Lonpyear/Sonic Drilling/ 8-inch diameter boring DATES) 5-22 to 23-2007 LOCATION Southern portion of Basin 7 PAGE 2 OF TOTAL DEPTH DRILLER 40 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc dale and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classifcalion methods and may vary from descriptions classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES Alluvium (Qal) ~ ~ W 0 ~ z Q ~ ~ DESCRIPTION 20 21 21-24': Gray, coarse-grained sand with traces of clay and silt, wet, dense. 22 ~~ 23 ~~o ~ o . ~. 24 24'-27': Light brown, coarse-grained sand with gravel, slightly moist, slightly dense. Gravel to 1"diameter. ~ 25 0 o. 26 00 ° o' 27 o. 28 29 000 0 ~. 30 .~:e :~ 31 :::~ 32 27'-33': Gray-brown, coarse-grained sand with gravel, wet, cobbles to 5" diameter, subangular. @ 30'-33': Less gravel and traces of clay. 33 33'-39': Gray, sandy gravel with sift, moist, gravel to 3/4" diameter and ° subrounded to rounded. Scattered cobbles to 8" diameter. a. 34 0 0 35 0 00 36 Backfilled with Monterey sand. 37 o. ° 38 .o:_ 3g 39'-40': Dark brown, sandy silt with clay, moist. 40 Total Depth: 40 Feet. Groundwater encountered at 17'. 2 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT WATER RESOURCES DIVISION DRILLER/TYPE/DIAMETER OF BORING DATES) 5-23-2007 SOB NUMBER H0321129 ELEVATION 926 Ft. BORING NO. B-8 LOGGED BY Boart Longyear/Sonic Drilling/ 8-inch diameter boring LOCATION Levee between Basin 3 and Basin 4 PAGE ~ OF L. Bell TOTAL DEPTH DRILLER 53 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboretory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ _ Q " z ~ ~ Artificial Fill (af): 0'-9' _ p °° o — 1 D p°v ~ DESCRIPTION 0'-1/4': Asphalt. 1/4' - 7': Dark Brown, silty sand, slightly moist to moist, dense; coarser with depth. 2 0o e — 3 ado _ 4 — 5 D pro — 6 °v0 7 °moo 7'-9': Medium brown, gravelly fine-grained sand, slightly moist, Gravel is well rounded. 8 p pvp 9 Alluvium (Qal): 9'-53'. .. ~ @ 9': sharp contact. ~ ~ ~ _ 10 9'-12': Gray, coarse-grained sand, slightly moist. —11 _ ~2 00 — 13 o' 12'-12.5': Dark brown, sandy clay with cobbles, slightly moist. 12.5'-15': Light gray, gravelly coarse-grained sand, dry. Fine-grained gravels are subangular to rounded. o. —14 °_ 15 p•' 15'-18': Light gray, cobbly, medium- to coarse-grained sand, slightly moist; cobbles to 4"diameter. .o'•'~— b 16 o. °-17 P °'°— 18 18'-20': Light gray, cobble layer, little to no fines. 00 — 19 0 20 @ 20': Slightly silty and clayey. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT WATER RESOURCES DIVISION DRILLER/TYPE/DIAMETER OF BORING DATES) 5-23-2007 SOB NUMBER H0321129 ELEVATION 926 Ft. BORING N0. B-8 LOGGED BY Boart Longyear/Sonic Drilling/ 8-inch diameter boring LOCATION Levee between Basin 3 and Basin 4 PAGE 2 OF 3 L. Bell TOTAL DEPTH DRILLER 53 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES = Q ~ ~ ~ W 0 DESCRIPTION 20 — 21 21'-23': Light gray, silty sand with gravel and some small cobbles. .~~ .~"' ..o. ~. .-22 ~o' ~ — 23 0 23'-27': Light brown, coarse-grained sand with gravel and cobbles, moist. a — 24 0 0 o — 25 0 — 26 0~o ~ — 27 o. 27-35': Light brown to gray, sand with cobbles/boulders, dry. ° o. ° — 28 o° — 29 ~O 0 o — 30 00.0_31 0 — 32 0 o°~ — 33 0 o — 34 a o ~ — 35 35'-37': Clayey gravel with cobbles, moist. 36 37'-47': Difficult _ 37 sample recovery. Some ~~;b ~. sample is lost. o~ :~~. :. ~~~ . _ 38 ..o.: — 39 ~~.:. ~ao ° ~ ~ 40 37'-47': Light brown to gray, coarse sand, with gravel, cobbles and possible boulders, moist, no fines. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT WATER RESOURCES DIVISION DRILLER/TYPE/DIAMETER OF BORING DATES) 5-23-2007 SOB NUMBER H0321129 ELEVATION 926 Ft. BORING NO. B-8 LOGGED BY 3 OF TOTAL DEPTH DRILLER 53 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions~classifcations based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ ~ w 0 ~ z Q ~ DESCRIPTION - 40 o .o 0 o a-41 o .'a ~a - 42 0 o - 43 0 @ 44.5'-46.5': Oxidized o° — 44 44.5'-46.5': Cobbly sand with clay coatings, wet. zone. 6 00 ~ -45 O ° - 46 00 o ~ — 47 0o 47'-50': Medium-grained sand with gravels and cobbles. Decreasing gravels and cobbles with depth. 000 - 48 0 ° -49 00 0 0._ 50 ~o °.c> — 51 o°: o — 52 0 Backfilled with Monterey sand. 50'-52': Orange-brown to dark brown, medium-grained sand with a trace of gravel to 1.5"diameter. 52'-53': Light brown, medium-grained sand with coarser gravel. °°— 53 — 54 — 55 56 - 57 58 59 -60 3 L. Bell Boart Longyear/Sonic Drilling/ 8-inch diameter boring LOCATION Levee between Basin 3 and Basin 4 PAGE T. D: 53 Feet. Seepage encountered at 44.5'. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION TYPE/DIAMETER OF BORING DATES) JOB NUMBER H0321129 ELEVATION 918 Ft. BORING NO B-9 LOGGED BY Linda Bell PAGE 1 Boart Longyear/Sonic Drilling/8-inch diameter boring TOTAL DEPTH LOCATION Levee between Basin 5 and Basin 12 DRILLER 5-23-2007 OF 57 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/dassifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z Q ~ ~ ~ w 0 Q Artificial Fill (af): 0'-8' °0 1 D p°o 2 ° v OP J DESCRIPTION 0'-1/4': Asphalt. 1/4'-5': Dark Brown to gray, silty sand to sandy silt with clay. 4 °av 5 5'-7': Dark brown, sandy silt with clay, slightly moist. p Dop 6 °v 4P Alluvium (Qal:) 8'-57'. ~ 7'-8': Dark brown, clayey sand with cobbles, slighty moist. ~~° • p. $ 8'-10': Gray, sand with gravel and cobbles. o' ~ o~ . o0 g .• ~~ 10'-11': Dark brown, sandy silt with a trace of clay. ~~"o~'o ~~ 11 11'-20': Light gray, coarse-grained sand with coarse gravel. o~ o.. ~~ ~ 12 ~3 o~ — 14 o~'o ~. ~ o: ~ 15 o~ O ~ ', • °z~ ~6 ..0 ~7 ~o . °~~ ~. ~ o.°~ o~. .~~ 18 19 20 13'-13.5': Dark red-brown, silty clay layer. 16.5'-17': As above @ 13'-13.5'. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT WATER RESOURCES DIVISION TYPE/DIAMETER OF BORING DATES) SOB NUMBER H0321129 ELEVATION 918 Ft. BORING N0. B-9 LOGGED BY Linda Bell PAGE 2 Boart Longyear/Sonic Drilling/8-inch diameter boring TOTAL DEPTH LOCATION Levee between Basin 5 and Basin 12 DRILLER 5-23-2007 OF 57 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary irom descriptions/classifcations based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z ~ ~ ~ _ ~ w 0 DESCRIPTION 20 20'-21': Dark red-brown, silty clay; more clay-rich with depth. 21 21'-24': Dark red-brown, clay with minor amount of gravel and silt. 22 23 0 ~--~ 24 ._o.. 25 °~o 26 ~•;~ p O~~ •. 27 24'-27': Dark brown, silty gravel with clay, coarser with depth. Granitic gravel is highly weathered. 27'-29': Gravelly sand, no fines. ~p , 2$ . ~0 0 .' o . 2g ~'.o ~. 30 :op 31 ~° 32 o.• 29'-37': Gravelly sand, slightly clayey. ~o 0 33 ~°-34 o .•' ~~° 35 ~o'0 36 ~ 37 ° o. 38 ;O p o° . 39 ~o 40 37'-44': Light brown to gray, sandy gravel with cobbles up to 6" in diameter. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION TYPE/DIAMETER OF BORING DATES) JOB NUMBER H0321129 ELEVATION 918 Ft. BORING NO. B-9 LOGGED BY Linda Bell PAGE 3 Boart Longyear/Sonic Drilling/8-inch diameter boring TOTAL DEPTH LOCATION Levee between Basin 5 and Basin 12 DRILLER 5-23-2007 OF 57 Ft. Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifcations based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ Q ~ ~ ~ w 0 DESCRIPTION o. 40 0 0 ° 41 0°0 ~ 0 0 0°~ 0 ° ~ 42 43 44 44'-45': Clayey sand with silt. 45 45'-46.5': Dark brown, silty clay, slightly moist to moist, micaceous. 46 ~~ 47 46.5'-57': Red-brown, silty sand with gravel, fine-grained, moist; coarser with depth. 48 .0 49 0 S0 ;0 51 52 53 .o 54 ;o 55 56 Backfilled with Monterey sand. 57 58 59 60 T. D.: 57 Feet. No Groundwater Encountered. 3 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT Pacoima Spreading Grounds CLIENT WATER RESOURCES DIVISION DRILLERlTYPE/DIAMETER OF BORING DATES) 5-23-2007 SOB NUMBER H0321129 ELEVATION 918 Ft BORING N0. B'~ ~ PAGE LOGGED BY L. Bell Boart Longyear/Sonic Drilling/ 8-inch diameter boring LOCATION Levee between Basin 11 and Basin 12 1 OF TOTAL DEPTH 27 Ft. DRILLER Alex Note: This log contains observations and interpretations that are valid only for the specific date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classification methods and may vary from descriptions/classifications based on laboretory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ z Q ~ ~ W 0 Q Artificial fill (afl: 0'-9' a~o ~ D ~vD 2 DESCRIPTION 0'-1/4': Asphalt. 1/4'-8': Brown, silty sand. °v OP ~~~ 4 p ~vp — 5 oov 6 °ao 7 p ~vp Alluvium (Qal) 9'-27' $ 8'-9': Dark brown, organic-rich clay, moist. g 9'-15': Brown, fine- to medium-grained sand with trace of gravel. 10 11 12 13 14 15 15'-17': Dark brown, clay with silt. 16 ~7 17'-18.5': As above @ 9'-15'. 18 ~9 18.5'-21': Red brown, clay, firm. 20 2 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS GEOLOGY SECTION - GEOTECHNICALAND MATERIALS ENGINEERING DIVISION SUMMARY LOG OF BORING PROJECT CLIENT Pacoima Spreading Grounds WATER RESOURCES DIVISION DRILLER/TYPE/DIAMETER OF BORING DATES) 5-23-2007 SOB NUMBER H0321129 ELEVATION 918 Ft BORING N0. B-~ ~ PAGE LOGGED BY L. Bell OF DRILLER Alex Note: This log contains observations and interpretations that are valid only for the specifc date and location of the boring. Subsurface conditions vary between borings and with time. Lithologic descriptions are derived using visual classifcation methods and may vary from descriptions/classifications based on laboratory testing. COMMENTS INTERPRETATIONS ATTITUDES ~ ~ ~ ~ Q DESCRIPTION 20 21 21.5', sharp contact. Backfilled with Monterey sand. ° 0 O 0°0 0 00 0 0 0 0 a. 0 o. ~ 21'-21.5': Clayey gravel with sand 21.5'-27': Gravelly sand with cobbles. 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 2 TOTAL DEPTH 27 Ft. Boart Longyear/Sonic Drilling/ 8-inch diameter boring LOCATION Levee between Basin 11 and Basin 12 2 T. D.: 27 Feet No Groundwater Encountered. This page intentionally left blank. COUNTY OF LOS ANGELES COUNTY FW Y. ST. E ST. E R A E P . ST.E BERNARDI NO ST. E 170TH PI NE S D . CR EE K HY. H Y . N 985 O Y T ES CR PACOIMA S 9 5 5 RN BE FW Y. 5 95 DI 5 945 9 3 5 DI VERSI ON A 8 93 35 9 " 11 0. 0’ 11 80 ’ 3. 91 " 5 94 5 93 MA PACOI G LO N N SA E 9 35 CKS O R E G N A R 9 40 9 35 S CK O R . LAKEW O OD 8 93 0 C O 94 0 0 5 9 3 5 BAY 9 4 4 9 TE RM I NA I SL L AN D F W Y C N O C H AR BO R KS C O R S K BASIN 94 HILLS O DR PE ROC 9 3 6 Y . . H SP A S K C O R GARDENS H Y . 94 Thomas Bros. Pgs.502- A3, A5, A6 501- J3, J4, J5 0 0" ’ 40 4 4 9 934 933 932 931 0 93 9 45 930 94 0 9 3 5 3 4 9 930 BASIN 3 925 92 9 LOCATION MAP 5 93 " 5 3 . 0 1 ’ 3 9 EAST SETTLING 21" 2. 49’ 920 72 ’ 8. 22 " BASIN BASIN 4 91" 11. 48’ 94 3 21 LOW FLOW INTERBASIN STRUCTURE "I" DETAILS 22 OUTFALL STRUCTURE DETAILS 23 CONTROL HOUSE - BUILDING REINFORCEMENT 24 CONTROL HOUSE - BUILDING ELEVATIONS 25 CONTROL HOUSE - DOOR LOUVER AND FAN DETAILS 26 CONTROL HOUSE - ELECTRICAL LIGHTING INSTALLATION 27 CONTROL HOUSE - PLAN AND SECTIONS 28 MECHANICAL -TYPICAL EQUIPMENT LAYOUT FOR INTERBASIN STRUCTURES 29 MECHANICAL -TYPICAL FLOW METER STATION AND INSTRUMENTATION DETAILS 940 5 3 9 939 938 937 936 935 934 932 933 931 929 930 928 927 9 3 0 93 4 3 93 9 1 9 943 P A R 5 92 92 0 0 92 92 5 0 93 93 5 5 3 9 ER 919 0 93 915 5 930 W O T 921 P I R 926 ONC C 926 93 0 C ON C 93 e n i L 0 93 5 92 9 3 4 3 3 9 92 4 1 3 9 ER 92 0 2 3 9 0 93 5 2 9 92 0 92 5 0 3 9 W TO 92 5 9 2 9 on i ss i 92 6 92 5 W TO 920 925 9 3 6 93 6 0 93 0 92 92 0 91 5 925 8 2 9 R E ne Li C ty i BASIN 2 2 92 1 92 0 92 9 91 D W 920 P PACOIMA SPREADING GROUNDS - DWG NO 21-D101 7 2 9 W " 2 7 6 2 9 0 91 5 2 9 4 2 9 8 91 O M 91 5 9 05 91 0 915 915 9 1 8 R E N A BASIN 6 3 91 W TO D 4 91 M L I F OW T ER PWFB 1916 PG 207-214 9 1 7 2 91 9 1 6 0 91 T 91 0 7 1 9 1 91 90 5 910 91 0 E R 0 91 T 5 1 9 900 10 9 3 91 4 1 9 2 1 9 Pacoima Wash Unit 6, Lateral "E", 60" RCP O 6 1 9 0 91 T S 8 1 9 05 9 9 1 5 905 905 E V A 90 5 5 91 0 2 9 O e n i L r te a 3 2 9 2 2 9 1 2 9 W FCC0001207PACOI M ASGE. DGN OUTLET STRUCTURE DETAILS 6 3 9 92 5 92 7 A L 9 15 91 5 1 91 0 91 905 10 9 5 0 9 5 90 0 91 Ex or Exist EXISTING Inv INVERT JS JUNCTION STRUCTURE OS OUTLET STRUCTURE RCB REINFORCED CONCRETE BOX RCP REINFORCED CONCRETE PIPE STL STEEL PIPE TS TRANSITION STRUCTURE TW TOP OF WALL WS WEIR STRUCTURE WSE WATER SURFACE ELEVATION Interbasin Structure to Exst Lateral "E" H SP A J.LI 0 0 9 0 90 CADD PROJECT FI LE NAM E 20 5 92 n o i ss i sm an Tr 92 8 92 0 9 10 CHECKER WEIR STRUCTURE DETAILS 0 93 sm n ra T 92 9 92 5 BASIN 1 935 0 92 PACOIMA SPREADING GROUNDS 9 2 0 9 2 5 90 5 END STRUCTURE WEIR STRUCTURE DETAILS 19 7 93 92 3 ES 18 8 93 930 93 0 91 5 5 91 ELEVATION WEIR STRUCTURE 5 93 93 0 93 1 P BASIN 5 THE GAS COMPANY (GAS) ? El or Elev 17 2 4 9 1 94 0 94 9 93 5 93 5 93 DW OWENS VALLEY (WATER) PACOIMA WASH CHANNEL FILE NO. 144, PAGES 21, 26, 46-49, 60 930 940 0 94 8 93 92 5 REFERENCES 935 92 7 925 5 92 93 8 925 920 0 92 CONSTRUCTION JOINT INTAKE STRUCTURE 9 4 3 943 942 940 935 930 1 2 9 0 2 9 DEPARTMENT OF WATER AND POWER (POWER) Const Jt 16 940 940 941 94 0 93 2 SOUTHERN CALIFORNIA EDISON (POWER) 9 4 3 930 942 ST RE DEVONSHI 935 DEPARTMENT OF WATER AND POWER (WATER) BOTTOM RUBBER DAM AND CHANNEL WALL DETAILS 9 3 9 930 915 Bot 15 935 940 y t Ci 942 0 3 9 935 930 93 0 920 ABBREVIATIONS RUBBER DAM AND CHANNEL WALL DETAILS 925 0 2 9 UTILITIES RFS/FB 194-162 14 935 940 5 93 930 920 93 5 PIPE LOCATION REPORT NO. 86477 RUBBER DAM AND INTAKE PLAN VIEW 9 35 LA 8 92 TOPOGRAPHIC MAP NO. 21-T101 (OCT. 2007) 13 95 5 KS HAWAIIAN F W BEACH N SA E V A 940 SLOUGH N 5 93 WEST SETTLING 5 3 9 LONG BIXBY ROLLING CERRITOS E SC HILLS ESTATES HILL 95 5 5 3 9 ROLLING LAKEWOOD SIGNAL PROPOSE ACCESS RAMP PLAN AND PROFILE DI 945 940 95 5 950 9 4 947 946 945 944 943 942 941 950 R N A B SA 0 94 940 . B L V D E G A N R O D N O M IA 935 93 5 GABRI EL 99 5 9 50 9 45 95 7 DI NO AR . Y FW DO BL RA VD . GL EN H C A BLV I EN DA D. E IV 95 9 B A G SAN BLVD. D R EA M SE RO . BL VD D FW Y. H AC DI TY CO UN RD . L TA S Y R C . L IE R FW Y. LE A D N LE G FW Y. DI LAKE E L G CA NY ON RD . E V A N L E A S O R N D . LI TU T T JU LE N G A M T.G S AN G ELE H Y. C R E ST FW Y. EG DI A RD. NG PA TO RD. D KANAN CANYON M ALI BU M U O BLVD. SAN R BLVD. CAN YO N RD . LA S VI RG E N ES RD. . D R . Y H E L O DEC LH U M A BE 940 93 9 SEPULVEDA 5 93 ROC E AR I R NA E Y 0 95 7 94 5 93 COAST 12 . F W Y . FWY. BLVD. 945 0 94 7 3 9 O PROJECT SITE O LOMITA PALOS VERDES ESTATES G P A C I FI C CARSON IE TORRANCE D C BEACH EXCAVATION AND GRADING PLAN - DIVERSION CHANNEL INTAKE 940 . H P S A SA N REDONDO 11 SPH A LA MIRADA 5 95 H. COUNTY E L I P T R I D 95 2 95 1 5 94 SPRINGS NORWALK 0 95 95 4 95 3 ASP M ST FOX FWY. . H P S A HERMOSA BEACH EXCAVATION AND GRADING PLAN - BASIN 3 , EAST & WEST SETTLING BASINS DI . H P S A - R O U RID R O C INDUSTRY E P I P BELLFLOWER ARTESIA 10 R O COMPTON GARDENA ARTESIA EXCAVATION AND GRADING PLAN - BASIN 4 AND 5 RID OR C PARAMOUNT 9 95 6 95 5 SANTA FE B LV D . EXCAVATION AND GRADING PLAN - BASIN 1 & 2 DI A T E L DOWNEY 8 5 LAWNDALE PICO RIVERA EXCAVATION AND GRADING PLAN - BASIN 6 4 9 LYNWOOD WHITTIER GARDENS SOUTH GATE HAWTHORNE WALNUT LA PUENTE 8 95 R A . BA Y I BELL 7 E P PI D A V L C I B N F CUDAHY F I RE S T ONE DISCHARGE CONDUIT 60 IN. RCP AND DOWN DRAIN DETAIL 95 7 POMONA . Y O SEGUNDO MANHATTAN BEACH I INGLEWOOD LAKE MONTEBELLO BELL HUNTINGTON PARK MANCHESTER BLVD. L D COMMERCE MAYWOOD BLVD. F WY . WEST COVINA A E . F R N F B Y O C T . C RD M A EL SA NT AA NA VERNON PUDDINGSTONE RES. COVINA A CULVER CITY FOOTHILL N L I N C O L N MONTE LEGG POMONA 6 O S A N TA C PARK ROSEMEAD Y . DIMAS W F F W 6 5 9 SAN R CA MONI A NT SA RES. CLAREMONT FWY. IRWINDALE BALDWIN PARK SO. EL COMP. RES. O SANTA MONICA P MONTEREY PROFILE - INTERBASIN CONDUITS 72" RCP CREEK LIVE OAK BERNARDINO LOS ANGELES HY . THOMPSON GLENDORA ALOSTA AVE. AZUSA 5 R O D I R R O C N SA TEMPLE CITY EL MONTE RES. C C I F CI A P Y. BEVERLY HILLS SAN DIMAS RES. DR. BLVD. FOOTHILL ARCADIA SITE PLAN - IMPROVEMENT FACILITIES PE I P FW . Y LOWER RES. BIG DALTON OR D STONE CANYON A N E SAN MARINO D A S SO. PASADENA A P . SAN GABRIEL Y W F ALHAMBRA 4 5 6 9 CANYON RES. HUNTINGTON SITE PLAN - EXISTING FACILITIES 0 RES. FRANKLIN 8 5 9 97 UPPER W F COAST HOLLYWOOD 3 5 DUARTE COLORADO DR. MUL HOL L A ND GENERAL NOTES, INDEX TO STANDARD PLANS, CONCRETE REMOVAL NOTES 97 MONROVIA RES. MUL HOL L AND RES. FWY. ENCINO . Y H SAWPIT CANYON BRADBURY PASADENA RRI CO RES. SIERRA MADRE Replace ex. radial gate with 8’ H rubber dam BUB BLER D HILLS B LV D . 0 8 9 GLENDALE Four 54" RCP pipe in parrallel 5 8 9 T E RESERVOIR 0 99 VENTURA SAN GABRIEL 5 99 A T S F. C. BASIN OO R E K MT. WILSON SANTA ANITA YW LL LAND RESERVOIR HO AN N KA L N IL E L O A R U T N E V Y. BURBANK SEPULVEDA HIDDEN COUNTY DAM COGSWELL PE I P H RES. FW OR D T D HANSEN ES L GE AN RRI O C O G CHATSWORTH E 5 99 O FWY. VALLEY T U JU N G C A A N R D YO . N 2 990 F SIMI LAKE E P PI TY SAN FERNANDO RES. CRYSTAL RESERVOIR R O D I R R O C UN SAN FERNANDO BIG TUJUNGA B I G E P I P CO RES. H OOT F I L L TITLE SHEET K R T 1 C N A NS AI T UN MO E DESCRIPTION O S I E R H Y . B I G R GA B RI E L C RD . O D N N SA N A R FE . D R O L E T N A E P A N T E L O P E RD . RESERVOIR S A N ND SA R PACOIMA SPREADING GROUNDS ENHANCEMENT PROJECT HY. T E JO N HY T E U BOUNDARY PEARBLOSSOM LITTLE ROCK S Q U F O R T FWY. EY L L VA A O B ST. E S SOM LO B HY. BLVD. BI G SAN FR A RESERVOIR DISTRICT UNA PALMDALE INDEX TO PROJECT PLANS SH NO SAN CONTROL RESERVOIR DRY CANYON 47TH UI TO I SQ NC LAKE ST.E C . FLOOD COUNTY ANGELES CA NY ON Y . R D PALMDALE BOUQUET CANYON RES. AVE. P 165TH AN . YO D N Y R . W F O Y A M P AVENUE . D R O AVENUE 90TH N N Y U C E LAKE T RD . R A K PALMDALE M F O T RES. LOS AVENUE 30TH S L AK E S P 50TH LAKES . D R CASTAIC Y R N E H 60TH MUNZ . D R ANTELOPE RESERVOIR 10 TH N LAKE HUGHES DEPARTMENT OF PUBLIC WORKS J ST E AVENUE ELIZABETH Y . E LD RES. S E H G U H G 140TH I COUNTY H Y. ST. W AVENUE FAIRMONT EL I Z AB ET H LAKE PYRAMID E ST. E 170TH R I R D . R H GO CA NY ON AVENUE ER R A SI LAKE D AVENUE TWEEDY F A E R S M . O D N . T A RD . P I N E COUNTY VALLEY UR NT LANCASTER LAKE ST.W 260TH AVENUE QUAIL 110TH VE . RD ST.W L AN CA ST ER ST.W KERN LOS ANGELES VICINITY MAP SCALE:1"=400’ Los Angeles County Department of Public Works The Information Shown Hereon is PRELIMINARY Unofficial and Subject to Change C.CHEN COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS APPROVED GAIL FARBER DIRECTOR OF PUBLIC WORKS USA TOLL FREE * EXP. T S C63209 DATE CIVIL A T E 1-800-227-2600 ENHANCEMENT PROJECT * 06/30/12 OF V.TE DRAFTER NO. BY ASSISTANT DEPUTY DIRECTOR PACOIMA SPREADING GROUNDS I A CALL CHARLES C. CHEN ER RECOMMENDED D E IN DATE G DEPUTY DIRECTOR N BY TWO DAYS BEFORE YOU DIG N R EGIS TE R E S S I E O NA OF L PR E DESI GNER 60% PLANS R FO I L CA SUBMITTED DATE MK TITLE SHEET DESCRIPTION BY DATE REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.1 SHEET 1 OF 29 TS-DF 11/08 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 2:38:53 PM GENERAL NOTES 1. ELEVATIONS SHOWN ARE IN FEET BASED ON LOS ANGELES CITY, WORK PROCEDURES UNDER TRANSMISSION LINES INDEX TO STANDARD PLANS *LADWP SHALL PROVIDE SET PROCEDURES DURING REVIEW PROCESS LACDPW 2000 ADJUSTMENT, NAVD 1988 DATUM. 2. STD. PLAN ALL PIPE IN OPEN TRENCH SHALL BE BEDDED ACCORDING TO LACDPW TITLE 3080-3 PIPE BEDDING IN TRENCHES STANDARD PLAN 3080, CASE III, EXCEPT BELL AND SPIGOT PIPE 3090-1 CRITERIA FOR THE DESIGN OF SHORING FOR EXCAVATIONS WHICH SHALL BE CASE II BEDDING, UNLESS OTHERWISE SHOWN. "W" 3091-1 SAMPLE SHEET FOR USE AS A GUIDE IN PREPARING CALCULATIONS VALUES SHALL BE AS SPECIFIED ON STANDARD PLAN 3080 FOR CASE FOR SHORING OF EXCAVATIONS III BEDDING, NOTES (a), (b), AND (c). IF THE "W" VALUE AT THE 3093-1 UNIFIED SOIL CLASSIFICATION SYSTEM TOP OF THE PIPE IS EXCEEDED, THE BEDDING SHALL BE MODIFIED, 6002-1 PORTABLE SECURITY FENCE FOR OPEN TRENCHES AND/OR PIPE OF ADDITIONAL STRENGTH SHALL BE PROVIDED. THE 6008-1 MINIMUM PUBLIC SAFETY REQUIREMENT FOR OPEN EXCAVATIONS PROPOSED MODIFICATION SHALL BE APPROVED BY THE DEPARTMENT. 3. ALL EXISTING UTILITIES SHOWN ON THE PLANS ARE THE PROPERTY OF (APPLICABLE AGENCY), UNLESS OTHERWISE NOTED. 4. EXISTING UTILITIES SHALL BE MAINTAINED IN PLACE BY THE SPPWC CONTRACTOR, UNLESS OTHERWISE NOTED, AND ALL UTILITIES CROSSING STD. PLAN THE TRENCH SHALL BE TEMPORARILY SUPPORTED TO THE SATISFACTION OF THE OWNER. 5. THE CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS TO DETERMINE THE DEPTH AND LOCATION OF EXISTING UTILITIES WHERE SO INDICATED BY THE SYMBOL " ". 6. WHERE THE UTILITIES ARE INDICATED ON THE PLANS TO BE SUPPORTED, SAID SUPPORTS SHALL BE IN ACCORDANCE WITH SPPWC STANDARD PLAN 224-1, UNLESS OTHERWISE INDICATED. 7. ALL RESURFACING, CURBS, GUTTERS, SIDEWALKS, DRIVEWAYS AND OTHER EXISTING IMPROVEMENTS TO BE RECONSTRUCTED SHALL BE CONSTRUCTED TITLE 323-1 MANHOLE - CONCRETE BOX STORM DRAIN 327-2 MANHOLE FOR EXISTING RCB 333-3 JUNCTION STRUCTURE - PIPE TO RCB 351-2 CSP FLARED INLET 600-3 CHAIN LINK FENCE AND GATES 606-3 METAL HAND RAILINGS, TYPE C 610-3 REINFORCED CONCRETE RETAINING WALL TYPE 1 617-3 REINFORCED CONCRETE RETAINING WALL DETAILS 635-3 STEEL STEP 640-3 REINFORCED CONCRETE STAIRWAY AT THE SAME ELEVATION AND LOCATION AS THE EXISTING IMPROVEMENTS, UNLESS OTHERWISE NOTED. 8. EXISTING TREES SHALL BE REMOVED ONLY IF SO DESIGNATED. THOSE TREES NOT INTERFERING WITH CONSTRUCTION SHALL BE PROTECTED IN PLACE. 9. RIGHT OF WAY FENCING SHALL BE PLACED 6" INSIDE THE RIGHT OF WAY LINE. CONCRETE REMOVAL NOTES 10. ALL FIELD BOOK REFERENCES ARE TO LOS ANGELES COUNTY DEPARTMENT 1. OF PUBLIC WORKS FIELD BOOKS, UNLESS OTHERWISE NOTED. NEW JOINT, MAKE A 3/4 INCH DEEP SAW CUT ON ALL 11. THE WORK SHOWN ON THESE DRAWINGS REQUIRES THE PRIME CONTRACTOR DATE WHERE REINFORCEMENT SHALL BE RETAINED THROUGH THE TO HAVE A VALID CLASS A LICENSE ISSUED BY THE STATE OF EXPOSED CONCRETE SURFACES ALONG THE REMOVAL LIMITS. CALIFORNIA. DO NOT CUT OR DAMAGE EXISTING REINFORCEMENT. 12. BENCHING OF THE LEVEES SHALL BE AS SPECIFIED IN 2. USING HAND-HELD EQUIPMENT, CAREFULLY REMOVE THE SECTION 300-4.4 OF THE GREENBOOK. CONCRETE FOR THE FULL DEPTH OF THE WALL OR SLAB AND FOR A MINIMUM DISTANCE FROM THE SAW CUT EQUAL TO THE LONGEST EXTENSION OF THE BARS TO BE EXTENDED INTO REVI EW ED THE NEW CONSTRUCTION. THIS EXTENSION SHALL BE 30 BY BAR DIAMETERS, UNLESS OTHERWISE NOTED. 3. CUT EXISTING REINFORCEMENT TO THE REQUIRED BAR EXTENSION. 4. IF IT WILL NOT DAMAGE THE CONCRETE TO BE LEFT IN Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E PLACE,THE REMAINING CONCRETE MAY BE REMOVED BY ANY SUITABLE METHOD UPON APPROVAL OF THE ENGINEER WHO SHALL BE THE SOLE JUDGE OF THE USE OF ANY CONCRETE REMOVAL EQUIPMENT. HOWEVER, EXPLOSIVES OR A WRECKING BALL (OR OTHER SIMILAR DEVICE) WILL NOT BE PERMITTED. Los Angeles County Department of Public Works COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE DRAFTER T S CIVIL A T E OF MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. DATE PACOIMA SPREADING GROUNDS E IN R EGIS TE R E J.LI 60% PLANS G CHECKER Unofficial and Subject to Change N CHARLES C.CHEN PRELIMINARY E DESI GNER The Information Shown Hereon is R FO I L CA GENERAL NOTES, INDEX TO STANDARD PLANS, DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.2 SHEET 2 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:27:16 AM H I A W C H A L IN K F E N S T . C E 94 0 93 5 Elec. +Exist tower 94 0 SCE EAS EM E NT K F E N + Exist Elec. towers 8 92 0 935 9 3 0 V A L V E 0 94 FENC E E L Exist interbasin structure 24" inlet pipe 2-48" inlet pipes 39" inlet pipe A N C TOWER S IO IN L IN K F E N IV E R 9 4 0 A C E * C H Outlet structure 24", 2-48" & 39" pipe A V E 935 N TOWER 9 3 5 F e n c e N * S T . 9 4 0 C h a in lin k H F E N C E 945 LI NE EAS EM ENT I NLI NK C H A I N L I N K 9 3 0 F L. A.T RAN SM I SSI ON E C K # Exst Radial Gate 9 3 5 5 C h a in lin k D F e n c e A F E N C E C H F E N C E LE TA C H A I N L I N K C H A I N L I N K A I N L 43 F 926. LI N C E P A C FE N # power pole O K +Exist V A L V E Exist Spillway 9 4 0 L 65 F . 931 C H A I N LI N K FE N C E C h a in lin k 94 0 93 5 F e n c e 92 9 3 0 5 2 93 0 5 TOWER 4 92 5 93 + Exist Elec. tower 3 0 94 CI TY O IN L CHA 1 3 9 CI TY OF L. A.PI PEPLI NE EASEMENT IN 5 A S I G (2 N ) F E N C E E R 0 AVE N E F 3 9 T T W O O DM AN 95 5 95 0 5 92 BY S T . 4 9 T O W 0 93 DATE P A X T ON H C 5 5 92 C h a in lin k I N LI NK 920 F e n c e FE NC E # TOWER 15 9 910 5 Exist spillway V A L V E DESCRIPTION OF WORK Remove existing pipe concrete structure and embankment # 93 0 92 5 CHA * C h a in lin k F e n c e 15 9 + Remove existing inlet and outlet structures. Seal end of conduit and abandon in place. Protect in place. 93 SCE EASEMENT 935 LEGEND 930 CHAI NLI NK FENCE 2-24" outlet pipes Elec. towers 93 0 925 +Exist TOWER REVI EW ED 965 5 3 9 E L E C S I G N #Exist Spillway 905 Pacoi m aSGEnhancem ent . dgn 995 980 990 985 970 975 C h a in lin k L 22 F 938. Exist gate 5 5 92 0 92 93 0 910 905 0 I NLI NK 92 CH A Exist gate 93 92 5 0 935 FENC E C h a in lin k 925 930 900 CADD PROJECT FI LE NAM E 990 995 I DI S I G N G P Structure * 5 4 9 0 4 9 5 5 9 S I G N S I G N 0 E T A T S E # Exist overflow 0 5 9 0 4 9 L 36 F 938. L 31 F 938. S I S GN I G N 92 . R I C 935 920 920 V A L V E 5 99 I D 5 4 9 0 5 9 K N LI N I A H C F e n c e S I G N 5 L 76 F 903. Exist gates 5 95 E C N FE L 5 F 1 938. 0 93 G U Y S Elec. +Exist towers 8.8’x3’ +Exist outlet culvert 92 0 91 905 M O I S S I N 5 90 5 91 S L L I H S I G N G P Exist gate Exist power pole D R A U G Elec. +Exist towers 915 0 91 Exist conc. 92 NK FENCE N LI CHAI L 27 F . 901 L 80 F 903. L 98 F 899. G A T E D 0 RD A GU S T S O P EET STR DER UN G P 915 905 9 1 0 L 26 F . 901 0 90 L 6 F 1 948. L 80 F 946. 2 9 T VER L CU S ST PO Exst underpass culvert 910 90 5 910 0 91 CH A I NLI N K FEN CE Modify 60" inlet pipe w/ trash rack 9 0 5 + G U Y I 5 925 920 915 920 S I G N + 915 CH AI NLI NK FEN CE 905 L 82 F 903. C h o a n in to lin p k o Fe f n W ce a ll D 2 9 0 925 CH AI NLI NK F ENCE Exist conc. gutter # 930 E RET CONC ER T T V-GU C H A I N L I N K structure E T 3 9 S ST GUARD PO GUARD POSTS # Existing overflow C o ha n in C lin / L k o Fe f n W ce a ll K N LI N I A H C CHAINLINK FENCE L 65 F 930. # B u C tt h a re in ss lin C k o ha f n in ( or F e to lin 1 n e Flo c p k a e o o Fe ch d f g n W ce sid at a e e ll ) 5 95 935 L 03 F 8. 91 O N C / M P E A T D A L L I D G P G G P P G P G U Y S I G N 935 C W 950 V G V L 1F 1 944. G U Y GATE *10 #Exist conc. L 1F 1 944. V W E C N FE L 36 F 947. G U Y S I G N C o ha n in C lin / L k o Fe f n W ce a ll 945 V a lv e s G A T E G U Y 9 3 0 9 3 5 s k wal Cat L 0 F 1 944. W S I G N L 20 F 947. F E N C E # L 56 F 943. L 74 F 943. p) y t umn ( Col L 08 F 944. P o st s C H A I N L I N K L 51 F 943. Y L 5 8 9 F E N C E A F E N C E structures CHAI NLI NK FENCE G u a rd 945 Outlet structure 11 G U Y C H A I N L I N K 940 910 + Exist power poles power poles +Exist along easement V A L V E N K FEN CE NLI CHAI L 21 F 5. 91 12 + Exist Chevron vent pipe V a lv e s +Exist diversion C H A I N L I N K G * S I G N 5 93 V A L V E GATE 940 # Exist spillway # Exist Spillway Exist interbasin structure L 66 F 938. Exist gate 935 S I G N L 32 F . 901 L 34 F 938. 935 D E V O N S H I R E G P L 42 F 938. 5 94 CE FEN l e n n a h c n o i s r e v i d t s i Ex 950 L 61 F 938. 93 5 940 CITY OF L.A. MINOR EASEMENT # Exist Spillway 7 8.5’x3’ +Exist outlet culvert CHAI NLI NK F ENCE Exist Elec. towers NK I NL AI CH CHAINLINK FENCE 0 93 + 9 2 5 C o ha n in to lin p k o Fe f n W ce a ll 955 950 C h o a n in to lin p k o Fe f n W ce a ll DI 935 F E N C E CE FEN G U Y 94 0 C E C H A I N L I N K E NC FE G U Y NK I NL AI CH 945 FE N * 935 LK FE NC E Exist gate 6 935 H CH AI NL I NK 940 C S I G N 94 0 V A L V E Outlet structure 91 5 935 LK CH ARLETA C H A F E N C E IM C E F E N IN L IN K C H A I N LI N K .I . G A T E Exist Spillway 925 9 15 W CE FEN NK I NL AI CH N K FENCE NLI CHAI # 9 2 0 Exist gate Exist gate Modify Exst diversion structure GATE 9 #Exist Spillway A R O W C E 0 2 9 * 920 9 4 0 DI L IN O IN Exist interbasin structure 38" Inlet pipe 24" gated pipe S I G N 94 5 5 D A 92 0 O N C / M P E A T D A L L I D 93 C H F E N P C O E S T S C W DI 9 3 0 9 2 5 93 5 V A L V E AVE 9 3 0 M A N F E N C E G U Y PIPE CORRIDOR 15 9 C H A I N L I N K E NC FE PIPE CORRIDOR NK I NL AI CH FE NC E PIPE CORRIDOR S T . MI S S I ONHI L L S CH AI NL I NK 94 5 I C V PIPE CORRIDOR A T H A T U B A FE NC E IN S T . CH AI NL I NK 5 93 PIPE CORRIDOR K PIPE CORRIDOR A V E B L A C K H A W C o w nc / M e Pa ta d l Li d 910 F e n c e 905 L 46 F 933. C h a in lin k S T . 9 3 0 W F e n c e L 21 F 933. ro u g h t NOTES: Ir o n F e n c e o o d e n F e n c e 2. Protect in place all power poles and electric towers The Information Shown Hereon is PRELIMINARY Unofficial and Subject to Change 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE T S CIVIL A T E OF MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. DATE PACOIMA SPREADING GROUNDS E IN R EGIS TE R E PLAN SCALE:1"=200’ DRAFTER Los Angeles County Department of Public Works 1. See Tower Cross Sections on Sh xx. W AVE 92 5 W O O DALE BEACHY BO RDEAUX AVE G ULLO AVE J.LI 9 2 0 G CHECKER CHAINLINK FENCE FILMORE 91 5 N CHARLES C.CHEN CHAINLINK FENCE 91 0 E DESI GNER ST. CANTERBURY FILMORE 90 5 AVE CHAINLINK FENCE 900 AVE NCE E NK F I NL CHAI R FO I L CA SITE PLAN EXISTING FACILITIES DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.3 SHEET 3 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 11:26:03 AM H B OS I B E H B OS I B E 93 5 9 3 4 94 2 94 3 94 6 AVE 9 3 3 5) 93 3 93 4 93 6 ARLETA 93 2 94 7 S= 0. 001 9 3 2 P 3 93 0 93 1 (S H 92 7 92 8 94 5 93 8 9 3 1 SCE EAS 93 8 EM ENT 930 929 92 6 92 6 92 1 C E F E N K L IN A H C 94 4 5 95 L 6 F 1 948. G A T E 93 9 Exist gates E C N FE K N LI N I A H C Exist gate 5 4 9 0 5 9 0 5 9 0 4 9 5 4 9 0 4 9 Control House See Sh 19-23 5 5 9 C h a in lin k F e n c e V P ert ip e 3 94 94 0 935 001 S = 0. E L F e n c e A N H N S IO IN L IN F E N IV E R K C E RIP RAP 3 9 0 3 9 5 94 3 C h a in lin k F e n c e D C H A I N A IM F E N C E F E N C E LE TA C H A I N L I N K C H A I N L I N K L 43 F 926. LI N C E A R 9 4 0 L 65 F . 931 P A C FE N op 24" CMP T m 9 Ri 1 942. C H 3 4 9 A I N K P 5 LI N FE N C E C h a in lin k 94 93 5 F e n c e 92 9 3 0 EL 922.84 93 0 5 S6 92 5 93 5) 0 BASIN 1 P6 WSE 932 Bot El 918 (Sh 7) (SH 5)P6 3 94 (S H 5 TOWER TOWER BASIN 2 WSE 917 Bot El 907 (Sh 7) Interbasin Structure East SB - 1 O K Interbasin Structure 1-2 V A L V E CI TY O C h a in lin k C P 5 94 3 A V E A 9 4 0 C H F L. A.T RAN SM I SSI ON 945 94 3 935 94 2 Diversion gate Rubber Dam N 933 S= 0. 001 930 CONC CONC LI NE EAS EM ENT FENC E 5 92 0 93 S T . op 30" CMP T m 30 Ri 944. E C K Transition to exst 8.5’W x 3’H RCB 94 4 94 2 IN L 9 4 5 F E N C E 9 3 5 IN I NLI NK 9 3 5 C H A I N L I N K 94 1 9 3 5 A 5 H B OS I B E N E F H C CHA op 24" CMP T m 78 Ri 942. 9 4 0 5 TOWER CI TY OF L. A.PI PEPLI NE EASEMENT S T . L 5 F 1 938. 0 9 1 9 P A X T ON ROCKS A N O 93 8 965 G U Y ROCKS O W IN 92 9 ROCKS 93 7 970 P 3 980 990 28 GB 956. 95 0 F E N C E E R 92 AVE 995 44 GB 956. DIRT PILE 975 CHAI NLI NK FENCE 4 9 940 938 935 T O W 9 3 0 920 BY ROCKS 43 GB 956. P 86 T . 961 Exst access ramp P P GATE 9 93 5 3 9 932 928 DATE K N LI N I A H C 0 929 930 931 C H A I N L I N K E L E C G U Y S EAST SETTLING BASIN WSE 941 Bot El 929-931 (Sh 9) 5 0 94 94 2 SCE EASEMENT C h a in lin k F e n c e E TOWER 15 9 6 91 910 15 9 5 91 H B OS I B E 920 FE NC H B OS I B E 93 0 92 5 I N LI NK V A L V E 9 3 9 9 3 8 CHA 8 91 H B OS I B E 7 91 W O O DM AN 935 EL 904.91 Interbasin Structure 2-6 930 S8 H B OS I B E 93 0 925 H5 ) 910 9 4 1 9 4 0 5 92 H B OS I B E TOWER 9 3 7 C h a in lin k F e n c e 93 6 93 5 5 92 0 92 93 0 910 905 0 I NLI NK 92 CH A Exist gate H B OS I B E 93 92 5 0 935 FENC E 6 3 9 C h a in lin k 925 6 93 H B OS I B E 935 H B OS I B E 933 H B OS I B E 4 93 H B OS I B E 932 H B OS I B E 931 H B OS I B E 930 H B OS I B E H B OS I B E 929 H B OS I B E CHAINLINK FENCE 928 927 H B OS I B E 926 H B OS I B E 925 H B OS I B E 924 H B OS I B E 923 H B OS I B E 922 H B OS I B E CHAINLINK FENCE 921 H B OS I B E 930 920 H B OS I B E H B OS I B E 918 H B OS I B E 917 H B OS I B E 916 H B OS I B E 915 B S I B E 914 905 HO 912 910 913 3 S " ta W n d at p e ip r e 911 48" RCP gh 9’Hi . 1 H B OS I B E H B OS I B E L 46 F 933. C h a in lin k S T . 9 3 0 W F e n c e L 21 F 933. ro u g h t Ir o n F e n c e W Los Angeles County Department of Public Works o o d e n F e n c e AVE 92 5 AVE AVE 91 5 W O O DALE FILMORE 9 2 0 BEACHY 91 0 F e n c e H B OS I B E CHAINLINK FENCE BO RDEAUX AVE G ULLO AVE ST. CANTERBURY FILMORE 90 5 C o w nc / M e Pa ta d l Li d The Information Shown Hereon is PRELIMINARY Unofficial and Subject to Change 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS SITE PLAN S S I E O NA OF L PR D N G CIVIL A * 06/30/12 T E OF I A T S VI SAL TE C63209 N EXP. ENHANCEMENT PROJECT ER * MK E IN CHARLES C. CHEN NO. DATE PACOIMA SPREADING GROUNDS E SCALE:1"=200’ R EGIS TE R E REVI EW ED E C N FE 08 GB 956. C h o a n in to lin p k o Fe f n W ce a ll C o ha n in C lin / L k o Fe f n W ce a ll 985 N K FEN CE NLI CHAI 945 5 94 2 4 93 P7 ( S 905 Pacoi m aSGEnhancem ent . dgn E T P 28 T 967. 40 GB 956. L 22 F 938. 92 9 2 2 9 2 1 9 2 0 24" CMP gh 2’Hi . 1 CHAI NLI NK FENCE CADD PROJECT FI LE NAM E A V A U L T Install flow meter 95 5 S4 915 E T A T S E 900 J.LI G 47 GB 956. F e n c e L 36 F 938. S7 900 CHECKER C h a in lin k C o ha n in to lin p k o Fe f n W ce a ll 73 GB 956. EL 918.52 NCE E NK F I NL CHAI CHARLES C.CHEN P 34 T 960. 995 5 95 P P H B OS I B E G U Y 990 P P 950 V a lv e s 935 EL 927.27 V A L V E H B OS I B E DESI GNER G V . Double 54" RCP 945 H B os ib e s P P V COMP 3 95 4 95 1 95 2 95 C o ha n in C lin / L k o Fe f n W ce a ll 41 GB 956. G U Y W P P 50 GB 956. P P L 31 F 938. 24" RCP gh 8’Hi . 1 DRAFTER 7 95 956 955 CHAI NLI NK F ENCE GATE L 08 F 944. P P V P P G u a rd ra il P P op 30" CMP T m 72 Ri 955. 920 24" CMP gh 0’Hi 1 H B OS I B E 940 2 9 0 EET STR DER UN 9 3 8 92 L 76 F 903. 0 91 P7 L 1F 1 944. M Li et d a s l (3 ) CHAINLINK FENCE 9 4 0 927 0 91 36" CMP L 0 F 1 944. L 1F 1 944. W P BF H B OS I B E 935 0 93 926 L 80 F 903. L 98 F 899. gh 5 Hi ’ 3 0 9 . R I C E RET CONC ER T T V-GU 5 91 M O I S S I N L 27 F . 901 905 S L L I H 925 9 1 0 L 26 F . 901 925 NK FENCE N LI CHAI P8 S5 EL 911.05 918 ) 6 9 0 5 0 90 930 L 03 F 8. 91 O N C / M P E A T D A L L I D 0 2 9 924 90 5 910 0 91 CH A I NLI N K FEN CE L 82 F 903. W 935 923 905 24" CMP gh 0’Hi 1 H B OS I B E L 56 F 943. L 74 F 943. L 80 F 946. G U Y L 65 F 930. 920 915 910 CH AI NLI NK FEN CE V A L V E 36" CMP gh 3’Hi SH ( P8 920 915 915 905 H B OS I B E L 32 F . 901 945 0 94 940 3 9 925 CH AI NLI NK F ENCE W R AT I S E E R R S 9 1 4 9 1 0 L 51 F 943. op 24" CMP T m 3 Ri 955. 956 5 99 2 9 24" CMP gh 3’Hi . 1 C H B OS I B E 9 1 1 935 910 S3 EL 904.16 H B OS I B E Exst 60" RCP overflow outlet pipe 7 5 9 32 GB 952. V a lv e s G U Y 9 3 0 T VER L CU 9 1 2 L 66 F 938. A " a bo Pi n v p d e e 30" CMP gh 3’Hi 3. L 20 F 947. 9 3 5 F E N C E 50 GB . 951 950 L 42 F 938. 5 8 9 C H A I N L I N K 4 GB 1 954. 9 5 8 01 GB . 951 V G a n V u d e lt n s t F E N C E 71 GB 954. H B os ib e H B os ib e B F P L 61 F 938. 93 5 G A T E C H A I N L I N K NK I NL AI CH C o ha n in to lin p k o Fe f n W ce a ll P P 38 GB 953. L 36 F 947. F E N C E 95 8 85 GB 955 956. 5 94 48 GB 955. CE FEN CHAINLINK FENCE H B OS I B E 18 G U Y C H A I N L I N K H B OS I B E H B OS I B E 940 5 93 S T A N D P I P E Interbasin Structure 5-6 9 95 6 GB 1 956. 950 9 4 7 Protect in place exst 8.5W X 3’H RCB 2 4 " H B OS I B E BASIN 6 WSE 908 Bot El 898 (Sh 6) P2 Interbasin Structure 4-5 EL 915.83 G U Y CE FEN G U Y C h o a n in to lin p k o Fe f n W ce a ll Exist gate 1 0 0 . 0 = S E NC H FE B OS I B E P P NK I NL AI CH L 34 F 938. Interbasin Structure 3-4 LK CH H B OS I B E EL 934.64 935 S2 V A L V E Exist gate Double 54" RCP S1 H B os ib e P4 9 1 3 West SB - 3 V A L V E .I . G A T E N K FENCE NLI CHAI 5) P 2 24" CMP gh 8’Hi 2. L 21 F 5. 91 W CE FEN NK I NL AI CH 935 9 3 0 GATE 935 0 93 ( SH 9 2 5 H B OS I B E H B OS I B E 935 V A L V E y MH t i l i Ut m 34 Ri 935. P4 ) SH5 ( Exist gate 94 0 C E 9 1 9 92 0 H B OS I B E 935 940 FE N BASIN 5 WSE 916 Bot El 905 (Sh 8) CITY OF L.A. MINOR EASEMENT H B OS I B E 92 92 1 0 P P 94 5 9 4 0 935 LK 9 1 9 H B OS I B E Intake manifold headwall P P WEST SETTLING BASIN P1 WSE 941 Bot El 929-931 (Sh 9) Interbasin Structure ( SH 5 ) 94 0 H 0 2 9 H B OS I B E H B OS I B E F E N C E P P V A L V E 5 C D E V O N S H I R E H B OS I B E y MH t i l i Ut m 26 Ri 932. P1 Proposed access road 93 5 93 F E N C E C H A I N L I N K FE NC E IN C H A I N LI N K H B OS I B E CH AI NL I NK A C E 9 15 F E N 0 2 9 G U A R D R A I L S y MH t i l i Ut m 34 Ri 935. 925 91 5 BASIN 4 WSE 924 Bot El 914 (Sh 8) 7 92 920 K 92 0 O N C / M P E A T D A L L I D L IN 928 C W C H D 9 2 5 y MH t i l i Ut m 55 Ri 929. Transition to exst 8.5’W x 3’H RCB FE NC E ROCKS M H B OS I B E CH AI NL I NK 94 5 PLC 9 3 0 94 0 BASIN 3 WSE 936 Bot El 922 (Sh 9) APC S T . 937 (D Irr is iga c o tio n n n e c Lin te d e ) 9 3 0 9 2 0 H B OS I B E H B OS I B E F E N C E G U Y 94 1 IN C E C H A I N L I N K E NC FE 940 A F E N 15 9 H B OS I B E H B OS I B E H B OS I B E 6 3 9 NK I NL AI CH H B OS I B E H B OS I B E 94 0 5 3 9 S T . FE NC E 93 5 H B OS I B E I C V 9 93 C H K H B OS I B E A T H A T U B A MI S S I ONHI L L S L IN S T . CH AI NL I NK R LE BB BU H I A W 5 93 ROCKS K CONC A V E B L A C K H A W R FO I L CA SITE PLAN IMPROVEMENT FACILITIES DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.4 SHEET 4 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 12:41:27 PM Q = 300 cfs Q = 300 cfs 51’ Q = 300 cfs SCE Easement 20’ 28.0’ 100’-0" 35.36’ 4" AC on 6" CMB 76.6’ 5’ 14’ El 93 3. 0 930 TW Exist AC Exist AC 4" AC on 6" CMB 28.89’ 920 TW Existing ground line TW Existing ground line TW 0 8. 91 Bot El 922 WSE 916 5 . 4 Bot El 905 91 Finish grade 0 6. 92 930 Basin 4 WSE 924 5 2. 92 Inlet "I" (Sh 21) El 92 2. 0 Bot El 914 920 Inlet "I" (Sh 21) Bot El 898 72 " To W po b t ho e l ed 910 Unclassified Outlet Structure (Sh 20) Inlet "I" (Sh 21) Unclassified Unclassified excavation 920 5 6 0 8 0 . 0 S= 81’ 910 28.5’ 72"RCP, 2000D Rubber Gasket Joint 910 PROFILE P1-P1 99’ Unclassified 34.5’ (SH.4) STRUCTURE WEST SB-3 72"RCP, 2000D Rubber Gasket Joint excavation 9 9 4 3 0 . 0 S= 900 1 0 9 3 0 . 0 S= 21.5’ 5 93 09 . 0 S= E l8 9 8 .0 excavation El 90 5. 0 93 89 0 . 0 S= 21.5’ E l9 0 5 .0 WSE 908 930 excavation 920 El 91 4. 0 Inlet "I" (Sh 21) Outlet Structure (Sh 20) Outlet Structure (Sh 20) Basin 6 Unclassified El 92 9. 0 Outlet Structure (Sh 20) Basin 5 940 excavation E l9 1 4 .0 20’ 5 4. 93 Finish grade Finish grade El 91 8. 0 TW Basin 3 WSE 936 Unclassified fill Unclassified fill Finish grade Existing ground line Unclassified fill 53.89’ TW 0 8. 93 E l9 2 2 .0 Q = 300 cfs 20’ 0 3. 94 West Settling Basin TW 5 WSE 941 9. 93 Bot El 929 TW Existing ground line 940 5 . 34 9 El Exist AC 5’ El 93 8. 0 R/ W Devonshi r e St . 940 R/ W Exist CLF Exist CLF El 94 4. 0 SCALES: HOR: 1"=40’ VERT: 1"=8’ 900 PROFILE P2-P2 (SH.4) STRUCTURE 3-4 249’ 21.5’ 890 106’ 21.5’ 29.5’ SCALES: Jack 72"RCP, 2000D Rubber Gasket Joint 29.5’ 72"RCP, 2000D Rubber Gasket Joint PROFILE P3-P3 HOR: 1"=40’ VERT: 1"=8’ (SH.4) STRUCTURE 4-5 HOR: 1"=40’ VERT: 1"=8’ SCALES: STRUCTURE 5-6 HOR: 1"=40’ VERT: 1"=8’ 100’-0" Devonshi r e St . SCALES: Q = 300 cfs Exist CLF R/ W DATE 4" AC on 6" CMB 14’ El 94 3. 0 Q = 300 cfs 100’ 6’ 15’ 950 Exist CLF R/ W PROFILE P4-P4 (SH.4) Exist AC TW Finish grade SCE Easement TW Existing ground line 30’ El 93 4. 0 Existing 20’ 5’ TW ground line TW BY Unclassified fill 65’ Pipeline Easement Finish grade 920 20’ 5’ TW TW Existing ground line Basin 6 Unclassified fill WSE 908 Bot El 898 910 0 9. 91 5 5. 91 Basin 2 WSE 917 920 920 excavation Inlet "I" (Sh 21) 910 68 10 . 0 S= 208’ 21.5’ E l8 9 8 .0 900 103’ PROFILE P5-P5 34.5’ excavation PROFILE P6-P6 278’ 29.5’ Jack 72"RCP, 2000D Rubber Gasket Joint The Information Shown Hereon is SCALES: HOR: 1"=40’ VERT: 1"=8’ PRELIMINARY (SH.4) Unofficial and Subject to Change STRUCTURE 1-2 SCALES: HOR: 1"=40’ VERT: 1"=8’ 60% PLANS (SH.4) COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR E IN CHARLES C. CHEN * EXP. C63209 * 06/30/12 T S CIVIL A T E OF ENHANCEMENT PROJECT I A NO. ER R EGIS TE R E PACOIMA SPREADING GROUNDS G HOR: 1"=40’ VERT: 1"=8’ D N STRUCTURE 2-6 N PROFILE P7-P7 Los Angeles County Department of Public Works (SH.4) STRUCTURE EAST SB-1 72"RCP, 2000D Rubber Gasket Joint VI SAL TE 910 28.5’ Jack 72"RCP, 2000D Rubber Gasket Joint E J.LI 2 0 4 5 0 . 0 S= 9 8 3 3 0 . 0 S= SCALES: DRAFTER 30 Unclassified Unclassified fill Unclassified 21’-6" Inlet "I" (Sh 21) El 9 1 8 . 0 Outlet Structure (Sh20) El 90 7. 0 Inlet "I" (Sh 21) Finish grade 21’-6" CHECKER El 92 9. 0 excavation 900 CHARLES C.CHEN Bot El 915 Unclassified Outlet Structure (Sh 20) DESI GNER excavation WSE 932 Outlet Structure (Sh 20) Bot El 907 4" AC on 6" CMB 72 " To W 4" AC on 6" CMB pot be ho l ed Bot El 929.0 Unclassified Unclassified fill Unclassified E l9 0 7 .0 Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E El 91 7. 0 20’ WSE 941.0 DWP Easement 11’ excavation 5’ Basin 1 East Settling Basin 940 930 110’ 62.2’ 5 0. 93 5 9. 93 Exist AC E l9 1 8 .0 REVI EW ED Q = 300 cfs 0 4. 93 0 3. 94 R FO I L CA INTERBASIN CONDUITS 72 IN. RCP DATE MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.5 SHEET 5 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:29:24 AM Q = 200 cfs 920 Curb and Gutter-Mountable per Std Plan 121, D2-150(6) 920 32’ 5’ 6" Finish grade 4" AC on 6" CMB Unclassified fill TW Basin 6 WSE 908 5 6. 89 Bot El 898 910 6"CMB Backfill Anchor pipes @ 15’ Max Top of slope 4"AC on ~ 12" 910 TW 8" R/ W 4’-6" 0 91 6" 102’ S=0 24" 3 : 1 5’-0" 6" Existing ground line Inlet "I" (Sh 21) 900 outflow 5 4 8 0 . 0 S= 10" C P 10" 6" E l8 9 o 3 n c. .24 C o l l a r excavation Rip rap, Light Class ~ 68’ 890 29.5’ 24" Half CSP Curb and Gutter-Mountable per Std Plan 121, D2-150(6) 60"RCP, 2000D Slurry backfill C Protect in place PROFILE Bedding Slurry 100-E-100 R Unclassified 2 0 5 0 . 0 S= 890 ~ Remove exst 24" 900 12" 6’-0" Toe of slope Down Drain Inlet exst 60" RCP ~ HOR: 1"=40’ VERT: 1"=8’ ng hi t r ng No t i s a E FL g n i h rt ng o i st a E 0 1 9 90 0 ~ N 5 0 9 Basin 6 WSE 908 Bot 898 ~ 24" Half CSP Inlet 8’ 0" 0 0 9 8 9 8 Down drain DDx See down drain table hereon for coordinates Concrete Down Drain Rip rap, Light Class 10’ 0" NOT TO SCALE STRUCTURE 6-DRAIN SCALES: (SH.5) Toe ofsl ope TYPICAL PIPE BEDDING (SH.4) Top ofsl ope PROFILE P8-P8 Anchor pipes 6" ’ 5 2 5’-0" Length See table hereon 5’ 0 1 9 DATE HOSE BIB Note: For downdrain locations see Sh 6 through 11 PLAN 32 ’ 6 8 ’ 6 0 " RCP, 2 0 0 0 D Se ePr o f i l eP8 P8 h e r e o n BY REVI EW ED 5 0 9 TYPICAL DOWN DRAIN DETAIL NOT TO SCALE Pacoi m aSGEnhancem ent . dgn 4 0 9 CADD PROJECT FI LE NAM E Exst R/W HOSE BIB 20" Pacoima Wash Unit 6, Lateral "E", 60" RCP PLAN STRUCTURE 6-DRAIN SCALES: 1"=20’ Los Angeles County Department of Public Works COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE T S CIVIL A * 06/30/12 T E OF I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. DRAFTER PACOIMA SPREADING GROUNDS E IN R EGIS TE R E J.LI 60% PLANS G CHECKER Unofficial and Subject to Change N CHARLES C.CHEN PRELIMINARY E DESI GNER The Information Shown Hereon is R FO I L CA DISCHARGE CONDUIT 60 IN. RCP DATE MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.6 SHEET 6 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 2:04:19 PM CHAI NLI NK FENCE LACFCD RW Exst access road SIGN 15’ 42" 45" 920 920 919 920 Exst access road 20’ 28" Exist CLF 36" 26" 5 91 30" CH LK CE FEN 5 0 91 90 BASIN 5 WSE 916 Bot El 905 (Sh 9) 8 89 30" PALM 12" Unclassified excavation 900 900 Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 1 6 24" 910 Finish grade 6’ A 1 3: W O O DM AN NK I NL AI CH 5 91 I NT ERBASI NST RUCT URE5 6 8 4 . 8 3 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP4 P4o nSh . 5 E NC FE BASIN 6 WSE 916 3: 1 910 18" Exst ground line ayer ay l Cl 30" Exst access road STREET R/ W WEI RST RUCT URE Se eDe t a i l o nSh . 1 3 El. 898 Clay layer to be removed and replaced with unclassified fill 890 890 AVE 40" SECTION A-A 30" 6 1 . 4 0 9 0 91 3 S L E 5 90 8 89 1004 904.16 Dirt S3 5 91 0 91 9 15 5 90 5 91 12" OAK ’ 0 2 d a ro C A SCALES: HOR: 1"=200’ VERT: 1"=8’ ’ 5 2 92 1 92 0 92 9 91 ’ 5 9 15 9 10 102 932.88 Control 9 0 5 0’ ne 11 fLA Li o n y o t s i t Ci i s n m me s e n s a Tr Ea 32" VALVE 10" Ex s t P. P. 10" 16" 10 9 BASIN 2 WSE 917 Bot El 907 (Sh 8) 16" CONC 104 918.44 Control C H A N I N LI 8 91 K ’ 60 A L f ne t o i y L en t i e C i p m P se a E N FE 16" C E 14" WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 H C Basin 6 WSE 908 Bot 898 A IN IN L K N E F DATE E C I NT ERBASI NST RUCT URE2 6 2 6 5 . 5 6 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP7 P7o nSh . 5 CONC 4 91 5 90 91 5 8 89 0 91 91 5 9 1 8 A N I N LI K N FE 9 1 7 Re mo v ee x s t o v e r f l o ws t r u c t u r e 2 91 E C BY R E H C 18" 24" 8" 9 0 5 ’ d 20 r oa C A 10 9 A IN Re mo v ee x s t o v e r f l o ws t r u c t u r e E C N E F IN L K N E F K N I L N I A H C C E 6" V N G W T S 3 91 M L I F 2 1 9 5’ V N G E V A 1 91 0 91 N A 4 1 9 T E E R T S C N A 20" U B R E E T AV M Y D 0 1 9 5 8 0 9 9 8 R O 6 8 ’ 6 0 " RCP, 2 0 0 0 D Se ePr o f i l eP8 P8o nSh . 6 E R O Los Angeles County Department of Public Works V N G O 90 0 20" 16" 32" The Information Shown Hereon is 905 20" PRELIMINARY ’ 5 1 O A A IN K N E V U COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS 20" N E F K V N G O L L 102 932.88 Control 8" 6" 20" * V N G G EXP. T S 20" VI SAL TE 24" 0 0 9 C63209 PACOIMA SPREADING GROUNDS CIVIL A T E ENHANCEMENT PROJECT * 06/30/12 OF 24" V N G DRAFTER CHARLES C. CHEN NO. U 24" 24" D ER 18" 20" 20" IN L E IN 12" 8" H C IN G 12" A N 10" E 15" S S I E O NA OF L PR E C I A 10 9 SCALE: 1"-100’ 60% PLANS V N G 5 0 9 E PLAN O N E C A V N G N E F N 20" M L I F R EGIS TE R E A IN L M 5 0 9 Unofficial and Subject to Change E R E V A D H C O 10 9 V N G W J.LI 0 91 20" Pacoima Wash Unit 6, Lateral "E", 60" RCP CHECKER ’ 5 5 1 9 Pacoi m aSGEnhancem ent . dgn 91 0 91 0 V N G 15" T 0 91 WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 6 1 9 5’ 15" 9 0 5 H C CADD PROJECT FI LE NAM E T 0 91 ’ 0 d 2 a ro C A 7 1 9 1 91 9 1 5 0 91 5 90 12" 1005 904.91 Dirt S8 8 1 9 905 5 0 0 9 1 9 5 8 1 9 9 8 8 0 9 12" 15" 1 9 . 4 0 9 8 S L E 5 0 9 40" 8" CHARLES C.CHEN Hi g hVo l t a g e T o we r s 9 1 6 12" DESI GNER W O T Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 18" R E REVI EW ED 91 5 W O T 3 91 VALVE 91 0 9 0 5 R FO I L CA EXCAVATION AND GRADING PLAN - BASIN 6 DATE MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.6 SHEET 7 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:30:20 AM D E V O N S H I R E S T R E E T 1 2 " G U Y S E L E C T O W 2 4 " 0 C H A I N L I N K 1 8 " 1 4 " 1 6 " 4 9 3 " 1 5 " 1 4 " F E N C E op 24" CMP T m 78 Ri 942. E R Ex s t T o we r H B OS I B E 1 4 " 8 " 3 6 " 1 4 " 9 4 0 1 2 " 9 3 8 5 92 94 1 0 93 7 1 9 C H A I N L I N K 9 3 5 9 4 0 7 0 9 1 6 " 2 4 " 9 3 52 6 " TOWER TOWER 9 3 0 5’ 94 2 2 4 " 8 " 2 0 " 2 0 " I NT ERBASI NST RUCT URE Ea s t Se t t l i n gBa s i n1 2 0 3 . 6 2 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP5 P5o nSh . 5 3 2 " RIP RAP 0 3 9 DENSE TREES G N V 3 9 2 6 " 94 3 5 3 2 " 93 0 93 92 5 0 92 5 13 ’ 2 4 " 2 8 " S T op 24" CMP T m 9 Ri 1 942. 2 4 " WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 9 4 0 3 1 2 " 2 " 1 5 " 1 2 " 1 6 " 2 4 " 2 0 " 2 0 " C H Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 A A I N LI N K SCE EASEMENT S T R E E T V E N A R CI TY O 93 5 93 0 9 3 0 92 5 93 5 92 5 EL 922.84 2 0 " 3 94 Bot 918 2 0 " TOWER 0 91 V A L V E 0 S6 Basin 2 WSE 917 Bot 907 94 1 5 " 1 0 Di 0 9 r t 9 S 22 6 . 84 I NT ERBASI NST RUCT URE1 2 Basin 1 1 8 0 . 8 3 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP6 P6o nSh . 5 WSE 932 C E E FE N U Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 2 4 " F E N C E R LE TA 918 V A L V E 91 8 2 6 " C H A I N L I N K A 925 20’ 920 930 S t r u c 2 B C - tu 1 O 2 r N D C e 1 0 1 . 1 6 D E V O C N H A I S N L I H N K I R F E N E C E 3 4 9 F L. A.T RAN SM I SSI ON 4 2 " 9 4 0 925 915 907 LI NE EAS EM ENT 930 920 910 920 915 907 910 4 8 " 1 4 " Ex s t P. P. 5 91 905 C S O N t C r u c 2 B t 1 u 4 r D e 1 0 1 . 1 6 4 6 " 2 4 " 5 92 918 NK FENCE NLI CH AI Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 4 2 " 1 4 " 1 0 " WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 94 2 2 0 " 915 9 1 9 5 ’ 2 0 ’ Pr o t e c t i n p l a c e Ex s t P. P. Hi g hVo l t a g e T o we r s 2 6 " B 1 St E ru , 2 C ct 1 1 ur D , 5 B e 4 1CMP op 30" T W m 30 Ri 944. 0 92 104 C o nt r 91 o l 8. 4 4 D E V O N S H I R E 2 6 " 1 011 D i r t 9 S 27 4 . 2 7 S t r u c 2 B t 1 u 1 r D e 1 0 1 . 1 4 2 2 " 94 3 5’ EL 927.27 DENSE TREES G N V S4 5 92 9 2 2 9 2 1 9 2 0 1 2 " 3 0 " 923 C 9 " 1 8 " 920 5 1 9 0 1 9 20’ S t r u c 2 t 1 u r D e 1 0 1 C.1 O N6 1 4 " F E N C E 3 0 " EAST SETTLING BASIN WSE 941 Bot El 929-931 (Sh 10) 1 4 " 1 2 " A V E 940 938 C LE TA 4 93 1 2 " 1 1 " 48 ’ -1 1. 91 " 933 94 2 1 5 " 2 4 " 935 932 931 928 927 924 S5 EL 911.05 925 5’ 1 0 D 0 i 2 r t 9 S 11 5 . 0 5 9 " 1 8 " 5 2 9 0 2 9 926 0 2 9 930 929 B 2 1 D 5 4 . 4 102 C o n t r 93 o l 2. 8 8 DENSE TREES G N V BASIN 5 WSE 916 Bot El 905 (Sh 9) 918 3’ 3’ 14 ’ TOWER 15 9 ’ 5 907 910 915 22’ 9 2 0 STREET R/ W L 46 F 933. W F e n c e 9 3 0 L 21 F 933. ro u g h t Ir o n F e n c e 935 BASIN 1 WSE 932 AVE W O O DALE AVE BEACHY Exst access road F e n c e H B OS I B E C h a in lin k 92 5 STREET R/ W Exst access road AVE AVE CANTERBURY B 91 5 BO RDEAUX Los Angeles County Department of Public Works PLAN The Information Shown Hereon is SCALE: 1"-100’ BASIN 2 WSE 917 PRELIMINARY excavation 925 Exist CLF Finish grade 1 3: 1 3: Unclassified 3: 1 Exst ground line Clay layer to be removed and replaced with unclassified fill Finish grade Unclassified Unofficial and Subject to Change Exist CLF 3: 1 Pacoi m aSGEnhancem ent . dgn 60% PLANS excavation 910 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS T E OF DATE MK * 06/30/12 I A 5. 5’ R EGIS TE R E HOR: 1"=200’ VERT: 1"=8’ C63209 CIVIL A ENHANCEMENT PROJECT ER EXP. SCALES: E IN HOR: 1"=200’ VERT: 1"=8’ * SECTION C-C PACOIMA SPREADING GROUNDS G SCALES: CHARLES C. CHEN NO. T S SECTION B-B Clay layer to be removed and replaced with unclassified fill D N 915 890 VI SAL TE El. 918 E El. 905 S S I E O NA OF L PR N El. 907 5. 5’ CADD PROJECT FI LE NAM E O A K GNV J.LI 925 CHECKER 920 2 0 " C H B OS I B E F I L MORE ST RE E T Exst access road 920 CHARLES C.CHEN 92 5 93 0 FEN CE H B OS I B E C o w nc / M e Pa ta d l Li d CHAI NL I NK F E NCE ST 93 0 92 0 92 0 CH AI N LI NK 935 6 3 9 H B OS I B E 6 93 H B OS I B E 935 FILMORE H B OS I B E 4 93 91 0 H B OS I B E 933 H B OS I B E 932 H B OS I B E 931 H B OS I B E 930 H B OS I B E CHAI NL I NK F E NCE C h a in lin k O A K 930 929 H B OS I B E 2 0 " 925 928 927 H B OS I B E 926 925 CHAI NL I NK F E NCE H B OS I B E 924 H B OS I B E 923 H B OS I B E 922 H B OS I B E 921 H B OS I B E H B OS I B E 920 918 917 916 915 H B OS I B E 93 5 1 6 " Exst ground line DESI GNER F e n c e 92 5 BY TOWER 15 9 C h a in lin k O A K Exst access road DRAFTER 3 0 " 1 8 " Hi g hVo l t a g e T o we r s 930 F e n c e 9 3 7 1 8 ’ ’ 0 2 F I L MORE ST RE E T C h a in lin k 93 6 Ex s t P. P. H B OS I B E O A K FE NC E 91 5 90 7 S t r u c 2 B t 1 u 3 r D e 1 0 C1. O N1 C 6 91 8 92 5 92 0 93 0 1 5 " I NL I NK 92 5 O A K S CH A DATE 935 91 0 5 91 REVI EW ED 0 94 92 0 V A L V E 920 8 " 9 3 8 930 935 920 925 92 5 2 0 " 3 0 " 930 93 0 93 0 6 91 910 Pr o t e c t i n p l a c e 925 I NT ERBASI NST RUCT URE2 6 2 6 5 . 6 6 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP7 P7o nSh . 5 94 2 9 4 1 9 4 0 9 3 9 2 - 93 0 8 91 905 Basin 6 WSE 908 Bot 898 (Sh. 7) WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 5 92 EL 904.91 Ex s t T o we r S7 EL 918.52 7 91 CI TY OF L. A.PI PEPLI NE EASEM ENT 1 10 008 D 0 i irt 8 r t 91 9 S 18. S7 7 8.5 5 2 R FO I L CA EXCAVATION AND GRADING PLAN - BASIN 1 & 2 DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.8 SHEET 8 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:32:10 AM 940 4" AC on 938 930 2 6 " 938 3: 1 3: 1 12" 93 6 13 ’ LACFCD R/ W El. 907 9 92 1 4 0 El. 905 1 8 " 1 5 " Clay layer to be removed and replaced with unclassified fill 3 0 " 24" CMP gh 3’Hi . 1 2 4 " 2 8 " 930 2 2 " 2 2 " EET STR ER ND TU VER L CU 2 2 " 2 1 D 5 4 . 4 935 2 8 " 2 2 " 900 2 8 " 0 93 8 " 2 1 D 5 4 . 4 102 C on t r 932 o l . 8 8 SCALES: 1 8 " G U Y S 928 5’ HOR: 1"=200’ VERT: 1"=8’ 48 ’ -1 1. 91 " 940 938 930 931 935 4 93 SECTION D-D 9 " 49 ’ -2 .2 1" 933 1 8 " 932 CI TY O 915 9 905 10 905 9 915 10 Finish grade 9 3 5 9 93 F L. A.T RAN SM I SSI ON 915 910 5 90 9 3 0 5 92 0 93 927 926 D 920 Los Angeles County Department of Public Works EL 927.27 TOWER TOWER Pr o t e c t i n p l a c e Hi g hVo l t a g e T o we r The Information Shown Hereon is BASIN 2 WSE 917 Bot El 907 (Sh 8) PRELIMINARY Unofficial and Subject to Change C 60% PLANS 9 2 2 9 2 1 PLAN COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR G T S VI SAL TE C63209 * 06/30/12 CIVIL A T E OF ENHANCEMENT PROJECT ER EXP. MK E IN CHARLES C. CHEN * DATE PACOIMA SPREADING GROUNDS N R EGIS TE R E D E SCALE: 1"-100’ I A 4 N 104 C o n t r 91 o l 8.4 NO. DRAFTER Unclassified excavation 1 8 " 5 3 9 916 910 1 5 " 1 8 " S T R E E T E RET CONC ER T T V-GU 929 5’ 18. CI TY OF L. A.PI PEPLI NE EASEM ENT 93 8 LI NE EAS EM ENT 916 BY 0 REVI EW ED F E N C E 8 " D E V O N S H I R E 3 9 920 Pacoi m aSGEnhancem ent . dgn ’ 1 2 1 4 " C H A I N L I N K L 65 F 930. 925 J.LI Pr o t e c t i n p l a c e Ex s t P. P. 1 6 " L 03 F 8. 91 Exist CLF 6 " 923 CHECKER 1 2 " C O W N C / M P E A T D A L L I D 925 924 S5 EL 911.05 8 " S T 1 5 A " N D P I P E 0 2 9 925 915 1 0 D 0 i 2 r t 9 S511 . 0 5 BASIN 5 WSE 916 I NT ERBASI NST RUCT URE3 4 9 9 . 1 9 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP2 P2o nSh . 5 2 4 " F E N C E 2 0 ’ 920 8 " C H A I N L I N K 5 2 9 5 ’ S T 2 2 " 1 3: 5 0 92 93 0 15 92 9 Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 3 9 ’ 0 2 9 ’ 20 CHARLES C.CHEN EL 915.83 Exst ground line 5’ DESI GNER 5 93 S2 V A L V E WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 2 4 " 3 L 21 F 5. 91 930 Exst access road 1 5 " 2 2 " 1 1 0 ’ V A L V E S t r u 2 B ct 1 1 ur D 1 e 1 0 1 C.1 O N6 2 2 " 5’ BASIN 3 WSE 936 Bot El 922 (Sh 10) 1 8 " 1 0 D 12 i r t 9 S 15.8 2 920 908 BASIN 6 WSE 908 Bot El 898 (Sh 7) 2 8 " 5 90 910 898 Pr o t e c t i n p l a c e Ex s t P. P. R T ad re i e us C a of n o p y 0 91 915 905 I NT ERBASI NST RUCT URE5 6 8 4 . 8 3 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP4 P4o nSh . 5 5 ’ CADD PROJECT FI LE NAM E S t r u c 2 C B- t 1 O u - N 10 r D C e 1 0 1 . 1 6 Basin 5 WSE 916 Bot 905 S t H r B uos Cib ce - tu 2 2 5 re 1 -P 24" CMD 5 gh4 8’Hi 2. 2 8 " 12 ’ 93 5 DATE ’ 5 Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 9 3 0 I NT ERBASI NST RUCT URE4 5 2 3 0 . 6 9 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP3 P3o nSh . 5 S t r u c 2 B t 1 u C 7 r O D e N 1 C 0 1 . 1 6 E 2 4 " 2 4 " 102 C o n t r 932 ol . 8 8 V A L V E 935 93 4 1 1 " 1 1 " 1 8 " ’ 5 HOR: 1"=200’ VERT: 1"=8’ Exst access road S t r 2 B uc 1 8 tu D 1 S re 0 1 . 1 4 1 5 " R T ad re i e us C a of n o p y SCALES: Pr o t e c t i n p l a c e Hi g hVo l t a g e T o we r 6 " 1 5 " y MH t i l i Ut m 34 Ri 935. 2 8 " WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 SECTION E-E 5 0 ’ 930 1 5 " 9 1 9 Ex s t P. P. ’ 0 2 9 3 4 Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 9 3 0 13 ’ 93 3 1 1 " ’ 5 2 Clay layer to be removed and replaced with unclassified fill 9 2 5 2 0 " 21 ’ 1 8 " 1 1 " 93 9 CITY OF L.A. MINOR EASEMENT 92 0 El. 914 910 WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 92 5 92 0 93 0 18 ’ 92 92 1 0 0 93 9 1 9 2 4 " 91 4 2 4 " F E N C E 93 2 Pr o t e c t i n p l a c e Hi g hVo l t a g e T o we r P P 3 6 " 93 1 2 4 " y MH t i l i Ut m 26 Ri 932. 93 7 93 0 0 2 9 9 3 2 1 3 .5 ’ 92 9 A C H R T ad re i e us C a of n o p y 1 8 " C H A I N L I N K 93 5 2 2 " 2 8 " 5 " V A L V E 93 92 0 5 D E V O N S H I R E 6 " H B OS I B E Basin 4 WSE 924 Bot 914 3 0 " H B OS I B E 42 " S t C r O u B NC 2 - ct 1 8 - ur D W 1 e 0 1 . 1 6 92 0 91 4 F E N C E 92 7 92 8 15 ’ C E IN L IN K F E N C H A I N LI N K 1 2 " 3 2 " 4 5 " SCE EAS EM ENT 935 92 6 y MH t i l i Ut m 34 Ri 935. 9 15 4 " 9 3 3 92 6 92 1 11 ’ 2 4 " excavation CONC 5 " 2 3 ’ S t r u B ct - GU 2 2 uA 1 8 rRe D D R A 5 I 4 L S 925 2 - Unclassified 3 6 " 4 6 " El. 922 Finish grade CONC D 2 8 " 9 2 0 2 4 " 1 3: H B OS I B E IN 2 0 ’ A S t r u c 2 B t 1 u 9 r D e 1 0 1 . 1 4 2 6 " 1 8 " C H 920 E H B OS I B E C 7 92 2 8 " 3 8 " 0 2 9 2 4 " Exist CLF 920 F E N 2 4 " 3 0 " K 9 " 4 " 3 6 " 3 0 " L IN O N C / M P E A T D A L L I D 3 " 2 4 " 9 2 5 0 3 9 0 5 2 2 9 9 4 1 9 9 2 8 C W BASIN 4 WSE 924 H B OS I B E 2 8 " 9 3 0 9 2 5 1 8 ’ 20’ 3 0 " y MH t i l i Ut m 55 Ri 929. 1 5 ’ (D Irr is iga c o tio n n n e c Lin te d e ) 9 3 0 5 2 0 9 2 9 4 1 9 Exst ground line Exst access road 6’ 9 3 1 2 6 " G U Y 1 5 " 930 1 5 " H B OS I B E F E N C E 922 925 929 4 2 9 2 0 " C H A I N L 1 I N 5 K " 930 E DENSE TREES G N V 4 0 " 3 0 " E NC FE LACFCD R/ W 937 I C V 5 3 9 NK I NL AI CH H B OS I B E 6 3 9 4 0 " 1 5 " 3 8 " 4 0 " 6" CMB R FO I L CA EXCAVATION AND GRADING PLAN - BASIN 4 & 5 DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.9 SHEET 9 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:35:33 AM HOSE BIB PP A G E T 947 15’ HOSE BIB 940 E C N E F K N LI N I A H C C H A 9 92 94 5 G A E T 92 9 94 0 5 93 5 Clay layer to be removed and replaced with unclassified fill Exst 8.5’W x 3’H RCB L F 109 946.09 Control 6 .3 8 3 9 3: 1 SECTION F-F L F 1 .3 8 SCALES: 3 21-D 9 L F 2 .2 8 3 9 HOR: 1"=200’ VERT: 1"=8’ L F 5 .1 8 3 9 S K C O R Modify exist outfall (Sh. 11) 1 0 0 . 0 = S 5 3 9 A CH 5 94 E S K C O R 945 0 92 9 94 0 93 5 9 4 5 CHAI NLI NK FENCE 9 92 0 94 1 00 0. 9 92 S = 0 94 5 93 9 92 0 94 9 92 ’ 12 0 94 5 93 5 93 0 94 0 94 1 0 0 . 0 = S GUY 9 92 WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 5 3 9 4 4 9 940 935 929 1 00 0. GUY 9 92 GUY Ve nt 5 93 1 8" Pi pe Abov e Gnd and Vaul t s 5 93 East Settling Basin WSE 941 Bot 929-931 5 93 VAL VE S= 0 STREET R/ W 943 942 944 4 9 NC FE TA LE AR NK I NL I 5 93 ’ 12 17 ’ 3 4 9 ’ 12 AVE L F 935 940 94 3 935 105 941.20 Control 929 WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 P M C m " 4 Ri 2 9 p o 2.1 T 4 9 Structure B-1 942 NCE NK FE NLI CH AI 5 3 9 S=0 . 0 0 1 F 5 3 9 93 0 930 9 3 5 FEN CE WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 940 5 9 93 92 940 935 0 94 23 ’ 3 .4 6 2 9 NK NLI CHA I BY ’ 2 1 21-D101.14 S T R E E T E R CHAINLINK FENCE I NT ERBASI NST RUCT URE Ea s t Se t t l i n gBa s i n1 7 7 . 8 4 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP5 P5o nSh . 5 p o 4.3 T 4 9 LV E R T U N D Structure P M B-1-E,C-1, C B-1 W m " 0 Ri 21-D54 3 0 CHAINLINK FENCE C U DE V ONS HI RE ST 940 CHAINLINK FENCE E L E C T OWE R CHAINLINK FENCE 9 4 1 9 4 3 9 4 2 935 935 930 0 4 9 930 P A R 8 3 9 94 0 925 918 Basin 1 WSE 932 Bot 918 (Sh. 8) 7 2 . 7 2 9 2 4 9 1 4 9 0 4 9 9 3 9 5 93 5 3 9 J.LI 94 0 P I R 93 8 9 4 3 940 21-D54.4 925 P M C m " 4 Ri 2 p 78 . o T 2 4 9 9 4 3 940 940 930 P M C gh " Hi 4 ’ 2 3 1. 942 HOSE BIB 21-D54.4 935 9 3 9 94 0 935 943 0 3 9 GUYS 4 8 . 2 2 9 Los Angeles County Department of Public Works The Information Shown Hereon is 8 3 9 PRELIMINARY L E Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 Unofficial and Subject to Change L E 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS D N G CHARLES C. CHEN CIVIL A * 06/30/12 T E OF I A T S VI SAL TE C63209 N EXP. ENHANCEMENT PROJECT ER * SCALE: 1"-100’ E IN PLAN PACOIMA SPREADING GROUNDS E R EGIS TE R E S S I E O NA OF L PR NO. DRAFTER 2. 5’ 0 94 5 93 9 3 5 0 94 9 92 9 92 0 94 5 93 5 93 9 92 E C 1 94 S K C O R 93 5 93 9 1 94 N E F E El. 922 920 4 9 0 5 0 92 93 2 92 K C E V A N E F excavation Exst Transition Structure to 8.5’W x 3’H RCB 4 9 4 6 . 4 3 1 9 S L E Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 CHARLES C.CHEN N LI K K N I L N I A H C 1 0 .0 0 0 94 9 92 5 3 9 6 93 5 93 S K C O R S K C O R IN IN L A IN = 5 3 9 5 93 0 94 9 92 8 93 S K C O R A Finish grade E C N E F GAT E 9 3 5 Hi g hVo l t a g e T o we r Unclassified Exst Double 54" RCP GAT E I NT ERBASI NST RUCT URE We s t Se t t l i n gBa s i n3 7 7 . 8 4 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP1 P1o nSh . 5 9 4 Hi g hVo l t a g e T o we r 1 3: 0 .2 7 4 9 L F 0 .8 6 4 9 H C H C 0 5 93 1 00 0. 8 93 CE Modify exist outfall (Sh. 11) ’ 12 ’ 0 2 9 4 0 9 3 0 9 9 3 2 5 2 9 2 5 Structure B-7 REVI EW ED N FE E T 9 92 930 L F GUY 9 4 0 Exist CLF L F S 4 9 = 9 4 0 9 3 5 935 930 925 920 914 DATE K A Exst ground line 6 .3 7 4 9 S=0 . 0 0 1 21-D101.16 Pacoi m aSGEnhancem ent . dgn N LI G Exst 8.5’W x 3’H RCB L F 6 .6 8 3 9 1010 934.64 Dirt S1 SCEEa s e me n t CADD PROJECT FI LE NAM E N I 1 0 .0 0 9 21-D52 5 93 I NT ERBASI NST RUCT URE3 4 9 9 1 9 ’ 7 2 " RCP, 2 0 0 0 D Se ePr o f i l eP2 P2o nSh . 5 CHECKER A = BASIN 3 WSE 936 GUY 0 WEI RST RUCT URE Se eDe t a i l o nSh . 1 7 Ou t l e t St r u c t u r e , Se eDe t a i l o nSh . 2 0 Basin 4 WSE 924 Bot 914 (Sh. 9) 940 Exst Transition Structure to 8.5’W x 3’H RCB 4 .3 8 3 L F 1 .6 8 3 9 5 3 9 S 0 5 94 93 0 925 93 2 92 9 3 5 L F 2 .4 8 3 9 West Settling Basin WSE 941 Bot 929-931 9 4 Exst access road CH S 1 00 . =0 5 93 7 93 HOSE BIB HOSE BIB PP 21-D101.16 HOSE BIB ’ 23 7 94 Exst access road L F 0 94 5 93 S CHAI NLI NK FENCE ’ 12 Structure B-6 Basin 3 WSE 936 Bot 922 Exst Double 54" RCP BFP ’ 12 Ex s t P. P. DESI GNER 5 941 94 P M C gh " Hi 0 ’ 3 .3 3 5 93 940 VAL VE 9 3 6 A T E L HOSE BIB 108 941.68 Control HOSE BIB R A E C 0 94 N E F 945 0 94 HOSE BIB 940 K HOSE BIB 935 HOSE BIB IN L E ENC F NK I NL I CHA HOSE BIB IN F LACFCD R/ W ’ 13 945 946 E ENC F NK I NL I CHA PP EXCAVATION AND GRADING PLAN - R FO I L CA Basin 3, East & West Settling Basins DATE MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.10 SHEET 10 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:37:54 AM HGL Intake manifold headwall (Sh. 13) Exst ground WSE 941 Bot El 931 960 950 950 East Settling Basin 7 8 0 0 . S=0 WSE 941 Bot El 931 940 Outfall structure See Sh. 22 930 930 112’ 940 930 26’ TS 26’ TS 38.3’ 0 9 0 0 . S=0 96 . 43 .9 l E 930 940 Intake manifold headwall (Sh. 13) 950 ar l l 8 co 0 c. d.3 on t C rS pe ar l l 8 co 0 c. d.3 on t C rS pe Outfall structure See Sh. 22 40 . 44 .9 l E 940 960 7 0. 94 st x l E ne i Jo West Settling Basin 960 8 0. 94 st x l E ne i Jo 950 HGL Unclassified fill El .9 43 . 91 Unclassified fill 90’ ARLETA AVE 14.9’ 115.75’ Finished grade El .9 44 . 36 960 26.5’ ARLETA AVE Q = 300 cfs M H 320 M H 320 Q = 300 cfs 262’ 736’ 38.3’ 215’ Double 54"RCP, 2000D Rubber Gasket Joint Existing Double 54" RCP 270’ 259’ Double 54"RCP, 2000D Rubber Gasket Joint Existing Double 54" RCP Exist 8.5’W x 3’H RCB 360’ Double 54"RCP, 2000D Rubber Gasket Joint Exist 8.5’W x 3’H RCB PROFILE P8-P8 PROFILE P9-P9 WESTERNLY CONDUIT PROFILE EASTERNLY CONDUIT PROFILE SCALES: HOR: 1"=100’ SCALES: VERT: 1"=10’ HOR: 1"=100’ VERT: 1"=10’ Finished grade GA Bedding B TE Typ. Typ. 12" 950 FEN CE 940 Transition to exst 8.5’W x 3’H RCB E S O H B I B S= 0. 001 I NL I NK 950 Exst Double 8.5’W x 3’H RCB 960 940 Bedding A 94 5 Exst Double 54" RCP Double 54" RCP Double 54" RCP Section A-A Double 54" RCP See P8-P8 RO CK S RO CK S 9 3 5 SCALES: 1"-80’-0" E S O H B I B 940 RO CK S DATE CH A E S O H B I B 941 9 4 7 Outlet structure See Sh. 22 12" Typ. 945 940 93 929 5 WEST SETTLING BASIN WSE 941 Bot El 929-931 (Sh 9 ) 12" E S O H B I B 960 FP FE NC E ACCESS RAMP C RO CK S GA TE e nc l Fe al W nk of i nl ai op Ch t on 2 5 D B 1 2 CH AI NL I NK HA I N 95 0 LI NK 30" CMP 3. 3’H i gh Finished grade SEE PLAN (Sh. 12) Unclassified fill Bedding B FE NC E 956 . 85 GB 950 V P P H A A N LI K N FE E C G U Y R BLE BUB APC PLC . COMP 956 . 28 GB BY 1 2 Diversion Gate Rubber dam (Sh 11) 2: 1 RO CK S Exst Double 8.5’W x 3’H RCB K FE N Control House (Sh 23-27) 955 945 C E A R NK I NL AI CH E NC FE Typ. 12" e nc Fe LE TA nk i nl ai Ch C H LI N 94 5 12" Typ. DI Typ. 12" DI Bedding B 12" 5 95 Exst Transition Structure to exst double 8.5’W x 3’H RCB Unclassified fill Bedding B 12" Typ. 0. 00 1 = 0 95 DI S 5 94 Install flow meter 12" RO CK S 0 94 e nc Fe 0 94 LT 5 94 967 . 28 TP 961 . 86 TP nk i nl ai Ch U rt Ve e p Pi 0 95 e nc l Fe al W nk f i nl o ai L Ch C/ on E NC FE DI NK I NL AI CH ON SI R VE I AD M I CO PA EL NN A CH e nc l Fe al W nk f i nl o ai p Ch to on A V D FEN CE ST I N 935 Bedding A 955 9 4 4 Bedding A Double 54" RCP Section C-C Double 54" RCP SCALES: 1"-80’-0" 94 5 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR N G VI SAL TE T S PLAN SCALE: 1"-100’ C63209 CIVIL A * 06/30/12 T E OF I A EXP. ENHANCEMENT PROJECT ER * Unofficial and Subject to Change E IN CHARLES C. CHEN NO. PRELIMINARY PACOIMA SPREADING GROUNDS E D N e nc Fe Los Angeles County Department of Public Works R EGIS TE R E 9 4 3 nk i nl ai Ch J.LI Typ. N I P P V G CE FEN SCALES: 1"-80’-0" C 960 . 34 TP n o i e s r r u e t v c i u D r t S TE NK I NL AI CH W P A 956 . 43 GB P P l ai dr ar Gu P G 956 . 44 GB Section B-B TE GA 956 . 08 GB Exst Access Ramp PI LE e nc l Fe al W nk of i nl ai /L Ch C on e nc l Fe al W nk of i nl ai op Ch t on TE G AT E 956 . 41 GB 956 . 50 GB V P Y A 9 0 956 . 73 GB 956 . 47 GB Fill contact line 956 . 40 GB Exst intake structure (Sh 11) The Information Shown Hereon is DRAFTER Double 54" RCP W P U G G t n . 9 46 10 9 l ro Co Ex s t P. P. BFP al ) et 3 M s ( d Li P E S O H B I B P P E s ve l Va E S O H B I B P FE NC Double 54" RCP See P9-P9 Exst Double 54" RCP 12" P P s r e e os H s b Bi P P Y P U P G LI NK B 955 A CHECKER Y Bedding A Double 54" RCP DI RT PA XT ON 93 9 5 40 CHARLES C.CHEN 940 955 C CH AI NL I NK Outfall structure See Sh. 22 92 9 DESI GNER Y 940 U G Intake manifold headwall (Sh 13) e n i g n E n o i s l r e e n v n i a h C 9 5 7 9 5 6 U G P P f o s p 6 r 4 o / C 0 4 6 4 / 1 4 4 1 D EXST DIVERSION CHANNEL 950 12" 9 5 9 955 956 . 1 6 G B 955 . 48 GB 945 950 AI N AVE 954 . 71 GB 950 TE 954 . 1 4 G B Typ. A G 953 . 38 GB 8 5 9 957 95 8 NCE E K F CHL 945 CH Pacoi m aSGEnhancem ent . dgn A . .I 952 . 32 GB CHAI NL I NK F E NCE W e os H b Bi 955 954 953 952 E 951 FEN C Top 30" CMP 955 . 72 Ri m 951 . 50 GB 956 2 LI NK n o i s r s e 4 k v 1 r i 7 . o D . 9 W 1 2 1 . 8 1 9 . . D 1 1 2 1 . D 9 9 D Ex s t P. P. AI N 94 0 94 5 D K 9 R 0 M 1 L W F # & 9 T K " 1 P P 2 3 S S 8 0 A . 8 M M 1 1 S O 6 . S 2 9 D 9 P 7 9 F 0 1 0 . " 9 7 6 1 2 4 4 9 6 l E E 93 5 12" CHAI NL I NK F E NCE B E S O H B I B REVI EW ED e os H b Bi s ve l Va 951 . 01 GB CH EAST SETTLING BASIN WSE 941 Bot El 929-931 (Sh 9) 960 CHAI NL I NK F E NCE Top 24" 955 CMP . 3 R i m N CADD PROJECT FI LE NAM E 960 C EXCAVATION AND GRADING PLAN - R FO I L CA Diversion Channel Intake DATE 60% PLANS MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.11 SHEET 11 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS.dgn 05/24/2012 4:22:35 PM 175’ 7. 5’ 7. 5’ 15 ’ 1+0 0 Construct 175’ - 5’ CLF Section 1 Section 2 Section 3 Section 4 See Sh x See Sh x See Sh x See Sh x 38’-1" 37’-2" 49’-9" 49’-10" 8 7 3 2 0 S=. Exst ground line Top of wall Const. Jt (Typ.) BC =S t a.1 +32 . 13 20’ VC = . 10 56 3 I nver tEl . 960. 45 St a.1+05. 00 EVC I nver tEl . 961. 22 EC = Sta. 2+73.43 St a.0+95. 00 PVI BC = Sta. 1+32.13 I nver tEl . 961. 41 PI = N 1918539.5465 E 6427693.9355 Begi n Access Ram p = 7035’26" 1 R = 114.69’ L = 141.30’ S St a.0+85. 00 BVC C L Construction Curve Data 00 + 2 Joi ntExstgr ound sur f ace 6" PCC on 4" CMB St a.0+85. 00 St a.1+00. 00 End 6"PCC PVM T Begi n Ret ai ni ng W al l& CLF St a.0+85. 00 Begi n 6"PCC PVM T 15’ S=. 0 1 0 0 0 A R 1 20’ VC Full length of access ramp invert shall be heavy brown finish. Sawcut I nver tEl . 946. 10 St a.1+05. 00 EVC I nver tEl . 946. 44 St a.2+54. 93 PVI I nver tEl . 961. 41 St a.2+44. 93 BVC St a.164+59. 11 SawcutChannelwal l 946 ChannelSt a.164+44. 11 A V ExstExpansi on Jt . End retaining wall & CLF 945 2. Reinforcement not shown, see Structural Schedule. P EC = Sta. 2+73.43 DATE 1. H PP S Notes: BY Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E REVI EW ED 3 0 Los Angeles County Department of Public Works COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE DRAFTER T S CIVIL A T E OF MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. DATE PACOIMA SPREADING GROUNDS E IN R EGIS TE R E J.LI 60% PLANS G CHECKER Unofficial and Subject to Change N CHARLES C.CHEN PRELIMINARY E DESI GNER The Information Shown Hereon is R FO I L CA PROPOSE ACCESS RAMP PLAN AND PROFILE DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.12 SHEET 12 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:32:04 PM Centerline 4 - 54" RCP Fill contact line 95 8 95 7 Fill contact line 4’ WV 12" head wall See Std. Plan 3’ MH 323 See Sh. 16 11’ 2" 12" thick top slab 12" pier PP 14’ 18’-0" Transition Exist headwork structure & shelter house Exst house 7’ Exst wall construction Jt type B Exist diversion channel wall ST ORAG WV GP PP GP GP GP 10’-0" Sawcut and join exist concrete slab & channel wall Exst wall expansion Jt. type D Obermeyer or approved equal 8’ high rubber dam See Sh. 14 DATE Exst invert expansion Jt type A C L 55’ 0" 944 REVI EW ED 943 942 57’ 0" Flow Exst invert expansion Jt type D 944 DI VERSI ON CHANNEL Exst trapezoidal channel wall St a.162+21. 09 Exst channel toe H S LWA NNE MACHA COI A P Exst PED. Bridge BY Exst invert expansion Jt type D Pacoi m aSGEnhancem ent . dgn 4’ Exstwal l expansi on Jt .t ype D St a.162+50. 35 12’ 6’ 4’ Exstwal l expansi on Jt .t ype D St a.161+56. 52 Exstwal l const r uct i on Jt , t ype B St a.161+06. 52 The Information Shown Hereon is PRELIMINARY Unofficial and Subject to Change VI SAL TE CIVIL A T E OF DESCRIPTION REVISIONS PROJECT ENGINEER ENHANCEMENT PROJECT * 06/30/12 I A EXP. N R EGIS TE R E * C63209 R FO I L CA DATE FCC0001207 RUBBER DAM AND INTAKE PLAN VIEW P I P E NO. C O R R I D O R MK PACOIMA SPREADING GROUNDS O DO 0’ 3. FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:41:37 AM DATE CHARLES C. CHEN ER $FILEL$ SCALE: 1=100 D E IN $TIME$ PLAN T S FILE. COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR CL J.LI Los Angeles County Department of Public Works Control House (See Sh. 19-23) G CHECKER PLC 2" Schedule 10 stainless steel air supply/exhaust pipe N CHARLES C.CHEN APC 2" Schedule 10 stainless steel condensate purge line E DESI GNER 5’-4" COMP. Exst flood gate buttress fo ss tre But DRAFTER 10’-0" 60% PLANS Fen nk i nl i W of Cha C/L on TIME. $DATE$ See Sh. 28 12.5’ LACFCD RW DATE. Install flow meter Exst flood gate buttress BUBBLER CADD PROJECT FI LE NAM E Exst invert expansion Jt type D JOB EF11610123 DWG 21-D114.13 SHEET 13 OF 29 PS-DF 07/05 Sta. 161+28.52 Sta. 161+56.52 55’-0" Exst 1/2" type D expansion joint at the invert slab, install joint per detail "S1", hereon Exst 1/2" type D expansion joint at the retaining wall; install 1/2" pre-molded expansion filler on the wall joint per detail "R1" , hereon Fl ow Exst 1/2" type D expansion joint at the retaining wall; install 1/2" pre-molded expansion filler on the wall joint per detail "R1" , hereon D End construction proposed concrete channel wall section per plan Begin construction proposed concrete channel wall section per plan C 943 l l wa l e n n a h c t s i x e f po o T B Sta. 161+56.52 Begin wall and invert slab removal Exist expansion Jt. Abutment plate Protect exst retaining wall and footing A A Protect exst retaining wall and footing Sawcut line Gate raised E E v In F 9 .1 3 4 l9 E Air bladder inflated 8’ 0" 18’ 0" WSE 851.19 Restraining strap F Air supply connection block out 9’-6" 6’-6" G 28’-0" Remove exst concrete retaining walls and invert slab and construct proposed concrete channel wall per section details on plan SECTION B-B Sta. 161+28.52 DATE 2. All fill shall be inspected and tested during placement. Exst. L-wall footing Remove and Reconstruct 12" 12" 4"CLR Retain exst. footing reinforced bars 2’ 6" 18" #5@12" 6" #5@6" 20"t o 12" Var . 161+28.52 Sawcut line #6@6" #6@12" #6@6" 20"t o 12" Exst. L-wall footing #6@6" 18" Var . 18" 6" 6" 6" SECTION A-A 24" 2’ 6" 20"t o 12" Var . Exst. L-wall footing 4"CLR #5@6" 6" 3"CLR For Reinforcement See Typical Channel Section, hereon Exst. 1/2" type D expansion joint. Install joint per detail "S1", hereon. 14’ 6" 8’ 6" 20" Remove exst concrete slab see removal notes hereon OHI air bladders 12" BY #6@12" NOT TO SCALE 6’-6" Install 1/2" Premolded Expansion Jt Filler 1/ 2T Paint and oil end of dowel NOT TO SCALE Los Angeles County Department of Public Works Install 1/2" Premolded Expansion Jt Filler The Information Shown Hereon is PRELIMINARY Unofficial and Subject to Change 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS 2" 1" * EXP. C63209 CIVIL A T E MK ENHANCEMENT PROJECT * 06/30/12 OF DATE PACOIMA SPREADING GROUNDS ER TRANSVERSE WALL JOINT TYPE "D" EXPANSION JOINT DETAIL " R1" NOT TO SCALE CHARLES C. CHEN NO. T S TRANSVERS INVERT JOINT TYPE "E" EXPANSION JOINT DETAIL " S1" D E IN #9@12" O.C. No reinforcement through joint G Exst Channel Wall I A 3" S S I E O NA OF L PR N 3. Retain existing reinforcement bars unless otherwise indicated . N CHARLES C.CHEN 2. Cut a groove in the concrete adjacent to the sawcut on the side to be removed to the depth of the sawcut with a chipping hammer. remove the remaining concrete in a careful manner with a hand-operated equipment leaving a clean plane surface for bonding new concrete. the horizontal reinforcing steel at intersection of the existing and new construction shall be lapped into the new construction. this extension shall be per ACI 318-08. 4. The remaining concrete may be removed by any suitable method upon approval of the engineer, who shall be the sole judge of the use of any concrete removal equipment. explosives, wrecking ball, or other similar devices, which are likely to damage the concrete to be left on place, shall not be used. 12" SECTION D-D T J.LI 1. A saw cut shall be made one and one-half inches deep at the removal limits. care shall be exercised in the sawing at the removal limits so as not to cut the reinforcing steel in the remaining slab. the existing reinforcing steel shall be retained and extended into the new construction as indicated in the plans. 12" 1/4" Chamfer on Channel face R EGIS TE R E REVI EW ED Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E SECTION C-C Sta. 161+56.52 Exst expansion joint Obermeyer or approved equal steel gates 18" VI SAL TE CHECKER 6’-6" E DESI GNER #6@12" NOT TO SCALE Concrete Removal Notes: DRAFTER Exst. L-wall footing #6@6" 18" #6@6" #6@6" Exist ground line 55’-0" Restraining Straps Remove exst. channel wall (typ.) #5@6" #6@12" Pacoima Wash Channel Remove exst 5’ high chain link fence and replace in kind. 6" 161+28.52 Sawcut line 18" 1. Footing excavation, fill subgrade shall be inspected by agency (ladpw) geotechnical personnel before placement of concrete or fill. 6" 2’ 6" Var . Construction Notes: #5@6" #5@12" 3"CLR SCALE:1"=5’-0"’ Retain exst. footing reinforced bars 18" 20"t o 12" RUBBER DAM (SH. 13) FOUNDATION PLAN 4"CLR Exst. 1/2" type D expansion joint. Install joint per detail "S1", hereon. 6" 57’-0" Sta. 161+56.52 Exst expansion joint 6" End removal of concrete wall and invert slab B 24" C NOT TO SCALE 4"CLR D 10’-0" 24" 6" Sawcut line; paint surface with a thick coat of asphaltic paint at the wall joint. Sawcut per concrete removal note 1 hereon. Retain exst long. bars and extend 18" into new invert slab. Sawcut line; paint surface with a thick coat of asphaltic paint at the wall joint. G Dr ai 94 n 8. Ou 68 tl et I nv Tr ansi t i on 10’ 0" See Sh. x R FO I L CA RUBBER DAM AND CHANNEL WALL DETAILS DESCRIPTION NOT TO SCALE REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.14 SHEET 14 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:42:06 AM Exist ground line 55’-0" 12" 12" Exist ground line Exist ground line Var. (55’-0" to 57’-0") 12" Remove exst 5’ high chain link fence and replace in kind. Remove exst 5’ high chain link fence and replace in kind. Exist ground line 12" Remove exst 5’ high chain link fence and replace in kind. Remove exst 5’ high chain link fence and replace in kind. 3" CLR 3" CLR 3" CLR 3" CLR 3" CLR 3" CLR 3" CLR 3" CLR (typ.) (typ.) (typ.) (typ.) (typ.) (typ.) (typ.) (typ.) #5@6" #4@12" 18" 5’-0" 5’-0" 15’-0"(MIN.) 2’-6" 2’-6" 14’ 0" 18" invert slab Roughen starter wall joint 6’ 6" Exst. channel 3" 3" 18" 24" 18" 5’-0" 5’-0" (MIN.)15’-0" 15’-0" (MIN.) No Splice No Splice No Splice #6@12" ( t yp. ) 6’ 6" Roughen starter wall joint 18" 18" 18" 18" 24" #5@6" 14’ 0" 14’ 6" #4@12" U-bar #6@6" #4@12" 3" invert slab 6’ 6" Roughen starter wall joint Exst. channel #6@12" ( t yp. ) 4"CLR 3" 6’ 6" Roughen starter wall joint #6@6" #4@12" 14’ 6" #4@12" #5@6" 4"CLR #6@6" ( t yp. ) #6@6" 4"CLR #5@6" 2’-6" 2’-6" 18" 24" 15’-0"(MIN.) No Splice SECTION E-E, (SH. 14) NOT TO SCALE SECTION G-G, (SH. 14) NOT TO SCALE Exist ground line 55’-0" 12" 12" Remove exst 5’ high chain link fence and replace in kind. Remove exst 5’ high chain link fence and replace in kind. 3" CLR 3" CLR 3" CLR 3" CLR (typ.) (typ.) (typ.) (typ.) #5@6" #6@6" #6@6" #5@6" 14’ 6" #4@12" 14’ 6" DATE #4@12" 4’-9" (typ.) (typ.) Exst. channel invert slab #4@12" U-bar 24" 18" 18" 18" 18" 4" 3" #6@12" ( t yp. ) 4"CLR 3" 10" #4@12" U-bar Roughen starter wall joint 6’ 6" 4’-9" 10" 6’ 6" Roughen starter wall joint BY REVI EW ED Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E Exist ground line 5’-0" 5’-0" 15’-0"(MIN.) 2’-6" 2’-6" No Splice 18" (MIN.)15’-0" No Splice SECTION F-F, (SH. 14) NOT TO SCALE J.LI The Information Shown Hereon is PRELIMINARY CHARLES C.CHEN Unofficial and Subject to Change 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS D G VI SAL TE CIVIL A * 06/30/12 T E OF I A T S DRAFTER C63209 N EXP. ENHANCEMENT PROJECT ER * MK E IN CHARLES C. CHEN NO. DATE PACOIMA SPREADING GROUNDS N R EGIS TE R E S S I E O NA OF L PR E DESI GNER CHECKER Los Angeles County Department of Public Works R FO I L CA RUBBER DAM AND CHANNEL WALL DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.15 SHEET 15 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:42:26 AM 7’-0" C 11’ 6" 15’ 3" 15’ 0"t o 11’ 10" B 12" 2" 2" Remove existing intake wall & invert slab 12" 12" Typ. 18" #5@12" 18" 15’ 0"t o 11’ 10" 18" 12" 11’ 10" 12" 2" 7" B 6" C #5@12" 12" 12" D 2" " 12 l al adw He Sawcut & remove existing intake wall & invert slab #5@12" #5@12" Dowel #4 bars 6" into exst concrete and bend 18" into top slab 38’-8" 15’ 3" 3" 11’ 6" A Headwall SECTION C-C TYPICAL HEADWALL SECTION SECTION B-B SCALE: 1/2" - 1’-0" SECTION E-E SCALE: 1/2" - 1’-0" SCALE: 1/2" - 1’-0" 12" 21’-0" He adw al l 12 " 7" 12" 12" 14’-0" Dowel #5 bars 6" into exst concrete #4@12" 12" 12" 7’-0" 15" 4’ 6" 6" 12" 23’ 0" A 3’ 7" 15" D Sta. 162+21.09 15" C L DIVERSION CHANNEL 4" 30’ 6" #5@12" 12" Bend 18" into top slab 11’-2" #5@12" 18" Typ. #5@12" Headwall corner, see Detail "G" 12’-0" 18" 2 L " R TYPICAL HEADWALL CORNER REINF. 2" 2" SCALE: 1/2" - 1’-0" MH 323 E 3’ SECTION D-D SCALE: 1/2" - 1’-0" 4’ Remove existing intake wall & invert slab SCALE: 1/2" - 1’-0" Retain & lap exst rebar 18" 4" #5@12" 2" #5@12" 12" 16" Retain & lap exst rebar 18" Unclassified fill #5@12" SECTION F-F 12" 7’-0" 3" El 959 15" 15" El 961 Channel face 12" #5@12" Bend bar 18" into headwall 7" 4" F P 54 "R C Joi n exi st i ng wal l& i nver t sl ab perdet ai l" H" Sawcutl i ne 12" BY Exst control house Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E REVI EW ED DETAIL "G" 54 "R C P C 11’ 10" DATE #4 diagonal bar on both faces Bend 18" into sidewall 18" SCALE: 1"-4’-0" 11’ 10" PLAN VIEW INTAKE STRUCTURE 6 ty " p . 6 ty " p . #5@12" on both faces El 851.83 15" 3" 5’ 0" R EGIS TE R E NO. * Slab footing EXP. VI SAL TE T S DRAFTER C63209 DATE MK PACOIMA SPREADING GROUNDS CIVIL A T E ENHANCEMENT PROJECT * 06/30/12 OF SECTION A-A SCALE: 1"-4’-0" CHARLES C. CHEN ER 12’-6" D E IN 14" COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR G 11’-2" F 60% PLANS N 21’-0" Unofficial and Subject to Change SCALE: 1/2" - 1’-0" 6" E PRELIMINARY DETAIL "H" CONSTRUCTION JOIN DETAILS El 946 El 944 SCALE: 1/2" - 1’-0" I A 6’ 0" 12" 14" SCALE: 1/2" - 1’-0" E CHARLES C.CHEN El 947.2 The Information Shown Hereon is INVERT JOINT N 8’ 0" J.LI WALL JOINT 15" DESI GNER CHECKER 2" Los Angeles County Department of Public Works R FO I L CA INTAKE STRUCTURE DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.16 SHEET 16 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:42:45 AM "S" Expanded metal cage see Sh 36 Expanded metal cage see Sh xx See Table Hereon See Std. 640 for WS 4-5 EMO, see Mech Dwgs (Sh. xx) 4" Top of slope, for elevations see Table hereon 4" 3 : 1 TW 3’ -6" 6’ -10" 4’ -4" 12’-0" W T" " El W l" rE i e WEIR STRUCTURES Weir Structure Location WSE East S.B -1 East S.B 941 10’-6" 943 939.5 929 WS 1 932 12’-6" 934 930.5 WS 2-6 WS 2 917 8’-6" 919 West S.B -3 West S.B. 941 10’-6" WS 3-4 WS 3 936 WS 4 WS 1-2 " WS 4-5 WS 5-6 WS 6-Outlet Steel Steps per Std Plan 635 Weir Ht "Hw" TW El "T" Weir El "W" Inv El "I" Top of slope "S" "X" RCP- Length 943 0’ 24" RCP - 7’-6" 918 934 0’ 36" RCP - 12’-0" 915.5 907 919 0’ 24" RCP - 4’-0" 943 939.5 929 944 3’ 24" RCP - 9’-0" 12’-6" 938 934.5 922 938 0’ 24" RCP - 15’-0" 924 8’-6" 926 922.5 914 934.5 Std. 640 36" RCP - 4’-0" WS 5 916 9’-6" 918 914.5 905 918 0’ 36" RCP - 4’-0" WS 6 908 8’-6" 910 906.5 898 910 0’ 36" RCP - 4’-0" T W E l" T " 8’-8" 3’ -6" 5’H Clf per Std Plan 600 30’-0" 6’-0" W W l" rE i e " Top of weir c.p. 2’-6" Metal Hand Railings per Std Plan 606 3 : 1 3’-0" 9’-0" % 3 S= 4"R I nv E l" I " Note: 24" 72"RCP or 60" RCP at discharge o X p e " n in g " I " El v n I 13" JS 6’ -0" Low flow Inlet Structure "I", see Sh 21 1’ -6" 25’-4" 16" ) n Mi ( " 6 "Hw" Retaining Wall per Std Plan 610 c.p. 6’-0 "Hw" 6’-2" 16" ~ For structural reinforcement schedule, see Sh.20 5’-0" Backfill with 450-C-2000 concrete 42"x42" Slide gate not shown "X" RCP- Length Box-out per gate manufacturer. Grout filled after gate installation. Note: For structural reinforcement schedule, see Sh.20 See table hereon SECTION A-A SECTION B-B SCALE:3/16"=1’-0" FRONT WALL B SCALE:3/16"=1’-0" C 3:1 5’-8" 8’-0" 12’-0" Note: For structural reinforcement schedule, see Sh.18 DATE Retaining wall Expanded Metal Cage. See Sh 36 Toe ofsl ope "S" Chain Link Fence and Gate per Std Plan 600 4’-0" 2’-0"2’-0" 8’-0" 8’-0" 6’-9" 5’ Clf 5’ CLF 30’ -0" 6’-0" Steel Steps O 24" 6’ -9" A BACK WALL PRELIMINARY SCALE:3/16"=1’-0" Unofficial and Subject to Change Retaining wall 5’ -0" 3:1 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS D CHARLES C. CHEN VI SAL TE T S SCALE:3/16"=1’-0" CIVIL A T E OF DATE MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. WEIR STRUCTURE (SH. 4) PACOIMA SPREADING GROUNDS E IN C G B R EGIS TE R E S S I E O NA OF L PR PLAN DRAFTER The Information Shown Hereon is SECTION C-C 6’ -9" "X"-RCP Metal Hand Railing Los Angeles County Department of Public Works N J.LI Flow E CHECKER 6’ -0" Gate A CHARLES C.CHEN % 3 S= 3’ -5" 2’-6" 2’-6" 12’-0" 7 2 p "o e n r6 in 0 g " 2’ -6" JS 4’-9" "Hw" 3:1 4’ Walk gate " 6’ -0" 3:1 W W l" rE i e Steel Step per Std Plan 635 72"RCP or 60" RCP at discharge DESI GNER 6’-0" 5’ -0" Pacoi m aSGEnhancem ent . dgn Top ofsl ope BY 3:1 3’ -6" 3’ -6" AC Pavement 16" CADD PROJECT FI LE NAM E REVI EW ED TW T" " El R FO I L CA WEIR STRUCTURE DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.17 SHEET 17 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:36:20 PM 16" 6’ 16" 30’-0" 16" E Detail "B" Detail "B" See Sh. 21 Galvanized Detail "B" steel gratings Hereon 12’ 16" 16" F Galvanized See Sh. 21 per std. plan 635 12’-0" EMO pedestal #5@12" wall bracket #5@12" Constr Jt #5@12" 2" Stem 2’-6" 2" Var i es #5@12" #5@12" #5@12" guide 2" 11/ 2" #5@12" 2" 3’ -6" Steel step C6x8.2 2" 11/ 2" 2" 3’ -6" 3’ -6" 11/ 2" 11/ 2" See Sh. 21 C6x8.2 #5@12" #5@12" #3@9" Constr Jt 6" Min. Wall thimble See Sh. 41 3’-0" 6" Min. Constr Jt #5@12" 3" 3" #5@6" #5@12" #5@12" 18" 3" #5@12" #5@12" 7" 2" 18" 18" Typ. Typ. 18" #5@10" NOTE: Clf and expanded metal cage is not shown for clarity SECTION C-C NOT TO SCALE Bend bars 18" #5@12" into beam on both faces 11/ 2" 2" @12" "X" RCP PerTabl e Sh.17 18" #5@9" 18" 2" 4-#6 72" or60" RCP 24" 1 #5@10" 16" #5@6" 16" 6’ -0" 4’ -0" 2" #5@9" 2 2" 24" Lap 24" #5@12" #5@12" 2" #5@12" % =3 S 6" Constr Jt 4-#6@9" 24" Lap 2" Constr Jt 4’ -0" 4’ -0" #5@12" #5@12" 3" 2" 2’ -6" #5@12" 2" #5@12" 14" #5@12" 3’ -0" See t abl e on Sh.17 16" steel gratings See Sh. 21 D 4-#6 Conc. Backfill 18" #5@10" E D 5’-0" #5@12" #5@10" on both faces NOTE: Clf and expanded metal cage is not shown for clarity #5@9" a. Di a. i " 72 "D 60 or SECTION A-A 30" Horizontal Bar 18" NOT TO SCALE F SECTION B-B #5@6" 24" Lap Bend bars 18" NOT TO SCALE Bend bars 18" #5@12" 11/ 2" NOTE: Clf and expanded metal cage is not shown for clarity #5@12" Grout fill 24" #5@12" 1 4’-0" 18" 2 2" 5’L X 7’W 2 1/ 2" 450-C-2000 11/ 2" "HW " 12’-0" into beam #5@6" 4-#6 into side wall 4-#6 #5@12" on both faces 18" X" #5@12" 24" 18" B 30" 4-#6 bars SECTION D-D #5@12" PLAN SH. 16 on both faces DETAIL "A" #5@6" 16" Pacoi m aSGEnhancem ent . dgn on both faces Bend bars 18" Std Plan 600 24" Lap Hereon Constr Jt 12’ -0" Galvanized steel gratings A into side wall Detail "A" See Sh. 21 18" 5’H Clf per 2’-6" Add #5@12" A on both faces Bend bars 3’-0" into slab 3’-6" Wall thimble into wall #5@12" #3@9" stirrups See Sh. xx Bend bars 18" Constr Jt SECTION F-F Constr Jt Los Angeles County Department of Public Works NOT TO SCALE #5@6" 16" 30’-0" #5@12" 4-#6 PLAN Bend bars 24" SCALE: 1" =2’-0" Bend bars 4’-0" on both faces into slab Unofficial and Subject to Change 3’-6" 60% PLANS NOT TO SCALE into walls WEIR STRUCTURE B SECTION E-E Add #5@6" vertical bars COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS 2" #3@9" stirrups S S I E O NA OF L PR D CHARLES C. CHEN EXP. VI SAL TE T S TYPICAL BEAM REBAR C63209 * 06/30/12 CIVIL A T E OF ENHANCEMENT PROJECT ER * DETAIL "B" PACOIMA SPREADING GROUNDS E IN R EGIS TE R E 12’-0 span I A C N 16" 2" 36" RCP 16" J.LI bracket G CHECKER EMO wall N CHARLES C.CHEN PRELIMINARY 16" E DESI GNER The Information Shown Hereon is NO. DRAFTER into slab Bend bars 18" 18" 3’-6" into wall 2" CADD PROJECT FI LE NAM E 4-#6 bars Bend bars 18" 3’ -6" both faces Constr Jt both faces #3@ 9" st i r r ups #5 diagnoal bars C 4’ -0" Gate on both faces #5 on 2" TYPICAL CORNER REBAR NOT TO SCALE ty p . Expanded metal cage See Sh. 36 6" BY #5@12" 72 or "D i 60 a. " D i a. REVI EW ED Scale: 1"-3’-0" 72" RCP or 60" RCP #3@9" stirrups on both faces Pe "X rt " ab Di a. l e Sh .1 7 DATE #5@10" R FO I L CA NOT TO SCALE DATE MK WEIR STRUCTURE DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 11-D SHEET 18 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:36:47 PM 16" 6’-0" 16" Galvanized steel grating 1 3/4" x 3/16" @ 1 3/16" O.C. Galvanized steel grating with cross bar 4" O.C. EMO wall 1" with cross bar 4" O.C. 1" 1" 1 3/4" x 3/16" @ 1 3/16" O.C. bracket, See Sh. 41 L3 1/2" X 3 1/2" X 1/4" X 4" 2" 2" A 2" L3 1/2" X 3 1/2" X 1/4" X 4" 1/2" bolts anchor bolt 14" 1 4" 1" 3 1/2" X 5" 1" 16" 2" Gate 1/2" bolts 1/2" bolts 1 4" L3 1/2" X 3 1/2" X 1/4" X 4" C6X8.2 Conc. Wall Expanded Metal Cage See Sh. 36 3 14" 10’-1" 23" Conc. Wall 3 1" 2" 1/2" bolts 14" C6X8.2 EMO wall bracket NOTE: Expanded metal cage & EMO is not shown for clarity SECTION B-B TYPICAL CHANNEL TO CHANNEL CONN. NOT TO SCALE Galvanized steel grating SECTION A-A 1 3/4" x 3/16" @ 1 3/16" O.C. with cross bar 4" O.C. Galvanized steel grating 12’ -0" C6X8.2 10’ -1" NOT TO SCALE 1 3/4" x 3/16" @ 1 3/16" O.C. with cross bar 4" O.C. Detail "C" Hereon L2x2x1/4 C6X8.2 Anchor bar 1/2" bolts 1/2 x 0’-6" Typ. 1/4 23" C6X8.2 @ 24" o.c. 16" B B C6X8.2 Top EMO bracket DATE Conc. wall EMO wall bracket, see Sh. 41 A NOTE: EMO is not shown for clarity PLAN GALVANIZED STEEL GRATING SCALE: 1/2" =1’-0" DETAIL "B" (SH. 18) GRATING ANCHOR DETAIL GRATING ANCHOR DETAIL REVI EW ED NOT TO SCALE BY NOT TO SCALE Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E DETAIL "C" Los Angeles County Department of Public Works COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE DRAFTER T S CIVIL A T E OF MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. DATE PACOIMA SPREADING GROUNDS E IN R EGIS TE R E J.LI 60% PLANS G CHECKER Unofficial and Subject to Change N CHARLES C.CHEN PRELIMINARY E DESI GNER The Information Shown Hereon is R FO I L CA WEIR STRUCTURE DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.19 SHEET 19 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:37:16 PM 16’-0" 13’-0" Handrail per Std Plan 606 Handrail per Std Plan 606 21’-6" 14" #4@18" stirrups Symetrical @ C L #4 bars Finished grade slope 6"(Min) 6’ -0" 4’-0" 4’-0" 8’-9" 12" Embed 72 " 15’-0" 8’-9" 5’-0" R C P 5’-0" 9’ -6" 1 : 3 12" 12" Energy dissipator B" " El 12" Basin Bottom Bend bars 18" into slab 12" 24" 2’ -6" B" " l E See Detail "A" Here on 6" End Sill 2’ -6" Blocks 1 0 =. S 12" Conc. backfill 1 450-C-2000 18" 5’ -6" SECTION A-A #5 bars NOT TO SCALE 12" Detail "B" End Sill #4@18" both faces 3/4" chamfer all 4 sides 8" 2 " 8" #4@18" both faces DATE 15’-0" 12" B 24" 8-#4 Horiz. bars bend end 11’-0" SECTION B-B 3" 12" 112" #4@18" 18" 5’ -6" Riprap, 500 lb class 14" 4’ 1 NOT TO SCALE 14’-0" 12" varies from 7’-0" to 16’-0" 6’-0" W/2 5’ -0" #4@18" stirrups Energy dissipator blocks 12" DETAIL "A" 9’ -6" 14" 12" RC P 72 " 4’ -6" 2" 5’ -0" 5’ -0" 3’ -6" #4@18" 3" B6 #4@18" B7 6" 12" 8" DETAIL "B" 18" 2’ -0" 2’ -0" 12" 4’ -6" 3’ -6" 2’ -0" 2’ -0" 4’ -0" Const. joint #4@18" 8’ -9" 13’ -9" B2 Bar varies from 5’-6" to 10’-6" END SILL NOT TO SCALE B1 Bar varies from 7’-6" to 16’-6" 7’-0" C D 5’ -0" #4@18" stirrups SECTION D-D SECTION C-C TYPICAL REINFORCEMENT NOT TO SCALE SCALE:1/2"=1’-0" COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS CHARLES C. CHEN * EXP. SECTION LIMIT B1 B2 B3 B4 B6 B7 OUTLET STRUCTURE, TYPICAL 6’<H<9.5’ #5@12" #6@12" #5@14" #4@12" #4@12" #4@12" NOT TO SCALE 2.5’<H<6 #5@12" #5@14" PRELIMINARY T S VI SAL TE REINFORCEMENT SHEET SCHEDULE PLAN, (SH. 4) C63209 T E OF Unofficial and Subject to Change * 06/30/12 CIVIL A ENHANCEMENT PROJECT ER NO. B PACOIMA SPREADING GROUNDS E IN The Information Shown Hereon is D I A 14" N 21’-6" S S I E O NA OF L PR Los Angeles County Department of Public Works R EGIS TE R E J.LI 2" 6" Symetrical @ C L 16" B2 Bar G CHECKER 18" into invert slab (TYP) Optional Const. joint B4 Bar N CHARLES C.CHEN #4@12" Symetrical @ C L A bend ends 72"RCP " 3 2" #4@18" OUTLET STRUCTURES DRAFTER 4-#4 Horiz. bars bend end B1 Bar #4@18" both faces bend end 12" into side walls (TYP) #5@12" both faces 4" 8" B3 Bar E DESI GNER 2" 4 #5 diagonal bars both faces A.S. 8" 12" 2" NOT TO SCALE 4’ -0" 37’ -6" A 2’ -0" 8’ -6" 12" 13’ -9" BY Riprap, 500 lb class ENERGY DISSIPATOR BLOCK P TY Pacoi m aSGEnhancem ent . dgn C For reinforcement See Section B-B Symetrical @ C L 6" CADD PROJECT FI LE NAM E #5@9 212" REVI EW ED D R FO I L CA #5@18" DATE 60% PLANS MK OUTLET STRUCTURE DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.20 SHEET 20 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:38:42 PM 10" 4’-0" "X" 10" Metal Handrail Per Std Plan 606 12" "Y" See Table 1 Hereon 3 1 2" 24" #4 stirrups @12" 4-#4bars "X "R CP Ta bl e 1H er eo n 3 6" min Optional Constr Jt. 6" "X" embed. Bend bars 18" into slab 2" Se e 6" 9" I nv E l 6" 1’ -0" 1 S=0.00 15" 2" #4@18" 9" #4@18" 1’ 6" SECTION A1-A1 4’6" #4@18" both faces 4’ -0" #4 stirrups @ 12" 4-#4 bars 2" Lap 18" Lap 18" #4@18" both faces 8" SCALE:1/2"=1’-0" B1 5’-0" 7’-6" 7’-6" 5’-0" SECTION B1-B1 SCALE:1/2"=1’-0" 14" "X" 1 "Y" 5’ -0" 12" 12" 8" Symetrical @C L 14" 8" Wing wall 8" Wing wall 6" Varies from ("X/2"+6") to "Z" 24" 2" #4@18" 2" 4’-0" Var i es f r om H #5@18" 6" Constr Jt 3" #5@18" 6" "X" A1 SECTION C1-C1 "X/ 2" + HEADWALL SECTION D1-D1 SCALE:1/2"=1’-0" See Tabl e 1Her eon "Z" TYPICAL REINFORCEMENT NOT TO SCALE C1 Los Angeles County Department of Public Works INLET "I" SCALE:1/2"=1’-0" 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR "Y" "Z" 24" 10’-6" 5’-0" 36" 13’-6" 6’-6" NO. T S VI SAL TE EXP. C63209 CIVIL A T E DATE MK ENHANCEMENT PROJECT * 06/30/12 OF B1 PACOIMA SPREADING GROUNDS I A "X" CHARLES C. CHEN N INLET/OUTLET DIMENSIONS AND DATA D ER R EGIS TE R E TABLE 1 E IN 5’ -0" J.LI Unofficial and Subject to Change LOW FLOW INLET STRUCTURE G CHECKER PRELIMINARY N CHARLES C.CHEN D1 PLAN (SH. 17) E DESI GNER The Information Shown Hereon is * DRAFTER 1 #4@18" 6" A1 22" Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E > "X" RCP 9" "X/ 2" + 6" BY REVI EW ED C1 P C R 1 " l e X " b Ta ee S 2" Typ. See Tabl e 1Her eon "Z" Metal Handrail Per Std Plan 606 2" Typ. n eo er H 15" 2" DATE 2" 6" t o ( "X"+ 24") See Table 1 Hereon R FO I L CA LOW FLOW INLET STRUCTURE "I" DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.21 SHEET 21 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:39:16 PM 20’-8" 12" 27" 38’-3" 12" 27" 38’-3" 9.3’ typ. 10.4’ 1 3’ 3’ 3 18" 9" 8’-6" 8’-6" 18" 6" D 24" 24" S t e pf a c e( S f ) 9" 24" 4’ 12 "t yp . NOT TO SCALE 12" SECTION A-A NOT TO SCALE C 3 SECTION B-B 12" 12" 5’ 2 %t y p . 1 12" 9’-4" B 9" 9.3’ typ. 10.4’ C Var. (22’-4" to 9’-4") ( We s t B a s i n ) S f =9 3 9 . 1 5 Var . ( E a s t B a s i n ) S f = 9 3 8 . 7 4 ( We s t B a s i n ) S f =9 3 6 . 4 5 ( E a s t B a s i n ) S f = 9 3 6 . 1 6 BY REVI EW ED 8. 5’ D 12" ( 12"t o 5’ 4" ) 12" 8’-6" 12" 8" 8. 5’ A Exstdoubl e 8. 5’ W x3’ H RCB A 6" 44’ 8" DATE S e es e c t i o nDD f o r e l e v a t i o n 9" 3’ S t e pf a c e( S f ) SECTION C-C ( We s t B a s i n ) S f =9 3 3 . 7 2 9" 12" Pacoi m aSGEnhancem ent . dgn B 4’ CADD PROJECT FI LE NAM E NOT TO SCALE ( E a s t B a s i n ) S f = 9 3 3 . 5 7 5’ CHARLES C.CHEN 5’ J.LI The Information Shown Hereon is SECTION D-D PRELIMINARY FRONT VIEW NOT TO SCALE Unofficial and Subject to Change 60% PLANS PLAN (SH. 11) COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D VI SAL TE CIVIL A * 06/30/12 T E OF I A T S DRAFTER C63209 N EXP. ENHANCEMENT PROJECT ER * MK E IN CHARLES C. CHEN NO. DATE PACOIMA SPREADING GROUNDS G NOT TO SCALE N R EGIS TE R E OUTFALL STRUCTURE E DESI GNER CHECKER . yp "t 12 Los Angeles County Department of Public Works R FO I L CA OUTFALL STRUCTURE DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.22 SHEET 22 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/24/2012 9:44:07 AM "X" "X" "X" MASONRY #3 24" #4 32" 25" 24" #5 40" 31" 30" #6 48" 37" 36" #7 70" 54" 42" #8 80" 62" 48" #9 90" 70" 54" 19" 18" 1 4 D 2 2" MIN. 6 1 "X" R R " X" " X" " X" R "X" OTHER R REINF. TOP BAR " D" 12 D 4"M I N. CONCRETE CONCRETE STD. HOOKS NOTES: STD. HOOKS VERTICAL AT ALL 90 HOOK OFFSET 1.CONCRETE LAP LENGTH IS BASED ON CLASS B TENSION ’ SPLICE, Fc = 4,000 PSI AND GRADE 60 REBARS. END AND CORNER TYP. UNLESS NOTED 180 HOOK R= 3D FOR #2 THRU #8 BAR 4D FOR #9 THRU #11 BAR OTHERWISE 5D FOR #14 OR #18 BAR 2. TOP BAR IS THE HORIZONTAL REINFORCEMENTSO PLACED THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE SPLICE. CORNER INTERSECTION ALTERNATE AND ENDS CORNER CORNER INTERSECTION ALTERNATE AND ENDS CORNER REINFORCING LAP SPLICE SCHEDULE LAP SPLICE SEE SCHEDULE R DOUBLE CURTAIN REINFORCING . D 6 IN M " 4 NOTE: SINGLE CURTAIN REINFORCING "X" - LAP SPLICE PER DETAIL 2 RINFORCING LAP SPLICE SCHEDULE 1 MAX. SLOPE 6 LAP SPLICE R REINFORCING DETAILS AT CORNERS AND INTERSECTIONS REINFORCING STEEL DETAILS 135 BEND NOT TO SCALE NOT TO SCALE COLUMN TIE OR BEAM STIRRUP 2- #5 IN 8" BOND BEAM 7" DATE 2- #5 (TYP) 7" 8" STRUCTURAL NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE 1997 REVI EW ED 2- #5 IN UNIFORM BUILDING CODE. 16" BOND BEAM BY 2- #5 2. CONCRETE SHALL BE 4000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS. 3. MASONRY SHALL HAVE A SPECIFIED COMPRESSIVE 2- #5 IN 2- #5 16" BOND BEAM STRENGTH, f’m OF 1500 PSI. 4. REINFORCING STEEL SHALL BE GRADE 60. Pacoi m aSGEnhancem ent . dgn 2- #5 (TYP) FOOTING DOOR OPENING 2’ x 2’ LOUVER OPENING J.LI The Information Shown Hereon is PRELIMINARY CHARLES C.CHEN MASONARY WALL OPENING REINFORCEMENT DETAIL Unofficial and Subject to Change NOT TO SCALE 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS D G VI SAL TE T S DRAFTER C63209 CIVIL A * 06/30/12 T E OF I A EXP. ENHANCEMENT PROJECT ER * MK E IN CHARLES C. CHEN NO. DATE PACOIMA SPREADING GROUNDS N R EGIS TE R E S S I E O NA OF L PR E DESI GNER CHECKER 2’-8" x 2’-8" LOUVER OPENING Los Angeles County Department of Public Works FOOTING N CADD PROJECT FI LE NAM E 2- #5 R FO I L CA CONTROL HOUSE - BUILDING REINFORCEMENT DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.23 SHEET 23 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:41:25 PM 2’-0" H x 2’-0" W LOUVER WITH EXHAUST FAN CONCRETE ROOF PER DETAIL Sh. 28 SEE Sh 25 POLE MOUNTED AREA POLE MOUNTED AREA CONCRETE ROOF LIGHT (12-FEET HIGH) SEE Sh 25 LIGHT (12-FEET HIGH) 16’-4" 14’-0" 8" 6" 6" 8" 8" 6" 10’-8" 2’ 0" GRAY SPLIT 6" 6" 6" 8" 13’-0" FACE BLOCK BUILDING GRAY SPLIT FACE BLOCK 8’ 0" 5’ 8" 8’ 4" 8’ 4" BUILDING 2-INCH STAINLESS STEEL EXHAUST VENT 8" 2’-0" 2’-0" 16" 8" NORTH ELEVATION SCALE:1/2"=1’-0" EAST ELEVATION SCALE:1/2"=1’-0" LIGHT (12-FEET HIGH) LIGHT (12-FEET HIGH) SEE Sh. 25 LOUVER PER DETAIL Sh. 28 POLE MOUNTED AREA POLE MOUNTED AREA CONCRETE ROOF 2’-6" H x 2’-6" W CONCRETE ROOF SEE Sh 25 DATE 16’-4" 13’-0" 6" 8" 8" 6" 14’-0" REVI EW ED STEEL DOOR PER BUILDING BUILDING 7’ 2" 2’ 6" 8’ 0" GRAY SPLIT FACE BLOCK 8’ 4" GRAY SPLIT FACE BLOCK 8’ 4" BY DETAIL Sh. 28 2-INCH STAINLESS STEEL EXHAUST 3 1’ 64" 2’ 0" VENT 1’-0" 1’-0" 4’-0" 3’-4" 2’-8" EXHAUST VENTS SOUTH ELEVATION SCALE:1/2"=1’-0" WEST ELEVATION 60% PLANS SCALE:1/2"=1’-0" COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS Los Angeles County Department of Public Works S S I E O NA OF L PR D CHARLES C. CHEN VI SAL TE T S Unofficial and Subject to Change T E OF DATE 60% PLANS CIVIL A MK * 06/30/12 I A EXP. C63209 N * ENHANCEMENT PROJECT ER NO. PRELIMINARY PACOIMA SPREADING GROUNDS E IN R EGIS TE R E J.LI STEEL OHI GATE G CHECKER 2’-6" N CHARLES C.CHEN 2’-2" E DESI GNER 2-INCH STAINLESS The Information Shown Hereon is DRAFTER 8" 6" 10’-8" 7’-11/2" x 3’-0" x 1-3/4" Pacoi m aSGEnhancem ent . dgn CADD PROJECT FI LE NAM E 8" 6" 6" 6" R FO I L CA CONTROL HOUSE - BUILDING ELEVATIONS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.24 SHEET 24 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:42:04 PM TYP.ALL AROUND 3 "M AX.CLR 4 3 "M AX.CLR 4 TYP ALL AROUND 1-3/4" 14 GAGE STEEL DOOR AND FRAME CMU WALLREINFORCEMENT NOT SHOWN DOOR NOTES: (2) DEAD BOLT SHALL HAVE A HARDENED INSERT AND A 1" MINIMUM THROW WITH 3/4" MINIMUM EMBEDMENT INTO JAMB. (3) (4) CYLINDER GUARDS SHALL BE INSTALLED ON DEAD BOLTS WHENEVER THE CYLINDER PROJECTS BEYOND THE OUTSIDE FACE OF THE DOOR OR IS ACCESSIBLE TO ATTACK TOOLS. ALL HINGES TO HAVE NON-REMOVABLE PINS. SHIM AND SEALANT ALL AROUND 1 2" DIAMOND MESH EXPANSION METAL SCREEN WITH METAL FRAME AND SS SCREWS OD OF STL FRAM E NG M ASONRY OPENI (1) DOOR SHALL BE OPENABLE FROM THE INSIDE W/O USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 45STORM PROOF, 16 GAGE GALVANIZED STEEL, FIXED LOUVER WITH FACTORY PRIMED FINISH (5) LOCKS AND KEYS TO BE COMPATIBLE WITH AGENCY’S EXISTING SYSTEM. SHIM AND SEALANT ALL AROUND HARDWARE SCHEDULE: 3 - SETS OF HINGES 18 GA DRIP 1 - CLOSER 1 - MORTISE DEADBOLT WITH LEVER TRIM AND STRIKE EXTERIOR 1 - HOLDER (FLOOR) INTERIOR 1 - SET WEATHERSTRIPPING 3 " 8 x 4" EXPANSION ANCHOR @ MAX 24" OC MIN. 3 PER SIDE 1 - RAINDRIP 1 - WALL STOP LOUVER DETAIL 1 - SWEEP NOT TO SCALE EXTERIOR FACE 1/4" STEEL PLATE WITH CUT OUT FOR EXHAUST FAN. MOUNT TO CMU WALL WITH 3/8" EPOXY MASONRY ANCHORS @ 12" O.C. GALVANIZED STEEL LOUVER WITH BIRD SCREEN PER DETAIL 2 CMU WALL HOLLOW METAL DOOR REVI EW ED DOOR SWEEP BY CONCRETE LANDING 1 " 2"x2"x 4 GALVANIZED STEEL ANGLE EMBEDDED IN CONCRETE SEALANT EXHAUST FAN CONCRETE SLAB Metal threshold with CONCRETE ANCHOR @ 30" O. C. MAX width across door opening. Secure with Pacoi m aSGEnhancem ent . dgn INSIDE @ 12" O.C. MAX. 1/ 2" MASONRY OPENING OUTSIDE SIDEWALL PROPELLER FAN SEE FAN SCHEDULE BELOW RUBBER SILENCERS HOLLOW METAL DOOR Concrete slab FAN SCHEDULE Sealant EXTERIOR DOOR THRESHOLD 5" FAN NUMBER HEAD/JAMB EF-1 MAKE/ MODEL NUMBER GREENHECK/ S1-12-432-D AIRFLOW (CFM) 1042 STATIC PRESSURE (IN W. G. ) VOLT 0.25 120 HP RPM 1/8 1550 PHASE Los Angeles County Department of Public Works 1 The Information Shown Hereon is J.LI WALL MOUNTED FAN AND LOUVER PRELIMINARY NOT TO SCALE DOOR DETAILS NOT TO SCALE CHARLES C.CHEN Unofficial and Subject to Change 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR D N G T S VI SAL TE C63209 CIVIL A * 06/30/12 T E OF I A EXP. ENHANCEMENT PROJECT ER * MK E IN CHARLES C. CHEN NO. DATE PACOIMA SPREADING GROUNDS E R EGIS TE R E CHECKER PLATE 4" N CADD PROJECT FI LE NAM E 2-unit cinch anchors INTERIOR DOOR SILL DRAFTER 1 " STEEL 4 DOOR FRAME WITH GROUT 1/4"F.H. screws & 3" WELDED STUDS @ 18" O. C. (MIN 2 PER ANGLE) 4" Door vinyl insert. Run full DESI GNER M ASONRY EXTERIOR FACE 3 8" EPOXY ANCHORS @ 12" O.C. OPENI NG PER ARCHI TECTURAL DRAW I NGS DATE TYPE R FO I L CA CONTROL HOUSE - DOOR LOUVER AND FAN DETAILS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.25 SHEET 25 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:42:34 PM B 1/100 HUBBEL No. RTS-4121-PO ROUND TAPERED STEEL POLE (HEIGHT 12’). PAINT POLE TO MATCH FIXTURE 3, +18" LP "A" PLATED STEEL MOUNTING BRACKETS (TYP.) 1 2" O x 3", 316 S. S. EXPANSION BOLT 1 (4) 2"-15"x3" GALVANIZED ANCHOR BOLTS CONCRETE ROOF CONCRETE WALK 6" / 2" 3 A S 2 2/40 1/100 S 1 3, +18" 4 4 4’ 0" B 4 4-#6 VERT. LP "A" CKT 3 LP "A" CKT 4 WATERTIGHT END HUB (TYP.) LP "A" CKT 1 3 " PVC COATED RIGID 4 STEEL CONDUIT (TYP.) #4 HORIZ. EVERY 8" A 1’-0" ROUND 2/40 3, +18" FLOURESCENT FIXTURE MOUNTING DETAIL AREA LIGHT DETAIL 1 2 NOT TO SCALE NOT TO SCALE RUBBER DAM CONTROL BUILDING DATE MOUNTING: BUS: 100 AMP 1 PHASE 240/120 VOLTS WATTAGE REVI EW ED OA BY 110 Pacoi m aSGEnhancem ent . dgn R E C DESCRIPTION L T G P O L B K R C I R 1 C I R A E B K R P O L L T G R E C DESCRIPTION OA 1 2 15 1 1 20 3 4 15 1 PLC 1 15 5 6 15 1 DRYER SPARE 1 15 7 8 15 1 SPARE SPARE 1 20 9 10 15 1 SPARE SPARE 1 20 1 1 12 15 1 SPARE 3 RECEPT WATTAGE E B 1 15 EXTERIOR LIGHTS 540 410 3 WIRE OB 300 CADD PROJECT FI LE NAM E MAIN: 30 AMP LIGHTING PANEL "A" WALL INTERIOR LIGHTS 100 600 TOTAL WATTS = 2630 MAKEUP AT MOTOR DETAIL NOT TO SCALE (UFER) GROUND DETAIL 1000 WATTS/LINE 540 CONCRETE ENCASED 600 WALL FAN 3 OB NOT TO SCALE 1100 AMPS = 10.8 LIGHTING PANEL "A" SCHEDULE WATTS/ MARK VOLTAGE DESCRIPTION LAMP REMARKS GROUND ROD AND WELL DETAIL DETAIL Los Angeles County Department of Public Works NOT TO SCALE DUST AND MOISTURE RESISTANT. EWL042R-SPDR-E1 OR EQUAL PRELIMINARY 2-4’ LAMP CONFIGURATION Unofficial and Subject to Change POLE-MOUNTED, B 1/100 120 VAC 100 100 WATT HPS LAMP WITH PHOTOCELL HUBBELL NO. RTS-4121-PO CONTROL ALUMINUM HOUSING, INTEGRAL BALLAST, HIGH STEEL POLE. IMPACT POLYCARBONATE LENS, ANDPOWDERCOAT HUBBELL MAGNUSQUARE 1 FINISH SERIES SQS-0100S-2W8-A1-L LUMINARIE: 2 60% PLANS COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR C63209 T E OF MK * I A 06/30/12 CIVIL A ENHANCEMENT PROJECT N EXP. DATE PACOIMA SPREADING GROUNDS ER * T S VI SAL TE CHARLES C. CHEN NO. LIGHT SCHEDULE DRAFTER D E IN R EGIS TE R E J.LI 40 1 G CHECKER 120 VAC HUBBELL DMR SERIES N CHARLES C.CHEN 2/40 The Information Shown Hereon is WITH WHITE ENAMELED REFLECTORS. E DESI GNER FLUORESCENT FIXTURE INDUSTRIAL TYPE A R FO I L CA CONTROL HOUSE ELECTRICAL LIGHTING INSTALLATION DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.26 SHEET 26 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:43:05 PM A 14’-0" 8" 16" 2’-0" 16’-4" A Stilling well Removable grating panel See Sh. XX 10’ 8" 3’4" 4’ 8" 13’ 0" 10’ 8" COMP. 2’ 0" 14’-0" 5’0" 2’ 6" APC PLC 8" BUBBLER C B 8" 24" 16" 8" 6" PVC Pipe ROOF PLAN SCALE: 1/2"=1’-0" 8" 8" CONC. BLOCK SOLID GROUTED DATE ) 4 1 SH. AN( ONPL I OUNDAT OORANDF L F #4 @ 24" #4 @ 8" AT MID-DEPTH OF SLAB NOT TO SCALE ALT. BEND ROOF WIDTH WATERPROOFED REINFORCED CONCRETE ROOF SLAB SEE SECTION C-C #4 @ 24" FLOOR WIDTH 8" 6" #4 DOWELS @ 24" 6" 6" 8" 2’ 0"LAP BY REVI EW ED 6" 2- #4 CONT. 2’-0" #5 2’ 0"M I N. 4" 8’ 0" #4 @ 12" AT MID-DEPTH OF SLAB 12" 20" EXTERIOR SHALL BE PROOFED AND PAINTED WITH ANTI-GRAFFITI COATING WITH ELASTO-GLAZE 6001AG BY PACIFIC POLYMERS OR APPROVED EQUAL 8’ 4" Pacoi m aSGEnhancem ent . dgn 8" CONC. BLOCK SOLID GROUTED #4 @ 24" 6" WALL AND FOOTING REINFORCEMENT SEE SECTION C-C 0" 8’ CADD PROJECT FI LE NAM E 2-#5 COMPACTED SAND 3- #5 ALT. J.LI SECTION C-C 2’-0" BEND TYP. ROOF TO WALL DETAIL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS Los Angeles County Department of Public Works S S I E O NA OF L PR CHARLES C. CHEN EXP. VI SAL TE DRAFTER T S SECTION A-A Unofficial and Subject to Change SCALE: 1/2"=1’-0" CIVIL A MK * 06/30/12 T E OF DATE 60% PLANS C63209 I A * ENHANCEMENT PROJECT ER NO. PRELIMINARY PACOIMA SPREADING GROUNDS E IN The Information Shown Hereon is D N STILLING WELL, SEE DETAIL ON SH 30 G R EGIS TE R E W ELL DEPTH SCALE: 1"=1’-0" N COMPACTED SAND SCALE: 1"=1’-0" NG I OOT LF ORWAL ERI EXT YP. T E CHARLES C.CHEN SECTION B-B 4" DESI GNER REINFORCED CONCRETE FLOOR SLAB SEE SECTION B-B 6" CHECKER 8" R FO I L CA CONTROL HOUSE - PLAN AND SECTIONS DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCC0001207 JOB EF11610123 DWG 21-D114.27 SHEET 27 OF 29 PS-DF 07/05 DATE. TIME. $DATE$ FILE. $TIME$ $FILEL$ FCC0001207 - PACOIMA SG IMPROVEMENTS-VT.dgn 05/23/2012 1:43:33 PM MB GATES AND EMO’S SCHEDULE EMO with Bevel Gear Drive > Gate Size Qty. Max. WSE Max. Head Stem Dia. Min. Stem Stem Guide Bevel Gear Motor Power Output Torque Thrust Rating (Ft) (Ft) (Ft) (Inches) Guides Interval (Ft) Reducer Output (HP) (FT-lb) (Lb.) W. Settling Basin to 3 Cast-iron slide gate 24"x24" 1 929.0 941.0 13.0 3.25 1 6.0 6:1 0.5 540 54,000 Basin 3 to 4 Cast-iron slide gate 24"x24" 1 922.0 936.0 15.0 3.25 1 6.0 6:1 0.5 540 54,000 Basin 4 to 5 Cast-iron slide gate 24"x24" 1 914.0 924.0 11.0 3.25 1 6.0 6:1 0.5 540 54,000 Basin 5 to 6 Cast-iron slide gate 36"x36" 1 905.0 916.0 12.5 3.25 1 6.0 6:1 0.5 540 54,000 Basin 6 to 60" Lateral Cast-iron slide gate 36"x36" 1 898.0 908.0 11.5 3.25 1 6.0 6:1 0.5 540 54,000 E. Settling Basin to 1 Cast-iron slide gate 24"x24" 1 929.0 941.0 13.5 3.25 1 6.0 6:1 0.5 540 54,000 Basin 1 to 2 Cast-iron slide gate 36"x36" 1 918.0 930.0 13.5 3.25 1 6.0 6:1 0.5 540 54,000 Basin 2 to 6 Cast-iron slide gate 36"x36" 1 907.0 917.0 11.5 3.25 1 6.0 6:1 0.5 540 54,000 Transducer pull box Flow Gate Type Inv. El. w/ support bracket RCP inlet for low flow 212" PVC electrical conduit Steel pipe stem cover EMO w/ bevel gear and 18" handwheel for Cast-iron slide gate Slot sight Stem cover, see DETAIL "M1", EMO Indicator Sheet M-3 Transducer pull box, EMO Indicator Transducer pull box 18" Dia. Handwheel see DETAIL "2" Sheet M-3 Transducer pull box > Disconnection box 4-Inch Sch. 80 ASTM A53, height per EMO manufacturer Pedestal bottom flange (Typ.) 36" Max. S.S. strut channel w/ base Bevel gear reducer MA MA 3’ MB 1" Dia. x 12" hook anchor bolt w/ 834" embedment. Wall bracket Wall bracket Power panel Per gate Stem guide manufacture Telemetry cabinet support bracket, 2-foot long Transducer pull box 22" Schedul e" w/ support bracket 212" PVC Sch. 80 pipe p e r st ru ct u re Cast-iron slide 18" gate assembly FLOW > Invert elevatons, see "Gates and EMO’s "Gates and EMO’s Schedule 12" Schedule Box-out per PONGPUN TYPICAL EQUIPMENT LAYOUT gate manufacture. Transducer standpipe detail, Grout filled after see DETAIL "3" Sheet M-3 gate installtion. FOR INTERBASIN STRUCTURES SCALE: 1/2" = 1’-0" M-1 "E" Section circular wall COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS thimble w/ 9" depth S S I E O NA OF L PR R EGIS TE R E ENHANCEMENT PROJECT * 6/30/2012 EXP. T S AND WALL BRACKET DETAILS SCALE: 1/2" = 1’-0" MECHANICAL A T E OF DATE MK I A TYPICAL WALL THIMBLE, STEM GUIDE, M-029732 NO. * N O.P./Z.M. SCALE: 1/2" = 1’-0" PETER CHANG ER SECTION MB-MB, PACOIMA SPREADING GROUNDS E IN AND EMO ELEVATIONS D G TYPICAL CAST-IRON SLIDE GATE N O. SECTION MA-MA, E DESIGNER L 3"x3"x38" S.S. Invert elevatons, see > DRAFTER see " Gat es and EM O’ s St em gui de i nt er val , Stem guide V a ri e s TJAN M. BY CHANG gate manufacturer. (Typ.) P. CHECKER CADD PROJECT FILE NAME REVIEWED DATE The Cont r act orshal lver i f i ed t he hei ghtofeach st r uct ur e wi t h Dr ai nage Dr awi ngs. Quantity and spacing per R FO I L CA TYPICAL EQUIPMENT LAYOUT FOR INTERBASIN STRUCTURES DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCCXXXXXX JOB XXXXX DWG XXXX SHEET 28 OF 29 PS-DF 5/99 DATE. $DATE$ TIME. $TIME$ FILE. $FILE$ Pacoima SG ME 60%.dgn 05/23/2012 1:46:06 PM ME Stainless steel Davit crane Flow meter and boom with adjustable boom and in operating position rotating mast, 500 lbs load rating 1 2" Cord grip connector Area velocity MF 12" Channel wall Screw-jack w/ handle radar flow meter 212" PVC female adapter Rotating mass 42" MF 212" PVC bushing 4’ 10"M ax Flow 18’M ax 30"M ax. 8"x8"x4" NEMA 1 212"x12" Reducing washer 212" PVC Schedule 80 Level transmitter cable Flow meter and boom DETAIL "2" PRESSURE TRANSDUCER J-BOX 12" 18" 5’ 0" Pedestal base in maintenance position NOT TO SCALE 7’-0" 2" Dia handrail 24" Electrical panel 8’-0" Concrete pad 8’-0" PVC Schedule 80 pipe ME Flow 1 5/8"x1 5/8" strut channel w/ 212" pipe clamp Flow Level transmitter STATION LAYOUT 6" TYPICAL FLOW METER SCALE: 1/2" = 1’-0" #10-32 UNF threaded rod, stainless steel, w/ two nuts 6" and sealing washers Structure Invert DETAIL "3" TRANSDUCER STANDPIPE END, (TYP.) DATE SCALE: 1/8" = 1’-0" > TJAN FILE ASTM A53 Type E Gr. A Gate travel Top of stem (Gate Open) #8-32 Hex HD zinc plated THD cutting screw. SCALE: 1/2" = 1’-0" SCALE: 1/2" = 1’-0" Graduated scale in feet & tenths engraved on one retainer bar Stainless steel retainer bar " Wide slot cut on pipe Transparent Lexan plastic slot cover Top of stem (Gate Closed) CADD Top of operator CHANG DETAIL "M1" STEM COVER PONGPUN P. NOT TO SCALE M-2 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS S S I E O NA OF L PR E IN PETER CHANG ER M-029732 NO. * ENHANCEMENT PROJECT * 6/30/2012 T E OF I A MECHANICAL A N O.P./Z.M. EXP. T S DRAFTER PACOIMA SPREADING GROUNDS G R EGIS TE R E D N O. CHECKER SECTION MF-MF E DESIGNER 4" C to C SECTION ME-ME 5" PROJECT Sch. 40 galvanized steel pipe 2" Pipe length as required BY 2" M. 2" " Dia. vent hole at 90 to slot NAME REVIEWED Galvanized steel pipe cap R FO I L CA TYPICAL FLOW METER STATION AND INSTRUMENTATION DETAILS DATE MK DESCRIPTION REVISIONS PROJECT ENGINEER DATE FCCXXXXXX JOB XXXXX DWG XXXX SHEET 29 OF 29 PS-DF 5/99 DATE. $DATE$ TIME. $TIME$ FILE. $FILE$ Pacoima SG ME 60%.dgn 05/23/2012 1:46:46 PM This page intentionally left blank.