Comments
Transcript
Welcome to Mongolia Page 1 Bjoern Wahlstedt
Implemented by Welcome to Mongolia ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 1 Implemented by with winter temperatures of sometime 70 degrees colder than here in Chiang Mai today ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 2 Implemented by Energy Efficiency Project (ENEV) Phase III A cooperation between • Ministry of Energy • Cabinet Secretariat • SDC • GIZ (BMZ) A general project presentation of the activities in the three components for 2014 – 2016 Utilizing Energy Efficiency to demonstrate, develop, and improve Good Governance ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 3 Implemented by Mongolian Partner: Cabinet Secretariat Mongolian Partner: Cabinet Secretariat Outcome 1: Compliance with Budget and Procurement Laws relating to capital investments at local level has improved Outcome 2: Improved Energy Efficiency of public buildings in Khovd and Zavkhan aimags demonstrated Outcome 3: Public institutions companies and households have intensified efforts and increased investments in the area of energy efficiency and energy Mongolian Partner: conservation Ministry of Energy Shared by: – BMZ (GIZ) Other Partners: Energy Regulatory Commission ENEV III Project. Version: NEXUS 18 June 2015. Budget: EUR 7,700,000 – SDC Bjoern Wahlstedt Page 4 Implemented by What we are currently doing and what will be the results when this project phase is finished? ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 5 Implemented by Improved Energy Efficiency of public buildings • Improved qualifications of the private sector on the local levels for the implementation of energy efficiency projects • Available evidence of the benefits from thermo-insulation of public buildings area • Created a conducive environment for the rational and structured operation, maintenance and rehabilitation of public buildings • Reached an agreement between the users of public building and heat suppliers on energy efficiency and energy savings based on a fact based dialogue • Strengthened ability of the local government to develop action plans, standards and protocols, and capability to enforce them ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 6 Implemented by What do you think is the main reason for the public buildings being cold? Heat loss 16% Insufficient heating 24% 4% 17% Expensive coal and insufficient supply Building quality 38% 1% ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Extreme cold temperatures Aged building Page 7 Implemented by Result from survey What do you think is the main reason for the public buildings being cold? Heat loss 16% Insufficient heating 24% 4% 17% Expensive coal and insufficient supply Building quality 38% 1% ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Extreme cold temperatures Aged building Page 8 Implemented by Some pictures from the practical renovation work of Kindergarten #5 in Khovd during summer of 2014 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 9 Implemented by Kindergarten in Khovd: Picture from thermal (IR) camera before renovation. Picture from the renovation and insulation of the Kindergarten. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 10 Implemented by The kindergarten before the refurbishment. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 11 Implemented by This is not a very inviting environment for a 4-year old girl. Urinary infections are probably rather common. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 12 Implemented by The renovation included: • Ceilings and roofs • Walls • Windows • Doors • Floors ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 13 Implemented by There was a very clear division between female and male tasks. 58 windows were changed to 2-glass vacuum type. Most of the materials were produced locally. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 14 Implemented by The task to instruct how to get a right angle could be a challenge. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 15 Implemented by And how to use a label also needed thorough and hands-on instructions. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 16 Implemented by The principle for the wall insulation method. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 17 Implemented by Cooperation with the TVET project provided training of the staff of the construction companies involved. The “students” got a certificate for their participation in the training and practical work. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 18 Implemented by Workers’ safety... ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 19 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 20 Implemented by The radiators were more or less completely clogged. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 21 Implemented by Monitoring of • indoor temperature • outdoor temperature • incoming heating water • outgoing heating water • total energy amount provide valuable facts for evaluation. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 22 Implemented by Outdoor signboards have increased the interests in Energy Efficiency and what the project is doing. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 23 Implemented by Showing that the indoor temperatures are still high during very cold periods are hard facts to prove that insulation is efficient. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 24 Implemented by Energy Efficiency Certificate for the Kindergarten in Khovd to be renovated (draft). The target was to improve the standard (energy consumption / m2 and year) from E to B. Around 50% reduction of energy consumption is reached. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 25 Implemented by Some examples of temperature measurements from insulated and not insulated kindergartens in Khovd and Zavkhan. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 26 The respective kindergartens №5 in Khovd and Zavkhan are the same type of building Khovd №5 Khovd №7 Zavkhan №5 Zavkhan №7 1975 1989 1976 1985 2 2 2 1 800 m2 680 m2 800 m2 593 m2 Heated building volume 2 398 m3 2 340 m3 2 398 m3 2 745 m3 Children planned/current 125/180 90/228 125/250 90/130 Renovation Yes No Yes No Connected to heat supply grid Yes Yes Yes No Construction year Floors Heated floor space ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 27 Khovd: Kindergarten #5. Insulated. 70.00 60.00 50.00 40.00 30.00 20.00 10.00 Indoor temperatures 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd: Kindergarten #5. Insulated. 70.00 60.00 50.00 40.00 30.00 20.00 10.00 Outdoor temperatures 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd: Kindergarten #5. Insulated. Temp indoors Temp outdoors Water in Water out 70.00 60.00 50.00 40.00 30.00 20.00 Incoming heating water temperatures 10.00 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Khovd: Kindergarten #5. Insulated. Temp indoors Temp outdoors Water in Water out 70.00 60.00 50.00 40.00 30.00 20.00 Outgoing heating water temperatures 10.00 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Khovd: Kindergarten #5. Insulated. 70.00 60.00 50.00 Large jumps in indoor temperatures due to warmer outdoors, same heat supply, holidays, manual (lack of) regulations, etc 40.00 30.00 20.00 10.00 0.00 Indoor temperatures 20 – 23 degrees regardless of outdoor temperatures. -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd: Kindergarten #7. NOT insulated. 90.00 80.00 Cold indoor temperatures. 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 The indoor temperature goes down to 8 degrees! -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd Kindergarten #5 Insulated Temp indoors 26.00 25.00 24.00 23.00 22.00 21.00 20.00 19.00 18.00 Why are five days in a row warmer than the two remaining? Why are there two peaks during some days? 17.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Khovd Kindergarten #5 Insulated Temp indoors 26.00 25.00 24.00 23.00 22.00 21.00 20.00 19.00 18.00 17.00 In a well insulated building even small additions of heat will have an impact – in this case the “heat supply” from 200 children and staff is producing 15 – 20 kW. The Monday – Friday patterns are very different from the weekend patterns. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Khovd Kindergarten #5 Insulated Temp indoors 26.00 25.00 24.00 23.00 22.00 21.00 20.00 19.00 18.00 17.00 The breakfasts and lunches are prepared in the kitchen and eaten in the rooms which adds additional heat to the rooms during two significant periods every day. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Implemented by What are the Energy Efficiency results so far? • Manual regulation of the radiators do not make use of the full saving potential. Thermostats need to be installed in the radiators. Practically, the indoor temperatures are regulated by opening the windows. • A system for regulating the incoming water temperature (energy) is needed. Probably this system needs to be automatic. • Monitoring locations and techniques must be chosen to avoid being influenced by non-relevant parameters. • The special applications to estimate the energy consumption needed before and after renovation indicates energy ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt savings of 50%! Page 37 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 38 Implemented by Technical support through equipment ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 39 Implemented by The thermographic measurement camera provides images to assess and monitor the energy leakages in buildings. The more yellow the more leakages and money losses. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 40 Implemented by Environmental air pollution aspects ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 41 Implemented by Ineffective heating systems also cause heavy air pollution problems through the large amount of smoke from chimneys. Pictures from Khovd in January 2015. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 42 Implemented by The meteorological conditions during winter cause so called “inversions”. That means that a “lid” is established in the atmosphere at an altitude of 100 – 300 meters which effectively blocks the air pollution from dispersing. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 43 Implemented by The smoke from the high chimney to the right is seen moving in the weak wind to the left – but under the inversion layer. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 44 Implemented by The smoke from the large amounts of low chimneys add to the air pollution levels. All smoke accumulates under the inversion. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 45 Implemented by From a distance it is easy to see and imagine the unhealthy pollution levels. A qualified estimate without instruments places the level of particular matters (PM10) at 1,000 µg/m3 or more. The World Health Organization (WHO) limit is 40 µg/m3. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 46 Implemented by Matching funds arrangements ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 47 Implemented by In addition to the two already refurbished kindergartens in Khovd and Zavkhan, the project will renovate and insulate * a dormitory in Tes, * a school in Zavkhanmandal, * a clinic in Erdenekhairkhan soum, * a health center in Duut soum, and * school # 2 in Jargalant soum, under the Matching Fund arrangement during 2015. The choice of buildings has been made based on a number of criteria. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 48 Implemented by The initial arrangements include a 50 - 50 sharing between SDC/BMZ and the Mongolian side. Due to the troublesome financial situation for the Mongolian Government, the Local Development Funds (LDF) have been cut by 37% ─ and more reductions could come. After discussions and adjustments, the average proportion is around 60 – 40. The aimags have allocated a proportionally larger part of the reduced LDFs to the Matching Funds than to other projects. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 49 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 50 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 51 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 52 Implemented by Tes: Wooden dormitory 1,009 m2 100 children Estimated cost: 606,000,000 MNT 288,000 EUR ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 53 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 54 Implemented by Monitoring of temperatures and fuel consumption is crucial for the follow-up and conclusions of impact. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 55 Zavkhan: Tes soum. School. NOT insulated. 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 -10.00 -20.00 -30.00 -40.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Implemented by Erdenekhairkhan: Concrete health center 550 m2 15 beds Estimated cost: 222,000,000 MNT 106,000 EUR ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 58 Implemented by Hazardous medical waste destruction centre ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 59 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 60 Zavkhan: Erdenekhairkhan soum. Health center. NOT insulated. 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 62 Implemented by Zavkhanmandal: Wooden school 585 m2 160 children Estimated cost: 257,000,000 MNT 122,000 EUR ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 63 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 64 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 65 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 66 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 67 Implemented by Jargalant: Concrete school No2 4,577 m2 920 children Estimated cost: 770,000,000 MNT 366,000 EUR (without floor insulation) ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 68 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 69 Khovd Jargalant: School Nr 2. 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 -10.00 -20.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd Jargalant: School Nr 2. Room 312. 20.00 15.00 10.00 5.00 0.00 -5.00 -10.00 -15.00 -20.00 -25.00 -30.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Implemented by In the following graphs, please note the difference how the incoming water temperatures vary with the performance of the stoker. The outgoing water temperatures vary with the incoming temperatures ─ of course, but also with the effectiveness of the heating system (pipe lengths, flow rates, etc) ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 72 Zavkhan: Tes soum. School. NOT insulated. 60.00 40.00 20.00 0.00 -20.00 The stoker performs rather well, but the quality of the heating system is very poor with low temperatures. -40.00 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Zavkhanmandal: School for 160 children. NOT insulated. 80.00 60.00 40.00 20.00 0.00 20.00 40.00 The stoker has a clear diurnal working schedule. With better performance the building would have been reasonably warm but the quality of the building is low. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd: Duut soum. Health center. NOT insulated. 70 60 50 40 30 20 10 0 -10 -20 -30 The stoker wakes up rater late every morning. The building’s capacity to “store” heat is very low. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Temp indoors Temp outdoors Water in Water out Khovd Jargalant: School Nr 2. NOT insulated. Temp indoors Temp outdoors Water in Water out 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 -10.00 -20.00 -30.00 The district heating system provides a rather steady supply. The usage of the heat is rather good, but the quality of the building is very poor. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Implemented by Budget and tariff issues ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 77 Implemented by You and we are spending large budgets on renovations but... • the heat tariffs are flat (per area or volume)!!! • reduced heat demands might encourage the heat supplier to reduce the amount of heat – but still receive the same payment • reduced heat costs might reduce the public building budget for next year • Where is the incentive? • Who benefits? • Good Governance will provide better Energy Efficiency ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 78 Implemented by Basic economic estimates based on standardized figures • Costs for refurbishment of a kindergarten: 250,000,000 (€ 120,000) • The Government calculates 0% for ”internal” loans for investments Depreciation time: 20 years Capital costs per year: 12,500,000 ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 79 Implemented by Basic economic estimates based on standardized figures (Kindergarten #5 in Khovd for 2012) 350,000,000 [SERIES NAME] 300 M 300,000,000 250,000,000 200,000,000 Salaries 150,000,000 100,000,000 [SERIES NAME] 60 M = 20% Misc 50,000,000 Electricity Water Maintenance 0 Total budget ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 80 Implemented by Basic economic estimates based on standardized figures The conclusion is easy: It pays to renovate a public building Assumed heat savings are 50% = 30,000,000 (€ 14,000) Compared to the capital costs for refurbishing = 12,500,000 (€ 5,800) BUT The tariffs are flat so what is the purpose…??? The pay-back calculations for the costs for renovation are heavily dependent on the financing arrangements and the tariff structure ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 81 Implemented by ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 82 Implemented by Balancing various costs (easy to estimate) vs other benefits (difficult to estimate) - Capital costs - Heating costs + Healthier children with higher quality of life + Less sickness (medication, hospital) costs + Less need for parents to stay at home nursing their sick children + Improved learning conditions will increase the assumed productivity long term + Improved environmental conditions through less coal burning ? What is worth doing? ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 83 Implemented by Conclusions ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 84 Implemented by A well functioning heating system in a well insulated school, kindergarten, health centre, etc... ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 85 Implemented by ... will make children and adults happy and healthy, and eager to learn for life… … and money will be saved, but the tariffs must be realistic! ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 86 Implemented by Thank you and we look forward to informing you again about our project during the next NEXUS meeting. ENEV III Project. Version: NEXUS 18 June 2015. Bjoern Wahlstedt Page 87 As a federal enterprise, GIZ supports the German Government in achieving its objectives in the field of international cooperation for sustainable development. Published by Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Responsible Björn Wahlstedt Author(s) Björn Wahlstedt Photo credits © GIZ/Björn Wahlstedt Registered offices: Bonn and Eschborn, Germany “Energy Efficiency in the Grid-Connected Energy Supply” Ministry of Energy Chinggis Avenue. Khan-Uul District, Room 102 Ulaanbaatar 17060 In cooperation with T +976 7011 1890 F +976 7004 1890 M +976 9191 9087 E [email protected] I www.giz.de Bjoern Wahlstedt Page 88