Comments
Description
Transcript
RFSW1012 BROADBAND SPDT SWITCH Features
RFSW1012 RFSW1012 Broadband SPDT Switch BROADBAND SPDT SWITCH GND RF2 GND Package: QFN, 12-Pin, 2mm x 2mm x 0.55mm 12 11 10 Features 5MHz to 6000MHz Operation 50 or 75 Applications GND 1 9 VDD 2 8 EN High Isolation: 37dB at 2GHz GND 3 7 CTRL High IP3: >75dBm at 2GHz Compatible with Low Voltage Logic (VHIGH Minimum = 1.3V) No External DC Blocking Capacitors Required on RF Paths Unless DC is Applied Externally 2000V HBM ESD Rating on All Ports CTB/CSO: >100dBc (41dBmV/ch., 137 Channels) Applications LTE, WCDMA, GSM CATV, SATV Applications Post PA Switching 4 5 6 GND RF1 RFC GND Low Insertion Loss: 0.30dB at 1980MHz Functional Block Diagram Product Description The RFSW1012 is a single-pole double-through (SPDT) switch designed for applications requiring very low insertion loss and high power handling capability. The excellent linearity performance of the RFSW1012 makes it ideal for use in LTE, WCDMA, and CDMA applications. This switch is ideally suited for use in CATV and SATV applications. The RFSW1012 is packaged in a compact 2mm x 2mm x 0.55mm, 12-pin, QFN package. General Purpose Switching Applications Ordering Information RFSW1012SQ RFSW1012SR RFSW1012TR13 RFSW1012PCK-411 RFSW1012PCK-410 25-Piece sample bag 7" Sample reel with 100 pieces 13" Reel with 2500 pieces 50 PCBA with 5-piece sample bag 75 PCBA with 5-piece sample bag Optimum Technology Matching® Applied GaAs HBT GaAs MESFET InGaP HBT SiGe BiCMOS Si BiCMOS SiGe HBT GaAs pHEMT Si CMOS GaN HEMT BiFET HBT Si BJT RF MICRO DEVICES®, RFMD®, Optimum Technology Matching®, Enabling Wireless Connectivity™, PowerStar®, POLARIS™ TOTAL RADIO™ and UltimateBlue™ are trademarks of RFMD, LLC. BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and registered trademarks are the property of their respective owners. ©2012, RF Micro Devices, Inc. DS120601 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 1 of 11 RFSW1012 Absolute Maximum Ratings Parameter Maximum VDD Rating Unit 6.0 V Maximum EN 3.0 V Maximum CTRL 3.0 V Hot-Switching Max Input Power (50 load) 20 dBm 31dBm: 5MHz to 25MHz, 50 load 34dBm: 25MHz to 500MHz, 50 load 37dBm: >500MHz, 50 load 36dBm: >500MHz, 6:1 VSWR dBm Operating Temperature (TCASE) -40 to +85 °C Storage Temperature -40 to +150 °C Max Input Power ESD Rating (HBM) Class 2 Moisture Sensitivity Level MSL-2 Specification Min. Typ. Max. Parameter Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. The information in this publication is believed to be accurate and reliable. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended application circuitry and specifications at any time without prior notice. RFMD Green: RoHS compliant per EU Directive 2002/95/EC, halogen free per IEC 61249-2-21, < 1000ppm each of antimony trioxide in polymeric materials and red phosphorus as a flame retardant, and <2% antimony in solder. Unit 50 Performance Using SW1012-411(A) EVB Nominal Test Conditions Unless Otherwise Stated: VDD = 3V, T = 25°C, All RF ports terminated in 50 Operational Frequency Range 5 Insertion Loss (RFC to RF1/RF2) Isolation (RFC to RF1/RF2) Isolation (RF1 to RF2) Condition 6000 MHz 0.25 0.40 dB 915MHz 0.30 0.45 dB 1980MHz 0.40 dB 2650MHz 0.45 dB 5850MHz 38 45 dB 915MHz 33 37 dB 1980MHz 33 dB 2650MHz 21 dB 5850MHz 42 dB 915MHz 35 dB 1980MHz 32 dB 2650MHz 21 dB 5850MHz Return Loss (On-State) >15 dB Input IP3 75 dBm 2.2GHz, 24dBm per tone, 1MHz spacing Input IP2 129 dBm Tone 1: 836.5MHz at +26dBm; Tone 2: 1718MHz at -20dBm; Rx Freq: 881.5MHz 129 dBm Tone 1: 1880MHz at +26dBm; Tone 2: 3840MHz at -20dBm; Rx Freq: 1960MHz Spurious Output <-105 dBm Freq >5MHz, all ports terminated, no RF Inputs <-100 dBm Freq <5MHz, all ports terminated, no RF Inputs dBc PIN = 35dBm 900MHz Second Harmonic -95 900MHz Third Harmonic -90 -75 dBc 1800MHz Second Harmonic -95 -75 dBc 1800MHz Third Harmonic -90 -75 dBc Max Operational Input Power 2 of 11 5MHz to 6GHz -75 PIN = 33dBm 30 dBm 5MHz to 25MHz, 50 load 33 dBm 25MHz to 500MHz, 50 load 36 dBm >500MHz, 50 load 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD DS120601 RFSW1012 Specification Min. Typ. Max. Parameter Unit 75 Performance Using SW1012-410(A) EVB Condition Nominal Test Conditions Unless Otherwise Stated: VDD = 3V, T = 25°C, All RF ports terminated in 75 Operational Frequency Range 5 Insertion Loss (RFC to RF1/RF2) 2500 MHz 0.15 dB 5MHz 0.20 dB 200MHz 0.30 0.45 dB 915MHz 0.35 0.50 dB 1980MHz 0.40 Isolation (RFC to RF1/RF2) 2200MHz 70 dB 50 dB 200MHz 36 dB 915MHz 28 dB 1980MHz 26 dB 2200MHz >70 dB 5MHz >70 dB 200MHz 48 dB 915MHz 34 dB 1980MHz 32 dB 2200MHz Return Loss (On-State) >15 dB Freq <1200MHz >13 dB 1200MHz < Freq < 2500MHz CSO >100 dBc 41dBmV/ch, 137 channels) CTB >100 dBc XMOD >90 Isolation (RF1 to RF2) Max Operational Input Power 5MHz dBc 30 dBm 5MHz to 25MHz, 75 load 33 dBm 25MHz to 500MHz, 75 load 36 dBm >500MHz, 75 load Power Supply Device Voltage, VDD 2.7 Leakage Current, IDD Control Voltage (EN, CTRL) Control Current Switching Speed (TON, TOFF) DS120601 1.3 3 4.6 V 100 200 A EN = High EN = Low 14 20 A 1.8 2.7 V 0 0.45 V 2.5 5 A 1 3 A CTRL = Low, EN = High 2 5 s 50% Control to 10/90% RF CTRL = High, EN = High 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 3 of 11 RFSW1012 Typical Performance: 50 Evaluation Board Insertion Loss versus Frequency Insertion Loss over Temperature (RFC-RF1) 0 -0.2 -0.2 -0.4 -0.4 -0.6 -0.6 Insertion Loss (dB) Insertion Loss (dB) 0 -0.8 -1 -1.2 -1.4 -0.8 -1 -1.2 -1.4 -1.6 RFC-RF1 -1.8 RFC-RF2 -40°C -1.8 -2 0 1 2 3 Frequency (GHz) 4 25°C -1.6 5 85°C -2 6 0 Return Loss versus Frequency (On-State) 2 3 Frequency (GHz) 4 25°C RFC -5 -5 RF1 -40°C 85°C RF2 -10 Return Loss (dB) Return Loss (dB) -10 -15 -15 -20 -20 -25 -25 -30 -30 0 1 2 3 Frequency (GHz) 4 5 0 6 Isolation versus Frequency -10 -20 -20 Isolation (dB) Isolation (dB) -10 -30 -40 1 2 3 Frequency (GHz) 4 5 6 Isolation over Temperature (RFC-RF1) 0 0 -30 -40 -50 -50 25°C RFC-RF1 -60 -40°C -60 RFC-RF2 85°C RF1-RF2 -70 -70 0 4 of 11 6 5 Return Loss over Temperature (RFC) 0 0 1 1 2 3 Frequency (GHz) 4 5 6 0 1 2 3 Frequency (GHz) 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 4 5 6 DS120601 RFSW1012 IP3 versus Frequency IP3 over Temperature (24dBm Tones, 1MHz Spacing) (24dBm Tones, 1MHz Spacing) 80 80 78 78 76 76 74 74 72 72 IP3 (dBm) IP3 (dBm) Typical Performance: 50 Evaluation Board 70 68 68 66 66 64 25°C 64 RF1 IP3 data is limited by the dynamic range of the test system. 62 RF2 -40°C IP3 data is limited by the dynamic range of the test system. 62 60 85°C 60 0.7 0.9 1.1 1.3 1.5 1.7 Frequency (GHz) 1.9 2.1 2.5 2.3 0.7 0.9 Insertion Loss versus Frequency and Power, 25°C 0 1.1 1.3 1.5 1.7 Frequency (GHz) 1.9 2.1 2.3 2.5 Insertion Loss versus Power over Temperature, 2500MHz 0 -0.1 -0.1 -0.2 -0.2 -0.3 -0.3 Insertion Loss (dBm) Insertin Loss (dBm) 70 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 5MHz 25MHz 500MHz 880MHz 2200MHz -0.4 -0.5 -0.6 -0.7 25°C -40°C 85°C -0.8 -0.9 2500MHz -1 -1 15 18 21 24 27 30 33 Input Power (dBm) 36 39 15 45 42 18 21 24 27 30 33 Input Power (dBm) 36 39 42 45 EVB THRU Performance, 25°C 0.0 0 This THRU insertion loss has been deembedded from the SW1012 plots and tabular data. -3 -0.2 -6 -0.3 -9 -0.4 -12 -0.5 -15 -0.6 -18 -0.7 Return Loss (dB) Insertion Loss (dB) -0.1 -21 IL -0.8 -24 RL -0.9 -27 -1.0 -30 0 DS120601 1 2 3 Frequency (GHz) 4 5 6 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 5 of 11 RFSW1012 Typical Performance: 75 Evaluation Board Insertion Loss versus Frequency Insertion Loss over Temperature (RFC-RF1) 0.0 -0.2 -0.2 -0.4 -0.4 -0.6 -0.6 Insertion Loss (dB) Insertion Loss (dB) 0.0 -0.8 -1.0 -1.2 -1.4 -0.8 -1.0 -1.2 -1.4 -1.6 RFC-RF1 -1.6 -1.8 RFC-RF2 -1.8 -40°C -2.0 0.0 0.5 1.0 1.5 Frequency (GHz) 2.0 25°C 85°C -2.0 2.5 0.0 Return Loss versus Frequency (On State) 0 0.5 1.0 1.5 Frequency (GHz) Return Loss over Temperature (RFC) RFC 25°C RF1 -5 -40°C RF2 85°C Return Loss (dB) Return Loss (dB) -10 -15 -10 -15 -20 -20 -25 -25 -30 -30 0.0 0.5 1.0 1.5 Frequency (GHz) 2.0 0.0 2.5 Isolation versus Frequency 0 -10 -10 -20 -20 -30 -40 0.5 1.0 1.5 Frequency (GHz) 2.0 2.5 Isolation versus Temperature (RFC-RF1) 0 Isolation (dB) Isolation (dB) 2.5 0 -5 -30 -40 -50 -50 25°C RFC-RF1 85°C -60 RFC-RF2 -60 -40°C RF1-RF2 -70 -70 0.0 6 of 11 2.0 0.5 1.0 1.5 Frequency (GHz) 2.0 2.5 0.0 0.5 1.0 1.5 Frequency (GHz) 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 2.0 2.5 DS120601 RFSW1012 Typical Performance: 75 Evaluation Board CTB versus Temperature CSO Upper versus Frequency (3V, 137 Ch., 41dBmV) 115 115 110 110 105 105 CSO Upper (dBc) CTB (dBc) (3V, 137 Ch., 41dBmV) 100 95 100 95 25°C 25°C -40°C 90 -40°C 90 85°C 85°C 85 85 0.0 0.1 0.2 0.3 0.4 0.5 0.6 Frequency (GHz) 0.7 0.8 0.9 1.0 0 0.1 CSO Lower versus Frequency 0.2 0.3 0.4 0.5 0.6 Frequency (GHz) 0.7 0.8 0.9 1 EVB THRU Performance, 25°C (3V, 137 Ch., 41dBmV) 0 0.0 115 -3 -0.2 IL -6 -0.4 110 RL Insertion Loss (dB) CSO Lower (dBc) 105 100 95 25°C This THRU insertion loss has been deembedded from the SW1012 plots and tabular data. -0.8 -12 -1.0 -15 -1.2 -18 -1.4 -21 -1.6 -24 -1.8 -27 Return Loss (dB) -9 -0.6 -40°C 90 85°C -30 -2.0 85 0 DS120601 0.1 0.2 0.3 0.4 0.5 0.6 Frequency (GHz) 0.7 0.8 0.9 1 0.0 0.5 1.0 1.5 Frequency (GHz) 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 2.0 2.5 7 of 11 RFSW1012 Evaluation Board Schematic Evaluation Board Bill of Materials (BOM) Description Reference Designator Manufacturer Manufacturer’s P/N C1 Murata Electronics GRM155R71E103KA01D 50Ω PCB, SW1012-411 SW1012-411(A) CAP, 10000pF, 10%, 25V, X7R, 0402 CAP, 100pF, 5%, 50V, C0G, 0402 C2-C3 Taiyo Yuden (USA), Inc. RM UMK105CG101JV-F CONN, SMA, END LNCH, MINI, FLT, 0.068" J1-J3 Emerson Network Power 142-0741-851 CONN, HDR, ST, PLRZD, 5-PIN, 0.100" P1 ITW Pancon MPSS100-5-C SPDT MMIC Switch U1 RFMD For 75Ω applications use the following PCB and RF connector: 75Ω PCB, SW1012-410 SW1012-410(A) CONN, F, FEM EDGE MOUNT, 75Ω, 0.068" 8 of 11 J1- J3 Millimeter Wave Technologies 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD MW-846-C-DD-75 DS120601 RFSW1012 50Evaluation Board Assembly Drawing 75Evaluation Board Assembly Drawing DS120601 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 9 of 11 RFSW1012 Control Logic for Valid Operational States State VDD CTRL EN RF Path 1 2.7V to 4.6V 2.7V to 4.6V Shutdown 2.7V to 4.6V Don’t Care VHIGH VHIGH VLOW ANT-RF2 2 VHIGH VLOW ANT-RF1 Shutdown Pin Names and Descriptions Pin 1 2 3 4 5 6 7 8 9 10 11 12 EPAD Name GND RFC GND GND RF1 GND CTRL EN VDD GND RF2 GND GND Description No-connect internal, recommend GND at the EVB level. Single-ended RF port. No-connect internal, recommend GND at the EVB level. Ground. Single-ended RF port. Ground. Switch logic control input. Shutdown logic control input. Supply voltage. Ground. Single-ended RF port. Ground. Ground. Must be soldered to EVB GND over one or more vias. Pin Out 10 of 11 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD DS120601 RFSW1012 Package Drawing and Branding Diagram (Dimensions in millimeters) DS120601 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or [email protected]. www.BDTIC.com/RFMD 11 of 11