ROI for Energy Saving Initiatives Zahl Limbuwala 21
ROI for Energy Saving Initiatives Zahl Limbuwala – Chairman DCSG / CEO Romonet Ltd 21st June 2010 Overview • The Carbon Context • The Reality - Demands & Constraints • Metrics & Harmonisation • What really matters? • BCS Software Demo - Quantifying Return on Investment Presentation to insert name here 2 Context Presentation to insert name here 3 The Reality Constraints Requirement for Granularity of Carbon Footprint Measurement Demands Power Availability Rising Power Consumption of IT Devices Power Cost Carbon Cost (Offset, Cap &Trade) Data Centre Operators Brand Value (CSR) Rising Demand for IT Services Business Continuity Regulation Requirement for Improved Efficiency Presentation to insert name here 4 Metrics & Harmonisation Presentation to insert name here 5 Productivity Proxies RER PUE / DCIE DCEP • PUE – Power Usage Effectiveness • DCIE – Data Center Infrastructure Efficiency • RER – Reuse Energy Ratio • DPPE – Data Centre Performance Per Energy • DCEP – Data Centre Energy Productivity DPPE Metrics Presentation to insert name here 6 What really matters? $ € ¥ Cost Efficiency = Energy Efficiency = Carbon Efficiency kWh - CO2 Presentation to insert name here 7 Data Centre Model Server Workloads Proportion IT Workload 0 20 40 60 80 100 Percent Load Server Power Utilisation by Load 500 Watts 400 300 200 100 0 0% 20% 40% 60% 80% 100% IT Device Load to Power Function Load Input Power kW Data Centre Power Transfer Functions 1,800 1,600 1,400 1,200 1,000 800 600 400 200 0 0 200 400 600 IT Electrical Load (kW) 800 1,000 Data Centre Power Transfer Function Presentation to insert name here 8 Energy Cost CRAC Load Location Air Flow Data Centre Layout Carbon Intensity Energy Use Power Cost Chiller Climate CRACs Air Flow UPS PDUs IT Device Application Workload Variation Source of Energy Everything Else Time Climate Time Total Thermal Losses Total Thermal Losses Electrical Load Electrical Load Workload Time What is simulation? BCS Simulator Understands Variability Data Centre Metrics 9 Logical Layout Presentation to insert name here 10 Understanding DCIE/PUE Presentation to insert name here 11 Data Centre Simulation What is Simulation? Scenario 1 – Large FS data centre Results Analysis Scenario 2 – Small office building data centre Results Analysis Data Centre Metrics 12 Scenario 1 Base Scenario • 3.5 MW design IT capacity • 2N+1 Infrastructure • Running at 90% of rated capacity • Using the old ASHRAE spec (45-55% RH) • Poor airflow management • No power management • No virtualisation Data Centre Metrics 13 Scenario 1 Base Scenario • Located in London • Chilled water / Dry cooler design • Power cost of 8p/kWh rising to 10.5p/kWh • Carbon intensity of 0.573kg / kWh Data Centre Metrics 14 Scenario 1 – Implement EU CoC Implement EU Code of Conduct Best Practices • Airflow management (aisle containment) • Variable Speed Drives in the CRAC units • New ASHRAE spec • Enable power management on servers Data Centre Metrics 15 Scenario 1 – Implement Economiser Implement Economiser • Airflow management (aisle containment) • Variable Speed Drives in the CRAC units • New ASHRAE spec • Enable power management on servers • Implement an indirect waterside economiser Data Centre Metrics 16 Scenario 1 Comparison 4-Year Cost / Energy / Carbon Analysis Scenario Energy (GWh) Carbon (Tons) Energy Cost Base 231 122,000 $43.4m Implement EU CoC 168 89,000 $31.6m EU CoC + Economiser 147 78,000 $30.2m Savings 84 44,000 $12.7m Data Centre Metrics 17 Scenario 2 Base Scenario • 100 kW design IT capacity • N+1(cooling) N (power) Infrastructure • Running at 60% of rated capacity • Wall mounted DX units (no humidity control) • Poor airflow management (open racks) • 100 Dell servers (2007 vintage) (2U) • No power management • No virtualisation (5%-10% utilised) Data Centre Metrics 18 Scenario 2 Base Scenario • Located in an office in London (shared Transformer) • Power cost of 8p/kWh rising to 10.5p/kWh • Carbon intensity of 0.573kg / kWh Data Centre Metrics 19 Scenario 2 – Virtualisation Programme Virtualisation Programme • Replace old Dell servers – 2009 Energy Star 2U Dell • Reduce from 100 to 10 servers • Enable power management Data Centre Metrics 20 Scenario 2 Comparison Virtualisation Programme Analysis Scenario Energy (GWh) Carbon (Tons) Energy Cost Base 3 1650 $583k Virtualisation Programme 1.8 978 $348k Savings 1.2 672 $235k Data Centre Metrics 21 Summary Data Centre Simulator – Free for BCS members Simulator core code is open source Thank You Zahl Limbuwala [email protected] Data Centre Metrics 22