DESIGN CRITERIA: HIGHMAST LIGHTING NOTES:
HIGHMAST LIGHTING NOTES: DESIGN CRITERIA: 1. 1. Designed in accordance with the FDOT Structures Manual. 2. Poles are designed to support the following: High Mast materials: a. Pole: ASTM A1011 Grade 50, 55, 60 or 65 (Less than …") or ASTM A572 Grade 50, 55, 60, or 65 (…" and over) or ASTM A595 Grade A (55 ksi yield) or Grade B (60 ksi yield). a. (1) cylindrical head assembly with a maximum effective projected b. (8) cylindrical luminaires with a maximum effective projected area area of 6 SF (Cd=1) and 340 lbs (Max). b. Steel Plates: ASTM A709 Grade 36 or ASTM A36 of 3.0 SF (Cd=0.5) and 77 lbs. each. c. Weld Metal: E70XX 3. d. Anchor Bolts: ASTM F1554 Grade 55 with ASTM A563, Grade A heavy-hex nuts and plate washer. Foundation design based upon the following soil criteria: Classification = Cohesionless (Fine Sand) Friction Angle = 30 Degrees (30) Unit Weight = 50 pcf (assumed saturated) e. Handhole: ASTM A709 Grade 36 or ASTM A36 Frame with ASTM A36 cover. Only in cases where the Designer considers the soil types at the f. Caps: ASTM A1011 Grade 50, 55, 60 or 65 or ASTM B209. specific site location to be of lesser strength properties should an analysis be required. Auger borings, SPT borings or CPT soundings may g. Nut Covers: ASTM B26 (319-F) be utilized as needed to verify the assumed soil properties, and at relatively uniform sites, a single boring or sounding may cover several h. Stainless Steel Screws:AISI Type 316 foundations. Furthermore, borings in the area that were performed for other purposes may be used to confirm the assumed soil properties. 2. Reinforcing steel: ASTM A615, Grade 60. 3. Concrete: Class IV (Drilled Shaft) with a minimum 4,000 psi compressive strength at 4. Foundation applies only to slopes of 1:4 or flatter. Provide a minimum 5. Poles are designed for 6 mil galvanization thickness. 24" shaft projection on the high side. 28 days for all environmental classifications. 4. Welding: American Welding Society Structural Welding Code (Steel) ANSI/AWS DI.1 Current edition). 5. Galvanization: a. Nuts, Bolts, Washers and Threaded Bars/Studs: ASTM F2329. b. Other items (Including Pole): ASTM A123 6. Hole diameters for anchor bolts: not greater than the bolt diameter plus ‰". 7. Poles: Tapered with the diameter changing at a rate of 0.14 inch per foot with a minimum 16-sided pole shaft and maximum of two longitudinal seam welds. Circumferentially welded pole shaft butt splices and laminated pole shafts are not permitted. Longitudinal seam welds within 6 inches of pole to base must be complete penetration welds. Longitudinal seam welds at telescopic field joints must be complete penetration welds for the splice length plus 6 inches. C: \d\projects\standards\roadway\17500-s\17502-01. dgn 8. One hundred percent of full-penetration groove welds and a random 25 percent of partial penetration groove welds shall be inspected. Full-penetration groove weld inspection shall be performed by nondestructive methods of radiography or ultrasonics. 9. Furnish each pole with a 2"x4" (Max.) aluminum identification tag. Submit details for approval. Secure to pole with 0.124" stainless steel rivets or screws. Locate identification tag on the inside of pole and visible from handhole. Include the following information: Financial Project ID, Pole Mounting Height, Manufacturer’s Name, Fy of Steel, and Base Wall Thickness. 10. Verify CSL access tubes will not interfere with anchor bolt installation before excavating the shaft. When CSL access tube locations conflict with anchor bolt locations, move the CSL access tube location – two inches along the inner circumference of the reinforcing cage. Notify the Engineer before excavating the shaft if the CSL access tube locations cannot be moved out of conflict with anchor bolt 12/30/2011 11: 49: 02 AM rd960rh locations. LAST REVISION 01/01/12 REVISIO N STANDARD POLE DESIGN NOTES DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 1 Luminaire Head Luminaires Length Section ( 1) Pole Design Table* Section 1 (Top) Design Wind Speed Joints Splice Length ( 1) Telescopic Field (8 Maximum) 110 mph Round or 16-Sided Pole (Faces not shown for clarity) (see Note 9) Handhole Door Section 3 Minimum Minimum Minimum Tip Dia. Base Dia. Length WallTh. Tip Dia. Base Dia. Length WallTh. Tip Dia. Base Dia. Splice L. Splice L. Splice L. 80 42’-0" 0.250" 2’-0" 5.313" 11.219" 40’-0" 0.250" --- 100 24’-6" 0.179" 2’-0" 120 44’-9" 0.250" 2’-0" 10.375" 16.000" --- --- --- --- --- 6.406" 9.844" 40’-0" 0.250" 6.250" 12.531" 40’-0" 0.250" 2’-6" 9.188" 14.781" 40’-0" 0.250" --- 13.875" 19.500" 2’-9" 11.688" 17.313" 40’-0" 0.313" --- 16.375" 22.000" 80 42’-0" 0.250" 2’-0" 5.281" 11.188" 40’-0" 0.313" --- 10.375" 16.000" --- --- --- --- --- 100 24’-6" 0.179" 2’-0" 6.906" 10.344" 40’-0" 0.250" 2’-6" 9.656" 15.281" 40’-0" 0.313" --- 14.375" 20.000" 120 45’-6" 0.250" 2’-6" 9.250" 15.625" 40’-0" 0.250" 3’-0" 14.719" 20.344" 40’-0" 0.313" --- 19.375" 25.000" 80 42’-3" 0.250" 2’-3" 7.281" 13.219" 40’-0" 0.313" --- 12.375" 18.000" --- --- --- --- --- 100 24’-6" 0.250" 2’-0" 8.188" 11.625" 40’-0" 0.313" 2’-6" 10.781" 16.406" 40’-0" 0.375" --- 15.375" 21.000" 120 46’-6" 0.250" 3’-0" 12.406" 18.938" 40’-0" 0.313" 3’-6" 17.938" 23.563" 40’-0" 0.375" --- 22.375" 28.000" * Diameter Measured Flat to Flat Joints Splice Length ( 2) Length Section ( n) Identification Tag 150 mph Length WallTh. Section 2 Base Plate and Bolts Design Table Telescopic Field C: \d\projects\standards\roadway\17500-s\17502-02. dgn 0. 14 in/ft Taper, Typ. Length Section ( 2) Overall H eight 130 mph Pole Overall Height (ft) Design Wind Speed Pole Overall Height (ft) Base Plate Diameter Base Plate Thickness Bolt Circle No. Bolts Bolt Diameter Bolt Embedment 80 30.0" 2.500" 23.0" 8 1.75" 38" 110 mph 100 33.5" 2.500" 26.5" 8 1.75" 42" 120 36.0" 2.750" 29.0" 8 1.75" 45" 130 mph 150 mph Base Plate Shaft Design Table 80 30.0" 2.500" 23.0" 8 1.75" 43" 100 34.0" 2.750" 27.0" 8 1.75" 50" 120 41.0" 3.250" 33.0" 8 2.00" 52" 80 32.0" 2.750" 25.0" 8 1.75" 49" 100 37.0" 3.000" 29.0" 8 2.00" 53" 120 46.0" 3.250" 37.0" 10 2.25" 57" Design Wind Speed Pole Overall Height (ft) 80 110 mph 100 130 mph 150 mph Shaft Diameter Shaft Length Longitudinal Reinforcement 4’-0" 13’-0" 14 - # 11 4’-0" 15’-0" 14 - # 11 120 4’-6" 16’-0" 16 - # 11 14 - # 11 80 4’-0" 14’-0" 100 4’-0" 16’-0" 14 - # 11 120 4’-6" 18’-0" 16 - # 11 80 4’-0" 16’-0" 14 - # 11 100 4’-6" 17’-0" 16 - # 11 120 5’-0" 20’-0" 18 - # 11 rd960rh Wire screen 2’-0" Min. to highmasts on Fill Fill H eight Line adjacent 25’M axim um Natural Ground 12/30/2011 11: 49: 03 AM 4 (Max. Slope) 1 Drilled Shaft LAST REVISION 01/01/09 REVISIO N ELEVATION POLE DESIGN TABLES DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 2 10" 11" Shaft Diameter Base Plate 4" p a "L 2 ’ 2 ) . n Mi ( Diameter Handhole Ring Bolt Circle 1 2" Center of x 6" Ring 1 4" #5 Tie Bars Drilled Shaft Thick Handhole Door Padlock Tab CSL tube (Typ.) 1 4" 1 1’ -9" C 10" C 1’ -8" Full Pen. Padlock Tab 6" B B Hinge Mount (Typ.) Edge of Equally Spaced. Base Plate Longitudinal Reinforcement Eq. Spaced (See Table For Reinforcement) (See Table) Center of Drilled Base Partial Penetration 6" Cover Joint (Typ.) " " 3 4 = R Diameter (Pole) Shaft, Base 4" Anchor Bolts 3 4 2 Full Pen. = R 2 Plate, and Pole FOUNDATION PLAN (T = Wall Thickness) SECTION A-A HANDHOLE RING (Anchor Bolts and Conduits Not Shown) HANDHOLE DOOR 2 X Bolt Diameter …" »¿Wall Thk. + 45 deg. x Wall Thk. Bolt Circle Anchor Bolts Base Plate Shaft Diameter Double Nuts, Top Nut may be half Diameter Nut Cover (not shown) for each bolt 1 4" 1 1’ -8" Base Plate ( Top) 4" Cover …" 6 Sp. @ Ring C: \d\projects\standards\roadway\17500-s\17502-03. dgn 1" Min. 4" Handhole Silicone Caulk Plate Washer 5" E M in. 2’ -0" 3 8" E »¿3"X ˘" Backing height ’Jam’ Nut. Provide individual 1" x 1" Chamfer Base Plate Thickness Opening (1) Bolt Diameter Handhole (Max.) Door Anchor Bolt A A Drilled Shaft Leveling Wire screen Finished Grade 1: 4 Max Slope Tip Diameters or Base Diameters measured flat to flat SECTION C-C Center of Arm Sp. @ M in. Bolt Em bedm ent 2’ -0" see Spec. 649-6 1’ -6" ( M ax. ) 12" Base Diameter rd960rh Shaft Length Nuts Inside Radius Double Nuts (Typ.) Wall measure center Thickness to flat Typ. (see Note) 12/30/2011 BASE PLATE AND ANCHORAGE ELEVATION (Conduits Not Shown) Break Radius Typical Spacing Drilled Shaft # 5 Ties 11: 49: 04 AM 1" 7" 0.6 x Wall Thickness 6" Cover NOTE: Min. Break Radius Longitudinal seam welds within six inches of = 0.25 x (Inside circumferential welds shall be complete penetration Radius) welds. Longitudinal seam welds at telescopic field splices shall be complete penetration welds for (Typ.) the splice length plus six inches. SECTION B-B (Conduits Not Shown) SECTION E-E LAST REVISION 07/01/10 REVISIO N POLE FOUNDATION DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 3 Twistlock disconnect Schedule 40 PVC conduit. Circuit conductors and conduit size as shown In plans. (Typical). Schedule 40 PVC conduit with 4/0 Cu Pigtail Cord W/Female Receptacle bare ground wire. Male Inlet Circuit Breaker Panel Box with Surge Interrod distances must Arrester mounted to Top of Circuit Breaker be a minimum of 10’. Panel Box for easy access. Service entrance fittings shall be used on all conductors entering Circuit Breaker Panel Box. Attach Copper Lugs (Two-Hole, Straight Tongue, Two-Barrel) to winch support plate to #6 ground accommodate 2-4/0 and 2-#6 conductors for grounding. 4/0 ground Schedule 80 PVC conduit Wire Screen see Spec. 649-6 2’ 4/0 AWG stranded C: \d\projects\standards\roadway\17500-s\17502-04. dgn CU bare ground wire connected to grounding lug inside pole. #6 Bonding Ground expansion 2’ -6" 3 8" joint (sealed) 12" bed of pearock or crushed stone for drainage. U L approved ground rod 5 8" diameter 20’ long copper clad with approved ground connection. 4/0 Cu bare ground wire connected to Minimum of (6) 5 8" x 20’ rd960rh approved ground rods. Schedule 40 grounding field PVC conduit or array. with 4/0 Cu bare ground Schedule 40 PVC conduit. Circuit conductors 11: 49: 04 AM wire. and conduit size as shown in plans. (Typical). NOTES: 1. At all pull boxes and pole bases, ends of conduit shall be sealed in accordance with Section 630 of the 12/30/2011 Standard Specifications For Road And Bridge Construction. 2. Slabs to be placed around all Poles and Pull Boxes. 3. For Pull Boxes between Poles refer to Index 17500. LAST REVISION 01/01/12 REVISIO N WIRING DETAILS DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 4 To The contractor’s attention is directed to those plan Luminaire sheets detailing the mounting of luminaires at the pole top. Particular attention is directed to Ground to Winch alignment of luminaire light distributions. Special Cover attention must be exercised in the physical alignment Support Plate of these luminaires to ensure that the approved photometric layout is physically produced at each Circuit Panel Equipment lighting standard in the field. A marking shall be SPD Ground Conductor placed on the external face of the refractor to Breaker allow visual inspection of alignment. The marking shall correspond to the 0 axis of the refractor. Head plate See legend for number 4/0 Ground of luminaires, lamp wattage and light distribution. Lift cable sheaves Conduit Luminaire support ring Grounding Array 480V Phase #6 Bonding Ground to Phase Lift cables (2 minimum) Pole cable 20’ Ground & sheaves Pull Box Rod 2" slip fitter Cover HI GH MAST POL E WI RI NG DI AGRAM Lift cables Power Cable Terminator 600 Volt rated Pole Cable. Luminaires Size of conductors to be determined by luminaire load. All hardware for mounting heavy duty drill to pole shall be Stainless Steel. Male Inlet 1 2" C: \d\projects\standards\roadway\17500-s\17502-05. dgn 2" Slip-fitter Assembly Slip clutch Step-down transformer provided with (equally spaced around ring) 120V. grounded receptacle for electric drill & receptacle for supply cable. Power Cord (see schematic) With Male Inlet 25’ minimum remote control cable same as Pole Cable. ON OFF Remote control switch Covered receptacle to power luminaires when in the lowered Receptacle position with Male Inlet. Pole Cable High mast pole Winch cable off on Female Plug Circuit Breaker Cable rd960rh heavy duty reversible or 1 HP Portable Motor(1) per project. Luminaire support ring with Female Plug gnd. Remote control switch Positive drive reversible winch 11: 49: 05 AM Hand hole Winch Supply cable receptacle Lock nuts A surge protector shall 600 Volt rated Circuit Breaker Cable. be located in the pole with the circuit breaker. The surge Size of conductors to be determined SCHEMATI C OF REMOTE AUXI L I ARY POWER UNI T by luminaire load. protector shall be mounted 12/30/2011 at the front near hand hole for easy access. LAST REVISION 01/01/12 REVISIO N Base plate Base plate LOWERING DETAILS DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 5 10’-0" 2’-0" Varies Varies NOTES: 1. Use compacted select material in accordance with Index 505. 2. Concrete shall be Class NS with a minimum strength at 28 days of f’c=2.5 ksi. 3. Outside edge of slab shall be cast against formwork. 4. The pull box shown is 13" x 24"; others approved under 10’ -0" Pull Box Slabs to be placed around all Poles and Pull Boxes. In urban areas or where space is limited slab dimensions may be adjusted as shown in the plans. 6. 12" C Section 635 of the Standard Specifications may be used. 5. 13" Typ. C Concrete for slabs around poles and pull boxes shall be included 7. The 1 2" 1 2" thick expansion joint between the pole shaft and slab shall 5’ in the price of pole or pull box. Expansion Joint (Sealed) be sealed with a hot poured elastic joint sealer. C: \d\projects\standards\roadway\17500-s\17502-06. dgn SLAB DIMENSIONS 1 2" Expansion Joint (Sealed) SHAFT LOCATION 6" L BOX PUL ON OCATI L 6" rd960rh 4" SELECT MATERIAL 12/30/2011 11: 49: 06 AM SECTION C-C REVISION 01/01/12 REVISIO N SLAB DETAILS LAST DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 HIGHMAST LIGHTING NO. 17502 SHEET NO. 6