Comments
Description
Transcript
FDOT DESIGN STANDARDS 2013 ~
Deck Expansion Joint Front Face of Backwall Deck Expansion Joint Bridge Deck Approach Slab & Begin or End Bridge Deck Guardrail Transition Section when called for in Plans ~ Bridge in Railing * Gutter Line ~ ~ ~ Traffic Railing * ~ " Open Joint Gutter Line 2" PVC 2" PVC Conduits See Detail "A" or "B" as Coping Coping required by Structures Plans required by Structures Plans See Detail "C" ( M in. ) Pull Box "A" ** See Detail "A" or "B" as 1’ -0" Conduits 6’-0" Min. to Railing Ends & 2" Max. Pull Box Spacing all Open joints in Railings (Typ.) PARTIAL PLAN VIEW ALONG BRIDGE Deck Expansion Joint 2" (See Note 7) End Bent Wing M ax. Steel Pipe, 300’-0" (Max.) Guardrail Post PARTIAL PLAN VIEW ALONG APPROACH SLAB WITHOUT CONTINUING TRAFFIC RAILING Deck Expansion Joint Traffic Railing * Traffic Railing * Guardrail Transition Section when called for in Plans " Open Joint Pull Box "A" ** 2" PVC in Railing * Conduits See Detail "A" ~ ~ or "B" as required 2’ -0" ( M in. ) Top of Coping See Detail "C" Approach Slab by Structures Plans Top of Coping Bridge Deck Front Face of Backwall by Structures Plans & Begin or End Bridge 2" PVC ~ or "B" as required End Bent Wing PARTIAL ELEVATION VIEW ALONG BRIDGE Conduits ~ See Detail "A" PARTIAL ELEVATION VIEW ALONG APPROACH SLAB WITHOUT CONTINUING TRAFFIC RAILING ** Pull Box "A" shown, Pull " Open Joint at Begin " Open Joint in Retaining C: \d\projects\standards\structures\2013book\21210-1of2. dgn or End Approach Slab Wall Coping & Traffic Railing * Traffic Railing * Wall Coping only Gutter Line " Open Joint in Retaining Guardrail Transition Section Box "B" similar. See Pull when called for in Plans Box "B" Detail, (Sheet 2). Traffic Railing * Pull Box "A" ** Begin or End of 2" PVC Conduits 2" PVC Conduits Retaining Wall Steel Pipe, See Detail "A" Retaining Wall Coping See Detail "C" Retaining Wall Coping PARTIAL PLAN VIEW ALONG APPROACH SLAB " Open Joint in Retaining Traffic Railing * or End Approach Slab Traffic Railing * Wall Coping & Traffic Railing * 6’-0" (Min.) 300’-0" (Max.) 2" PARTIAL PLAN VIEW ALONG RETAINING WALL WITH CONTINUING TRAFFIC RAILING " Open Joint at Begin 2" Max. M ax. Retaining Wall Coping ( M in. ) See Detail "B" Approach Slab 1’ -0" (See Note 7) * 32" F Shape Traffic Pull Box Spacing Railing shown, other 2" PVC Pull Box "A" ** 2" PVC Conduits Conduits Traffic Railings and Pedestrian / Bicycle Railing similar See Detail "B" Top of Coping See Detail "A" " Open Joint in Retaining Guardrail Transition Section Top of Coping Wall Coping only 2" PVC ~ 1: 08: 28 PM Retaining Wall Coping ~ ~ Approach Slab when called for in Plans ~ 2’ -0" ( M in. ) rd960rh Shoulder Line ~ Conduits Retaining Wall Panels (Typ.) Retaining Wall Coping See Detail "C" WITH CONTINUING TRAFFIC RAILING PARTIAL ELEVATION VIEW ALONG RETAINING WALL (Retaining Wall Mounted Traffic Railing shown, Roadway Concrete Barrier similar) LAST REVISION 01/01/12 REVISIO N 6/28/2012 PARTIAL ELEVATION VIEW ALONG APPROACH SLAB DESCRIPTION: INDEX FDOT DESIGN STANDARDS 2013 CONDUIT DETAILS NO. 21210 SHEET NO. 1 Traffic Railing Provide 2 supplemental #5 Bars (32" F Shape) each 10’-0" long centered about CONDUIT GENERAL NOTES: Traffic Railing Provide 3 supplemental (42" Vertical Pull Box #5 Bars each 10’-0" long Shape) 1. Furnish and install approved Conduits and Fittings in accordance with the Specifications, this Standard, and the National Electric Code (NEC) and as directed by the Engineer. centered about Pull Box Pedestrian/Bicycle Pull Box "A" (Double Conduit) 2. Furnish Schedule 80 PVC Rigid Nonmetallic Conduits in accordance with NEMA TC-2 and UL Railing Standard 651. Furnish Fittings in accordance with NEMA TC-3 and UL Standard 514b. Conduit (1’-6" Max. x 1’-6" Max. and Fittings must have UL labels: Conduit on each 10-foot length; Fittings stamped or molded x 8" Max.) Pull Box "A" (Double Conduit) 2 ~ 2" PVC Conduits 2 ~ 2" PVC (1’-6" Max. x 1’-6" Max. Conduits x 6" Max.) Pull Box "A" (Double Conduit) (1’-6" Max. x 2 ~ 2" PVC on each Fitting. Connect Conduit and Fittings using solvent cement in accordance with the manufacturers recommendations. 1’-6" Max. x 8" Max.) 3. Furnish and install Pull Boxes sized in accordance with NEC requirements and the maximum Conduits size limits shown. For locations where the superstructure environment is classified as slightly or moderately aggressive, furnish Galvanized Steel or NEMA Type 4X Pull Boxes. Where the superstructure environment is classified as extremely aggressive, furnish NEMA Type 4X Bridge Deck or Bridge Deck or Approach Slab Approach Slab non-metallic Pull Boxes. All Pull Boxes shall include weatherproof covers with gaskets. Permanently indicate the utility within the Pull Box by stamping or molding the information using letters and symbols that are a minimum of ‰ high. Install Pull Boxes adjacent to the Begin and SECTION THRU TRAFFIC RAILING End of Bridges, Begin and End of Retaining Walls, and at other required locations. Omit Pull SECTION THRU PEDESTRIAN / BICYCLE AT PULL BOX RAILING AT PULL BOX Bridge Deck or Approach Slab with Raised Sidewalk (32" F SHAPE SHOWN, Soil Concrete traffic face of Traffic Railings. 6" ( M ax. ) 3" ( M in. ) 42" F SHAPE SIMILAR) SECTION THRU TRAFFIC RAILING AT PULL BOX (42" VERTICAL SHAPE SHOWN, 32" VERTICAL SHAPE SIMILAR) 4. Furnish and install Expansion Fittings at locations shown in the Plans. Certify that Expansion Fittings used at a given location are rated to accommodate the anticipated movement at that location: along Bridge decks see Structures Plans, Expansion Joint Data Table; along Retaining Walls and other unspecified locations 2 minimum. 5. Furnish and install Expansion/Deflection Fittings at locations shown in the Plans. Certify that Wrap with sponge rubber 1 2" Expansion/Deflection Fittings used at a given location are rated to accommodate a minimum rotation of 30 degrees and the anticipated movement at that location: along Bridge decks- see thick nominal Structures Plans, Expansion Joint Data Table; along Retaining Walls and other unspecified Expansion / Deflection 2" PVC Conduits locations 0.7 minimum. Fitting DETAIL "C" EXPANSION / DEFLECTION 6. For all Conduit designated for future use, install, and leave in place, #12 AWG Pull Wire along the entire length of Conduit or #12 AWG Pull Wire on each End (from Traffic Railing Pull Box to FITTING DETAIL (CONCRETE / SOIL) Traffic Railing or Railing Pull Boxes in accordance with Section 630. Pedestrian / Bicycle Railing thick nominal 7. Stub out and cap the Conduit, and drive a steel pipe at the End of the Conduit as shown in this ~ 1 4" in-ground Pull Box or capped End) of the Conduit with a polypropylene cord between Bridge Traffic Railing Joint Wrap with sponge rubber Railing Joint 2" PVC ~ Standard. If required in the plans or by the Engineer, furnish and install in-ground Pull Boxes Conduits in accordance with Index 17700. Show location of stub out with Steel Pipe or in-ground Pull Box on As-Built plans. 8. Shift vertical Railing reinforcement symmetrically to provide 2 clearance to Pull Boxes. Space shifted vertical reinforcement at 3 centers minimum. Cut horizontal Railing reinforcement to provide 2 clearance to Pull Boxes and provide supplemental reinforcement as shown. Shift a ~ maximum of 1 but do not cut Railing reinforcement to facilitate Conduit, Expansion Fitting and Expansion/Deflection Fitting placement. Do not bundle Conduits, or Conduits and horizontal Wrap with sponge rubber Traffic Railing or Pedestrian / Bicycle Railing Expansion Fitting 1 4" reinforcement. thick nominal Expansion / Deflection Fitting DETAIL "A" DETAIL "B" EXPANSION / DEFLECTION EXPANSION FITTING DETAIL FITTING DETAIL (CONCRETE / CONCRETE) Traffic Railing 9. Unless otherwise shown in the plans, include the cost of furnishing and installing Conduit, Pull Cords and Wires, Pull Boxes, Expansion and Expansion/Deflection Fittings and all associated hardware required to complete the installation in the cost of the Traffic Railing or Pedestrian Railing (Parapet) that the Conduit is installed in. Deck Expansion Joint or Pull Box "B" (Single Conduit) (1’-6" Max. x 8" Max. x 8" Max.) Traffic Railing 2 ~ 2" PVC (1’-6" Max. x 8" Max. x 6" Max.) Parapet Conduits 3 4" Open Joint in Railing 1: 08: 31 PM rd960rh C: \d\projects\standards\structures\2013book\21210-2of2. dgn Boxes at Begin or End of Retaining Walls adjacent to Bridges unless a precast Traffic Railing with junction slab is used. Position Pull Boxes as shown; do not place Pull Box openings on the Top of Coping 6/28/2012 300’-0" (Max.) 8’-0" (Min.) 6’-0" (Min.) Pull Box Spacing LAST REVISION 07/01/12 REVISIO N PULL BOX "B" DETAIL DESCRIPTION: INDEX FDOT DESIGN STANDARDS 2013 CONDUIT DETAILS NO. 21210 SHEET NO. 2