HORIZONTAL WALL REINFORCING SCHEDULES (TABLE 1) SCHEDULES (TABLE 2)
by user
Comments
Transcript
HORIZONTAL WALL REINFORCING SCHEDULES (TABLE 1) SCHEDULES (TABLE 2)
4’-4" C-I-P 5’-1" Precast C-I-P 3’-0" Precast 8" 5’-5" C-I-P 3’-4" C-I-P 6" 4’-0" Precast 6" 8" 214" 8" C-I-P 3’-0" 6" Precast 1 4" 2 2 4’ -6" Precast 3’-0" 6" 4’ -6" 6" 1 4" 6" 8" 214" 1 4" Center Of Box Location Reference 8" 6" 6" 8" 2 C-I-P Center Of Box Precast Location Reference 6" 1 4" 2 4’-1" C-I-P 5’ -6" Precast Precast 6" 8" 5’ -10" C-I-P 6" 4’-1" 3’ -1" 2’-0" 8" 3’ -1" 6" 4’ -1" Precast C-I-P 4’ -5" C-I-P 8" 3’ -1" 2’-0" 3’ -1" 8" 8" 4’ -5" C-I-P 4’ -1" Precast 8" Precast Center Of Box C-I-P Location Reference Precast PLAN PLAN PLAN 5’-5" C-I-P SECTION #4 Bars Precast 2" Eyebolts See Index 201 Horiz. Wall Reinf. (See Table 3) 3" Cl. #4 Bars @ 12" Ctrs. C-I-P #4 Bars @ 10" Ctrs. #4 Bars Precast Precast @ 12" Ctrs. (Short Bars) @ 11" Ctrs. SECTION SECTION HORIZONTAL WALL REINFORCING HORIZONTAL WALL REINFORCING SCHEDULES (TABLE 1) SCHEDULES (TABLE 2) SCHEDULES (TABLE 3) WALL 0’-15’ SCHEDULE A12 AREA MAX. SPACING (in.†/ft.) BARS WWF 0.20 12" 8" TYPE C WALL DEPTH 2’-0" Wall - 18" Pipe AREA SCHEDULE MAX. SPACING (in.†/ft.) BARS WWF WALL DEPTH SCHEDULE AREA MAX. SPACING (in.†/ft.) BARS WWF 0’-6’ A12 0.20 12" 8" 0’-5’ A12 0.20 12" 8" 6’-10’ A6 0.20 6" 5" 0’-7.5’ A6 0.20 6" 5" 10’-13’ A4 0.20 4" 3" 7.5’-10’ B5.5 0.24 5 10’-15’ B5.5 0.24 5" 10’-15’ C6.5 0.37 6 1 2" 5 TYPE D Recommended Maximum Pipe Size: 4: 44: 24 PM @ 12" Ctrs. C-I-P 3 4" 3 Grate ( 15’M ax. ) (See Table 2) 3 4" 5 3’-0" HORIZONTAL WALL REINFORCING DEPTH sm 970re Horiz. Wall Reinf. 6" 8" #4 Bars Precast Precast See Index 201 C-I-P C-I-P 3 4" 3 6" @ 12" Ctrs. C-I-P 8" #4 Bars 4’-0" Precast 3 4" 5 Eyebolt Cl. Cl. 2" Cl. See Index 201 334" Precast Grate 3" 2" 2" ( 15’M ax. ) Eyebolt 6" W all Depth Varies 8" C: \d\projects\standards\roadway\00200-s\00232-01. dgn 334" Precast Grate 3" Cl. 4’-1" 334" Precast ( 15’M ax. ) 2’-0" 334" Precast C-I-P C-I-P W all Depth Varies 5 5 2" 3 4" C-I-P 3 4" C-I-P W all Depth Varies 3 4" 5 4’-4" C-I-P 5’-1" Precast 3 4" 5 3’-0" Precast 2" Cl. 3’-4" C-I-P 1 2" 5" 1 2" 6" TYPE E Recommended Maximum Pipe Size: Recommended Maximum Pipe Size: 3’-1" Wall - 24" Pipe 3’-0" Wall - 24" Pipe 4’-1" Wall - 36" Pipe 4’-6" Wall - 36" Pipe 3’-1" Wall - 24" Pipe (18" where an 18" pipe LAST REVISION 07/01/05 REVISIO N 6/24/2013 enters a 2’-0" wall) DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 1of 7 10’-1" C-I-P 7’-11" C-I-P 9’-9" Precast 7’-7" Precast »¿ Of C-I-P 6" Precast C-I-P Precast Center Of Box PLAN Precast PLAN 6" 8" 8’-9" C-I-P Center Of Box 3’ -0" 8’-9" 6" 6" Precast 8" 8" 6" 4’ -0" Precast 4’ -4" C-I-P C-I-P 212" 212" 6" 8" 6’-7" 3’ -0" 3’ -0" 6" 8" 6" 6’-7" 8" 8" 8" S S 3’ -0" Pipe Spacing 4’ -0" Precast 4’ -4" C-I-P Pipe Spacing 212" 212" »¿ Of Location Reference Location Reference 7’-11" C-I-P 10’-1" C-I-P 7’-7" Precast 9’-9" Precast 6’-7" 8’-9" Grate #4 Bars @ 12" Ctrs. 8" C-I-P Horiz. Wall Reinf. (See Table 5) 3" Cl. 2" Cl. (See Table 4) ( 10’M ax. ) W all Depth Varies 3" Cl. Eyebolt See Index 201 #4 Bars @ 10" Ctrs. C-I-P (Short Bars) SECTION Precast (Short Bars) HORIZONTAL WALL REINFORCING HORIZONTAL WALL REINFORCING SCHEDULES (TABLE 4) SCHEDULES (TABLE 5) AREA WALL DEPTH SCHEDULE (in.†/ft.) MAX. SPACING BARS WALL WWF DEPTH 0’-5’ B5.5 0.24 512" C6.5 0.37 1 2" 6 D4.5 0.53 412" MAX. SPACING (in.†/ft.) BARS WWF 0.37 312" C3.5 3" 0.53 1 4 2" 4" 6" 5’-10’ 7’-15’ AREA SCHEDULE 5" 0’-5’ 5’-7’ sm 970re @ 12" Ctrs. #4 Bars @ 10" Ctrs. SECTION Precast 4: 44: 26 PM #4 Bars 6" Horiz. Wall Reinf. 2" Cl. ( 15’M ax. ) See Index 201 6" 8" C: \d\projects\standards\roadway\00200-s\00232-02. dgn W all Depth Varies Grate Eyebolt D4.5 4" TYPE H (2 & 3-GRATE INLET) TYPE H (4-GRATE INLET) Recommended Maximum Pipe Size: Recommended Maximum Pipe Size: 3’-0" Wall - 24" Pipe 3’-0" Wall - 24" Pipe 6’-7" Wall - 1-60" Pipe 8’-9" Wall - 1-78" Pipe GENERAL NOTES See Sheet 3 of 7. LAST REVISION 07/01/05 REVISIO N 6/24/2013 Or 2-24" Pipe (S=3’-5") Or 2-30" Pipe (S=4’-3") DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 2 of 7 3’-4" 1 2 2" 1 8" 2 1 2 2" 6’-6" 1 1 2" 3 " 4 1 1 2" HAL F SECTI ON CAST I RON GRATES 6’-6" 8’-8" TYPE E TYPE H ( 3GRATE I NL ET) TYPE H ( 4 GRATE I NL ET) Approx. Weight 465 Lbs. Approx. Weight 725 Lbs. Approx. Weight 967 Lbs. TYPE C Approx. Weight 235 Lbs. 1 2" 2" 212" 1 1 1 2" 2" 2" 2" 2" 2" CAST IRON GRATES 8’-8516" 0" Clearance Over Rivets 1 4" 114" Straight Bars 2" x x 3 16" Reticuline Bars 15 Equal Spaces 15 Equal Spaces 14 Straight Bars 2 End-Bearing 2 End-Bearing 1 4" x Straight Bars 2" x 3 16" Band Band Band 11 Straight Bars 2’-178" 1 " 2 2’-178" 1 " 2 2’-1316" 1 " 2 (Typ.) Band (Typ.) Reticuline Bars 3’ -4 3’ -412" Band Band TYPE E 114" Band 2’-178" " 22 Bars 21 Spaces 5 16" 4’ -5 Band Band 15 Bars 1 3’ - 8" Band Band Reticuline Bars 14 Spaces 15 Bars 14 Spaces 1 3’ - 8" C: \d\projects\standards\roadway\00200-s\00232-03. dgn Straight Bars 2"x TYPE D 10 Equal Spaces 3’-2 14 Straight Bars 4’-5" TYPE C 5 16" 5 16" 3’-2 3’-4" 2’-4" 3’ -4" 2" 1 2" 1 1 1 2" 1’ -5" 1 2" 1 2" 1’ -5" 2" 1’ -5" 1 2" 2 3’-4" 1 2 2" 1 3’ -4" 4’ -4" 3 4" 1 1 2" 2" 1 2" 3 1 4" 2" 3 1 4" 1 4’ -4" 2" 1" 2 2" 2" 2 2’-4" 1 2" 1 2" 2" 3 4" 1 1 2" 3’ -0" 3 4" 1 3’ -0" »¿ Of 1 2 8" 2" 3 " 4 1 2 8" 1’ -5" PERMITTED ON INLET TYPE D 1 2 2" 2" 1 2 2" 8’-8" CAST IRON GRATE NOT 2" 3’ -4" 11" 3’ -4" 2 11" 2" 2" 2" 2" 2" 3 4" 1 8" 2’-4" 1’-5" 1’-5" Band (Typ.) 1 " 8 TYPE H (2-GRATE INLET) 1 4" 114" x Straight End-Bearing Bars 2" x 3 16" Bands 2" x 14" Bands 2" x 14" Bands 2" x 14" Approx. Weight 104 Lbs. Approx. Weight 190 Lbs. Approx. Weight 215 Lbs. Straight Bearing Bars 2" 3 8" x 14" Clearance Over Rivets (Typ.) Banding Bars 2" x 1 4" TYPE H (4-GRATE INLET) Straight End-Bearing Bars 2" x 14" Approx. Total Weight 310 Lbs. Reticuline Bars 114" x 316" Reticuline Bars 114" x 316" Banding Bars 2" x 3 16" Approx. Total Weight 388 Lbs. STEEL GRATES NOTE: Steel Grates Are Required On Inlets With Traversable Slots And On Inlets where Bicycle Traffic Is Anticipated. GENERAL NOTES 1. These inlets are suitable for bicycle traffic and are to be used in ditches, non-traversable slots. Subject to the selection described above, when Alternate medians and other areas subject to infrequent traffic loadings but are not to be G grate is specified in the plans, either the steel grate, hot dip galvanized after placed in areas subject to any heavy wheel loads. These inlets may be placed in fabrication, or the cast iron grate may be used, unless the plans stipulate the areas subject to occasional pedestrian traffic such as landscaped areas and particular type. 8. Sodding to be used on all inlets not located in paved areas and paid for under contract unit price for Performance Turf, SY. 9. For supplementary details see Index No. 201. sm 970re pavement areas where pedestrians can walk around the inlet. 4. Recommended maximum pipe sizes shown are for concrete pipe. Size for other 2. Inlets subject to minimal debris should be constructed without slots. Where 1 2" debris is a problem inlets should be constructed with slots. Slotted inlets located within roadway clear zones and areas subject to pedestrians shall have 10. All reinforcing is Grade 60 bars with 2" min. cover unless otherwise noted. Bars to be cut or bent for 1 types of pipe must be checked for fit. clearance around pipe opening. Provide one additional #4 bar above and at each side of pipe opening. 5. All exposed edges and corners shall be 34" chamfer or tooled to 14" radius. 4: 44: 28 PM traversable slots. The traversable slot modification is not adaptable to inlet Type H. Slots may be constructed at either or both ends as shown on plans. 6. Concrete inlet pavement to be used on inlets without slots and inlets with Traversable slots shall not be used in areas subject to occasional bicycle non-traversable slots only when called for in the plans; but required on all traffic. traversable slot inlets. Cost to be included in contract unit price for inlets. Quantities shown are for information only. Steel grates are to be used on all inlets with traversable slots. Either cast iron 7. Traversable slots constructed in existing inlets shall be paid for as inlets or steel grates may be used on inlets without slots where bicycle traffic is not partial. For conversion work and method of payment see ’TRAVERSABLE SLOT anticipated. Either cast iron or steel grates may be used on all inlets with INLETS (PARTIAL) FOR EXISTING INLETS’. LAST REVISION 07/01/10 REVISIO N 6/24/2013 3. Steel grates are to be used on all inlets where bicycle traffic is anticipated. DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 3 of 7 A B 2’ Slot W idth Varies ( 5’Std. ) Flow Ditch W idth 5’ C C 3 4" Sod Chamfer 2’ Concrete Inlet Pavement (Hand Shape to Neat Lines) Sod A B 2’ HALF PLAN WITH SLOT HALF PLAN WITHOUT SLOT PLAN VIEW Varies Varies 18" 18" Ditch Width Varies Sl o pe Var i es Varies es i Var pe o Sl Varies (5’ Std.) Sl o pe Var i es A 18" Varies Ditch Width Varies es i Var pe o Sl Varies (5’ Std.) 3’ B 18" 4" Varies Ditch 6" 6" 8" 3" 7" (Slot Depth) 3" 8" 8" 3" 3" 8" 8" Bottom 8" C: \d\projects\standards\roadway\00200-s\00232-04. dgn 18" 6" 6" 6" 6" SECTION BB sm 970re SECTION AA A B HALF PLAN WITH SLOT HALF PLAN WITHOUT SLOT PAVEMENT AND SODDING QUANTITIES SECTION CC 4: 44: 30 PM FOR TRAVERSABLE SLOTS Pavement LAST REVISION 07/01/07 REVISIO N 6/24/2013 Inlet Single Slot Sod Double Slot Single Slot Double Slot SY CY SY CY SY SY C 4.87 0.77 6.16 0.93 12 16 D 5.99 0.91 7.70 1.10 14 19 E 5.88 0.91 7.37 1.08 14 18 TRAVERSABLE SLOTS DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 4 of 7 2’ B 2’ Sod Inlet Pavt. Sod SLOTS NOT A A C 6 D 6 2’ SIDES WITH GRATE SEATS Slot Slot Depth 0.30 8 0.36 9 0.37 9 H 8 H 0.45 11 10’ Ditch Block (Low Side Of Inlet On Continuous Ditch) Sod Existing Or Proposed Structure 3" Concrete Inlet Pavement SOD ONLY Slot Traversable Or Non-traversable (Traversable Shown) PAVT. AND SOD Otherwise Ditch Bottom 8" 6" (Paved or Unpaved Ditches) Width Of 1 : 2 0 Ditch Bottom Toe Wall Required E 1’-6" 12" Unless C D 7 1’-6" PLAN SY E (Grate Not Shown) B CY 2’ PERMITTED ON Width Of 0 2 : 1 Inlet SY NOTE: See General Notes Nos. 6 and 7, Sheet 3 of 7. Shown On DITCH BLOCK FOR INLETS WITH OR WITHOUT SLOTS SODDI NG AND PAVEMENT FOR I NL ETS WI THOUT Slot Plans SL OTS AND I NL ETS WI TH NONTRAVERSABL E SL OTS SECTION AA SECTION BB NONTRAVERSABL E SL OTS Existing Cast Iron Grate(s) To Be Replaced With Steel Grates. Existing Steel Reticuline Grates To Be Replaced When Called For A es i Var pe o Sl Varies (5’ Std.) 3" Varies 18" Varies Ditch Width Varies Sl o pe Var i es 18" Sl o pe Var i es Ditch Width Varies 18" In The Plans Or As Directed By The Engineer. 4" Varies 3’ Varies es i Var pe o Sl Varies (5’ Std.) 18" Const. Conc. 3" Varies 18" B Inlet Pavt. & Slot 6" 6" 6" 6" 8" 7" (Slot Depth) 4" 8" Ditch Bottom 8" 3" 8" 8" 8" C: \d\projects\standards\roadway\00200-s\00232-05. dgn Inlet Pavt. 3" Const. Conc. 5" (Min.) 6" 6" Bottom Of Exist. 12" 4" Const. Conc. Inlet Slot Or Remove Exist. 3" Pavt. & Slot Wall To This Line (Exposed 4" Rebars In Pavt. Zone May Be Either Removed Or Embedded). Exist. Inlet With Exist. Inlet With Or Without Slots Or Without Slots SECTION AA A SECTION BB B SINGLE SLOT SHOWN (DOUBLE SLOTS sm 970re SYMMETRICAL ABOUT CENTERLINE) SECTION CC (CASE I) PAVEMENT AND SODDING QUANTITIES 4: 44: 32 PM FOR TRAVERSABLE SLOTS Pavement Inlet LAST REVISION 07/01/00 REVISIO N 6/24/2013 C NOTE: Sod For plan view and additional details see Sheet 4 of 7. For payment see General Notes Nos. 6 and 7, Sheet 3 of 7. Single Slot Double Slot Single Slot Double Slot SY CY SY CY SY SY 4.87 0.83 6.16 1.05 12 16 D 5.99 1.01 7.70 1.30 14 19 E 5.88 0.99 7.37 1.24 14 18 TRAVERSABLE SLOTS FOR EXISTING INLETS DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 5 of 7 DESIGN NOTES FOR TRAVERSABLE SLOT ¡ Existing Cast Iron Grate To Be Replaced INLETS (PARTIAL) FOR EXISTING INLETS With Steel Grate. Existing Steel Reticuline 1. The general purpose of these conversions is to remove the hazard of the Grate To Be Replaced When Called For In The protruding inlet top, while not creating a hazard by depressing the top too deeply. Plans Or As Directed By The Engineer. A 4" 2. The corrective procedure depends on the approach ditch grade and hydraulic B requirements of the site. The selection of the appropriate case depends on the Varies 3’ relationship between inlet top and ditch elevation, and, on the vertical clearance 18" between the top of the uppermost pipe(s) and the grate. The purpose for the Case 1 conversion is to add the traversable slot to an existing inlet where top removal, Break Angle Not To change in grate elevation and ditch transitions are not required. Case 2 will Varies Exceed 3 (1:20) Exist. Ditch Bottom normally be applicable to ditches with flatter grades adjoining the inlet. Case 3 Remove This Portion Of Varies (See Plans) will normally be applicable to ditches with steeper grades adjoining the inlet Box And Construct New Const. Conc. Inlet Pavt. & Slot 3" (Box With Slot Shown) where build up of the existing ditch is acceptable. Top, Seats And Slot(s) 3. The designer shall stipulate in the plans which case is to be constructed at each Bottom Of Transition Ditch 8" 3" These Points Can Be 3" 8" individual inlet location. 7" (Slot Depth) Where the existing inlet top is above the existing ditch (Case 2) but borrow Grate The Same Where Ditch 6" Grades Are Flat 4" The Same Or Nearly material will be required to adjust the ditch (Case 3), and vertical clearance or 6" 5" (Min.) 3" 4" Remove Exist. Wall To This other conditions do not prevent removal of the inlet top, the designer should call Line (Exposed Rebars In for Case 2. The designer shall determine if ditch reconstruction is required more Pavt. Zone May Be Either than 35 feet beyond any traversable slot side and shall include separate pay items Removed Or Embedded) in the plans to cover the cost for that portion of required ditch reconstruction exceeding the 35 foot limit. The designer shall also determine whether ditch pavement is required for ditch restoration within the 35 foot limit and include that pavement under a pay item separate from the inlets partial. Exist. Inlet With Or Without Slots When the detention ditch concept is to be used with Case 3, the designer shall A stipulate ’Case 3 (Detention)’ in the plans. B The designer shall determine whether tight soil or other conditions at each Existing Cast Iron Grate To SINGLE SLOT SHOWN (DOUBLE SLOTS SYMMETRICAL ABOUT CENTERLINE) Be Replaced With Steel Grate. ¡ SECTION CC (CASE 2) individual inlet indicates the need for underdrain in Case 3 conversions and shall call for Underdrain, Type I in the plans. Existing Steel Reticuline Grate For In The Plans Or As 4" Directed By The Engineer. Break Angle Not To Exceed 3 (1:20) Minimum Slope For Transition Ditch 10’ Level 3’ Varies METHOD OF PAYMENT FOR TRAVERSABLE SLOT INLETS (PARTIAL) FOR EXISTING INLETS 18" 0.10% Unless Existing Ditch Is Flatter. 1. Existing inlets converted to traversable slot tops under Cases 1, 2 and 3 shall be Bottom Of Transition Ditch; 3" Or Bottom Of Exist. Ditch For Exist. Inlet Without Slot Const. Conc. Inlet paid for as inlets partial, each. Case shall not be included in the pay item Pavt. & Slot description. Ditch Grade For 3" 3" 8" 7" (Slot Depth) 8" 2. All ditch reconstruction work within 35 feet of each traversable slot conversion, 20 1: Detention Concept whether required by these details or as a direct result of the conversion, shall be included as a part of the partial cost. Reconstruction work shall include excavation and removal of surplus materials or borrow materials in place, grading, Bottom Of Exist. Ditch Bottom Of Exist. 12" Slot For Exist. Inlet With Slot * 4" 25’ 6" * 6" 2’ C: \d\projects\standards\roadway\00200-s\00232-06. dgn To Be Replaced When Called B A 5" (Min.) 3" Slope Same As Exist. Ditch Or Remove Exist. Wall To This Line (Exposed Rebars compaction, shaping and restoration of disturbed turf. Sodding, ditch pavement and underdrain are not included as part of the inlet partial cost and are to be paid for separately. In Pavt. Zone May Be Either 4" Removed Or Embedded) 3. Concrete inlet pavement and sodding shall be in accordance with the sections on this detail and with the Plan on Sheet 4 and Sections AA, BB and CC (as Case 1) sm 970re and tabular quantities on Sheet 5. Underdrain, Type I To Be Constructed Only With Detention Ditch Concept, And Only When 4: 44: 34 PM Called For In The Plans 4. Unit price and payment shall constitute full compensation for inlet conversion *Extra Pavement When Exist. A Slot Exceeds 12" In Depth (including concrete inlet paving and replacement grate(s)), ditch reconstruction, B SINGLE SLOT SHOWN (DOUBLE SLOTS SYMMETRICAL ABOUT CENTERLINE) Exist. Inlet With restoration of disturbed turf, and shall be paid for under the contract price for Or Without Slot Inlets (DT Bot) (Type __) (Partial), each. Sodding shall be paid for under the contract unit price for Performance Turf, SY. SECTION CC (CASE 3) Ditch pavement shall be paid for separate from the inlet by pavement type(s) and 6/24/2013 unit(s) as called for in the plans. LAST REVISION 07/01/07 REVISIO N TRAVERSABLE SLOT INLETS (PARTIAL) FOR EXISTING INLETS DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 6 of 7 Inlet Types C, D, & E Type C 3’-1" Type D 4’-1" A Type E 4’-6" #4 Bar Each Corner Centered Inlet Structure Bottom 2 Way Reinforcement See Tables 6’-0" Unless Otherwise B B Shown On Plans #5 Hoop Bar Type E 3’-0" Alt. B Structure Bottom (2’-0" Min. Length) Type C 2’-0" Type D 3’-1" (Peripheral Reinforcement) Centered 3’-6" Unless Otherwise Shown On Plans OpeningSee Table TOP SLAB For Dimensions REINFORCING SCHEDULE See Index No. 200 for structure bottom details and hole reinforcement. AL T.B STRUCTURE BOTTOM FOR GRADE 60 (BAR) OR 65 KSI & SCHEDULE A In.†/ft. TOP VIEW #8 Bars TOP SLAB OPENINGS DIAMETER I NL ETS TYPE C,D & E 70 KSI (WIRE FABRIC) A 0.20 B 0.24 C 0.37 D 0.53 E 0.73 F 1.06 G 1.45 OPENING SIZE MIN. MAX. 4’-0" 2’-0" x 3’-1" 2’-0" x 3’-1" 5’-0" 2’-0" x 3’-1" 3’-1" x 4’-1" 6’-0" 2’-0" x 3’-1" 3’-0" x 4’-6" 8’-0" 2’-0" x 3’-1" 3’-0" x 4’-6" TOP SLAB WITH TOP SLAB REINFORCING DIAGRAM CENTERED OPENING REINFORCING SLAB SLAB DEPTH THICKNESS (2 WAYS) SIZE: 4’-0" C D 9 Top Slab With Centered Opening 1 2" 9 For 4’-0"/5’-0"/6’-0" Structure Bottoms SIZE: 6’-0" 1112" For 8’-0" Structure Bottoms 2" Cl. #5 Hoop Bar #4 Bars 0.5’ < 8’ 912" B 8’ < 18’ 912" C 18’ < 30’ 912" D 30’ < 37’ 9 1 2" E 912" G 2" Cl. TYPE C 4’-0" TYPE D 6’-0" TYPE E 6’-0" (Minimum Diameter Each Corner Round Structure Bottom See Index No. 200 For 37’-40’ Structure Bottom Details and Hole Reinforcement. SIZE: 8’-0" sm 970re Unless Otherwise Shown In The Plans) 2" Cl. #8 Bars @ 5" Spacing 2 Way Reinforcement =0.5’ < 9’ 1112" C 9’ < 15’ 1112" D 15’ < 23’ 11 1 2" E 23’ < 33’ 1112" E 33’-40’ 1112" G 4: 44: 36 PM See Tables SECTION BB 1 1 ~ Extra #4 Bar 1 2" 1 Cl. Each Side And Above Pipe Openings Alt. A Centered) C 1 2" 9 30’-40’ ( Alt. B Shown, 1 2" =0.5’ < 30’ Structure Bottom SIZE: 5’-0" Type E 4’-6" Inlet Type C, D, E & H Type C 3’-1" Type D 4’-1" 6" Min. 1 . 2" Cl 1 2" 9 3" M in. =0.5’-40’ 6" M in. C: \d\projects\standards\roadway\00200-s\00232-07. dgn SCHEDULE PIPE OPENING SCHEMATIC 6/24/2013 SECTION AA LAST REVISION 07/01/05 REVISIO N ALT. A STRUCTURE BOTTOM FOR INLETS TYPE C, D AND E DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS DITCH BOTTOM INLET TYPES C, D, E AND H NO. 232 SHEET NO. 7 of 7