10" Pole Base in Base Shoe Casting see Sheet 4
»¿ »¿ For Fixture Arm Details Luminaire, not furnished see Sheet 3 (Typ.) with Pole Assembly (Typ.) 6" Pole top with Cast Aluminum 3’-0" or 5’-6" see Sheet 4 17" High Frangible/ Breakaway Transformer Base see Sheet 4 Fixture Arm Length (8’, 10’ or 12’ only) (8’, 10’ or 12’ only) 4"x6" (Min.) Handhole with reinforced frame and cover with Hex 11" Transition zone with reinforced frame and cover with Hex Head screws. Begin Pole Taper 7" for grades up to 1:2 add A 2’-6" to foundation depths 2’-6" Straight to oblong shape 4"x6" (Min.) Handhole Head screws. Grade flatter than 1:4 from round shape 22’ -5" 22’ -5" to oblong shape Taper Varies from round shape SECTION A-A Pole H eight Transition zone Taper Varies Pole H eight ATTACHED. 40’Design M ounting H eight ( For Pole Design) WITHOUT LUMINAIRE 40’Design M ounting H eight ( For Pole Design) W ind Design H eight at Fixture ( For Pole Design) DO NOT ERECT POLE W ind Design H eight at Fixture ( For Pole Design) NOTE: 7" Fixture M ounting H eight ( from Lighting Design Requirem ents) Fixture M ounting H eight ( from Lighting Design Requirem ents) W ind Design H eight at Fixture ( For Pole Design) Fixture Arm Length 1’ -6" Base Shoe Casting Pole H eight 23’ -2" , 26’ -2" and 29’ -2" for Design 10" Pole Base in M ounting H eight of 40’ , 45’and 50’respectively. factory installed) (Typ.) 40’ , 45’or 50’Design M ounting H eight ( For Pole Design) (when specified, Taper Varies Fixture M ounting H eight ( from Lighting Design Requirem ents) A A Begin Pole Taper 2’-6" Straight A shown in Tables. Finished Grade DANGER Line adjacent 7: 22: 17 PM to poles on fill Natural Ground Natural Ground Line adjacent Line adjacent to poles on fill to poles on fill MEDIAN BARRIER MOUNTED ALUMINUM LIGHT POLE ON CYLINDRICAL FOUNDATION MEDIAN BARRIER MOUNTED ALUMINUM LIGHT POLE ON SPREAD FOOTING FOUNDATION 6/24/2013 STANDARD ROADWAY ALUMINUM LIGHT POLE (See Roadway Plans) 70’M ax. on Sheet 4 Finished Grade (See Roadway Plans) Fill H eight foundation see details Finished Grade 70’M ax. 2’-6" Concrete Fill H eight DO NOT TAMPER 25’M ax. HIGH VOLTAGE Fill H eight C: \d\projects\standards\roadway\17500-s\17515-01. dgn Vibration Damper Natural Ground sm 970re Cap attached to pole with 3 Stainless Steel Set Screws (Typ.) See Sheet 3 (Typ.) Fixture Arm Length LAST REVISION 01/01/10 REVISIO N ELEVATIONS DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 1of 8 ALUMINUM LIGHT POLE GENERAL NOTES MEDIAN BARRIER MOUNTED ALUMINUM LIGHT POLE 1. Designed in accordance with FDOT Structures Manual. 1. 2. All tables were developed assuming the following Luminaire properties: Effective Projected Area of 1.55 sq. ft. b. Concrete: Class I. (includes wind drag coefficient) and 75 pounds (max.) c. Anchor Bolts: ASTM F1554 Grade 55 with ASTM A563 Grade DH nuts and ASTM A36 Plate Washer Foundation Materials: a. Reinforcing Steel: ASTM A615 Grade 60. or ASTM F436 Type 1 washers (all galvanized in accordance with ASTM F2329). Coupler shall be in 3. Perform all welding in accordance with the American Welding Society Structural Welding Code Aluminum ANSI/AWS accordance with AASHTO 5.11.5.2.2. D1.2 (current edition). 2. 4. See Standard Index No. 17500 for grounding and wiring details. 5. Light Pole Specifications: Base Connection Materials: a. Aluminum Base Plate and Stiffener: Alloy 6061-T6. b. Backer Ring: ASTM B221, Alloy 6063-T6. c. Bearing Plate for Anchor Bolts: ASTM A709 Grade 36 or ASTM A36. a. Poles: ASTM B221, Alloy 6063-T6. b. Arm Tube Extrusions: ASTM B221 - Alloy 6063-T6. c. Finish: For pole and arms; 50 grit satin rubbed finish. d. Pole Connection Extrusions, Bars and Plates: ASTM B221 - Alloy 6063-T6. e. Aluminum Caps and Covers: ASTM B-26(319-F). f. Weld Metal: ER4043. b. Transverse welds are allowed only at the base. g. Stainless Steel Fasteners and Hardware: AISI Grade 304. c. Poles constructed out of two or more sections with overlapping splices are not permitted. h. Aluminum alloy 6063: T4 condition and heat treated in accordance with ASTM B597 to T6. d. Equip poles with a damping device. i. Frangible Base: ASTM B26 Alloy 356-T6 or ASTM 108 Alloy 356-T6. 3. Pole Notes: a. Tapered as required to provide a 6" (O.D.) round top with a 11"x7" (O.D.) oblong base. Portions of the shaft near the base and at the arm connections may be held constant at 11"x7" oblong and 6" round respectively to simplify fabrication. 6. Provide "J", "S" or "C" hook at top of pole for electrical cable. 7. Furnish each pole with a 2"x4" (max) aluminum identification tag. Submit details for approval. Secure to Transformer Base with 0.125" stainless steel rivets or screws. Locate Identification Tag on the inside of base and visible from the door opening. Include the following information: Financial Project ID, Pole Height and Manufacturer’s Name. 8. For Clamp and Frangible Transformer Base Design, certify that the components are capable of providing the required capacity. Certify that the frangible Transformer Base conforms to the current FHWA required AASHTO FOUNDATION NOTES Frangibility Requirements, tested under NCHRP Report 350 Guidelines (eg. Akron Foundry TB1-17). 9. For Median Barrier Mounted Aluminum Light Pole design, submit test results showing that pole will not buckle at The foundations for Standard Roadway Aluminum Light Poles are pre-designed and are based upon the pole shape transition area. Demonstrate in the tests that the poles will achieve full ultimate moment capacity of 36 following conservative soil criteria which covers the majority of soil types found in Florida: k-ft in the strong axis and 30 k-ft in the weak axis respectively for the 0.25" thick poles, and 44 k-ft in the strong Classification = Cohesionless (Fine Sand) axis and 37 k-ft in the weak axis respectively for the 0.313" thick poles. Submit complete details and calculations Friction Angle = 30 Degrees (30) for the reinforced 4"x6" (min.) handhole located 1’-6" above the base plate. Unit Weight 50 lbs./cu. ft. (assumed saturated) = Only in cases where the Designer considers the soil types at the specific site location to be of lesser strength 10. This Design Standard is considered fully detailed and no shop drawings are necessary. Submit shop drawings for properties should an analysis be required. Auger borings, SPT borings or CPT soundings may be utilized as needed to verify the assumed soil properties, and at relatively uniform sites, a single boring or sounding may minor modifications not detailed in the plans. cover several foundations. Borings in the area that were performed for other purposes may be used to C: \d\projects\standards\roadway\17500-s\17515-02. dgn confirm the assumed soil properties. ROADWAY ALUMINUM LIGHTING POLE NOTES EMBEDDED JUNCTION BOX NOTES 1. 1. Foundation Materials: Fabricate embedded junction boxes from ASTM A 36 steel and hot-dip galvanized in a. Reinforcing Steel: ASTM A615 Grade 60. accordance with ASTM A 123 after fabrication. All seams shall be continuously welded b. Concrete: Class I. and ground smooth. Provide watertight cover with neoprene gasket and secure cover with c. Anchor Bolts: ASTM F1554 Grade 55 with ASTM A563 Grade DH nuts and ASTM F436 Type 1 washers galvanized screws. (all galvanized in accordance with ASTM F2329). 2. 2. Shoe Base and Frangible/Breakaway Transformer Base Casting Specifications. Completed embedded junction box and conduit risers are incidental to the cost of concrete barrier wall. a. Shoe Base Casting: ASTM B26 - Alloy 356-T6 or ASTM B108 - Alloy 356-T6. b. Frangible/Breakaway Transformer Base Casting: ASTM B26 - Alloy 356-T6 or ASTM B108 - Alloy 356-T6. c. Shoe Base Connection Bolts: ASTM A325 Type 1 with ASTM A563 Grade DH nuts and ASTM F436 Type 1 washers (all galvanized in accordance with ASTM F2329). sm 970re 3. Pole Notes: a. Tapered as required to provide a top outside diameter (O.D.) of 6" with a base O.D. of 10". Portions of the shaft near the base shoe and at the arm connections may be held constant at 10" and 6" respectively to simplify fabrication. b. Transverse welds are allowed only at the base. c. Poles constructed out of two or more sections with overlapping splices are not permitted. 6/24/2013 7: 22: 18 PM d. Equip poles with a vibration damper at locations per Specification Section 715. LAST REVISION 07/01/13 REVISIO N NOTES DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 2 of 8 Upper Arm 1 4"– 8 Extrusion at Base Saddle, or Other Acceptable of Upper Arm Only Diameter 7 8" Fillet Weld Arm Tube to 3 8" Connection Thickness (Nominal) Connection Extrusion. Extrusion See Arm Data Tables Supplied 2 * 18" Wall 4" Min. Radius at Bend for Weld Size. 1’ -4" by Vendor Vertical Axis SECTION A-A ARM CONNECTION DETAIL Tapped Hole Watertight 1 8 (Connection At Lower Arm Similar) ARM SECTION 1 16" 112" C Dim ple ( see Detail) Arm Data Tables 3 8" 1" Min. I.D. Rubber Grommet 1’ -2" Outside See "O.D." in B »¿at of Upper Ar 6" At Lower Arm B »¿ of Wiring Hole in 3" Welded Cap 6" Connection Lower Arm 3 16 Press on or Side of Arms, Extruded L 3x2x18"x234" Long C Hole in Connection Upper Arm & 3 16 x 3" Bar Each High Temp Vinyl Cap (both ends) Deep 1 4" Spherical (See Cap Details) 7 8" Provide 2" Wiring 1 2" surface 1 1 2" x 11 1 4" long ASTM A36 Hot Rolled Rod 2" x 12" Long Sch. 10 Aluminum Pipe ASTM B221 Alloy 6063-T6 »¿ 7 8" Fixture Arm Length = 8’, 10’, 12’ or 15’ 3’-0" 3 x (Fixture Arm Length - 3’-0") / 4 (Fixture Arm Length - 3’-0") /4 1 3 8"x2 4" L 3x2x 6" DIMPLE DETAIL Watertight 1 8 Long (Typ.) 1’-4" 3 8" Tapped Hole 238" O.D. Pipe Beyond This Point - See Arm VIBRATION DAMPER ELEVATION Tube Extrusion Note 1’ -0 " »¿ Fixtur 3 3 8" 1 8" 1 ASTM D2287 2 PVC Type 65500 3 8" Upper Arm Tube Tapped Hole 3 4" C: \d\projects\standards\roadway\17500-s\17515-03. dgn Double arm configuration Chamfer (Typ.) 234" 1 2" is only for Median Barrier 1 Mounted Aluminum Light Poles 1 VIEW B-B 3 16 See Arm Connection Detail 3 8" 1 2" 1 ID 2" x 12" Long Sch. 10 Aluminum Pipe ASTM 6" Strut - 1 1 2" Tapped Hole A As Required B221 Alloy 6063-T6 O.D. x 0.125 (Min.) 1’ -9" A Lower Arm Tube - HIGH TEMP VINYL CAP DETAIL VIEW C-C See Arm Section Above ARM TABLE WIND ARM SPEED LENGTH (MPH) (FT) UPPER ARM O.D. (IN) WELD (IN) LOWER ARM O.D. (IN) WELD (IN) Provide 18" (Min.) Drain Holes in Underside »¿ A of Arm Tubes 112" From the Base Weld 110 110 sm 970re 110 7: 22: 20 PM Varies 6" 4’ -6" M Luminaire Attachment 5’-6" (12’ and 15’ Fixture Arm Lengths) 1" 1" Slipfitter (238" O.D.) for 3’-0" (8’ and 10’ Fixture Arm Lengths) 2" 2" Nominal Pipe Size 3" axi mu m R adi us Level 1 1 2" See Arm Section Above 8 10 & 12 15 2.38 0.188 2.38 0.188 3.63 0.188 3.63 0.188 4.63 0.188 4.63 0.188 130 8 & 10 3.63 0.188 3.63 0.188 130 12 4.63 0.188 4.63 0.188 Face of Pole ARM TUBE EXTRUSIONS NOTES: At the pole connections, provide arm tube extrusions with dimensions as Provide Pole Connection Extrusion (Typical) - See Note on Sheet 2 for Material Specification 1 2" Stainless Steel Bolts with Hex Nuts 1 8" and 2-1 O.D. Flat Washers and a Split Lockwasher Each Side shown in the ARM SECTION and as tabulated in the ARM DATA Tables. Uniformly transition elliptical section to a cylindrical section at the arm connection. The fabricator may substitute elliptical cross sections other than those 130 15 4.63 0.25 4.63 0.25 150 8 3.63 0.188 3.63 0.188 150 10 3.63 0.250 3.63 0.250 provide minimum wall thickness of 150 12 4.63 0.250 4.63 0.250 Association Tolerances. 150 15 4.63 0.313 4.63 0.313 of Pole where Shown. ARM ELEVATION tabulated, provided the section properties about the vertical axis and the area of the section equal or exceed that of the required section, and 1 8" nominal and within the Aluminum The outside diameter about the minor axis should be held at 238" at the * upper and lower arms. Increase Member Wall Thickness as Necessary to Meet Minimum Requirements of the Welding Code for the 6/24/2013 Connection Weld Sizes Shown in the Arm and Pole Tables. LAST REVISION 01/01/12 REVISIO N ARM & DAMPER DETAILS DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 3 of 8 1 ’ -0 " L a p Tie Bars * Slots for 15" Bolt Circle Slots for Cast Aluminum Base Shoe 1312" Bolt Circle »¿ Po »¿ 8 - #7 Bars Equally Spaced r ve Co ) 3" p. Ty ( POLE TABLE WIND SPEED (MPH) SECTION C-C TOP VIEW TRANSFORMER BASE BOTTOM VIEW TRANSFORMER BASE 5 16" Typical »¿ Po 5 45 Typ. »¿ Each W ay 2’-6" Cast Aluminum Fillet Weld Outside of Pole Pressure Mounted to Inside of Base Shoe. Nut Cover - Bolted See Pole Data Tables Attachment Optional for Upper Weld Size. DESIGN ARM LENGTH (FT) MOUNTING HEIGHT (FT) POLE UPPER WALL (IN) LOWER WELD (IN) WELD (IN) 110 8, 10, 12 & 15 40 & 45 0.156 0.156 0.156 110 8, 10, 12 & 15 50 0.188 0.188 0.188 130 8, 10 & 12 40 0.156 0.156 0.156 130 15 40 0.188 0.188 0.188 130 8, 10, & 12 45 0.188 0.188 0.188 130 15 45 0.250 0.250 0.250 130 8, 10, 12 & 15 50 0.250 0.250 0.250 150 8, 10, & 12 40 0.188 0.188 0.188 0.250 150 15 40 0.250 0.250 150 8, 10, 12 & 15 45 0.250 0.250 0.250 150 8, 10, 12 & 15 50 0.313 0.313 0.313 NOTE: Pole wall thicknesses shown in the POLE TABLE are nominals and 5516" 1’-3" shall be within the Aluminum Association Tolerances. Thicker walls are permitted and tapered walls may be used provided the 10" O.D. Shaft minimum Aluminum Association thicknesses are not violated. Bolt Circle 4 - Equally Spaced VIEW B-B See Pole Data Tables Anchor Bolts Oriented for Wall Thickness as Shown when the Shaft is Installed. Anchor Bolt, See Note M in. 312" B Cast Aluminum (Typ.) 1" See Note on WIND DESIGN TOTAL Sheet No. 2 SPEED MOUNTING DEPTH (MPH) HEIGHT (FT) (FT) ** Fillet Weld Butt of Pole 110 40 7 to Inside of Base Shoe. 110 45 & 50 8 130 40 & 45 8 130 50 9 150 40 & 45 9 150 50 10 See Pole Data Tables for Lower Weld Size 1’ -5" M inim um Em bedm ent Elbow 1" Min. 3’ -6" 4" C Conduit with Tie Bars * 6’ -0" M inim um ( See Pole Data Tables for Depth Required) C FOUNDATION TABLE Base Shoe 1" Chamfer ** Depths shown in table are for grades flatter than 1:4, for grades Cast Aluminum up to 1:2 add 2’-6" to foundation DANGER Frangible/Breakaway HIGH VOLTAGE depths shown in table. DO NOT TAMPER Transformer Base. See Notes on Sheet No. 2 Anchor Bolt, Connection Bolt, Washer and Split Double #6 AWG Bare Ground Nuts (Typ.) Lockwasher as Required Wire Cast in Concrete by Approved Breakaway or Placed in Conduit Transformer Base POLE BASE ELEVATION 8~#7 Bars Equally Spaced * 1. Manufacture (Typ.) Shop-weld assemblies of foundation stirrup reinforcing bars are permitted in reinforced Class I Concrete may be concrete foundation provided that: Cast-in-Place or Precast a. The reinforcing bars conform to ASTM Specification A706/706M. b. The holding wires conform to ASTM Specification A1064. c. The Shop welding is performed by machines under a continuous, controlled 4" 7: 22: 22 PM sm 970re C: \d\projects\standards\roadway\17500-s\17515-04. dgn B 312" in Pole Base Elevation process, approved by the Engineer. d. Quality control yield strength and tensile strength tests are performed on shop-welded specimens and the test results are available, upon request, to 6/24/2013 FOUNDATION the Engineer. 2. #4 Tie Bars @ 12" centers (max.) or D10 (or W10) spiral @ 6" pitch, 3 flat turns top and 1 flat turn bottom. LAST REVISION 01/01/11 REVISIO N BASE DETAILS FOR ROADWAY ALUMINUM LIGHT POLE DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 4 of 8 POLE TABLE 114" Anchor Bolt threaded 8" min. WIND 1 2" top and bottom SPEED 1 1 2"x5"x10 2" 1 4" »¿& Light 214" Bend as shown »¿ Base (FT) (MPH) Stiffener Plate 1 2" DESIGN ARM LENGTH Min. (2 required) R (Typ.) 130 (Typ.) MOUNTING HEIGHT (FT) POLE FILL HEIGHT WALL (IN) (FT) 110 8, 10, 12 40 0.25 Up to 70’ 130 8, 10, 12 40 0.25 Up to 70’ 150 8, 10, 12 40 0.25 Up to 20’ 150 8, 10, 12 40 0.313 >20’ to 70’ *Double Nuts NOTE: 4" Pole wall thicknesses shown in the POLE TABLE are nominals 1 4" and shall be within the Aluminum Association Tolerances. Plate Washer Thicker walls are permitted and tapered walls may be used STIFFENER PLATE DETAIL 2" provided the minimum Aluminum Association thicknesses are 1 4" 1’-6" 134" 714" 312" 714" 2" Leveling Nut Plate Washer 134" 1 Bolt Dia. (Max.) 312" 2" not violated. Base Plate Galv. Coupler 1 2" permitted (Typ.) 1 »¿ Base Hole (Typ.) Top of Penetration Weld Traffic Railing 3 4" »¿& Light Full 1 NOTE: For locations of Bearing Plates, Base »¿ Base 2 1 4" 312" Plates and Detail ’A’ see Sheets 6 & 7. DETAIL ’A’ *Top nut may be height cover (not shown) for each bolt. Backer Ring 3 4" 1 4"x3" 1 2" 1 »¿ Stiffener Plate Detail) 15 16" Hole (Typ.) Full Stiffener Plate (see Penetration Weld BASE PLATE PLAN BEARING PLATE ELEVATION 1 4"x3" Backer Ring Pole Wall 1’-5" »¿ Base »¿& Light 114" Outer Wall of Pole 1 2" 2 1’-0" 114" 1 2" 2 1 2" Backer Ring 1’-212" 2 1 4"x3" 114" Stiffener Plate fillet reinforcing 2" 3 3 8"x 4" 7" w/ 7: 22: 24 PM »¿ 1 2" Hole (Typ.) BEARING PLATE PLAN Hole (Typ.) 6/24/2013 BASE PLATE ELEVATION 1 2" 1516" 2 114" 2" 3 4" sm 970re 3" Full penetration weld 412" 3 8" 5" C: \d\projects\standards\roadway\17500-s\17515-05. dgn 1 2 Jam Nut. Provide individual nut 312" 2 1 4" H 4 " o le 8" »¿& Light LAST REVISION 07/01/09 REVISIO N BASE PLATE DETAILS FOR MEDIAN BARRIER MOUNTED ALUMINUM LIGHT POLE DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 5 of 8 11’-0" 1’-3" 5’-6" 6" Galvanized A 5’-6" Screws (Typ.) 1 4" Typ. (Box and Cover) 3" Symmetrical 1’ -0" 1’ -0" 1" Conduit »¿about Light Cover Plate 7’-3" 6" 4’ -0" with Gasket »¿ Roadway Concrete Barrier 2’ -0" 8’ -0" 2" Conduit A 2" Conduit 1" Conduit 1" Conduit 1 2" 3 4" 1 2" 4" 1 2" 3 1 1’-412" 3" 3 16 1 8 4" (Typ.) 4’ -0" FRONT VIEW 11" EMBEDDED JUNCTION BOX DETAILS 2’ -5" Optional Const. Jt. 1 4" 8 VIEW A-A Provide dowel bars @ construction joint PLAN (Reinforcing steel not shown) 2’-0" 3’-0" 2’-0" 1 2 4" Min. 10’ from free end, barrier wall transition, 2’-3" 1 4" 2 5" approach ends and guardrail. 912" 5" 10" 10" 1" Conduit »¿ 1’-0" x 1’-3" x 8" ( See Detail ’A’ Embedded Junction Box Sheet 5 BARS 5W1 4 ~ 114" Anchor Bolts For Base Plate 3" 3" For reinforcing steel 3 4" 3 @ 8" W all 1’ -0" Nos. 410 & 421 2’ -5" 7" #5 Bars, 4’ long (Typ.) Construction Joint permitted See Roadway Plans 3" 16 ~ #4 Bars @ 8" 1’ -11" 1’ -10" 2’ -9" See Roadway Plans Bars 4D see Design Std. Index 8" 1" Bars 5W1 1’ -0" Bars 5W1 3’ -7" Bars 5R @ 8" (Typ.) Traffic Railing 2’ -9" above foundation BARS 4D Bars 5W1 @ 8" 3" Cover 512" (Top and sides) (Typ.) 1" Exp. Jt. Material with 12 ~ #4 Bars @ 8" Bearing Plate BARS 5R 1’ -6" sm 970re Bearing Plate BAR BENDING DIAGRAMS Rigid Pavement 5 8" #5 Bars @ 8" 1" Conduit for grounding x 20’ Grounding Rod 4" Cover Bars 4D 4" Cover (Bottom) @ 8" (Bottom) #4 Bar 2’ -6" 4" only 2’ -6" 7: 22: 26 PM 3 4" 9 details see Sheet 5 1’ -6" C: \d\projects\standards\roadway\17500-s\17515-06. dgn #5 Bars, 4’ long (Typ.) 12 ~ #5 Bars @ 8" 16 ~ #5 Bars @ 8"– (Typ.) NOTE: 2" Conduit 8’-0" 11’-0" 6/24/2013 2" Conduit For Bearing Plate Details see Sheet 5. 2" Conduit END VIEW ELEVATION (For Roadway Concrete Barrier Wall reinforcing steel see Design Std. Index No. 410) LAST REVISION 07/01/09 REVISIO N SPREAD FOOTING DETAILS FOR MEDIAN BARRIER MOUNTED ALUMIMUM LIGHT POLE DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 6 of 8 2’-0" 214" 7’-3" NOTE: 214" 5" 912" FOUNDATION TABLE 5" For Roadway Concrete Symmetrical »¿about Light Barrier Wall see Design NOTE: Std. Index 410 For Base Plate Details, Base Plate 1’-6" 1’-6" WIND DESIGN FOUNDATION SPEED MOUNTING DEPTH (MPH) HEIGHT (FT) (FT) Bearing Plate Detail 110 40 8 and Detail ’A’ see 130 40 9 150 40 9 Sheet 5 2’-6" 1’-3" 2’ -9" see Design Std. Index No. 421 B B 7" 3" See Roadway Plans 1’-3" with Rigid Pavement 1’ -6" only Double Nuts (Typ.) 25 1’ -6" Provide dowel bars @ construction joint 3’ -0" Bearing Plate #4 Bars (Typ.) »¿ Po »¿ A 2’ -3 " 1" Chamfer (Reinforcing steel not shown) 1’-3" 1" Exp. Jt. Material Optional Const. Jt. PLAN 2’-6" Construction Joint 4" 1’ -0" 1’ -3" 2’ -0" For reinforcing steel above foundation #5 Bars, 4’ long (Typ.) 2’ -6" 3’ -7" 1’ -3" Barrier Wall 1’ -10" »¿ Roadway Con 1" 1’-3" 6" Min. »¿ 1’-0" x 1’-3" x 8" (Max.) Pull Min. 10’ from free end, barrier wall transition, 2’-0" 3’-0" approach ends and 2’-3" #7 Bars guardrail. VIEW B-B C 1" Conduit 4 ~ 1 See Detail ’A’ Sheet 5 1 4" C Anchor Bolts #5 Bars, 4’ long (Typ.) sm 970re Grounding Rod 2" Conduit 8’ -3 to 9’ -3" Varies Tie Bars * Foundation Depth ( See Foundation Table) 2’-6" 2’-6" permitted in reinforced concrete foundation provided that: a. The reinforcing bars conform to ASTM Specification A706/706M. 8 #7 Bars b. The holding wires conform to ASTM Specification A82 or A496. (equally spaced) c. The Shop welding is performed by machines under a continuous, controlled process, approved by the Engineer. d. Quality control tests are performed on shop-welded specimens and the test results are available, upon request, to the Engineer. 2. #4 Tie Bars @ 12" centers (max.) or D10 (or W10) spiral @ 6" pitch, 3 flat turns top and 1 flat turn bottom. Class I Concrete may be Cast-in-Place or Precast with "Flowable Fill" Backfill 4" 7: 22: 28 PM Equally Spaced SECTION C-C ( See Foundation Table) x 20’ 8 - #7 Bars * 1. Shop-weld assemblies of foundation stirrup reinforcing bars are Bearing Plate Foundation Depth 5 8" Traffic Railing 2’ -9" 2’ -6" M in. for grounding »¿ A r ve Co " ) 3 n. i M ( 1’ -0" 4" C: \d\projects\standards\roadway\17500-s\17515-07. dgn 1" Conduit »¿ Po Tie Bars * 1 ’ L 0" a p Tie Bars * Bars 5R @ 8" (Typ.) NOTE: 6/24/2013 avoid cylindrical foundation. ELEVATION 3" Deviate 2" Conduit to END VIEW (For Roadway Concrete Barrier Wall reinforcing LAST REVISION 07/01/09 REVISIO N steel see Design Std. Index No. 410) CYLINDRICAL FOUNDATION DETAILS FOR MEDIAN BARRIER MOUNTED ALUMINUM LIGHT POLE DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 7 of 8 3 4" 9 Symmetrical »¿about Light 3" 3" 3 4" 3 Bridge Deck 7’-3" 1 ’ -2 " »¿ Traffic Railing (Median 32" F S 1 4" 7 5430’ 214" 9" 2’ -0" 214" 2’ -5" 1 4" 7 1 2" 5 (Typ.) A B 1’-412" BARS 5R BARS 5W Optional Const. Jt. Bridge Deck BAR BENDING DIAGRAMS INSTRUCTIONS TO DESIGNER: PLAN In order to minimize vibration of light (Reinforcing steel not shown) poles due to traffic, locate light poles near substructure supports. »¿ 1’-0" x 1’-3" x 8" (Max.) Pull »¿Min. 5’ from open 2’-0" 3’-0" 2’-0" 2’-3" 1 2 4" Bars 5R and 5W @ 1’-0" Bars 5R and 5W @ 8"– 1 4" 2 Bars 5R and 5W @ 1’-0" 5" 912" 5" 1" Conduit 4 ~ 114" Anchor Bolts See Detail ’A’ Sheet 5 Base Plate 2" Conduit Bars 5S 2" Conduit sm 970re Cover M in. see 1’ -10" Design Std. Index No. 421 Bars 5R 7" Bearing Plate Construction Joint 3" Bars 5W Deck 8" Bridge Deck 2’ -8" 3’ -2" M in. Traffic Railing 2’ -8" For reinforcing steel 2" C: \d\projects\standards\roadway\17500-s\17515-08. dgn 1" Conduit Bridge Deck 6" Min. Embedment 8" Min. Bars 5S (Typ.) Bearing Plate Bars 5R (Typ.) ELEVATION END VIEW Bars 5W (Typ.) (Longitudinal and transverse deck reinforcing steel not shown) (Longitudinal and transverse deck reinforcing steel not shown) 7: 22: 30 PM NOTES: 1. For Base Plate Details, Bearing Plate Details and Detail ’A’ see sheet 5. 2. See Design Standard Index No. 421 for details of Traffic Railing (Median 6/24/2013 »¿32" F Shape) and angles A an LAST REVISION 07/01/09 REVISIO N DETAILS FOR TRAFFIC RAILING (MEDIAN 32" F SHAPE) MOUNTED ALUMIMUM LIGHT POLE DESCRIPTION: INDEX FDOT 2014 DESIGN STANDARDS STANDARD ALUMINUM LIGHTING NO. 17515 SHEET NO. 8 of 8