Comments
Description
Transcript
of FDOT 2014 DESIGN STANDARDS
CGL CGL RFL Ch RFL Ch NAVIGATION LIGHT NOTES: RFL 1. Provide Navigation Light System in compliance with Specifications Section 510. »¿ »¿ RFL GCL GCL RFL*** RFL*** Bridge »¿ Br Bridge RFL*** RFL*** GCL Fender GCL (Typ.) PC Fender (Typ.) RFL RFL FROM POWER SOURCE RFL LC Xmer CGL RFL CGL NOTE: GCL GCL NAVIGATION LIGHT SYSTEM SCHEMATIC FOR SINGLE BRIDGE WITH FENDERS FOR DUAL BRIDGES WITH FENDERS Do not use conduit smaller than Ch NAVIGATION LIGHT SYSTEM SCHEMATIC " . RFL or RFL or RFL or RCL RCL RCL CGL CGL RFL or RFL or RFL or RCL RCL RCL »¿ »¿ Ch TYPICAL ELECTRICAL SCHEMATIC DIAGRAM POWER CONDUCTORS RFL or RCL * RFL or RCL * GCL GCL DISTANCE RFL or RCL * RFL or RCL * RFL ** RFL ** LEGEND Bridge RFL ** GCL CONDUCTOR TRANSFORMER 0 - 75 120 #12 AWG N/A 75 - 500 120 or 240 #10 AWG N/A 500-1000 240 #10 AWG N/A 1000-2000 480 #10 AWG 2 KVA Bridge RFL ** Bridge RFL or RCL * VOLTS (feet) SYMBOL DESCRIPTION 2000-5000 480 #8 AWG 2 KVA 5000-10000 480 #6 AWG 2 KVA over 10000 480 #4 AWG 2 KVA RFL or RCL * RFL or RCL * GCL RFL or RCL * sm 970re C: \d\projects\standards\structures\current\ready4release\2014BOOK\21220-1of2. dgn Size conduit and conductors per NEC requirements. LC Lighting Contactor PC Photocell Control Xmer Transformer (If Required) RFL Red Pier/Fender Light (180 visibility) 7: 59: 59 PM or NAVIGATION LIGHT SYSTEM SCHEMATIC NAVIGATION LIGHT SYSTEM SCHEMATIC FOR SINGLE BRIDGE WITHOUT FENDERS FOR DUAL BRIDGES WITHOUT FENDERS * *** RFL to be located at mid length of straight portion of fender. REVISIO N 01/01/12 GCL Green Center Channel Light (360 visibility) CGL Clearance Gauge Light CM Channel Margin or Pier inner surface whichever defines Channel Edge. 6/24/2013 LAST Red Channel Margin Light (180 visibility) Use RFL when Pier is at Channel Edge and see CFR, Title 33, part 118 for Mounting Height restrictions. Use RCL otherwise. ** Mounted only on the Pier that defines CM, otherwise does not apply. REVISION RCL DESCRIPTION: INDEX FDOT 2014 NAVIGATION LIGHT SYSTEM DETAILS DESIGN STANDARDS (FIXED BRIDGES) NO. 21220 SHEET NO. 1of 2 Traffic Railing or Parapet CROSS REFERENCES: EJB 1. For Navigation Light System notes and legend, see Sheet 1. 2. See Utility Conduit Detail sheets for Embedded Junction Box (EJB) dimensions & locations. 2 ~ 2" Conduits Conduit Nipple Back of Traffic Railing Coping Bend if * Mounting Box or Parapet required Type LB or LR Access Fitting, " Min. whichever applicable. * Light Fixture Swivel Box GCL OR RCL MOUNTING DETAILS (SCHEMATIC) VIEW A-A (Traffic Railing - 32" F Shape shown, other railings similar) 32" F-Shape Traffic Railing (shown) * Supplied by Light Fixture Manufacturer other railings or Parapet similar A A EJB Chain Flexible Conduit 2" Conduits or Parapet Service Traffic Railing C: \d\projects\standards\structures\current\ready4release\2014BOOK\21220-2of2. dgn B Mounting Box 2" Conduits Light Fixture " Min. Deck Access Fitting Bridge Swivel Box Bottom of Bridge Deck Bottom of Bridge Deck Service Girder Chain Service Chain Install Light Fixture so as to ensure visibility from an approaching vessel. 2" sm 970re nominal Bottom of Girder RCL or GCL 8: 00: 01 PM RCL or GCL B GCL OR RCL MOUNTING DETAILS (SCHEMATIC) ELEVATION VIEW RELATIVE TO SUPERSTRUCTURES LAST REVISION 07/01/13 REVISIO N 6/24/2013 (Traffic Railing (32" F Shape) shown, other railings similar) SECTION B-B TYPICAL POSITION OF RCL OR GCL DESCRIPTION: INDEX FDOT 2014 NAVIGATION LIGHT SYSTEM DETAILS DESIGN STANDARDS (FIXED BRIDGES) NO. 21220 SHEET NO. 2 of 2