Comments
Description
Transcript
Anchor Flange Calculation
PREPARED: Anchor Flange Calculation P.G.A.Engineering CHECKED: APPROVED: 30/06/2009 DATE: This calculation is according to ASME VIII Div.1 App.2 Outside Diameter of Pipe Schedula Number Pipe Material 27 6 131 Design Pression Test Pression Installation Temperature Maximum Temperature Minimum Temperature Test Temperature PTEST TINST TMAX TMIN TTEST 69,8 105 30 155 70 20 3 3 1 2 2 1 Corrosion Allowance Axial Load Bendig Moment c FX MX 0,0 1500,0 0,0 1 P Types of Flange Exthernal Load Evaluation Method Size of Flange Flange Material 1 Type of Conglomerate 1 3 132 CALCULATION DESCRIPTION Outside Diameter of Pipe Pipe Wall Thickness Pipe Inside Diameter Corrosion Allowance Design Pressure Design Pressure at Test Temperature Equivalent Pressure Installation Temperature Maximum Temperature Minimum Temperature Test Temperature Axial Load Bending Moment Allowable Pipe Stress at Operating Condition Allowable Pipe Stress at Test Temperature Allowable Flange Stress at Operating Condition Allowable Flange Stress at Test Temperature Allowable Bearing Stress Modulus od Elasticity at Operaing Condition Modulus od Elasticity at Test Temperature Mean Coefficient of Thermal Expansion at Operaing Condition Mean Coefficient of Thermal Expansion at Test Temperature DEF. INPUT DN t d c P PTEST Peq TINST TMAX TMIN TTEST FX MX SP,OP SP,TEST SAF,OP SAF,TEST SB E ETEST CT CTTEST Imperial Unit of Values Measure 30,000 in 0,625 in 28,750 in 0,000 in 1017 psi 1519 psi 5 psi 86 °F 155 °F 70 °F 68 °F 3306,9336 lb 0 in lb 25700 psi 65000 psi 25700 psi 65000 psi 4714 psi 2,90E+07 psi 3,02E+07 psi 6,61E-06 in/in/°F 6,40E-06 in/in/°F Metric Values 762,00 15,88 730,24 0 7,02 10,47 0,04 30 68 21 20 14710 0 177 448 177 448 32,5 200240 208270 1,19E-05 1,15E-05 Unit of Measure mm mm mm mm MPa MPa MPa °C °C °C °C N Nm MPa MPa MPa MPa MPa MPa MPa mm/mm/°C mm/mm/°C P.G.A. Engineering di Provini Gabriele - Via Emilia Parmense, 42 - 29010 Fontana Fredda di Cadeo (PC) Tel./Fax: +39 0523 072430 - E-mail [email protected] - Web: http://www.pgaengineering.it PREPARED: Anchor Flange Calculation P.G.A.Engineering CHECKED: APPROVED: 30/06/2009 DATE: This calculation is according to ASME VIII Div.1 App.2 DESCRIPTION DEF. Imperial Unit of Values Measure FLANGE DIAMENSION A 38,380 DF 32,120 Hub Diameter Beginning of Chamfer Welding Neck C 30,000 Inside Diameter B 28,750 Thickness of Hub at Back of Flange g1 1,685 Thickness of Hub at Small End g0 0,625 Flange Thickness t 3,440 Hub Lenght h 3,880 OUTPUT Pipe Area AP 57,70 WMIN Minimum Design Load Reatings 3500 WI Design Load Reatings at Maximum Temperature 1.424.724 WD Design Load Reatings at Minimum Temperature 177.212 WTEST Design Load Reatings at Test Temperature 785.011 Design Load Reatings W 1.424.724 Diameter of Load Circle N 34,36116213 Hg Radial Distance from Load and Reaction 2,180581067 Moment Acting Upon the Flange M 3.106.727 MTEST Moment Acting Upon the Flange 1.711.781 Outside Diameter of Flange Diameter of Hub Metric Values Unit of Measure in in in in in in in in 974,852 815,848 762 730,24 42,804 15,88 87,376 98,552 mm mm mm mm mm mm mm mm in2 lb lb lb lb lb in in lb in lb in 37223 15569 6337490 788280 3491905 6337490 872,77 55,39 544.071 299.779 mm2 N N N N N mm mm Nm Nm VERIFICATION Calculated psi MPa Allowed psi MPa SH Longitudinal Stress in Hub at Op. Cond. 31.207 215,16 38.550 265,79 VERO SR Longitudinal Stress in Flange at Op. Cond. 13.271 91,50 25.700 177,20 VERO ST Tangentinal Stress in Flange at Op. Cond. 15.574 107,38 25.700 177,20 VERO (SH+SR)/2 at Op. Cond. 22.239 153,33 25.700 177,20 VERO (SH+ST)/2 at Op. Cond. 23.390 161,27 25.700 177,20 VERO 4.104 3.166 28,30 21,83 25.700 4.714 177,20 32,50 VERO VERO SH,TEST Longitudinal Stress in Hub at Test Temp. 17.195 118,55 97.500 672,24 VERO SR,TEST Longitudinal Stress in Flange at Test Temp. 7.240 49,92 65.000 448,16 VERO ST,TEST Tangentinal Stress in Flange at Test Temp. Description SS Shear Stress at Op. Cond. SB Bearing Stress at Op. Cond. CHECK 8.837 60,93 65.000 448,16 VERO (SH,TEST+SR,TEST)/2 at Test Temp. 12.218 84,24 65.000 448,16 VERO (SH,TEST+ST,TEST)/2 at Test Temp. 13.016 89,74 65.000 448,16 VERO 2.261 1.744 15,59 12,03 65.000 4.714 448,16 32,50 VERO VERO SS Shear Stress at Test Temp. SB Bearing Stress at Test Temp. P.G.A. Engineering di Provini Gabriele - Via Emilia Parmense, 42 - 29010 Fontana Fredda di Cadeo (PC) Tel./Fax: +39 0523 072430 - E-mail [email protected] - Web: http://www.pgaengineering.it PREPARED: Anchor Flange Calculation P.G.A.Engineering CHECKED: APPROVED: 30/06/2009 DATE: This calculation is according to ASME VIII Div.1 App.2 imperial unit metric unit A= 38,38 974,85 DF= 32,12 815,85 C= 30 762,00 B= 28,75 730,24 H= 3,880 98,55 T= 3,440 87,38 H= 3,880 98,55 g0= 0,625 15,88 g1= 1,685 42,80 Imperial DESCRIPTION DEF. Values FLANGE DIAMENSION Outside Diameter of Flange A 38,380 Diameter of Hub DF 32,120 Hub Diameter Beginning of Chamfer Welding Neck C 30,000 Inside Diameter B 28,750 Thickness of Hub at Back of Flange g1 1,685 Thickness of Hub at Small End g0 0,625 Flange Thickness t 3,440 Hub Lenght h 3,880 Metric Unit of Measure in in in in in in in in Values 974,852 815,848 762 730,24 42,804 15,88 87,376 98,552 Unit of Measure mm mm mm mm mm mm mm mm P.G.A. Engineering di Provini Gabriele - Via Emilia Parmense, 42 - 29010 Fontana Fredda di Cadeo (PC) Tel./Fax: +39 0523 072430 - E-mail [email protected] - Web: http://www.pgaengineering.it