Comments
Transcript
B115 - B145 - B180 - B250 - B310 - B400 - B500
13700720 I CONTATTORI I010 I GB D CN 12 13 GB CONTACTORS LOVATO ELECTRIC S.P.A. D 24020 GORLE (BERGAMO) ITALIA VIA DON E. MAZZA, 12 TEL. 035 4282111 TELEFAX (Nazionale): 035 4282200 TELEFAX (International): +39 035 4282400 E-mail [email protected] Web www.LovatoElectric.com SCHÜTZE CN B115 - B145 - B180 - B250 - B310 - B400 - B500 - B630 - B630 1000 Ith AC1 ≤40°C ≤55°C ≤70°C [A] [A] [A] [mm2] Ie AC3 [A] 230V [kW] 400V [kW] 415V [kW] 440V [kW] 500V [kW] 690V [kW] 1000V [kW] B115 B145 B180 B250 B310 160 250 275 350 450 150 235 250 300 370 110 190 200 250 300 110 150 185 265 320 33 46 57 83 100 61 80 100 140 170 66 88 108 155 188 70 93 115 164 200 80 100 123 176 213 100 120 144 212 256 63 75 103 156 180 B400 550 430 360 420 130 225 247 263 271 352 208 B500 700 550 500 520 156 290 306 328 367 416 312 B630 800 640 540 630 198 335 368 368 368 440 368 B630 1000 1000 850 700 –– –– –– –– –– –– –– –– UL/CSA General (purpose) use [A] 160 250 275 350 450 550 700 800 1000 70 120 150 185 2x150 2 30x5 2x185 2 25x8 2x240 2 50x5 2x240 2 50x5 2 60x5 UL/CSA Fuse class Type / [A] B115 RK5 / 500 B145 RK5 / 500 B180 RK5 / 500 B250 L / 800 B310 L / 800 B400 L / 800 B500 L / 1200 B630 L / 1500 B630 1000 L / 1500 No UL/CSA ratings for indication and reference purposes only. UL/CSA Short circuit current [kA] 5 5 10 18 18 18 18 18 18 UL/CSA Three phase [HP] 200-208V 30 50 60 75 100 125 150 200 240V 480V 40 75 50 100 75 150 100 200 125 250 150 350 200 400 250 500 For resistive duty only. 600V 100 125 150 250 300 400 450 500 13700720 I010 I GB D CN 12 13 gG 200A gG 315A gG315A gG 400A gG 500A gG 500A gG 800A gG 1000A gG 1000A B115 B145 B180 B250 B310 B400 B500 B630 B630 1000 gG 160A gG 200A gG 250A gG 315A gG 400A gG 500A gG 630A aM 100A aM 125A aM 160A aM 200A aM 250A aM 315A aM 500A B115 B145 B180 B115 B145 B180 B115 B145 B180 B145 B180 B250 B310 B400 B180 B250 B310 B400 B250 B310 B400 B250 B310 B400 60-100A 75-125A 90-150A 120-200A 150-250A 180-300A 250-420A Application note: The input electronic circuit of the contactor coil is designed and tested according to IEEEC 62.41 and will withstand a 10kV impulse (1.2/50μs) with 50 Joule energy. For higher values the use of a step-down voltage transformer is recommended. B115-B145-B180 B250-B310-B400 B500-B630 B630 1000 160VA ® 2 200VA Us (0.8-1.1) V = (50/60Hz-DC) VA=W VA=W A VA=W VA=W A 24 48 60 110-125 220-240 380-415 440-460 10 10 10 10 10 10 10 4 2 2 1 0.5 0.5 0.5 –– 400 400 400 400 400 400 –– 18 18 18 18 18 18 –– 4 2 1 0.5 0.5 0.5 300 300 300 300 300 300 300 180° NO! ® 3 I010 I GB D CN 12 13 13700720 13700720 I010 I GB D CN 12 13 B115 B145-B180 B250 B310-B400 11 G360 11 G361 11 G362 11 G363 11 G370 6.3x0.8 2/2.8x0.8 11 BA126 2 4mm2 T = 1 Nm / 8.9lbin 11 G371 B500 B500 4 B630 B630 4 B115-B145-B180 11 BA1595 B250-B310-B400 11 BA1721 B500-B630 11 BA1846 11 G527 11 G528 11 G529 11 G530 B115 4-B145 4-B180 4 B250 4-B310 4-B400 4 11 BA1594 11 BA1720 B500 4-B630 4 11 BA1845 ® 4 13700720 11 G350 11 G354 I010 I GB D CN 12 13 B115 B145 B180 B250 B310 B400 B500 B630 B630 1000 11 G350 11 G350 11 G350 11 G350 11 G354 11 G354 or 11 G354 G350 G350 41 01 42 74 74 14 82 114 22 61 93 121 121 33 62 94 122 122 121 22 114 21 113 94 93 82 54 81 114 02 113 42 Ø 7mm 01 41 81 74 74 13 53 13 OR 53 82 14 121 61 14 73 73 G354 62 OR 122 54 34 33 61 122 21 82 34 22 81 62 113 114 62 OR 22 113 21 61 81 54 21 02 53 OR 73 13 54 73 13 53 G354 14 G354 11 G354 G354 G350 G350 T max 1 Nm / 8.9lbin 6.3x0.8 2/2.8x0.8 4mm2 11 G370 T = 0.5 Nm ® 5 13700720 ...11 ...20 ...02 53 61 53 63 51 61 54 62 54 64 52 62 I010 I GB D CN 12 13 BFX10... ...03 ...12 ...30 ...21 51 61 71 53 61 71 53 63 73 53 61 73 52 62 72 54 62 72 54 64 74 54 62 74 11 G484 G485 G486-G487 57 65 67 55 58 66 68 56 11 G485 11 G486 11 G487 11 G371 11 G358 ® 6 [mm] B115-B145-B180 B115 4-B145 4-B180 4 B250-B310-B400 B250 4-B310 4-B400 4 B500-B630-B630 1000 B500 4-B630 4-B630 1000 4 I010 I GB D CN 12 13 13700720 11 G355 KM1 A B 90 130 110 157.5 150 215 150 150 180 180 230 230 D F 45 M6 45 M6 50 M8 50 M8 60 M10 60 M10 KM2 T = 3 Nm / 26.6lbin KM1 KM1 KM1 KM2 ® 7 13700720 11 G356 ... [mm] I010 I GB D CN 12 13 B115-B145-B180 B115 4-B145 4-B180 4 B250-B310-B400 B250 4-B310 4-B400 4 B500-B630-B630 1000 B500 4-B630 4-B630 1000 4 A B F 90 130 110 157.5 150 215 150 150 180 180 230 230 M6 M6 M8 M8 M10 M10 2 KM1 1 3 KM2 D 11 G356 1 11 G356 2 11 G356 3 11 G356 4 11 G356 5 11 G356 6 225-265 (B115-180) 265-305 (B115-400) 305-345 (B115-630) 345-385 (B115-630) 390-425 (B115-630) 470-500 (B115-630 1000) KM1 4 6 7 8 5 KM2 ® 8 13700720 I010 I GB D CN 12 13 B115 4-B45 4-B180 4 B250 4-B310 4-B400 4 B500 4-B630 4-B630 1000 4 B115-B45-B180 B250-B310-B400 B500-B630-B630 1000 11 BA1589 11 BA1714 11 BA1839 11 BA1588 11 BA1713 11 BA1838 4 3 2 T = 0.5 Nm / 4.4lbin 1 B115 B145 B180 B250 B310 B400 B500 B630 B630 1000 11 G380 11 G381 11 G382 11 G383 11 G385 11 G384 11 G525 11 G526 11 G537 B115 4 B145 4 B180 4 B250 4 B310 4 B400 4 B500 4 B630 4 B630 1000 4 11 G380 4 11 G381 4 11 G382 4 11 G383 4 11 G385 4 11 G384 4 11 G525 4 11 G526 4 11 G537 4 ® 9 13700720 I010 I GB D CN 12 13 B115 - B145 - B180 - B250 - B310 - B400 T = 3.5Nm / 31lbin B500 - B630 - B630 1000 ® 10 13700720 I010 I GB D CN 12 13 Us [V] B500-B630 B630 1000 B115-B145-B180 B250-B310-B400 24 48 60 110-125 220-240 380-415 440-480 11 BA1546 24 11 BA1546 48 11 BA1546 60 11 BA1546 110 11 BA1546 220 11 BA1546 380 11 BA1546 440 11 BA1671 24 11 BA1671 48 11 BA1671 60 11 BA1671 110 11 BA1671 220 11 BA1671 380 11 BA1671 440 –– 11 BA1796 48 11 BA1796 60 11 BA1796 110 11 BA1796 220 11 BA1796 380 11 BA1796 440 B115 B145 B180 B250 B310 B400 B500 B630 B630 1000 11 BA1575 1 11 BA1700 1 11 BA1799 3 2 1 Us [V] 24 48 60 110-125 220-240 380-415 440-480 B115-B145-B180 B250-B310-B400 11 BA11574 24 11 BA11574 48 11 BA11574 60 11 BA11574 110 11 BA11574 220 11 BA11574 380 11 BA11574 440 11 B 1699 24 11 BA1699 48 11 BA1699 60 11 BA1699 110 11 BA1699 220 11 BA1699 380 11 BA1699 440 2 3 B500-B630 B630 1000 –– 11 BA1800 48 11 BA1800 60 11 BA1800 110 11 BA1800 220 11 BA1800 380 11 BA1800 440 B115-B145-B180 B250-B310-B400 B500-B630-B630 1000 11 BA1553 11 BA1678 11 BA1803 ® 11 322 B115 B145 B180 20 40 40 A 90 120 A M6 M8 M8 40 M6 40 B B 15 20 20 M8 150 40 20 40 A 130 40 160 40 B M8 M6 40 [mm] 56.5 114 166 184 4 96 95 98 97 [A] 60-100 75-125 90-150 120-200 150-250 160-300 250-420 3 4 1 2 RF200 100 RF200 125 RF200 150 RF200 200 RF420 250 RF420 300 RF420 420 6 5 2 T1 L1 1 4 T2 L2 3 6 T3 L3 5 11 G372 RF200 ¥ B115-B145-B180 11 G375 RF420 ¥ B145-B180 STOP B115 - B145 - B180 RESET ® TEST 12 170 150 120 170 150 322 I010 I GB D CN 12 13 13700720 ® 13 25 47.5 47.5 M10X35 110 145 47.5 M8 47.5 25 0 M1 25 47.5 47.5 157.5 47.5 192.5 47.5 25 0 M1 M8 47.5 56.8 166 144 225 5 I010 I GB D CN 12 13 97 98 95 96 [A] 60-100 75-125 90-150 120-200 150-250 160-300 250-420 3 4 1 2 RF200 100 RF200 125 RF200 150 RF200 200 RF420 250 RF420 300 RF420 420 6 5 2 T1 L1 1 4 T2 L2 3 6 T3 L3 5 11 G373 RF200 ¥ B250-B310-B400 11 G376 RF400 ¥ B250-B310-B400 STOP 370 [mm] RESET B250 - B310 - B400 TEST 204 179 140 204 180 370 180 13700720 ® B500 B630 A 65 B500 - B630 270 14 150 A M10 M12 B 192 65 B 35 40 M10 C 265 270 A [mm] 65 B 215 M10 257 65 65 177.5 263 6 170 230 C 230 270 230 I010 I GB D CN 01 12 13700720 ® 15 65 150 194 65 M12 476 60 476 60 230 [mm] q 65 p 215 259 65 65 M12 230 B630 1000 147.2 207.6 263 170 230 270 I010 I GB D CN 01 12 13700720 [mm] G355 15 14.5 111.5 60.6 I010 I GB D CN 01 12 13700720 G350 - G354 A G356 1 = 225-265 G356 2 = 265-305 G356 3 = 305-345 G356... 29.8 G356 4 = 345-385 G356 5 = 390-425 G356 6 = 470-500 G360 - G361 102 50 A 68 31.9 G363 96.7 35.2 G358 30 ® 16 127.5 56.5 [mm] 250 167 83 117 117 BA1594 - BA1720 - BA1845 Ø13 BA1594 BA1720 BA1845 A 45 53 –– B 32 50 –– C Ø14 Ø18 –– D 5 5 10 65 20 80 40 B D C G495 B115 - B145 - B180 B250 - B400 B500 - B630 A 221 255 300 A 13700720 G528 - G530 185 A I010 I GB D CN 01 12 G527 - G529 E1 E2 85 ® 17 13700720 I010 I GB D CN 12 13 B115 L 00 - B145 L 00 - B180 L 00 - B250 L 00 - B400 L 00 - B500 L 00 - B630 L 00 B115 4 L 00 - B145 4 L 00 - B180 4 L 00 - B250 4 L 00 - B400 4 L 00 - B500 4 L 00 - B630 4 L 00 A1 E1 E2 03 04 91 92 A2 E1 U1 E2 U2 A1 A2 E1 E2 03 04 91 92 A1 A2 E1 E2 03 04 91 92 A1 4 ... 8kg A2 ® 18 E1 E2 03 04 91 92 ATTENZIONE!! WARNING!! ACHTUNG!! ATTENTION!! ATENCION!! 13700720 [mm] I010 I GB D CN 12 13 B115 - B145 - B180 B115 = 10mm B145 = 13mm B180 = 13mm B115 T = 10Nm / 7.4lbft B145 T = 18Nm / 13.3lbft B180 T = 18Nm / 13.3lbft B250 - B310 - B400 [mm] B250 = 17mm B310 = 17mm B400 = 17mm B250 T = 35Nm / 25.8lbft B310 T = 35Nm / 25.8lbft B400 T = 35Nm / 25.8lbft B500 - B630 - B630 1000 [mm] B500 = 17mm B630 = 19mm B630 1000 = 19mm B500 T = 35Nm / 25.8lbft B630 T = 55Nm / 40.6lbft B630 1000 T = 55Nm / 40.6lbft ® 19 13700720 I010 I GB D CN 12 13 ATTENZIONE! Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative impiantistiche, allo scopo di evitare danni a persone o cose. I prodotti descritti in questo documento sono suscettibili in qualsiasi momento di evoluzioni o modifiche. Le descrizioni ed i dati a catalogo non possono pertanto avere alcun valore contrattuale. WARNING! This equipment must be installed by trained personnel, complying to current standards, to avoid damages or safety hazards. Products illustrated herein are subject to alterations and changes without prior notice. Technical data and descriptions in the documentation are accurate to the best of our knowledge, but no liabilities for errors, omissions, or contingencies arising therefrom are accepted. ACHTUNG!! Um Personen- und Sachschaden zu vermeiden, darf diese Gei nur von fachkundingem Personal, unter Berücksichtigung der jeweils geltenden Vorschriften, installiert werden. Die in diesem Katalog gezeigten Produkte können jederzeit ohne Vorankündigung geändert werden. Technische Daten und Beschreibungen sind richtig und wurden nach bestem Wissen und Gewissen erstellt. ®