FPL-10QCC Head

by user

on
95

views

Report

Comments

Transcript

FPL-10QCC Head
FPL10 QCC (Quick Color Change) Head
Two components high pressure
mixing head designed for the quick
change of a third component (color
or any other additive to be injected
directly inside the mixing chamber).
The third stream is recycling through
a dedicated nozzle and, as a
consequence, the third component
can be changed without flushing
shots to clean the inside of the head.
Recycling phase
Min output of poly stream ( cc/sec )
Min output of iso stream ( cc/sec )
rd
Min output of the 3 stream ( cc/sec )
20
20
5
Total min output
50
Max output of poly stream ( cc/sec )
Max output of iso stream ( cc/sec )
Max output of the 3 rd stream ( cc/sec )
Total max output
170
170
50/80 (*)
260
Poly and Iso values are calculated in cc/sec considering component viscosity
< 1000 cps without filler and 150 bar pressure.
(*) 50 cc/sec for viscosity < 3000 cps and 80 cc/sec for viscosity
< 1000 cps at 100 bar pressure
POLYURETHANE TECHNOLOGY
FPL10QCC - MH13
Pouring phase
Cannon Communication 02/2011
FPL10 QCC
A
FPL10-QCC
B
C
D
E
F
G
H
I
WEIGHT
43.5 mm 320 mm 40 mm 15 mm 158 mm 151.5 mm 111.5 mm 24 mm 83 mm
11.5 Kg
All data are subject to variation without notification due to continuos technical/technological developments
Afros SpA
Via Galileo Ferraris, 65 - 21042 Caronno P.lla, (VA) Italy - Tel. +39 0296531 - www.afros.it
Afros
Division
Fly UP