LIGHT PEDESTAL NOTES: 1. The pedestal and junction slab are designed to resist the following working loads from the light pole applied at the top of the Pedestal: 6’-5" Min. (Pull Box Side) (See Note 9) Axial Deadload = Windload Moment about Transverse Axis (*) = 40.60 kip-ft Windload Moment about Longitudinal Axis (*) = 28.30 kip-ft Deadload Moment about Longitudinal Axis (*) = 1.690 kip-ft Maximum Shear = 1.380 kip Torsion about Pole Axis = 3.560 kip-ft (*) 4’-6" Min. (See Note 9) Varies (Transition to Varies (Transition to 1’-9" Thick Junction Slab) 1’-9" Thick Junction Slab) 1.560 kip - Axis refers to Bridge Axis. 2. See Index No. 21200 for anchor bolt design and notes. 3. The Contractor is responsible for ensuring the anchor bolt design is compatible with the light pole base plate. Modifications to the anchor bolt design must be signed and sealed by the Contractor’s Specialty Engineer and submitted to the Engineer for approval prior to construction. Junction Slab Junction Slab Length of 1’-6" Thick Junction Slab ~ 7’-6" 4. Install Anchor Bolts plumb. 5. For conduit, pull box and expansion/deflection fitting details, see Utility Conduit Detail Drawings. 6. 12 Bars 4J & 4M1 (Top & Bottom) @ 8"– The cost of anchor bolts, nuts, washers and anchor plates will be included in the Bid Price for Light Poles. Include the cost of all labor, concrete and reinforcing steel required for construction of the pedestals, pull boxes and miscellaneous hardware required for the completion of the electrical Bars 5B3 system in the Bid Price for either the Traffic Railing or Concrete Parapet that the pedestal is Field Cut Bars 4M2 as required to maintain clearance. Bars 4J 8. Anchor Bolt pattern orientation will be as shown. & 4M1 9. Slip Forming Method of construction requires the Engineer’s approval within the limits shown. 10. Reinforcing shown for light pole pedestals is in addition to typical reinforcing for C.I.P. Junction Slabs and Raised Sidewalks. 11. Work this Index with the following as appropriate: Index No. 6110 Index No. 6120 Index No. 6130 (See Note 5) Construction 2 ~ 2" Conduits Gutter Line (shown) or Front Face of Concrete Parapet 1’ -8" Joint 4G4 & 4G5 ( pairs) 12. For Estimated Quantities, see Sheet No. 3. »¿ Pul Spacing for Bars Bars 5B3 spaced @ 1’ -0" behind. 7. Traffic Railing or Concrete Parapet Bars 4M2 (See Note 7) Bars 4H 1 2" »¿ Light Anchor Bolt Circle 2" Cover (Typ.) 1’-1b " (See Note 8) Coping 9 1’ -1b " Bars 4G4 (pairs) C. I. P. Pedestal Bars 4G1 (pairs) 2’ -6" 1 ~ 1b " Conduit Bars 4G3 (pairs) (Typ.) 3 Sp. @ 6" Bars 4G2 (pairs) (Typ.) Bars 4G5 (pairs) 2 Sp. @ 6" 2 Sp. @ 6" 1’-1" Spacing for Bars 5" 5 Sp. @ 6" 5" 1’-1" 4G1, 4G2, 4G3 & 4M2 2’-6" 2’-6" 2’-6" »¿ Expansion Joi Junction Slab, Raised »¿ C.I.P. Pedestal & Lig 4’-6" Min. Sidewalk or Sidewalk PLAN VIEW (Junction Slab reinforcing not shown for clarity) (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) REVISIONS DATE BY 01/01/11 SJN DESCRIPTION DATE 2010 Interim Design Standard BY DESCRIPTION New Index No. & Title (Previously Index No. 5300, Sheet 16 of 19); Changed width of junction slab, Note 10 & "pilaster" to "pedestal". COPING MOUNTED LIGHT POLE PEDESTAL Interim Date Sheet No. 01/01/11 1 of 3 Index No. 6200 9’-0b" 1’-6b " 5’-0" 2’-6" 1’-4b " 1’-1b " C.I.P. Traffic Railing (32" F-Shape Shown, Other Traffic Railings Similar) Coping »¿ Light Gutter Line (shown) or Front Face of Concrete Parapet 1b " Conduit 2" Conduits Top of Junction Slab, Bars 5V2 @ 8" sp. Raised Sidewalk or Sidewalk (See Note 4) Top of C.I.P. Coping (See Note 6) (Const. Joint Required) Slope C.I.P. Pedestal Surface Shoulder or Riding Surface Roadway Pavement Longitudinally with Profile Grade 1 Bars 4G1 (pairs) " (pairs) Spacing Bars 4M1 4" Cover (Bottom) @ 8" sp. 2" Cover (Top & Sides) Bars 5B3 Bars 4H1 2’ -0" C. I. P. Pedestal 6" Bars 4G5 Recess (Typ.) » ¿1 0˘ " 6" Bars 5B3 »¿ Varie s ( 9 Elevation Bars 4H2 ( See Note 2) 1’ -9" Top of Coping Bars 4G4 (pairs) M ax. , 3" M in. ) " ( Se e No t e4 ) » ¿ 1 Bars 5S (See Note 6) Sl o p e Va r i e s Construction Bars 4M2 @ 6" sp. Joint Permitted Bars 4G4 (pairs) (Typ.) Bars 4J @ 8"– sp. (tie to Alternate Bars 4A 1" Preformed Joint Filler (Top) in Junction Slab) (See Note 3) 3" Min. Retaining Wall & Expanded Polystyrene shown (Type Varies) hatched ( b " Each Side) 4 Sp. @ 1’-0" = 4’-0" Spacing Smooth or Bars 5B3 See 6" Textured Face of Retaining Wall Note 5 TYPICAL SECTION AT LIGHT POLE PEDESTAL (Traffic Railing Shown, Concrete Parapet Similar) (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) NOTES: 1. Provide Concrete Class to match adjacent coping. 2. For junction slabs, increase the 1’-0" depth dimension to 1’-9". For sidewalks see Index No. 6130 for C.I.P. Coping, but increase 6" depth dimension to 1’-6". The minimum length of the Junction Slabs, Raised sidewalks and Sidewalks is 30’-0", measured along the Gutter Line. 3. Bars 4J are only required when pedestals are behind a Traffic Railing. 4. Match the slope of the adjoining junction slab and shoulder or roadway pavement, raised sidewalk or sidewalk. 5. Actual width varies depending on type of Retaining Wall used. 6. See Index No. 6110 for Bars 5V2 and 5S. REVISIONS DATE BY 01/01/11 SJN DESCRIPTION DATE 2010 Interim Design Standard BY DESCRIPTION New Index No. & Title (Previously Index No. 5300, Sheet 17 of 19). Changed Junction Slab. COPING MOUNTED LIGHT POLE PEDESTAL Interim Date Sheet No. 01/01/11 2 of 3 Index No. 6200 REINFORCING STEEL BENDING DIAGRAMS - LIGHT POLE PEDESTAL 5’-0" Max. (Left or Right) 5 7 7’-2" G1 4 16 5’-8" G2 4 4 4’-8" See Detail "A" 2" Conduit Bars 4G1 Bars 4G2 (pairs) (Typ.) Top of recess 45 (Typ.) G3 4 4 4’-2" G4 4 6 8’-10" G5 4 4 7’-4" H1 4 3 9’-8" H2 4 2 13’-8" J 4 12 6’-0" M1 4 12 5’-10" M2 4 10 3’-8" 2’ -0" 2’-7" 2’-7" Varies (Transition to 2’-7" 2’-7" 4G2 1’-9" 4G3 3’-8" 4G4 2’-11" 4G5 (Junction Slab Reinforcing & Bars 4J not Shown for Clarity) (Traffic Railing Shown, Concrete Parapet Similar) (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) 1b " Conduit 4M1 5’-0" 4M2 2’-2" 4M 2 2’-0" 1’ -5b " 4G1 4G4 & 4G5 ELEVATION VIEW 2’-6" 4G1, 4G2 & 4G3 Junction Slab 4M 1 BAR 4H1 1’-9" Thick Junction Slab) 7’-6" (Length of 1’-6" Thick Junction Slab) 2’-4" 10" 2’-6" 7b " 2’-6" 1’-9" Thick Junction Slab) Junction Slab 2’-4" BAR 4H2 1’ -6" 2’-6" BARS 5B3 & 4J (See Note 1) 2" Cover (Top & sides) Varies (Transition to 3" – Bars 4M2 (pairs) (Typ.) 4" Cover (Bottom) Bottom of Thickened Junction Slab 2b " Bars 4H1 Bars 4G4 Bottom of C.I.P. Pedestal @ Bars 4G5 (pairs) (Typ.) Varies Junction Slab 3 sp. (pairs) Bars 4G3 (pairs) (Typ.) & Bottom of 6" Bars 4H2 6’-0" 2’ -7" 1b " Conduit C. I. P. Pedestal Spacing Bars 4H »¿ Pul 4J 2’ -0" B3 2’ -7" SIZE 7’-2" 2’ -7" NO. REQD. LENGTH MARK »¿and Light 5B3 2’ -0" Top of Traffic Railing »¿ C.I.P. Pede 2’ -7" BILL OF REINFORCING STEEL BARS 4G1, 4G2, 4G3, Light Pole Wire Screen NOTES: (See Spec. 649-6) 1. Field Cut Bars 4M2 as required to maintain minimum cover. 2" Conduit Light Pole Base 4G4 & 4G5 will not exceed anchor bolt diameter. Leveling Nut (See Note 2) REINFORCING STEEL NOTES: Diam eter M axim um 1 ~ Bolt Plate (Level) BAR 4M1 & 4M2 2. Maximum clearance between leveling nut and top of pedestal 1. All bar dimensions in the bending diagrams are out to out. 2. Lap splices for Bars 4G1, 4G2 & 4G3 will be a minimum of 1’-4". Lap splices for Bars 4G4 & 4G5 will be a minimum of 1’-8". 3. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded Wire Reinforcement will conform to ASTM A 497. ESTIMATED QUANTITIES ITEM UNIT QUANTITY Concrete (Pedestal) CY 0.926 Concrete (Thickened Junction Slab) CY 1.222 Reinforcing Steel Lb. 349 Washer Slope C.I.P. Pedestal (Typ.) Surface Longitudinally with Profile Grade Anchor Plate Anchor Bolts (The quantities above are for one C.I.P. Light Pole Pedestal. The concrete quantity for the thickened junction slab is based on a 6" increase in thickness and a 5" wide retaining wall panel. Adjust thickened concrete quantity as required for raised sidewalks and sidewalks.) DETAIL "A" REVISIONS DATE BY DESCRIPTION 01/01/11 SJN New Index Number (Previously Index No. 5300, Sheet 18 of 19); Changed number of Bars 5B3 & 4J, length of Bars 4M1 and ESTIMATED QUANITITIES. DATE 2010 Interim Design Standard BY DESCRIPTION COPING MOUNTED LIGHT POLE PEDESTAL Interim Date Sheet No. 01/01/11 3 of 3 Index No. 6200