Comments
Description
Transcript
FDOT DESIGN STANDARDS FY 2012/2013 1
Bars G2 (evenly spaced) W Backfill A Bars F 4" Min. Bars A (F.S.) Front Face of Wall Bars A (paired with Bars J) Wall Cover (Typ.) H eight H eight 1 Bars F (N.S.) Bars G2 (evenly spaced) Slope NOTE: Backwall See Plans for Retaining Wall Data Bars J & K Bars K (F.S.) D soil (1’-0" Min.) Const. Jt. L Bars H toe Footing Cover (Typ.) Bars J (F.S.) D D Bars M (N.S.) *D key C: \d\projects\standards\structures\current\ready4release\2012book_draft\06010-1of2. dgn *D key A Bars Z (N.S.) Bars H Bars G1 Bars G1 (Showing Near Side) Bars Z (Showing Far Side) L toe Footing Cover (bottom only) *L key Bars M (paired with Bars F) L foot VIEW A-A (Shear key shown dashed) * Shear Key is required only when specified by the Engineer TYPICAL SECTION NOTES DESIGN SPECIFICATIONS: BENDING DIAGRAM Design according to FDOT Structures Manual (current edition). MATERIALS: Total Length All reinforcing steel shall conform to ASTM A615 Grade 60. 1’-0" Lap Splice (Typ.) SURFACE FINISH: A Class 5 Applied Finish Coating shall be applied to the top of the wall and the exposed face above ground line. ARCHITECTURAL SURFACE TEXTURES: BARS G1 Alternate Architectural Surface Textures may be substituted for the Striated Pattern shown when approved by the Engineer. Concrete required for Architectural Surface Textures is not included in the quantities. 1 TRAFFIC RAILING BARRIER: rd960rh and Barrier Open Joints shall align. A If there is a Traffic Railing Barrier on the wall, Wall Joints and Barrier V-Grooves shall align and Wall Expansion Joints Slope Backwall A FOUNDATION: Prepare the soil below the footing in accordance with the requirements for spread footings in Specification 90 Section 455. 9: 34: 41 AM PAYMENT: All Retaining Wall costs, including all miscellaneous costs, shall be paid for at the unit contract price for B B either Class II, III or IV Concrete (Retaining Walls) (CY) and Reinforcing Steel (Retaining Walls) (lbs.). Retaining Wall quantities shall not include concrete nor reinforcing steel for Traffic Railings/Junction Slab. 12/30/2011 Traffic Railing/Junction Slab shall be paid for under Concrete Traffic Railing Barrier with Junction Slab. BARS J & K BARS M NOTE: LAST REVISION 01/01/11 REVISIO N All bar dimensions are out-to-out DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 C-I-P CANTILEVER RETAINING WALL NO. 6010 SHEET NO. 1 **Wall joint spacing 25 ft. maximum. At minimum, every fourth wall joint to be an expansion joint. **Wall Joint Spacing W »¿˘" V-Groove across top and See Plans for actual wall joint spacing »¿˘" x ˘" chamfers ( front face of wall at joint (Typ.). and expansion joint location. Extend V-Groove down back of wall 6" to 6" min. below ground. shall receive a Class 5 6" All exposed wall surfaces (see ’V-Groove Detail’) A Applied Finish Coating »¿˘" V-Gr (see ’V-Groove Detail) Wall Joint B B A (required at footing step) Thickness of form liner (including striations) Ground Line 6" (keyway not required) consist of uniform vertical »¿˘" V-Gr 6" »¿grooves of ˘" t See ’Detail A’ At Contractor’s option, See ’Typical Backfill Detail’ 6" 1’-0" (see ’V-Groove depth and spacing Detail’) D 10 ft. max. spacing (Typ.) V (including striations) Striated Surface shall 3" PVC Drain Pipe at step Thickness of form liner Level (Typ.) D Top of Footing Const. Joint permitted Top of Footing SECTION A-A ( 2’ -0" M ax. ) 6" Striations may terminate at 6" min. below ground line Traffic Railing (Index No. 420, 32" F-Shape shown, see Plans Wall Joint Stem Offset (paired with for Traffic Railing type) Bars G1) Junction Slab (See Vertical Line Index Series 6100) Top of DETAIL A SECTION B-B Front Face CIP Wall of Wall -3" 9" 1’ 45 (Typ.) Stem Offset (in.) = H(Ft.)/16 H »¿ Wall Front Face » of Wall 6" 1 b" »¿˘" V-Groove (T 4" » Bars D @ 1’-0" 9 " » ¿ (see ’V-Groove Detail’) (Max. spacing) 4" STEM OFFSET VALUES » ¿* V-GROOVE DETAIL Front Face of Wall » ( for H < 20 Ft.) TRAFFIC RAILING/JUNCTION SLAB DETAIL »¿ Varies Backfill layers to be sloped both for 32" Vertical Shape Traffic Railing, see Index No. 423; transversely and longitudinally as for 42" Vertical Shape Traffic Railing, see Index No. 422) »¿ necessary to drain and prevent See Roadway Plans for Backfilling shall comply with drainage requirement FDOT Specifications. (field bend) TYPICAL CORNER JOINT DETAIL WALL JOINT DETAIL ponding during backfilling. Front Face of Wall 9" Bars D s ie r a V (32" F-Shape Shown, other Traffic Railings similar) (for 32" F-Shape Traffic Railing (as shown), see Index No. 420; Varies H eight Varies Stem as constructed " 4 *Key to stop at top of footing and 6" from top of wall. Joint across footing and top of wall to be straight line. 3" PVC Drain Pipe. Slope down b" from back to front of wall »¿ Wall Front Face and extend b" beyond both 1 b" of Wall front face and back face of wall. » ¿ C: \d\projects\standards\structures\current\ready4release\2012book_draft\06010-2of2. dgn Top of Coping Optional Shear Key Bars R FRONT ELEVATION » b" Preformed Joint Filler Bars D @ 1’-0" (Max. spacing) Excavation shall comply with » ¿* FDOT Specifications. Final Groundline. 4" rd960rh 1" Cl. Plastic sleeve » » shall be covered with 1.0 Place geotextile fabric, meeting requirements of FDOT Specification square foot of galvanized 985 and Type D-3 of Index No. 199, around the perimeter to »¿mesh with ˘" open prevent fill from washing out. 01/01/11 REVISIO N LAST »¿ 9" Geotextile fabric, 1’-0" wide and full height of fill, meeting requirements of Specification 985 and Type D-5 of Index No. 199. EXPANSION JOINT DETAIL Apply TYPICAL BACKFILL DETAIL REVISION Varies graded and placed to allow free drainage. 12/30/2011 9: 34: 41 AM Drain shall be continuous 1.5’ x 1.5’ clean, broken stone or gravel, Inside ends of weep holes an adhesive approved by the Engineer to the back of wall for attachment of fabric material. DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 C-I-P CANTILEVER RETAINING WALL NO. 6010 SHEET NO. 2 S lo p e V a a x r . 1 ie :1 s 8" (Typ.) HEIGHT 8" Varies 6" 3" Cl. 3 & DRAIN Concrete for Scheme 3 Junction Slab and Traffic Railing shall REQD. be Class II per Section 346, unless otherwise specified in the plans. 0.08 0.11 (0.20*) 0.03 3 (4*) No 2’ 0.14 0.20 (0.32*) 0.09 4 (5*) No 3’ 0.22 0.32 (0.47*) 0.29 5 (6*) Yes 3. Reinforcing steel shall be ASTM A615, Grade 40 or 60 ASTM A497 Deformed Welded Wire Reinforcement (WWR) may be substituted on an equal area basis. Do not increase bar/wire (Typ.) 4’ 0.32 0.47 (0.65*) 0.43 6 (7*) Yes 5’ 0.43 0.65 (0.85*) 0.60 7 (8*) Yes 4. When required, for adjunct guiderail see the plans, Index No. 870 or 880 as appropriate. For adjunct Type B 12 fence see Index No. 802. 5. Joint seal to be two layers of 30# smooth roofing paper ESTIMATED QUANTITIES NOTES: 6" ) p. Ty ( or Type D-5 geotextile fabric in accordance with Index No. 199. Mop all contact surfaces of concrete and roofing For Scheme 3 Junction Slab and Traffic Railing see the paper or geotextile fabric with cut-back asphalt. Stop referenced Design Standards for estimated quantities. Bars A & roofing paper or geotextile fabric 6" below top of wall). B @ 1’-6" 6. Provide a continuous 1’x1’ clean gravel or crushed rock * Quantity for 2’-0" Toe Depth in Scheme 2. Ctrs. (Max.) drain for wall heights 3 ft. and higher. Wrap drainage layer Weep as shown, with Type D-3 geotextile fabric in accordance Hole Depth) with Index No. 199. Provide 8"x8" galvanized mesh with ( Toe 4b" of 30# Smooth (LB.) spacing for Grade 60 reinforcing steel or WWR. Ground 1" Cl. Varies One layer General Note 5) 1’ -0" » ( Joint Seal, see » ¿ 9" M ax. »¿ STEEL 2. Concrete for Gravity Wall shall be Class NS per Section 347. provided at the max. spacings shown. ASTM A185 Smooth or Bar A Keyway Bar B 2 SCHEME as the reinforced concrete retaining wall. HOLES 1’ Varies 3" Cl. SCHEME 1 4b" Surface » SCHEME Joint Seal H eight ( 5’ -0" M ax. ) General Note 5) 1’ -0" ( Joint Seal, see 3" Cl. ( Typ. ) 9" M ax. 1’ -6" sp. Bars B @ ( 30’M ax. ) Bars A (Typ.) WEEP REINF. (FT.) (Typ.) W all Joints equally spaced CLASS NS CONCRETE (CY) concrete retaining walls, except walls of proprietary designs, shall have the same face texture and finish PER LINEAR FOOT OF WALL 3" »¿˘" Cha »¿ ˘" V- ESTIMATED QUANTITIES FOR WALL M Bars B GENERAL NOTES 1. Gravity walls constructed as extensions of reinforced »¿ Drainage Layer spacing (When Drainage Layer required). Locate minimum (See Note 6) 2’-0" clear of wall joints. Roofing Paper 7. 6" Cl. (– 2" Prepare Foundation Per Tolerance) Spec. 455 (Spread Footings) Cost of reinforcing steel, face texture, finish, joint seal, drain pipes, drainage layer, galvanized mesh and geotextile fabric to be included in the Contract Unit Price for Concrete Class NS, Gravity Wall. Cost of concrete for Junction Slab in Scheme 3, to be included in Contract Unit Price for Concrete KEYWAY & WALL JOINT DETAIL TYPICAL SECTION (TOP VIEW) Traffic Railing Barrier With Junction Slab. Adjunct railings or fences to be paid for separately. BILL OF REINFORCING STEEL Edge of paved shoulder 1:1b < Slopes = 1:1 1:6 < Slopes = 1:1b Edge of paved shoulder Slopes = 1:6 SIZE LENGTH A 4 As Reqd. B 4 As Reqd. Traffic Railing (Index No. 420, 32" F-Shape shown, see Plans 3’-6" = Offset < 7’-3" BAR BENDING DIAGRAM 3’-6" = Offset < 6’-6" 7’-3" Min. offset 3b" Scheme 3 Scheme 1 & 2 Live Load Limit 6’-6" Min. offset Live Load Limit (See Plans) with wall heights > 3’, then 2’-0" Min.) Slopes up to Max. 1:1 to Max. 1:1 1’-0" For Slopes = 1:1b 2’-0" For Slopes > 1:1b 5 12 H eight steeper than 1:2 Slopes up ( 5’M ax. ) (Except for slopes H eight 1’-0" Min. to SHW ( 5’M ax. ) Note 4 1’-0" Min. to SHW for Wall Height = 2’-0" 2’-0" Min. to SHW 9 H eight + Toe Depth - 9" See General Wall Joint spacing - 4" Junction Slab (See Top of (29’-8" Max.) Index Series 6100) Coping 1’ -3" when required H eight ( 5’M ax. ) Soil Reinforcement Note 4 BAR A 9 9" 12 for Wall Height > 2’-0" 1’-0" Min. . R See General H eight + Toe Depth - 2’ -0" Slopes = 1:6 or face of curb for Traffic Railing type) or face of curb 1:6 < Slopes = 1:1b 3’-6" Min. Offset MARK " 1 rd960rh C: \d\projects\standards\structures\current\ready4release\2012book_draft\06011-1of1. dgn (Typ.) 9: 34: 42 AM ˘" openings, at the inside end of the PVC Drain P Provide 2" PVC Drain Pipe (Sch. 40) at 10 ft. max. And PVC Drain 12 NOTES: to SHW BAR B 1. All bar dimensions are out to out. LAST REVISION 01/01/11 REVISIO N 12/30/2011 1’-0" 1’-0" For Wall Height = 2’-0" SCHEME 1 SCHEME 2 (No Traffic Loading Effects) (With Traffic Loading or Slopes > 1:1b) 2’-0" For Wall Height > 2’-0" SCHEME 3 must be a minimum of 1’-6". (With Traffic Railing) DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 2. Lap splices for Bars A C-I-P GRAVITY WALL NO. 6011 SHEET NO. 1 C-I-P Traffic Railing NOTES Limit of Class 5 Applied Finish Coating SPECIFICATIONS: 1. General Specifications: The Florida Department of Transportation "Standard Specifications for Road and Bridge Construction", Current Edition and Supplements as Amended. 2. Design Specifications: a. Florida Department of Transportation (FDOT) "Structures Design Guidelines", Current Edition. b. American Association of State Highway and Transportation Officials (AASHTO) "LRFD Bridge Design Specifications", Current Edition. c. AASHTO-AGC-ARTBA Task Force 27 (Ground Modification Techniques), "Insitu Soil Improvement Techniques", January 1990. 9. All exposed concrete surfaces will receive a Class 5 Applied Finish Coating C-I-P Junction Slab Top of in accordance with Specification Section 400. Refer to Typical Section on this sheet and the following notes for limits of applied finish: a. The inside, backside and top of Traffic Railings and Pedestrian/Bicycle Railings. Concrete Coping b. Exposed surfaces of coping on top of retaining wall. Other coatings, colors or textures will be applied as required in the Wall Control Drawings. Soil Reinforcement (Typ.) 10. For concrete facing panel surface treatment, see Wall Control Drawings. Extend surface treatment a minimum of 6" below final ground line. Surface treatment when DESIGN CRITERIA: retaining wall, unless a method to protect the structure, acceptable to both required (See Construction 1. Design is based on the assumption that the material contained within the the Engineer and Wall Company, is proposed and approved in writing. The Note 10) reinforced soil volume, methods of construction and quality of prefabricated portion of piles or drilled shafts extensions within the soil volume will be materials are in accordance with Specification Section 548 and Chapter 3 wrapped with polyethylene sheeting in accordance with Specification of the FDOT Structures Design Guidelines. Section 459. 12. A structural extension of the connection of the retaining wall panel to soil reinforcement will be used whenever necessary to avoid cutting or excessive skewing (greater than 15) of the soil reinforcement around obstructions of the Engineer of Record. 4. If there are manholes and/ or drop inlets present, design and analysis for both internal and external stability shall be considered. 1’-0" Min. 4’-0" Min. the factored bearing resistance of the foundation for that specific wall location. stability design, including foundation and slope stability, is the responsibility Limits of Soil Volume maximum factored bearing pressure shown for the wall does not exceed 3. The Wall Company is responsible for internal stability of the wall. External Proposed Final Ground Line (i.e., piles, pipes, manholes, drop inlets, etc.). 13. Steps in leveling pads will occur at MSE Wall panel interfaces. Panels will not cantilever more than 2" past the end of the upper tier leveling pad. Top of 14. The top of the leveling pad or footing will be 2’-0" minimum below final Leveling Pad ground line. 2’-0" Min. Elevation 15. Top of leveling pad elevations shown in the Wall Control Drawings are maximum SOIL PARAMETERS: elevations. The constructed leveling pad elevations may be deeper based on 1. See Wall Control Drawings for soil characteristics of foundation material to be the panel layout shown in the shop drawings. on the actual soil characteristics utilized at the site. Concrete Leveling Pad Concrete Facing Panels TYPICAL MSE RETAINING WALL SECTION than half the height of a standard panel. WITH A TRAFFIC RAILING 17. Work this Index with Index 6100 & 6200 Series. (Showing Limits of the Reinforced Soil Volume) MATERIALS: SHOP DRAWING REQUIREMENTS: 1. Concrete Class: See Wall Control Drawings. See Specification Section 548 for shop drawing requirements. 2. See Specification Section 548 for material requirements. 3. For additional material requirements see the Wall Company’s General Notes. 10’-0" min. C.I.P. Coping 12’-0" min. Precast Coping/Traffic Railing CONSTRUCTION: 1. Walls will be constructed in accordance with Specification Section 548 and the Wall Company’s instructions. 12" 2’-0" 2. For location and alignment of retaining walls, see Wall Control Drawings. Coping 3. If present, consider in design and analysis and locate manholes and drop Transition 6" Top of Coping inlets as shown on wall elevations. FDOT MSE RETAINING WALL CLASSIFICATION TABLE 6. It is the Contractor’s responsibility to determine the location of any Durability Requirements Coping needed during construction. 2’ -3" 5. The Contractor is responsible for controlling water during storm events as Coping and anticipated long term and differential settlements. 2’ -0" strip/mesh length, factored bearing resistance’s, minimum wall embedment Precast 4. Refer to Wall Control Drawings of individual walls for minimum reinforcement Applicable Concrete FDOT Wall Type * Other Allowable FDOT Wall Types Concrete Pozzolan Soil Cover Class Additions? Reinforcement (in.) for Panels ** Type 2A 2B 2C 2D 2E 2F guardrail posts behind retaining wall panels. Prior to placement of the top layer of soil reinforcement, individual reinforcing strips/mesh may be Type 2A 3" skewed (15 maximum) to avoid the post locations if authorized by b" Preformed the Engineer. No cutting of soil reinforcement is allowed unless shown Joint Filler rd960rh II No Metal Type 2B 2 IV No Metal 3 IV No Metal Yes Metal Provide Supplemental Type 2C the soil reinforcement due to installation of the guardrail will be repaired #4 Bar with 3" concrete Type 2D 3 IV by the Contractor at the Contractor’s expense. Repair method will be cover Type 2E 3 IV No Plastic Type 2F 3 IV Yes Plastic If existing or future structures, pipes, foundations or guardrail posts within the reinforced soil volume interfere with the normal placement of soil reinforcement and specific directions have not been provided on the ELEVATION VIEW OF * See Data Table in Contract Plans. COPING HEIGHT TRANSITION plans, the Contractor will notify the Engineer to determine what course of action shall be taken. 8. 2 on Shop Drawings and approved by the Engineer. Any damage done to approved by the Engineer. 7. 9: 34: 46 AM Interior Face of 16. The height of panels in the bottom course of MSE Walls must not be less C. I. P. C: \d\projects\standards\structures\current\ready4release\2012book_draft\06020-1of1. dgn used in the design of the wall system. 2. The Contractor will provide soil design parameters for backfill material based Roadway Pavement 6100) 11. Drive piles located within the soil volume prior to construction of the 2. It is the responsibility of the Engineer of Record to determine that the Shoulder or (See Index Series Coping Elevation (Railing Not Shown For Clarity) ** Silica fume, metakaolin or ultrafine fly ash. The Contractor is responsible for gradually displacing upper layer(s) of soil reinforcement downward (15 maximum from horizontal) to avoid cutting soil reinforcement and conflicts with paving and subgrade preparation. The Contractor’s attention is directed especially to situations where roadway 12/30/2011 superelevation and/or soil mixing are anticipated. REVISION 01/01/12 REVISIO N GENERAL NOTES AND DETAILS LAST DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 PERMANENT MSE RETAINING WALL SYSTEMS NO. 6020 SHEET NO. 1 NOTES SPECIFICATIONS: 1. General Specifications: The Florida Department of Transportation "Standard Specifications for Road and Bridge Construction", Current Edition and Supplements as Amended. Secondary Reinforcement 2. Design Specifications: Top of Wall a. Florida Department of Transportation (FDOT) "Structures Design as required Guidelines", Current Edition. b. American Association of State Highway and Transportation Officials (AASHTO) "LRFD Bridge Design Specifications", Current Edition. Primary Reinforcement c. AASHTO-AGC-ARTBA Task Force 27 (Ground Modification Techniques), "Insitu Soil Improvement Techniques", January 1990. Reinforced Fill DESIGN CRITERIA: 1. Design is based on the assumption that the material contained within the reinforced soil volume, methods of construction and quality of prefabricated Geotextile Wrap materials are in accordance with Specification Section 548 and FDOT Structures Design Guidelines Section 3.13.2. Wire Facing 2. It is the responsibility of the Engineer to determine that the factored Limits of or Basket Soil Volume bearing pressure shown for the wall does not exceed the factored bearing resistance of the foundation for that specific wall location. 3. The Wall Company is responsible for internal stability of the wall. External stability design, including foundation and slope stability, is the responsibility of the Engineer. 4"-0" Min. 4. If present, consider in design and analysis and locate manholes and drop inlets as shown on wall elevations. 1"-0" Min. Foundation Soil SOIL PARAMETERS: C: \d\projects\standards\structures\current\ready4release\2012book_draft\06030-1of1. dgn 1. See wall control drawings for soil characteristics of foundation material Soil Reinforcement Length to be used in the design of the wall system. The Contractor must provide soil design parameters for backfill material based on the actual soil characteristics utilized at the site. Provide the values of unit weight, TYPICAL RETAINING WALL SECTION cohesion and internal friction angle in the Shop Drawings. (Showing Limits of the Reinforced Soil Volume) MATERIALS: 1. Provide soil reinforcement in accordance with Specification Section 548. 2. For additional material notes, see Wall Company General Notes. CONSTRUCTION: 1. Walls must be constructed in accordance with Specification Section 548 and the Wall Company’s instructions. 2. For location and alignment of retaining walls, see Wall Control Drawings. 3. Refer to Plan and Elevation sheets of individual walls for minimum Varies (See Index No. 414 2’-0" Min. and Wall Control Drawings) reinforcement strip/mesh length, factored bearing resistance’s, minimum wall embedment and anticipated long term and differential settlements. 4. Type K Temporary If existing or future structures, pipes, foundations or guardrail posts within Traffic Railing the reinforced soil volume interfere with the normal placement of soil Dropoff reinforcement and specific directions have not been provided on the (See Index No. 414 for Details) plans, the Contractor must notify the Engineer to determine what course of action should be taken. 5. The Contractor is responsible for gradually deflecting upper layer(s) of soil reinforcement downward (15 maximum from horizontal) to avoid cutting soil reinforcement and conflicts with paving and subgrade 45 preparation. The Contractor’s attention is directed especially to situations where roadway superelevation and/or soil mixing are Front Face of anticipated. Temporary 9: 34: 47 AM rd960rh Retaining Wall TEMPORARY TRAFFIC RAILING 12/30/2011 PLACEMENT DETAIL LAST REVISION 01/01/11 REVISIO N GENERAL NOTES AND DETAILS DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 TEMPORARY MSE RETAINING WALL SYSTEMS NO. 6030 SHEET NO. 1 Bulkhead Cap SHEET PILE DESIGN CRITERIA AND NOTES (See Bulkhead Plans for actual Cap outline) DESCRIPTION: This Design Standard includes details for three types of piles with two thicknesses. Types "B" and "C" piles (corner piles) are of reinforced concrete construction, and Type "A" is of prestressed Compacted Fill of the contract documents. ( M in. ) 1’ -0" concrete construction. The piles shall be manufactured, cured and installed in accordance with the requirements MATERIALS: (for materials not listed refer to the Specifications) CONCRETE Class: V (Special) for slightly and moderately aggressive environments V (Special w/ Silica Fume) for extremely aggressive environment Plastic Filter Fabric (Continuous) Sheet pile Unit weight: 150 pcf Modulus of Elasticity: Based on the use of Florida limerock concrete REINFORCING STEEL ASTM A615 Grade 60 PRESTRESSING STEEL ASTM A416 Grade 270 (Low-Relaxation Strand) Existing Ground (Mud Line) CROSS REFERENCES: DESIGN PARAMETERS: For Dimensions L and X see Sheet Type "A" 1’ -8" Pile Data Table in Structures Plans. Concrete Compressive Strength at release of prestressing: 4000 psi minimum Uniform compression after prestressing losses: 1000 psi minimum Pick-up, Storage and Transportation: 0.0 psi tension with 1.5 times pile self weight Types "B" & "C" Bottom of Dim. X Pick-up, Storage and Transportation: Minimum compressive strength f’ci = 4000 psi required. and Filter Fabric ENVIRONMENT: C: \d\projects\standards\structures\current\ready4release\2012book_draft\06040-1of4. dgn The pile designs are applicable to all Environments. SECTION THRU BULKHEAD PLASTIC FILTER FABRIC: (Showing Plastic Filter Fabric) The plastic filter fabric shall extend to the bottom of the "X" dimension. PILE PICK-UP AND HANDLING: Type "A" Grout (Typ.) (See Specifications) ~ Pick-up of pile may be either a single point pick-up or a two point pick-up as shown below. Types "B" & "C" 2’-6" Two point pick-up for lifting out of forms & two point support for storage & transportation. Type "A" (Typ.) Single point pick-up for installation only. PILE FIT-UP: ~ 90 The 2’-6" Sheet Pile dimension is nominal. This dimension may be shortened by the Manufacturer up to b" to allow for Sheet Pile fit-up in its final position. Minimum Sheet Pile width is 2’-5b". No changes shall be made to the tongues or grooves. Type "A" Type "A" Type "A" Type "C" Starter Pile Type "B" Plastic Filter Fabric DETAIL "A" (Cap and Anchoring System Not Shown) (Section Taken Above Dimension X) NOTE: Detail "A" shows a Part-Plan View of an assumed bulkhead. See Bulkhead plans for actual Plan View. 1’-3" »¿ Pile and Starter Pile Single Point rd960rh 2 Point Pick-up, Tie Down and Support Points Pick-up 1’-3" T 1 y C o pi ’-3 r " n ca e l r f o P il r e s 9: 34: 48 AM 0.21 L DETAIL "A" 0.58 L 0.21 L L PILE STORAGE AND TRANSPORTATION SUPPORT DETAILS 12/30/2011 (Section Taken Below Dimension X) LAST REVISION 01/01/11 REVISIO N NOTES AND DETAILS DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 PRECAST CONCRETE SHEET PILE WALL NO. 6040 SHEET NO. 1 BAR BENDING DIAGRAMS L 4" (Typ.) 11" X (Typ.) Slope only on the tongue side 10" S2 Bar S5 Bar S4 45 S1 " Bars " 0 ’1 Bars BAR A 4b " 1’-6 S5 1’-10 " " S6 11" S7 1’-7 " B T=10 in. 4" T=12 in. 6" 7" B 2-PIECE 6 sp. @ 4" 2’-2" S4 DIMENSION B B A " 1’-9b " S3 A Varies 1’-11 S2 A Pick-up Strand(S) 1’ -0 11" ( Typ. ) S1 B Strands 1’ -3" 2 ~ Bars A DIMENSION A (Typ.) Prestressed ( M in. Lap) A Spaced at 1’-0" Maximum 3 " 6 sp. @ 4" 1-PIECE BAR S Spacing for Bars S NOTES: TYPICAL PILE 1. Intermediate Prestress Strands not shown in Elevations and Sections. T(in.) Y(in.) 11" X 10 » Z(in.) 3. 12 » 3 Bars A are #5 and Bars S are #4. 4. At the Contractor’s option Bars S may be fabricated as a two piece bar as shown in the Bar Bending Diagram. 5. The Contractor may use Deformed Welded Wire Reinforcement conforming to 4 (Typ.) specification ASTM A497 in lieu of Bars A and Bars S if the wire size and spacing provide the same area of reinforcing steel per foot as the Bars shown. 10" 2 " D (Typ.) Bars A ( Strands) (Typ.) Bars S2 3" Cover n sp. @ D Bars S1 3" Cover T See Detail "D" 2’ -6" 2 " n sp. @ " 1’ -0 2’ -6" Bar S7 Bar S6 Bars A n sp. @ S2 See Detail "E" 2’ -6" Bars S3 ( Strands) Strand(S) Bars D 11" Pick-up T 2" Cover T See Detail "D" ( Strands) B Strands 2" Cover (Typ.) Prestressed 2 ~ Bars A 6. For Dimensions L and X see Sheet Pile Data Table in Structures Plans. 2" Cover C ( Typ. ) Bars S3 3" Cover (Typ.) 6 sp. @ 4" Spaced at 1’-0" Maximum 6 sp. @ 4" 3 " SECTION A-A Y STARTER PILE 3 b" 2 Thickness (in.) L T=10 in. 0.5 28’-0" 6 0.6 27’-0" 4 0.5 31’-0" 7 0.6 30’-0" 5 9: 34: 49 AM T=12 in. n D (in.) 3 5 2 4 TOTAL # OF STRANDS " Y Z b" b" 4" 3" 2" 2 " SECTION C-C Z b" * STRESS SECTION MODULUS (in.‡) (psi) 14 500 1150 10 500 1160 16 720 1100 12 720 1160 2 " MAXIMUM " SECTION B-B 2" rd960rh STRAND DIA. 2" Spacing for Bars S Wall Cover 4b " 7" B Cover 2 ~ Bars A C Cover Bars A 2" C: \d\projects\standards\structures\current\ready4release\2012book_draft\06040-2of4. dgn 2. All bar dimensions are out-to-out. SHEET PILE DIMENSIONS L 12/30/2011 * Unit Prestress after losses. DETAIL "D" DETAIL "E" (Typical Tongue) (Typical Groove) LAST REVISION 01/01/11 REVISIO N TYPE "A" STANDARD SECTION DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 PRECAST CONCRETE SHEET PILE WALL NO. 6040 SHEET NO. 2 L See Detail "D" Slope only on tongue side 11" Slope is to 11" this point C T X 2’-2" Bars A3 B Bars A1 Bars A2 7" Bars A2 A Bars A1 Bars A2 Bars A1 Bars A3 Bars A3 " -3 1’ Bars A3 Bars S3 Bars A4 S2 Bars A3 Bars A4 Bars A4 S1 4" Bars S1 Bars A4 Bars S2 Bars A4 Pick-up Strand(s) Bars A4 Bars A4 Bars A4 Bars A4 Bars S4 Bars A4 Bars A4 1’ -3 " Bars A4 3" Cover (Typ.) 3" Cover (Typ.) SECTION A-A T A Bars A4 B C SECTION B-B T 10" bT VIEW C-C 4 " 6 sp. @ 4" Spaced @ 1’-0" Maximum 6 sp. @ 4" 3 " R2 R3 R4 R5 " 1’-6b " 2b " 5" S2 1’-1b " 9 " 1’-8 2b " 4b " " 4 " 5b " R7 R8 5b " 4 " 5 4 " " BAR MARK R1 S1 11b " S2 30 1’-1 " 2" R3 R4 10" 1’-6" 3b " R5 R6 7" 10" 1’-8 " 3b " 6b " »¿ 1’-5 2" 7" 4 R7 R8 " 5 " 6" 5 " 5 " 6" 4 4b " T (in.) 30 S3 S4 11 " 4 " S1 11b " 8" S2 1’-1 1’-6" 8" 11 " " 8" 1’-1 " 1 " 1 1’-5 " 4" 1’-4" 4" " 5" 4b " 4b " 5" 3 5b " 4b " " 6b " S3 11b " " 2b " 6 " S4 11b " 4" 1’-1 " 2 " 7" 8" 4" S1 1’-0" 8b " 1’-3 " 5 " 7b " 8" 7b " 5" 3 " 2b " 8 " 6 " 8b " 5 " S2 1’-2 " 8b " 1’-5b " 5 " 6b " 7 " 5b " S3 1’-0" 7" 1’-4" 3" 7b " 6 7" S4 1’-0" 3b " 4" 45 7 " " 8b " 5 " S3 11b " 6 " 1’-4" S4 11b " 3b " 1’-0" 3" S1 1’-0" 6" 1’-0 " 5 " S2 1’-2" 6" 1’-2 " 5 " S3 1’-0" 4 1’-1b " 3 " 6" S4 1’-0" 2b " 10" 4b " 6" 5b " 5b " 6 6 " " " 7" 7 " 6" 4 " 11 " 3 " 7b " 5" 3b " 9" 7 " 10 " 3" S1 1’-0b " 6 " 11 " 7" 8 10b " 3" S2 1’-2 6 " 1’-2" 7" 5 " S3 1’-0b " 5" 1’-1b " 4" 8" 8" 9" 7" 7b " S4 1’-0b " 2b " 9b " 5b " 8" 5b " 4 " 9 " " " 8" 6 " 6 " 8" 10 " 4" 10 " 4" Y (in.) Z (in.) 12 3 4 3 4 b" Z b" 4" bT Z 3b " 5" 10 3" 45 2 " SHEET PILE DIMENSIONS Bars A1 or A4 " R2 Bars S Bars A2 STIRRUP DIMENSIONS (T = 12") R6 9 b" 2 bT T 60 60 " 8 8" 5 " 4" " DETAIL "D" NOTES: R6 4" R5 R6 ( Typ. ) 4" ( Typ. ) 1. This drawing includes details for precast concrete corner piles for 10" R5 R5 and 12" thick sheet pile systems. The details apply equally to both thicknesses. R6 2. The bar configurations shown in Sections A-A and B-B shall be used for angles between 15 and 75. For angles not shown, the reinforcing bar 3. All bar dimensions are out-to-out. R3 R1 R3 R3 R1 dimensions may be interpolated or extrapolated from the stirrup dimensions shown. R1 rd960rh R1 11 " Y " 2" Co ve r BAR BENDING DIAGRAMS S1 2 2" r ve Co C: \d\projects\standards\structures\current\ready4release\2012book_draft\06040-3of4. dgn (TYPE "B" PILE) BAR MARK » ¿ b" Bars S ELEVATION STIRRUP DIMENSIONS (T = 10") bT Y Spacing for Varies 4. Bars A are #8 and Bars S are #4. 5. Values for Stirrup Dimensions are shown for equal to 30, 45 & 60 only. R2 R2 R8 R7 R8 R4 R4 R4 R2 12/30/2011 R7 " 0 ’1 9: 34: 50 AM 6. At the Contractor’s option Bars S may be fabricated as a 2 piece bar with 45 R7 R8 BAR A2 a minimum lap length of 1’-6", as shown in Bar Bending Diagrams. 7. If Type "B" pile is used as a Starter Pile show tongue on both sides of pile from Dim. X down. Show dimensions for Bars S2, S3 & S4 in shop drawings. 8. If tongue must be on the opposite side from that shown all dimensions and Bars A, S2, S3 and S4 will be the same but opposite hand. 9. For Dimensions L, X and Angle , see Sheet Pile Data Table in Structures Plans. 1 - PIECE 2 - PIECE BARS S3 & S4 TYPE "B" - VARIABLE ANGLE CORNER PILE LAST REVISION 01/01/11 REVISIO N BARS S1 & S2 DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 PRECAST CONCRETE SHEET PILE WALL NO. 6040 SHEET NO. 3 here if T=12" B C D See Section C-C Bars A1 2 ~ Bars A2 10" A Bar A4 T (Typ.) Bars S3 ** Bar A4 T Bar A5 1’ -9" Bar A5 1’ -8" 1’ -9" Bars S1 1’ -8" T S2 * Bar A4 * Bar A4 Bars S4 Section C-C 3" Cover Bars A1 Bars S5 See 2" X ( Typ. ) 2’-2" Bar A6 Pick-up Bars A2 ** Bar A4 Bar A6 T " This A4 bar ends T For 12" Pile 10 1’-4" For 10" Pile L Strand(s) For 12" Pile For 10" Pile Bars A5 3" 1’-8" D (Typ.) 1’-9" C Bars A3 Bars S2 Bars A3 Bars A3 7" 2" (Typ.) A B 3" Cover Bars S1 END VIEW 4" Spaced @ 1’-0" Maximum 6 sp. @ 4" 3 " 6 sp. @ 4" Spacing for SECTION A-A 1’-8" For 10" Pile 1’-9" For 12" Pile SECTION B-B Bars S ELEVATION * This Bar A4 shall be 1’-2" shorter than other A4 bars for T = 12". (TYPE "C" PILE) Bars A2 ** This Bar A4 (not shown in elevation) is included only if T = 12". T " BAR BENDING DIAGRAMS Bar S2 Y Bar S3 Bar A5 2 " R2 STIRRUP DIMENSIONS R3 b" T (in.) Bar S4 BAR MARK R1 S1 7" R2 R2 b" R3 10 Bar A6 8" 4 " 7 " 4 " S4 5b " 6b " 4 " S5 4 5 " 4 " 4 " 12 Bars S2 S1 9" S2 9" 7" 6 " S3 8 " 6 " 6 " S4 7b " 5b " 6 " S5 6 4 6 " 9" 6" 6" 5" 5" 1’-3" For 10" Pile 1’-3" For 12" Pile For 12" Pile 3" b" T For 10" Pile 45 - (Bars A2 only) BARS A Bar S2 Bar S3 Bar A5 Note: All Bar dimensions are out-to-out. SHEET PILE DIMENSIONS Bar S4 Bar A4 T (in.) 10 12 Y (in.) Z (in.) SECTION C-C (T=10" or 12") Bar A6 NOTES: 1. All bar dimensions are out-to-out. Bar S5 Bars 3 4 A3 rd960rh " " 0 Z 2 " »¿ Bul " Varies 1’-2" ’ 1 4" Bars A2 Bar A6 STIRRUPS S 0" A5 " 3b "A3 Bars A3 Bar A4 4" 7" 6 " 2b " A4 SECTION D-D (T=10") b" S2 S3 4b "A2 & A6 ** Bar A4 7" 90 1’ -3" 1’ -3" Bars A2 " 4" *Bar A4 Bar A5 5 R1 Bar S5 A3 2" 2" Bars Z C: \d\projects\standards\structures\current\ready4release\2012book_draft\06040-4of4. dgn Bar A4 3 Y 3 4 2. Bars A are #8 and Bars S are #4. 3. This drawing includes information for precast Corner Piles for 10" and 12" thick Sheet Pile systems. The details apply to both thicknesses but the bar configurations change slightly according to the thickness values used. 4. If Type "C" pile is used as a Starter Pile show tongue on both sides of 9: 34: 51 AM pile from Dim. X down. Show dimensions for Bars S2, S3, S4 & S5 in shop drawings. 5. If tongue must be on opposite side (Groove Side) from that shown, all dimensions and reinforcement shall follow the corresponding Tongue or Groove side. 12/30/2011 SECTION D-D (T=12") 6. For Dimensions L and X see Sheet Pile Data Table in Structures Plans. LAST REVISION 01/01/11 REVISIO N TYPE "C" - RIGHT ANGLE CORNER PILE DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 PRECAST CONCRETE SHEET PILE WALL NO. 6040 SHEET NO. 4 » b " Open Joint Dim. A ) . n "Mi 0 ’ 0 1 l ( a c i p "Ty 0 ’ 0 g~ 3 n i c a p S t n i o nJ e b"Op Top of C-I-P » b " Open Joint sp. (lap with Dowel Coping) A Slope of C-I-P * 2" Min. Cover (Typ.) Retaining Wall Panel) (Typ.) ** 3" Min. Cover (Typ.) Drainage Ditch when Coping Bars 4A (follows Bars 4U1 @ 1’-6" Max. Bars 4B (follows top of required (See Wall Control Bars 4U1 Drawings for details) " Chamfer Bars 4D) (Typ.) Bars 4A (Typ.) Varies (1’-3" Max., (Typ.) (See 2" Min.) 2’ -0" Dowel Bars 4D Note 2) Bars 4B shown as ( ) Top of Retaining Dowel Bars 4D Wall Panel (Typ.) Clearance Bottom of (See Note 2) 6" Varies C-I-P Coping Retaining Wall Panel Retaining Wall (See Wall Company Panels (Typ.) Drawings for Details) A Smooth or Textured Face of Panel PRECAST AND C-I-P COPING NOTES: C: \d\projects\standards\structures\current\ready4release\2012book_draft\06100-1of2. dgn 1. Provide Class II concrete for slightly aggressive environments or Class IV for moderately or extremely aggressive environments. C-I-P COPING - PARTIAL ELEVATION VIEW 2. SECTION A-A Panel width C-I-P COPING Dowel Bars 4D extend 1’-0" above the top of retaining Dim. A + 6" wall panel. Field cut as necessary to maintain 2" minimum Panel width cover. See Wall Company Drawings for number and spacing Dim. B of Dowel Bars 4D. 3. + 1’-0" Min. Payment for Dowel Bars 4D, Buildup Concrete and Coping will be made under Retaining Wall System (Permanent). » b " Open Joint Dim. B * 2" Min. Cover (Typ.) » b " Open Joint Control Drawings Bars 4U2 * For Slightly and Moderately Bars 4A Aggressive environments for details) (Typ.) " Chamfer (Typ.) ** For Extremely Aggressive environments. 2’ -0" 2" Cover Min. 1’ -3" Buildup Concrete B required (See Wall Wall Panel (Typ.) 2" Cover Varies Coping ( 1’ -0" M ax. ) Top of Precast Drainage Ditch when ** 3" Min. Cover (Typ.) Top of Retaining ) . n "Mi 0 ’ 5 g( n i p tCo s a c e lPr a c i p "Ty 0 ’ 0 1 Top of C-I-P C-I-P Buildup Concrete (1’-0" Max.) Provide 3b " x 3b " preservative treated timber blocking @ 5’ Max. Spacing for gaps > 1" Bars 4U2 @ 1’-4" sp. (Typ.) Varies (1’-3" Max., Bars 4A Clearance rd960rh Dowel Bars 4D " (See Note 2) Varies Dowel Bars 4D (Typ.) Bottom of 2" Min.) (See Note 1) Precast Coping 6" 6" Min. Min. " Std. ( b " Min. ~ 2b " Max.) Retaining Wall Retaining Wall Panel Panels (Typ.) (See Wall Company B Smooth or Textured Face of Panel 9: 34: 52 AM Drawings for Details) SECTION B-B PRECAST COPING LAST REVISION 01/01/12 REVISIO N 12/30/2011 PRECAST COPING - PARTIAL ELEVATION VIEW DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 MSE WALL COPING (PRECAST OR C-I-P) NO. 6100 SHEET NO. 1 REINFORCING STEEL BENDING DIAGRAMS - PRECAST AND C-I-P COPINGS BILL OF REINFORCING STEEL MARK SIZE LENGTH LENGTH * S or M * E Dim. B REINFORCING STEEL NOTES: * 2" Min. Cover (Typ.) 1. All bar dimensions in the bending diagrams are out to out. ** 3" Min. Cover (Typ.) Drainage Ditch when 2. All reinforcing steel at the open joints will have a 2" minimum cover. required (See Wall 3. Bars 4A may be continuous or spliced at the construction joints. Lap splices for Bars 4A will Control Drawings Bars 4U2 Bars 4A be a minimum of 1’-8". A 4 AS REQD. AS REQD. B 4 AS REQD. AS REQD. D 4 2’-0" 2’-0" 3 4" 4. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded Wire for details) (Typ.) Chamfer (Typ.) Reinforcement will conform to ASTM A 497. Recess Varies Varies (1’-3" Max., 2" Min.) 2’ -0" * S = Slightly Aggressive Panel width + 4" Panel width + 3" U2 4 Panel width + 8" Panel width + 6" 4 U3 Varies Panel width + 3" Dowel Bars 4D Varies (See Note 2, Sheet 1) Ground Line 6" required to maintain 2" minimum cover DOWEL BAR 4D BARS 4A & 4B BAR 4U1 BAR 4U2 BAR 4U3 6" Min. 2’ -0" M in. * 1’ -8" Field cut as ** 1’ -6" * 1’ -8" Length as Required 4B ** 1’ -6" Length as Required 2’ -0" 4A Panel width + 4" E = Extremely Aggressive Varies 4 * 8" M in. U1 ** 6" M in. M = Moderately Aggressive (Match Precast Dimensions) Retaining Wall Panel Leveling Pad for (See Wall Company MSE Wall Shown Drawings for Details) C-I-P COPING USED WITH PRECAST COPING wall, use this similar C-I-P coping for short portions between precast coping units. This C-I-P coping may also be used for vertical copings. Dim. C * For Slightly and Moderately Aggressive environments Top of Coping Top of Retaining * 2" Cover (Top & Sides) Wall End Panel ** For Extremely Aggressive ** 3" Cover (Top & Sides) C 3 4" Retaining Wall Spacing Bars 4A (follows Slope of C-I-P Coping Enclosure) Bars 4B (Horizontal) (Field cut as required to maintain Chamfer (Typ.) Bars 4B Begin or End environments. Panel width minimum cover) Dim. B Bars 4A (Typ.) + 1’-0" Min. Panel width Bottom of Coping Drawings for details) Bars 4B shown as ( ) (Typ.) Bars 4U3 Bars 4U3 @ 1’-6" Edge of Retaining Max. sp. (Typ.) Bars 4B (Horizontal) 4" Cover C Leveling Pad for 9: 34: 53 AM (Bottom) 3" Min. Overlap 412" rd960rh 6" Wall End Panel 2’ -0" M in. (See Wall Company Coping Enclosure + 6" Varies Retaining Wall End Panel Edge of C-I-P 1’ -6" M ax. Dim. C Eq. sp. @ C: \d\projects\standards\structures\current\ready4release\2012book_draft\06100-2of2. dgn Note: When precast coping units do not fit the entire length of the retaining MSE Wall Shown SECTION C-C Varies LAST REVISION 01/01/12 REVISIO N 12/30/2011 C-I-P COPING ENCLOSURE DETAIL DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 MSE WALL COPING (PRECAST OR C-I-P) NO. 6100 SHEET NO. 2 1" Dowel Load Transfer Devices (See Typical Sections Top of for details) Junction Slab Expansion Joint (See Bars 5C @ 8" sp. Bars 5B2 4 ~ Bars 5F b" V-Groove (See 2" Cover (tie to Bars 4A) Note 7 & Detail "A") Sides (Typ.) (Typ.) Bars 4A @ "Expansion Joint Detail" 1" Dowel Load this sheet and Detail "A") Transfer Devices 4" (Typ.) (Top of Slab) Approved metal (Required only or fiber cap when Junction Slab is skewed) 2’ -0" M in. Junction Slab 3" Approach Slab " Preformed Expansion (See Note 12) 3s p. @ 6" Joint Filler 1’-0" Lap Splice " Bottom of Gutter Line 1’-0" »¿ Expansion Bars 4L @ 8" sp. (Typ.) EXPANSION JOINT DETAIL (Junction Slab expansion joints are to coincide with Field cut reinforcing as required " open joints in Traffic Railing) 3" Spacing Bars 5V2 " Open Joint to maintain minimum cover (Typ.) Bars 5V2 (Typ.) Bars 5S Coping Bars 5B1 in Precast Coping 8" Spacing (Typ.) (See Note 1 & 9) CROSS REFERENCE: For Detail "A", see Sheet 2. 2" Cover @ b " V-Groove Spacing 2" Cover @ 30’-0" Max. (See Note 7) Expansion Joints » Begin or End Retaining Wall »¿˘" Expansion Joint Spacing ~ 30’-0" Min., 90’-0" Max. (See Not " Open Joint in Precast Coping and C-I-P Traffic and Precast or C-I-P Coping Railing to coincide with PARTIAL PLAN VIEW FOR F-SHAPE TRAFFIC RAILING " Open Joint " Expansion Joint in Junction Slab. (Skewed Approach Slab Shown, Perpendicular Approach Slab Similar) (Precast Coping Shown, C-I-P Coping Similar) (Traffic Railing not Shown for Clarity) JUNCTION SLAB NOTES: »¿ ˘" Open Jo 1. Precast Coping and Top of Precast Coping Railing Provide Class II concrete for slightly aggressive environments or Class IV for moderate or extremely Top of C-I-P aggressive environments. Buildup Concrete Dowel Load Transfer Devices will be ASTM A 36 smooth round bar and hot-dip galvanized in accordance with Specification Section 962. Install Dowel Load Transfer Devices in accordance Top of Retaining with Specification Section 350. »¿5. Wall Panel (Typ.) Construct ˘" Expansion Joints in junction slabs and C-I-P copings plumb and perpendicular or radial to -3" 2’ Gutter Line. Provide at 90’-0" maximum intervals as shown. Provide 3"x3" Mortar plugs in open joints at the ( 9" M ax. ) 4. Varies and/or junction slab is not permitted. 3. base of traffic railings to contain runoff. 6. Provide and install Preformed Expansion Joint Filler in accordance with Specification Section 932. 7. Construct b" V-Grooves in junction slabs and C-I-P copings plumb and provide at 30’-0" maximum intervals as »¿ Mortar Plug (See Note 5) 3" Construct the Junction Slab level transversely and expansion joints plumb; do not construct the junction slab or C-I-P coping perpendicular to the roadway surface. Slip forming of Coping 2" Cover M in. CONSTRUCTION REQUIREMENTS: Precast Traffic Railing Traffic Railing Traffic spacing within 6’-0" of Open Joints for precast coping with the 42" F-Shape Traffic Railing. 2. Top of Coping For TL-5 crash test rating increase Expansion Joint Spacing to 60’-0" minimum and provide Bars 5C at 6" max. ) . n "Mi 0 ’ 5 y( l n gO n i p tCo s a c e l Pr a c i p y "T 0 ’ 0 1 s* n o i t c e S g n i p g & Co n i l i c Ra i f f a r tT s a c e m Pr mu i n "Mi 0 ’ 2 1 Precast APPLICATIONS: This junction slab is only applicable for a TL-4 crash test rating. Varies C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-1of6. dgn Open Joints shown. Space V-Grooves equally between ˘" Expansion Joints and/or Begin or End Junction Slab. V-Gr locations are to coincide with V-Groove locations in the Traffic Railing. rd960rh 8. Shoulder or Roadway Pavement is required on top of the junction slab for its entire length on the traffic Clearance side of the Traffic Railing. See Typical Sections on Sheet Nos. 2 and 3 for details. 9. Varies Spacing shown is along the Gutter Line. 10. On MSE Walls provide, Dowel Bars 4D and extend to 7" above the top of retaining wall panel. Field cut as Bottom of Dowels 4D (Typ.) Precast Coping (See Note 9) necessary to maintain 2" minimum cover to the top of the buildup concrete. See Wall Company Drawings for 9: 34: 53 AM number and spacing of Dowel Bars 4D. 11. Work this Index with the following: Retaining Wall (MSE Shown, Index No. 420 - Traffic Railing - (32" F-Shape) Other Types Similar) (Typ.) Index No. 425 - Traffic Railing - (42" F-Shape). 12. PARTIAL ELEVATION VIEW The following Indexes contain details of the intersection of the retaining wall at approach slabs: (Precast Coping and Junction Slab Reinforcing not Shown for Clarity) (Precast Coping Shown, C-I-P Coping Similar) Index No. 20910 - Approach Slabs (Rigid Pavement Approaches) LAST REVISION 01/01/12 REVISIO N 12/30/2011 Index No. 20900 - Approach Slabs (Flexible Pavement Approaches) * C-I-P End Section must be = 12’-0". DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 1 1 2" 6’-6 3 4" 2 (C-I-P Junction Slab) »¿ Bars 4N @ 8" sp. Joint Permitted expansion joints (Typ.) for C-I-P 3 Coping Bars 5S 3 1’ -0" (See Note 2) 6" 1’ -0" NOTE: See Index No. 420 and Index No. 425, Detail "A" for details. 2" Cover 6" (Showing Bars 5V and Bars 5S) (Precast Coping Shown, C-I-P Coping Similar) 3" Cover Bars 4L @ 8" sp. Utility Conduit permitted C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-2of6. dgn Bars 5B2 @ 1’-0" sp. (Typ.) Slope Permitted See Note 7 ESTIMATED QUANTITIES FOR PRECAST COPING UNIT Concrete (Precast Coping Only) Two Layers 30Lb. Roofing Felt QUANTITY CY/LF 2’ -3" 3 4" TRANSITION FOR GUARDRAIL ATTACHMENT ITEM Top of ( Precast Coping) PARTIAL END VIEW OF TRAFFIC RAILING END 3 4" @ 8" sp. 3 4" ( Se e No t e1 ) Bars 5V2 6" Sl o p e Va r i e s » ¿ asphalt or See Note 3) 7" substituted) 2" Cover (Top) 3" Pavement (Full depth 3 4" Shoulder or Roadway (Bars 5V2 may be 1 End Stirrup Bar 5V 114" 10 "R Sections* Bars 4A @ 4" sp. Precast Coping 2 "Co v e r Construction Transfer Devices at (Rotated) 812" 1" Dowel Load (Typ.) 12’ -0" M in. Length) 1’ -10" Bars 5S 1’ -114" Bars 5V 8" 6" Bars 5S (Field Bent) (Tied to alternate Bars 4A) 2’ -8" Bars 5C @ 8" sp. Min. Embed. (42" F-Shape) Coping ( Precast Traffic Railing @ 8" sp. Min. Embed. (32" F-Shape) 114" Bars 5P " 1 3" 4 2" 4 Railing 214" Traffic 1’ -0" 312" (Tied to Bars 5P) »¿3˘" Precast 32" F-S 714" »¿1˘" C-I-P F-Sh Top of Precast Coping 1 2" 8 5" 312" 5’-0" 8" (42" F-Shape) 2" (32" F-Shape) 1’-5" Cover 1’-2b " Varies (2" min.) 2" Min. Cover 0.079 Spacing Bars 5B1 514" Optional widening & extension for Precast Coping (See Note 6) Retaining Wall (Type Varies) Concrete (Precast Barrier & Coping) CY/LF Dowel Bars 4D (MSE Walls only) 0.165 Concrete (C-I-P Junction Slab) Reinforcing Steel (Precast Coping & Traffic Railing) CY/LF Spacing Dowels 0.185 Bars 5S 6" »¿ C-I-P Buildup Concrete » LB/LF 52.67 LB/LF (MSE Walls only) Smooth or Textured b" Min. ~ 2b" Max. Gap Face of Wall Spacing Reinforcing Steel (C-I-P Junction Slab) (Typ.) 6" 3 sp. @ 1’-0" = 3’-0" 1’-3" Spacing 1" 4 sp. @ 1’-0" = 4’-0" (5B2) 3" 2 sp. @ 1’-0"– (5B1) 3" Bars 5B 12.52 TYPICAL SECTION THRU PRECAST* 32" F-SHAPE Additional Reinf. @ Expansion Joints LB TRAFFIC RAILING AND COPING WITH C-I-P JUNCTION SLAB 21.36 * C-I-P Traffic Railing and Coping Sections using precast dimensions (The above concrete quantities are based on a max. superelevation of 6.25% and reinforcement are permitted at End Sections, Drainage Inlets and and a 32" F-Shape Traffic Railing. Light Pole Pedestals if slip forming is not used. NOTES: 1. Match Cross Slope of Travel Lane or Shoulder. »¿2. The 3˘" dimension corresponds to a maximum superelevation of 6. For steeper superelevations increase this dimension to match roadway superelevation. b " V-Groove (Typ.) b " V-Groove (Typ.) 3. For Rigid Pavement (Concrete), Junction Slab may be thickened to match rd960rh finish grade. 4. Minimum length of Junction Slab between expansion joints is 30’-0". »¿˘" Preformed Expan Joint Filler »¿˘" Preformed Expan Joint Filler 5. At the Contractor’s option, mechanical couplers may be used to splice reinforcing. Complete details, including reinforcement lengths are required in the Shop Drawings. Provide mechanical couplers in accordance with 9: 34: 55 AM Specification Section 415. Mechanical couplers shall develop 125% of the bar yield strength. C-I-P COPING PRECAST COPING 6. Contractor to maintain stability of precast coping/traffic railing prior to junction slab completion. In the Shop Drawings, show reinforcement for optional extension required for stability, shipping and handling. Maintain 12/30/2011 DETAIL "A" (Showing Locations of b " V-Grooves and 2" minimum concrete cover. " Preformed Expansion Joint Filler) 7. Angle varies ~ 0 min., 20 max. REVISION 01/01/12 REVISIO N F-SHAPE TRAFFIC RAILINGS LAST DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 2 6’-6b" (32" F-Shape) REINFORCING STEEL BENDING DIAGRAMS 3’-9" 6’-9" (42" F-Shape) »¿ b" (32" F-Shape) (42" F-Shape) 4’-8" F 5 4’-8" 4’-8" 4’-8" L 4 4’-5" 4’-5" 4’-5" N 4 2’-6" N/A N/A Transfer Devices at S 5 11’-6" AS REQD. 9’-6" S1 8 N/A AS REQD. 9’-6" 5 5’-10" 5’-10" 5’-10" 2’-0" 2’-0" 2’-0" 1 2" 5 Smooth 1" Dowel 11’-6" (Precast Traffic Railing) 5B2 Length as Required 134" Expanded Polystyrene (b" Side) (for C-I-P only) Precast Coping ~ 4’-8" (See Note 7) 8b " Contractor’s 2’-0" 1’ -1b " 10" 412" 412" 1" 5430’ g~ n i p tCo s a c e Pr ) 5& 6 e t o N e Se "( 9 ’ 3 " 2 ’ g ~6 n i p P Co I C- 86 5" 5B2 ~ C-I-P Coping Spacing Smooth or Texture 4 sp. @ 1’-0" = 4’-0" 3" Face of Wall 2 sp. @ 1’-0"– 3" Bars 5B2 TYPICAL SECTION THRU C-I-P TRAFFIC RAILING Construction Joint Permitted Optional Keyway WITH C-I-P JUNCTION SLAB AND C-I-P COPING Buildup for (PRECAST COPING SIMILAR WITH C-I-P BUILDUP) stepped MSE Wall Panels 2" BARS 5B, 5C, 5F & 5S 5B1 ~ Precast, 45 M in. 1" DOWEL Spacing Bars 514" (Precast) 3 sp. @ 1’-0" = 3’-0" 6" C-I-P Coping ~ Length as Required 6" 512" (C-I-P) Dowels 3’ -1b " ( 42" F-Shape) 32" F-Shape), 9’-6" (Coping Only) 45 2’ -8b " ( 32" F-Shape) 8S1 1’-3" Spacing 1" Precast Coping, ~ 11’-6" (with 5S 6" Spacing M ax. 9 " 4’-8" 1 ’ -2 " 1 (3 ’ -5 2 " " (4 F ) 2 " F ) 5F Retaining Wall (Type Varies) option Bars 5S (0" min., »¿11˘" m Coping Expanded Polystyrene (b") 6" 10" (32" F-Shape) 1’-0b" (42" F-Shape) 6" ESTIMATED QUANTITIES FOR C-I-P COPING BUILDUP FOR STEPPED MSE WALL PANELS STIRRUP BAR 4N REINFORCING STEEL NOTES: NOTES: ITEM UNIT QUANTITY 1. All bar dimensions in the bending diagrams are out to out. »¿2. The 3˘" dimension corresponds to a maximum superelevatio 6.25%. For steeper superelevations increase this dimension to match 2. All reinforcing steel at expansion and open joints will have a 2" minimum cover. Concrete (Traffic Railing not Included) 3. Lap splices for Bars 5B & 5S will be a minimum of 2’-0". 5. The Contractor may use either full length Bars 4A or lap splice with Bars 5C at alternate Bars 4A CY/LF 0.264 for C-I-P Copings. roadway superelevation. 3. For Rigid Pavement (Concrete), Junction Slab may be thickened to match finish grade. Reinforcing Steel (Typical) excluding Bars 5V2 and 5S (Typ.) LB/LF 30.89 4. Minimum length of Junction Slab between expansion joints is 30’-0". 5. See Index No. 420 & 425 for additional Traffic Railing Details. 6. Dimension shown is for lap splice option. For mechanical coupler option, this dimension is 1’-4b" 6. Contractor to maintain stability of precast coping prior to junction (32" F-Shape) or 1’-7" (42" F-Shape). 7. Dimension shown is for lap splice option. For mechanical coupler option, this dimension is 4’-8". Additional Reinf. @ Expansion Joint LB/LF 21.36 slab completion. In the Shop Drawings, show reinforcement for optional extension required for stability, shipping and handling. 8. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded Wire Reinforcement will conform to ASTM A 497. AND C-I-P COPING 1. Match Cross Slope of Travel Lane or Shoulder. STIRRUP BAR 5V2 4. For Precast Copings only, lap splice Bars 4A with Bars 5C. Lap splices will be a minimum of 2’-0". 9: 34: 56 AM 3b " Bars 5B2 @ 1’-0" sp. (Typ.) Optional widening & extension for Precast Coping (See Note 6) 5C 1’ -10" C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-3of6. dgn 2" Cover See Note 7 Two layers 30Lb. Roofing Felt 9’-6" (Precast Coping only), 5B1 Top of Coping Bars 4L @ 8" sp. STIRRUP BAR 5P BAR 4A rd960rh 134" 3" Cover Bar (The above concrete quantities are based on a max. superelevation of 6.25%, beneath a 32" F-Shape Traffic Railing on an MSE Wall). Maintain 2" minimum concrete cover. 7. Angle varies ~ 0 min., 20 max. F-SHAPE TRAFFIC RAILINGS LAST REVISION 01/01/12 REVISIO N 12/30/2011 114" 10 "R 5b " V2 Bars 5S 1’ -0" 5’-7" Sl o p e Va r i e s ( Se e No t e1 ) Bars 5V2 @ 8" sp. 6" 5’-7" 2" Cover (Top) Construction Joint Reqd. » ¿ 5’-7" Bars 4A @ 4" sp. 1’ -0" 5 3’ -3" ( 42" F-Shape) P 2’ -5" ( 32" F-Shape) expansion joints (Typ.) 30’ -0" M in. Length) N/A ( C-I-P Traffic Railing 4’-8" 3’ -6" ( 42" F-Shape) 5 or 8S1 (Typ.) 3 "Co v e r ( C-I-P or Precast Coping) C 1" Dowel Load 2’ -3" AS REQD. 2" m in. ) AS REQD. 114" AS REQD. " 5 »¿ (1’1˘ B2 Bars 5S » ¿ for Precast Coping (42" F-Shape) »¿ 3b " 9" 3" (32" F-Shape) 8" 9’-6" 8b " N/A 1 1 2" 3 4" 11’-6" Bars 5P @ 8" sp. 3" 4 5 Optional Bar 5C @ 8" sp. »¿ 1’- B1 (42" F-Shape) 8" 9" asphalt or See Note 3) (32" F-Shape) 3 4" " 8 5’-7" 6" 5’-7" 6" 4 Spacing Bars 8S1 (42" F-Shape) Pavement (Full depth 2’ -8" ( 42" F-Shape) 8’-0" BARS 4L 1’ -10" ( 32" F-Shape) Precast 7" C-I-P Spacing Bars 5S (32" F-Shape) 2’ -8" ( 32" F-Shape) Shoulder or Roadway 6 A 2" COPING PRECAST COPING & 32" F-SHAPE SIZE 3" MARK 1’ -0" »¿ 3b " »¿1’- (C-I-P Junction Slab) 3 4" LENGTH 1034" 5" Varies 8" 5’-0" Cover BILL OF REINFORCING STEEL DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 3 4 ~ Bars 5F 3s p. @ (Top of Slab) b" V-Groove Bars 5C @ 8" sp. 3" (Required only Bars 5B2 6" 2" Cover (Tie to Bars 4A) 4L Bars @ (See Detail "A" Sides (Typ.) (Typ.) 8" sp. (Typ.) & Note 7, Sheet 1) Expansion Joint (See Expansion 1" Dowel Load Joint Detail & Detail "A") Transfer Devices when Junction Slab is skewed) Field cut reinforcement as required to maintain minimum concrete Approach Slab (See Note 12 C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-4of6. dgn Sheet 1) Begin or End Skew Bars 7P1 & Bars 4L @ 8" (Typ.) Approach Slab 4V1 as required Bars 4A @ 4" (Typ.) " Open Jt. 5’-0" End Post Bars 7P1 & 4V1 (Typ.) Gutter Line Bars 5B1 Coping Line Bars 7P1 & 4V1 (Typ.) Varies 2’-6" (Typ.) 5’-0" Interior Post (Typ.) 2’-6" (Typ.) (2’-6" Min., 5’-0" Max.) Varies ~ 5’-0" (Typ.) 5’-0" End Post 5’-0" End Post (2’-6" Min., 5’-0" Max.) @ Expansion Joint @ Expansion Joint 2" Cover @ » Open Joints b" V-Groove Spacing ~ 30’-0" Max. (See Note 7, Sheet 1) " Open Joint in Precast Coping and C-I-P Traffic Railing to coincide with »¿˘" Expansion Joint Spacing ~ 30’-0" Min., 90’-0" Max. (See Note 5, Shee " Expansion Joint in Junction Slab. PLAN VIEW (Skewed Approach Slab shown, Perpendicular Approach Slab similar) (Precast Coping shown, C-I-P Coping similar) CROSS REFERENCES: 1. For Detail "A" see Sheet 2. (Traffic Railing reinforcement not shown, except for Bars 7P1 & 4V1) 2. For "Expansion Joint Detail" see Sheet 1. 3. For "Junction Slab Notes" see Sheet 1. Bars 5B2 Bars 5C @ 8" sp. Bars 5C @ 8" sp. (Tie to Bars 4A) (Typ.) (Tie to Bars 4A) (Typ.) Bars 5B2 Guardrail Gutter Line Gutter Line 4b " Taper (Typ.) Face of Curb Bars 4L (Typ.) rd960rh Lap Splice 2’ -0" M in. cover (Typ.) Bars 4A (Typ.) Begin or End Retaining Wall Bars 7P1 & 4V1 (Typ.) Coping and 3’-0" Taper (Inside Face) Varies (12’-6" Min.) 3’-0" Taper Bars 4P5 (Typ.) Coping Line 2’-6" (Typ.) Bars 7P1 & 4V1 (Typ.) 5’-0" Interior Post (Typ.) Bars 4R3 (Typ.) 2’-6" (Typ.) Coping Line (Inside Face) PARTIAL PLAN VIEW OF GUARDRAIL TRANSITION AT BEGIN OR END RETAINING WALL PARTIAL PLAN VIEW OF COPING WITH CURB (Precast Coping shown, C-I-P Coping similar) (Precast Coping shown, C-I-P Coping similar) (Traffic Railing reinforcement not shown, except for Bars 7P1 & 4V1) (Traffic Railing reinforcement not shown, except for Bars 4P5, 4R3, 7P1 & 4V1) 12/30/2011 9: 34: 56 AM Bars 4L Bars 5B1 Bars 4A Traffic Railing REVISION 01/01/12 REVISIO N CORRAL SHAPE TRAFFIC RAILINGS LAST DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 4 »¿ Interior Post (C 4 " 11 " 5 " 8" " 3 ’ 6 b" 1 ’ 1 . p 5s . p 5s 3 " ’ 7 Guardrail Thrie Beam 1 6 4"– Joint permitted in rail) A) s4 r e Ba t a n r e t l oa et i T –( " d@ 8 e c a p V1 s P1 & 4 s7 r Ba – " 5 A C clear precast opening Top of C-I-P Traffic Railing D " @ 8 Bars 4S3 Shift Bars 4A & 4L to W-Beam similar ) b r Cu P5 ( s4 r g Ba n i c a Sp . p 2s – " 6 ’ 6 . p 2s " @ 8 attachment shown, – " 5 " @ 4 " @ 4 n o i t i s n a r lT i a r d r a Gu g n i c a p S t l Bo u r h T V1 P1 & 4 s7 r g Ba n i c a Sp b" V-Groove Curb (Precast ) . p y T P1 ( s7 r Ba permitted for or C-I-P) ) . p y T V1 ( s4 r Ba C-I-P Curb Bars 4P5 (Typ.) Bars 4R3 C-I-P Transition -3" 2’ Bars 4A (Typ.) Begin or End Retaining Wall A s e i r Va C Bars 4L (Typ.) ) . n "Mi 6 ’ 2 s( e i r Va D r e p a "T 0 ’ 3 Coping, and ) e c e Fa d i s n I ( Traffic Railing – " 4 4" r e p a "T 0 ’ 3 ) . x "Ma 6 ’ 2 ) e c e Fa d i s n I ( ) L 4 s r a B ( " 8 .@ p 4s A)& 1 s4 r Ba "( .@ 4 p 8s 2 4" t s r Po o i r e t n I ) L s4 r Ba "( .@ 8 p s 4 1 & ) A 4 s r a B "( .@ 4 p 8s 2 4" g n i p tCo s a c e lPr a c i p y "T 0 ’ 0 1 b r h Cu t wi . p "s L@ 8 s4 r .& Ba p "s A@ 4 s4 r Ba g n i p n Co o i t i s n a r nT i g "Be 0 ’ 0 1 4" " 6 ’ 2 " 6 ’ 2 ) . p y T "( 0 ’ 5 " 6 ’ 2 , . n "Mi 0 ’ 0 ( » " Open Joint in Precast Coping and Precast Curb g n i p n Co o i t i s n a r dT )En . n "Mi 6 ’ 8 s( e i r Va C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-5of6. dgn PARTIAL ELEVATION VIEW OF OUTSIDE FACE OF COPING (End Transition and Typical Precast Coping with Curb shown, C-I-P Coping similar) »¿ Interior Post (C Joint permitted in rail) »¿ Expansion Joi 6 " Begin/End Approch Slab » " Open Joint in V1 P1 & 4 s7 r g Ba n i c a Sp o t s r a b e t a n r e t l ea i T ( ) L r4 Ao s4 r Ba b" 4 V1 P1 & 4 s7 r Ba Coping & Traffic Railing " .@ 8 p 6s . p 5s . p 5s " @ 4 " @ 4 B Top of C-I-P Traffic Railing A ) . p y T P1 ( s7 r Ba ) . p y T V1 ( s4 r Ba Post (Precast or C-I-P) Top of Precast Coping Bars 4S3 (Typ.) Bars 4S3 (Typ.) Post (Precast or C-I-P) (Typ.) Bars 4L (Typ.) Bars 4A (Typ.) t s d Po "En 0 ’ 5 t s d Po "En 0 ’ 5 ) . p y T "( 0 ’ s~ 5 e i r Va ) t n i o .J p l@ Ex a c i p y T ( ) . x a M " 0 ’ 5 , . n "Mi 6 ’ 2 ( 4" ) . p y A "T 6 ’ 7 s( e i r g Va n i n e p tO s d Po En ) . x "Ma 6 ’ ,7 . n "Mi 0 ’ 5 ( ) . n "Mi 6 ’ 7 t( n i o nJ o i s n a p lEx a c i p y » " Open Joint "T 0 ’ 0 1 b r u C t u o h t g wi n i p tCo in Precast Coping s a c e Pr " -0 ’ 0 ,9 . n i "M 0 ’ 0 3 ~ g n i c a p s t n i o nJ o i s n a p x ˘ "E »¿ 9: 34: 57 AM rd960rh " 6 ’ 2 ) t n i o .J p l@ Ex a c i p y T ( ) . p y T "( 0 ’ s~ 5 e i r Va ) . x "Ma 0 ’ ,5 . n "Mi 6 ’ 2 ( " 6 ’ 2 4" ) L s4 r Ba "( .@ 8 p 4s A)& 1 s4 r Ba "( .@ 4 p 8s 2 t s r Po o i r e t n I 4" ) L s4 r Ba "( .@ 8 p 4s A)& 1 s4 r Ba "( .@ 4 p 8s 2 ) . n "Mi 6 ’ 7 t( n i o nJ o i s n a p lEx a c i p y "T 0 ’ 0 1 b r u C t u o h t g wi n i p tCo s a c e Pr " -0 ’ 0 ,9 . n i "M -0 ’ 0 g ~3 in c a p ts n i o nJ o i s n a p x ˘ "E »¿ " 6 ’ 2 " 6 ’ 2 ) . p y T "( 0 ’ 5 g n i p tCo s a c e lPr a c i p y "T 0 ’ 0 1 b r tCu u o h t wi » B " Open Joint in Precast Coping & Precast Curb NOTE: Wall Panels not shown for clarity. CROSS REFERENCES: 1. For Sections A-A, B-B, C-C & D-D, see PARTIAL ELEVATION VIEW OF OUTSIDE FACE OF COPING 12/30/2011 (Precast Coping at Expansion Joint and Typical Precast Coping without Curb shown, C-I-P Coping similar) Sheet 6. 2. For Junction Slab Notes, see Sheet 1. REVISION 01/01/12 REVISIO N CORRAL SHAPE TRAFFIC RAILINGS LAST DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 5 1’-6b" 1’-6b" Coping Gutter Line 1’-6b" Coping Gutter Line Coping Gutter Line Bars 4S3 Const. (See Note 4) Joint 1’-2" permitted (Corral Shape) 4 " Bars 7P1 (See Note 4) 1b " 1b " Curb Bars 4S3 Sealant Detail" Joint 1’-2" Bars 4P5 (See Note 4) See "Curb Joint Const. (See Note 4) ( Rail) C. I. P. Only Traffic Railing - (Corral Shape) C. I. P. Only 1b " Index No. 424 Traffic Railing - ( Post & Rail) (See Note 4) ( Rail) Bars 7P1 Index No. 424 ( Post) 4 " Precast (Corral Shape) or C. I. P. Traffic Railing - C. I. P. Only Index No. 424 1’-2" required 6" Precast 3b " or C.I.P. Curb Bars 4A 6" Bars 4A Bars 4A Embed. 6" 6" Embed. Embed. Bars 5C Bars 4V1 Bars 5B2 (See Note 4) Bars 5B2 Bars 5B1 (Typ.) Bars 4L Bars 5C Bars 5B2 Bars 4V1 Bars 4R3 (See Note 4) (See Note 4) Bars 4L Bars 4L See Sheet 2 Const. Joint permitted Bars 5B2 (Typ.) for Junction Slab and Bars 5B1 (Typ.) See Sheet 3 Precast Coping Details for Junction Slab and See Sheet 2 or 3 C.I.P. Coping Details for Junction Slab Trim Bars 4P5 as and Coping Details required to clear Const. Joint C: \d\projects\standards\structures\current\ready4release\2012book_draft\06110-6of6. dgn 1’-6b" Min. 1’-6b" Min. (See Note 3) SECTION A-A SECTION A-A (See Note 3) (TYPICAL SECTION C.I.P. COPING WITHOUT CURB) (TYPICAL SECTION PRECAST COPING WITHOUT CURB) SECTION B-B 1’-6b" 1’-6b" (TYPICAL SECTION WITH CURB) Coping Gutter Line Coping Gutter Line (Precast Coping Shown, C.I.P. Coping Similar) Index No. 424 Traffic Railing - Index No. 424 Traffic Railing - (Corral Shape) " 4 " 1b " 1b " Bars 7P1 (See Note 4) C. I. P. Only (See Note 4) C. I. P. Only 4b " Bars 7P1 ( Transition) (Corral Shape) ( Transition) 7 Top of Curb Low Modulus Silicone Sealant (Type A) JOINT NOTE: »¿˘" (T Joint sealant required at 4b" Taper Const. 4b" Taper Joint 11" 1’-2" Const. all expansion joints and Joint between precast and required C.I.P. curb openings. required " Preformed Expansion Bars 4A Joint Filler (See Detail "A" Bars 4A Sheet 2) 6" Embed. 1" Foam Bars 5C Bars 5C Bars 4V1 Bars 5B2 (See Note 4) Backer Rod Bars 4V1 Bars 5B2 2" (See Note 4) Bars 4L Min. Bars 4L Bars 5B1 (Typ.) rd960rh Bars 5B1 (Typ.) See Sheet 2 or 3 See Sheet 2 or 3 for Junction Slab for Junction Slab and Coping Details and Coping Details CURB JOINT SEALANT DETAIL NOTES: 9: 34: 58 AM 1. See Sheets 2 & 3 for Junction Slab and additional Coping details. 2. Slip Forming of C.I.P. Traffic Railiing is not permitted. 1’-6b" Min. 3. Actual width varies depending on type of Retaining Wall used. 1’-6b" Min. (See Note 3) 4. See Index No. 424 for Traffic Railing details and Bars 7P1, 4P5, 12/30/2011 (See Note 3) 4R3, 4S3 & 4V1. Bars 5R2 and 5U are not required in Retaining SECTION C-C END VIEW D-D (TYPICAL SECTION TRANSITION COPING) (TYPICAL SECTION TRANSITION COPING) (Precast Coping shown, C.I.P. Coping similar) (Precast Coping shown, C.I.P. Coping similar) Wall Coping. REVISION 01/01/12 REVISIO N CORRAL SHAPE TRAFFIC RAILINGS LAST DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/JUNCTION SLAB NO. 6110 SHEET NO. 6 b " V-Groove (See Bars 5B2 1" Dowel Load Transfer Devices (See Typical Sections Top of Raised for details) Sidewalk Note 6 & Detail "B") 2" Cover Bars 4C @ 6" sp. (tie Bars Sides (Typ.) 1" Dowel Load Expansion Joint (See Transfer Devices "Expansion Joint Detail " this sheet and Detail "B") 4C to Bars 5A) (Typ.) 4 ~ Bars 5F (Top of Slab) Approved metal (Required only or fiber cap when Raised Sidewalk is 3" Approach Slab 3s p. @ (See Note 10) 6" Lap Splice 2’ -0" M in. skewed) Edge of Precast Coping Gutter Line Bar 5T " Bottom of Raised Sidewalk " Preformed Expansion Bars 5L @ 6" sp. Joint Filler 1’-0" (tied to alternating Bars 5T and 5X) 1’-0" Field cut reinforcing »¿ Expansion & Precast or C-I-P Coping Spacing Bars EXPANSION JOINT DETAIL 1’-0" sp. (Typ.) minimum cover (Typ.) 2b " Bars 5A @ 6" sp. (tied to Bars 5U1) (Typ.) 6" Spacing (Typ.) (See Note 7) b " V-Groove Spacing 2" Cover @ 2" Cover @ Open Joints Expansion Joints 30’-0" Max. (See Note 6) »¿˘" Expansion Joint Spacing ~ 30’-0" Min., 90’-0" Max. (See Not »¿˘" Open J »¿ ˘" Open Jo PARTIAL PLAN VIEW FOR VERTICAL SHAPE TRAFFIC RAILING Precast Coping and (Skewed Approach Slab Shown, Perpendicular Approach Slab Similar) 1. »¿to coincide with Expansion Joint in APPLICATIONS: This raised sidewalk is only applicable for a TL-4 crash test rating. For TL-5 crash test rating increase Expansion Joint spacing to 60’-0" minimum and increase » Bars 4C to Bars 5C or provide Bars 4C @ 4" spacing with the 42" Vertical Shape Traffic Railing. 2. C-I-P Traffic Railing (Precast Coping Shown, C-I-P Coping Similar) (Traffic Railing not Shown for Clarity) RAISED SIDEWALK NOTES: " Open Joint in Precast Coping Top of C-I-P CONSTRUCTION REQUIREMENTS: Construct the raised sidewalk level transversely and Raised Sidewalk. g n i p tCo s a c e "Pr 0 ’ 0 1 n* o i t c g Se n i p d Co n ga n i l i c Ra i f f a r tT s a c e .Pr n "Mi 0 ’ 2 1 Traffic Railing Top of Precast Coping expansion joints plumb; do not construct the raised sidewalk or C-I-P coping perpendicular Top of Retaining 6. Wall Panel (Typ.) Provide and install Preformed Expansion Joint Filler in accordance with Specification 7. -3" 2’ Section 932. Construct b" V-Grooves in raised sidewalk and C-I-P coping plumb and provide at »¿ 30’-0" maximum intervals as shown. Space V-Grooves equally between ˘" Expan Joints and/or Begin or End Raised Sidewalk. V-Groove locations are to coincide with 2" Cover M in. Construct ˘" Expansion Joints in raised sidewalk and C-I-P copings plumb and perpendic or radial to the Gutter Line. Provide at 90’-0" maximum intervals as shown. Railing C-I-P Buildup Concrete Coping Top of recessed Transfer Devices in accordance with Specification Section 350. »¿5. Varies Dowel Load Transfer Devices will be ASTM A 36 smooth round bar and hot-dip galvanized in accordance with Specification Section 962. Install Dowel Load ( 1’ -0" M ax. ) 4. C-I-P Traffic Provide Class II concrete for slightly aggressive environments or Class IV for moderately or extremely aggressive environments. Precast to the roadway surface. Slip forming of coping and/or raised sidewalk is not permitted. 3. V-Groove locations in the Traffic Railing. 8. Spacing shown is along the Gutter Line. 9. For MSE Walls, provide Dowel Bars 4D and extend 8" above the top of retaining wall panel. Clearance Varies Field cut as necessary to maintain 2" minimum cover to the top of the buildup concrete. rd960rh (Typ.) Bars 5B1 5T and 5X @ in Precast Coping Varies C: \d\projects\standards\structures\current\ready4release\2012book_draft\06120-1of3. dgn " open joints in Traffic Railing) Bars 5S 5T and 5X (Raised Sidewalk expansion joints are to coincide with as required to maintain Begin or End Retaining Wall Coping Alternating Bars " Open Joint See Wall Company Drawings for number and spacing of Dowel Bars 4D. 10. Finish Sidewalks in accordance with Specification Section 522. Bottom of Dowels 4D (Typ.) Precast Coping (See Note 9) 11. Work this Index with the following: Index No. 422 - Traffic Railing - (42" Vertical Shape) 9: 34: 59 AM Index No. 423 - Traffic Railing - (32" Vertical Shape) 12. The following Indexes contain details of the intersection of the retaining wall at approach slabs: Index No. 20900 - Approach Slabs (Flexible Pavement Approaches) PARTIAL ELEVATION VIEW Retaining Wall (MSE Wall shown, other types similar) (Precast Coping & Raised Sidewalk Reinforcing not Shown for Clarity) CROSS REFERENCE: For Detail "B", see Sheet 2. (Precast Coping Shown, C-I-P Coping Similar) * C-I-P End Section must be = 12’-0". LAST REVISION 01/01/12 REVISIO N 12/30/2011 Index No. 20910 - Approach Slabs (Rigid Pavement Approaches) DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/RAISED SIDEWALK NO. 6120 SHEET NO. 1 1’-3" 11" 42" Vertical Shape 7’-9" 32" Vertical Shape 5’-11" (C-I-P Raised Sidewalk) (See Note 2) Top of Precast Coping 1’-10" (Shown dashed) (Precast Coping) C-I-P Traffic 4" Taper Railing Transition Bars 5X 9" 1’-1" 32" Vertical Shape 7" 1’-3" 42" Vertical Shape Bullet Railing (Not required for 42" Coping (Alternate with Bars 5T) (See Note 3) (42" Vertical Shape similar) Transition Precast Coping PARTIAL END VIEW OF TRAFFIC RAILING END Top of Travel TRANSITION FOR GUARDRAIL ATTACHMENT Lane or Shoulder (Showing Bars 5S, Bars 5T and Bars 5X) Top of (Precast Coping Shown, C-I-P Coping Similar) Precast Coping Coping ( 6" M ax. )( See Note 2) Curb H eight Varies Bars 5T 1" Dowel Load Top of Precast Coping Transfer Devices Bars 5T @ 1’-0" sp. at Expansion Joints (Alternate with Bars Bars 5A @ 6" sp. 5X) (See Note 3) (lap with Bars 5C) Bars 4C @ 6" sp. (lap with Bars 5A) 5" Bars 5S (See Note 3) Ft / 2 Ft 0 :. e p o Sl 2" Top of See Note 4 3’ -6" ~ 42" Vertical Shape Bars 5X @ 1’-0" sp. (32" Vertical Shape shown) Coping ( C-I-P or Precast Traffic Railing) Gutter Line C-I-P Traffic Railing 2’ -8" ~ 32" Vertical Shape 6" M in. Bars 5S Em bed. Vertical Shape Pedestrian Railing) UNIT QUANTITY CY/LF 0.091 Bars 5B2 @ Expansion Joint Filler 1’-0" sp. (Typ.) Bars 5L @ 1’-0" sp. 2’ -3" Precast Coping ITEM b " Preformed (Typ.) 6" ESTIMATED QUANTITIES FOR PRECAST COPING 2" Min. Cover 6" 6" M in. Bars 5B1 3" Cover Two Layers 30Lb. Roofing Felt Varies Optional extension for Precast Coping » ¿ C: \d\projects\standards\structures\current\ready4release\2012book_draft\06120-2of3. dgn 1’ -1b " » ¿ NOTE: See Index No. 422 and Index No. 423, Railing End Detail for details. (2" min.) Dowel Bars 4D Concrete (Precast Coping) (MSE Walls only) Spacing Concrete (C-I-P Raised Sidewalk) CY/LF 5b" C.I.P Buildup Concrete 5 sp. @ 1’-0" = 5’-0" Spacing (MSE Walls only) Bars 5B1 1" Dowels 0.232 Retaining Wall Spacing Reinforcing Steel (Precast Coping) excluding Bars 5T, 5X and 5S (Typ.) LB 22.00 LB/LF 11.92 LB 32.04 5b" 5 sp. @ 1’-0" = 5’-0" (5B2) 6" 312" 2 sp. @ 8" (Type Varies) = 1’-4" (5B1) Bars 5B 1 4" 5 Reinforcing Steel (C-I-P Raised Sidewalk) (Typ.) » Additional Reinf. @ Expansion Joints Smooth or Textured Face of Wall The above concrete quantities are based on a Type D TYPICAL SECTION THRU PRECAST COPING WITH C-I-P RAISED SIDEWALK Concrete Curb (See Note 2). AND RETAINING WALL AT EXPANSION JOINTS b " V-Groove (Typ.) NOTES: b" V-Groove (Typ.) 1. Actual width varies depending on type of Retaining Wall used. rd960rh 2. Match roadway curb shape (Type) and height. See Roadway Plans and Index No. 300. 5’-11" dimension is based on a 32" Vertical Shape Traffic Railing with a Type D curb adjacent to a 6’-0" wide sidewalk. Adjust this »¿˘" Preformed Expans »¿˘" Preformed Expans Joint Filler Joint Filler dimension as required for other curb types or transitions at Begin or End Retaining Wall. 3. See Index No. 422 and Index No. 423 for Bars 5S, 5T & 5X and Bullet Railing details. Adjust vertical dimension 9: 35: 00 AM of Bars 5T and 5X, see Reinforcing Steel Note 5. 4. Trim end of Bars 5T and 5X to clear construction joint for 42" Vertical Shape Traffic Railing. 5. At the Contractor’s option, mechanical couplers may be used to splice reinforcing. Complete details, including reinforcement lengths are required in the Shop Drawings. Mechanical couplers shall develop 125% of the bar PRECAST COPING C-I-P COPING 12/30/2011 DETAIL "B" LAST REVISION 01/01/12 REVISIO N (Showing Locations of b " V-Grooves and yield strength. 6. Contractor to maintain stability of precast coping prior to junction slab completion. " Preformed Expansion Joint Filler) DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/RAISED SIDEWALK NO. 6120 SHEET NO. 2 REINFORCING STEEL BENDING DIAGRAMS - RAISED SIDEWALK 7’-9" BILL OF REINFORCING STEEL LENGTH 5B1 Bullet Railing Precast Traffic Railing/Coping ~ 11’-6" 5B2 Gutter Line Length as Required Bars 5X @ 1’-0" sp. C-I-P Traffic Railing 9’-6"/11’-6" B2 5 AS REQD. C 4 5’-5" 5F F 5 5’-0" AS REQD. 5’-0" N/A BARS 5B1, 5B2, 5C & 5F 5’-0" 2’-0" L 5 4’-5" 4’-5" Smooth Steel Bar 2’-0" 2’-0" Top of C-I-P 1" Dowel Coping 1’ -1b " 1" DOWEL Precast Coping ~ 3’-9" (See Note 6) 5T) (See Note 2) (42" Vertical Shape similar) (See Note 7) N/A (Alternate with Bars (32" Vertical Shape shown) Precast Coping ~ 5’-5" Coping Top of C-I-P Coping (Const. Joint Required) Bars 5T @ 1’-0" sp. (Alternate with Bars 5X) (See Note 2) Bars 5A @ 6" sp. Top of Travel 5" Lane or Shoulder Bars 5S Bars 5B2 @ 1’-0" sp. (Typ.) 2" (See Note 2) Ft / 2 Ft 0 :. e p o Sl Top of Coping 2" Cover 3’-9" (Top & Sides) 6" 5 5C ( 6" M ax. )( See Note 1) B1 8’-4" Curb H eight Varies 4’-10" 6" 5 ( M in. ) A 3" Cover C-I-P Coping ~ 7’-3" b " Preformed 8" Expanded Polystyrene (b" Side) Joint Filler 5b " Spacing BAR 5A BAR 5L Two Layers 30Lb. Roofing Felt Expansion Joints (Typ.) Expansion » ¿ 90 1’ -1" 5 sp. @ 1’-0" = 5’-0" Spacing 1" Dowels Bars 5B2 Retaining Wall REINFORCING STEEL NOTES: Varies (Type Varies) 5b " 1. All bar dimensions in the bending diagrams are out to out. Spacing 2. All reinforcing steel at expansion joints will have a 2" minimum cover. Bars 5B2 312" 7 sp. @ 1’-0" = 7’-0" 6" 3. Lap splices for Bars 5B will be a minimum of 2’-2". 4. Lap splice Bars 5A with Bars 5C. Lap splices will be a minimum of 2’-2". »¿(1’-1˘" Max., 2" M Smooth or Textured Face of Wall TYPICAL SECTION THRU C-I-P COPING AND RAISED SIDEWALK 5. See Index No. 422 and Index No. 423 for Bars 5S, 5T and 5X. Adjust vertical AND RETAINING WALL AT EXPANSION JOINTS dimensions of Stirrup Bars 5T and 5X to 3’-0" for 32" Vertical Shape or 3’-10" Construction Joint Permitted for 42" Vertical Shape. Optional Keyway 6. Dimension shown is for lap splice option. For mechanical coupler option, this dimension is 1’-8". Buildup for 7. Dimension shown is for lap splice option. For mechanical coupler option, this dimension stepped MSE is 5’-8". 2" 6" Welded Wire Reinforcement will conform to ASTM A 497. 45 M in. Wall Panels 8. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. M ax. C: \d\projects\standards\structures\current\ready4release\2012book_draft\06120-3of3. dgn Transfer Devices at 6" Bars 5L @ 1’-0" sp. 1" Dowel Load (0" min., »¿11˘" m Coping Expanded Polystyrene (b") ESTIMATED QUANTITIES FOR C-I-P COPING 6" BUILDUP FOR STEPPED MSE WALL PANELS rd960rh ITEM Concrete UNIT QUANTITY CY/LF 0.322 AND C-I-P COPING NOTES: 1. Match roadway curb shape (Type) and height. See Roadway Plans and Index No. 300. 6’-8" dimension is based Bars 5T, 5X and 5S (Typ.) on a 32" Vertical Shape Traffic Railing with a Type D curb adjacent to a 6’-0" wide sidewalk. Adjust this dimension LB/LF 28.85 as required for other curb types or transitions at Begin or End Retaining Wall. 2. See Index No. 422 and Index No. 423 for Bars 5S, 5T & 5X and Bullet Railing details. Adjust vertical dimension of Additional Reinf. @ Expansion Joints LB 32.04 Bars 5T and 5X, see Reinforcing Steel Note 5. The above concrete quantities are based on a Type D Concrete Curb on an MSE Wall (See Note 1). LAST REVISION 01/01/12 REVISIO N 12/30/2011 9: 35: 01 AM Reinforcing Steel (Typical) excluding DESCRIPTION: FDOT DESIGN STANDARDS FY 2012/2013 INDEX WALL COPING WITH TRAFFIC RAILING/RAISED SIDEWALK NO. 6120 SHEET NO. 3 ( C-I-P Traffic Railing) COPING/ COPING RAILING 42" Vertical Shape Precast Coping ~ 9’-6" 3’ -6" ~ 42" Vertical Shape C-I-P 2’ -8" ~ 32" Vertical Shape PRECAST 32" Vertical Shape 1’-3" 2’ -3" C-I-P Coping SIZE 1’-1" 6’-6" » ¿ MARK 6’-8" Bars 5B2 b " V-Groove (Typ.) b " V-Groove (See 2" Cover Bars 5A @ 1’-0" sp. Note 3 & Detail "C") Sides (Typ.) (tied to Bars 5L (Typ.) Approach Slab (See Note 8) " Preformed Expansion Joint Filler 2’ -2" M in. b " V-Groove (Typ.) Lap Splice PRECAST COPING Edge of " Preformed Precast Expansion Joint Filler Coping C-I-P COPING DETAIL "C" (Showing Locations of b " V-Grooves and Field cut reinforcing as required " Open Joint " Preformed Expansion Joint Filler) " Open Joint to maintain minimum cover (Typ.) Spacing Bars 4P 5b " 1’-0" Spacing (Typ.) (See Note 4) 30’-0" Max. (See Note 3) Bars 5B1 (tied to Bars 4P) (Typ.) 2" Cover @ Open Joints Expansion Joints Begin or End Retaining " Expansion Joint Spacing ~ 50’-0" Min., 90’-0" Max. (See Note 1) Wall, Precast Coping/ Parapet or C-I-P Coping PARTIAL PLAN VIEW (Skewed Approach Slab Shown, Perpendicular Approach Slab Similar) (Precast Coping Shown, C-I-P Coping Similar) (Concrete Parapet not Shown for Clarity) PRECAST COPING/PARAPET AND SIDEWALK NOTES: » 1. Provide Class II concrete for slightly aggressive environments or Class IV for moderately or extremely aggressive environments. » " Open Joint in Precast Coping and " Open Joint in Concrete Parapet ) . n "Mi 0 ’ 5 t( e p a r e Pa t e r c n g & Co n i p tCo s a c e lPr a c i p y "T 0 ’ 0 1 Precast Coping and Concrete Parapet »¿2. Construct ˘" Expansion Joints in sidewalk and C-I-P coping plumb to coincide with " Expansion Joint in Sidewalk perpendicular or radial to the Gutter Line. Provide at 90’-0" maximum intervals as shown. 3. Provide and install Preformed Expansion Joint Filler in accordance with Top of Precast Concrete Parapet 5. Spacing shown is along the Gutter Line. Top of Retaining Wall Panel (Typ.) 6. For Precast Coping only, Dowel Bars 4D are to extend 1’-0" above the top of retaining wall panel. Field cut as necessary to maintain 2" minimum cover and spacing of Dowel Bars 4D. Parapet Concrete -3" 2’ to the top of the buildup concrete. See Wall Company Drawings for number Top of C-I-P Buildup Concrete Coping in the Concrete Parapet. Coping -0" 2’ Coping only, V-Groove locations are to coincide with V-Groove locations Top of Precast Precast between ˘" Expansion Joints and/or Begin or End Sidewalk. For C ( 1’ -0" M ax. ) provide at 30’-0" maximum intervals as shown. Space V-Grooves equally »¿ Varies 4. Construct b" V-Grooves in sidewalk and C-I-P coping plumb and Precast Specification Section 932. 2" Cover M in. C: \d\projects\standards\structures\current\ready4release\2012book_draft\06130-1of2. dgn Coping (tied to Bars 5U1) (Typ.) Bars 5U1 @ 1’-0" sp. 2" Cover @ b " V-Groove Spacing Bars 5L @ 1’-0" sp. Bars 4P1 (Typ.) in Precast Coping 7. Work this Index with the following: Index No. 410 - Concrete Barrier Wall 9: 35: 02 AM rd960rh 8. For C-I-P Coping only, work this Index with the following: Bottom of Index No. 820 - Pedestrian/Bicycle Railing. Precast Coping 9. Finish Sidewalks in accordance with Specifications Section 522. 10. The following Indexes contain details of the intersection of the retaining Clearance Retaining Wall Varies (MSE Wall shown wall at approach slabs: Dowel Bars 4D Index No. 20900 - Approach Slabs (Flexible Pavement Approaches) (Typ.) (See Note 5) other types similar) Index No. 20910 - Approach Slabs (Rigid Pavement Approaches) PARTIAL ELEVATION VIEW 12/30/2011 (Precast Coping and Sidewalk Reinforcing not Shown for Clarity) LAST REVISION 01/01/11 REVISIO N (Precast Coping Shown, C-I-P Coping Similar) DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 WALL COPING/PARAPET WITH C-I-P SIDEWALK NO. 6130 SHEET NO. 1 REINFORCING STEEL BENDING DIAGRAMS - COPING/PARAPET AND SIDEWALK Coping Line Sidewalk 5’-0" Min. Clearance BILL OF REINFORCING STEEL 8" Pedestrian/Bicycle Railing 1b " Spacing Bars 4S1 MARK SIZE A 5 B1 5 9’-6" B2 5 AS REQD. D 4 2’-0" L 5 P1 4 5’-5" N/A S1 4 9’-6" N/A U1 5 (Typ.) 1’-0" sp. 2’-2" Min. (Typ.) Lap Splice Riding Surface 6" Sidewalk See Detail "D" Bars 5B1 (Typ.) Top of Coping 9" (See Note 5) Bars 5L @ 1’-0" sp. Bars 5B2 Spread Footing (See @ 1’-0" sp. Index No. 410 for details) Max. (Typ.) Bars 5U1 @ 1’-0" sp. 1’ -3" Fill 3" 2 sp. @ 10"– Dowels 4D COPING COPING VARIES N/A Varies 15 Max. C-I-P Buildup Concrete " Subbase. Length as Required 4S1 Precast Coping ~ 9’-6" (See Wall Company ( b " Min. ~ 2b " Max.) 6" Min. TYPICAL SECTION THRU PRECAST COPING/PARAPET WITH C-I-P SIDEWALK Drawings for Details) 6" N/A VARIES BARS 5A, 5B1, 5B2 & 4S1 N/A 7" Retaining Wall Panel " Std. Panel width + 1’-0" Smooth or Min. See Note 1 BAR 5L Textured Face BAR 4P1 BAR 5U1 of Wall AND RETAINING WALL (MSE Wall Shown, other Wall Types Similar) REINFORCING STEEL NOTES: 1. All bar dimensions in the bending diagrams are out to out. Pedestrian/Bicycle Railing 2. All reinforcing steel at expansion joints will have a 2" minimum cover. 3. Lap splices for Bars 5B2 will be a minimum of 2’-2". Concrete 4. For Precast Coping only, lap splice Bars 5L with Bars 5A. Lap splices will be a minimum Barrier Wall Coping of 2’-2". 5. For C-I-P only, see Index No. 820 for Bars 4P and 4S. Sidewalk ~ 5’-0" Min. Clearance Gutter Line 6. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Bars 4P @ Welded Wire Reinforcement must conform to ASTM A 497. 1’-0" sp. Back of Concrete C-I-P Concrete Parapet Barrier Wall (See Index No. 820 & Note 4) ( Se e No t e2 ) (Typ.) Top of C-I-P Coping/Sidewalk (Const. Joint Required) Bars 5L @ 1’-0" sp. 1b " Riding Surface 6" Sidewalk See Detail "D" (See Note 5) Top of Coping Barrier Wall (Typ.) Varies (2" Min.) 6" 15 Max. Min. 9: 35: 03 AM (Typ.) It is the Contractor’s responsibility to Seal with Poured PRECAST COPING/PARAPET AND SIDEWALK NOTES: Rubber or Low 1. Actual width varies depending on type of Retaining Modulus Silicone Sealant (Top) & Expanded Polystyrene minimum of 2" below the Stabilized shown hatched (b" Side) Wall used. 2. Match Cross Slope of Travel Lane or Shoulder. 3. Gradually deflect/displace Soil Reinforcement downward as required. Soil Reinforcement is shown deflected downward for illustrative purposes only and is not to Sidewalk scale. See Wall Company Drawings for details. 4. Concrete Parapet shown, Concrete Pedestrian/Bicycle Railing (Index No. 825 & 826) similar. Complete details and dimensions of Concrete Pedestrian/Bicycle Varies (1’-3" b " Preformed Max., 2" Min.) Expansion Joint Filler Railing are required in the Shop Drawings. 5. Match cross slope of connecting sidewalk or as shown in the Wall Control Drawings. Two Layers 30Lb. Roofing Felt ensure Soil Reinforcement is placed a Retaining Wall Panel DETAIL "D" (See Wall Company Drawings for Details) Subbase. 12/30/2011 5" See Note 3 Bars 5B2 Stabilized Subbase 1’-0" sp. Max. Spacing rd960rh Index No. 410 for details) 2’ -0" Bars 5B2 @ Spread Footing (See Recess 6" 45 Fill 1’ -3" M ax. 6" 10"– Back of Concrete " 2" Cover C-I-P Coping Sl o p e Va r i e s Varies Roadway Pavement 3" M in. Shoulder or 6" C: \d\projects\standards\structures\current\ready4release\2012book_draft\06130-2of2. dgn (Depth Varies ~ 1’-0" Max.) See Note 3 ensure Soil Reinforcement is placed a minimum of 2" below the Stabilized 5B2 4" Spacing Bars 5B1 It is the Contractor’s responsibility to Precast Coping ~ 9’-6" AS REQD. VARIES (1’-3" Max., 2" Min.) (Typ.) N/A VARIES Varies Varies (2" Min.) Stabilized Subbase 5B1 1’ -8" ( Se e No t e2 ) 2’ -0" Bars 5A @ 6" 3" 2" Cover C-I-P 2’ -7" Bars 4S1 Sl o p e Va r i e s PRECAST C-I-P Coping 2" Min. Cover (Typ.) Recess Barrier Wall Roadway Pavement 1’ -0" Back of Concrete Precast Coping 2’ -3" ~ Precast 1’-0" sp. Concrete Parapet ( See Note 4) Bars 4P1 @ Shoulder or Precast Coping ~ Varies 1’ -8" Barrier Wall Precast Coping 3" Concrete Gutter Line 5A LENGTH TYPICAL SECTION THRU C-I-P COPING WITH C-I-P SIDEWALK Se e No t e1 LAST REVISION 01/01/12 REVISIO N AND RETAINING WALL (MSE Wall Shown, other Wall Types Similar) DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 WALL COPING/PARAPET WITH C-I-P SIDEWALK NO. 6130 SHEET NO. 2 LIGHT PEDESTAL NOTES: 1. The pedestal and junction slab are designed to resist the following working loads from the light pole applied at the top of the Pedestal: 6’-5" Min. (Pull Box Side) (See Note 9) Axial Deadload = Wind load Moment about Transverse Axis (*) = 40.60 kip-ft Wind load Moment about Longitudinal Axis (*) = 28.30 kip-ft Dead load Moment about Longitudinal Axis (*) = 1.690 kip-ft Maximum Shear = 1.380 kip Torsion about Pole Axis = 3.560 kip-ft (*) 4’-6" Min. (See Note 9) Varies (Transition to Varies (Transition to 1’-9" Thick Junction Slab) 1’-9" Thick Junction Slab) 1.560 kip - Axis refers to Bridge Axis. 2. See Index No. 21200 for anchor bolt design and notes. 3. The Contractor is responsible for ensuring the anchor bolt design is compatible with the light pole base plate. Modifications to the anchor bolt design must be signed and sealed by the Contractor’s Specialty Engineer and submitted to the Engineer for approval prior to construction. Junction Slab Junction Slab Length of 1’-6" Thick Junction Slab ~ 7’-6" 4. Install Anchor Bolts plumb. 5. For conduit, pull box and expansion/deflection fitting details, see Utility Conduit Detail Drawings. 6. 12 Bars 4J & 4M1 (Top & Bottom) @ 8"– The cost of anchor bolts, nuts, washers and anchor plates will be included in the Bid Price for Light Poles. Include the cost of all labor, concrete and reinforcing steel required for construction of the pedestals, pull boxes and miscellaneous hardware required for the completion of the electrical Bars 5B3 system in the Bid Price for either the Traffic Railing or Concrete Parapet that the pedestal is Field Cut Bars 4M2 as required to maintain clearance. Bars 4J 8. Anchor Bolt pattern orientation will be as shown. & 4M1 9. Slip Forming Method of construction requires the Engineer’s approval within the limits shown. 10. Reinforcing shown for light pole pedestals is in addition to typical reinforcing for C-I-P Junction Slabs and Raised Sidewalks. Bars 5B3 spaced @ 11. Work this Index with the following as appropriate: Index No. 6110 Index No. 6120 Index No. 6130 Construction 2 ~ 2" Conduits Gutter Line (shown) or Front Face of Concrete Parapet 1’ -8" Joint Spacing for Bars (See Note 5) 4G4 & 4G5 ( pairs) 12. For Estimated Quantities, see Sheet No. 3. »¿ Pul Traffic Railing or Concrete Parapet 1 ~ 1b " Conduit 912" »¿ Light Bars 4H Anchor Bolt Circle 2" Cover (Typ.) 1’-1b " (See Note 8) 2’ -6" Bars 4M2 (See Note 7) Bars 4G4 (pairs) 3 sp. @ Bars 4G1 (pairs) Bars 4G3 (pairs) (Typ.) C-I-P Pedestal 6" Bars 4G2 (pairs) (Typ.) 1’ -1b " C: \d\projects\standards\structures\current\ready4release\2012book_draft\06200-1of3. dgn 1’ -0" behind. 7. Coping Bars 4G5 (pairs) 2 sp. @ 6" rd960rh 2 sp. @ 6" 1’-1" Spacing for Bars 5" 5 sp. @ 6" 5" 1’-1" 4G1, 4G2, 4G3 & 4M2 2’-6" 2’-6" 2’-6" »¿ Expansion Joi Junction Slab, Raised 9: 35: 04 AM »¿ C-I-P Pedestal & Lig 4’-6" Min. Sidewalk or Sidewalk PLAN VIEW 12/30/2011 (Junction Slab reinforcing not shown for clarity) LAST REVISION 01/01/11 REVISIO N (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 COPING MOUNTED LIGHT POLE PEDESTAL NO. 6200 SHEET NO. 1 9’-0b" 1’-6b " 5’-0" 2’-6" 1’-4b " 1’-1b " C-I-P Traffic Railing (32" F-Shape Shown, Other Traffic Railings Similar) Coping »¿ Light Gutter Line (shown) or Front Face of Concrete Parapet 1b " Conduit 2" Conduits Top of Junction Slab, Bars 5V2 @ 8" sp. Raised Sidewalk or Sidewalk (See Note 4) Top of C-I-P Coping (See Note 6) (Const. Joint Required) Slope C-I-P Pedestal Surface Shoulder or Riding Surface Roadway Pavement Longitudinally with Profile Grade " ( Se e No t e4 ) 1 Bars 4G1 (pairs) " Elevation (Typ.) 2’ -0" 6" Bars 4G5 (pairs) C-I-P Pedestal 6" Bars 5B3 Spacing Bars 4M1 4" Cover (Bottom) @ 8" sp. 2" Cover (Top & Sides) 3" Bars 4H1 Bars 5B3 1’ -9" Bars 4H2 ( See Note 2) C: \d\projects\standards\structures\current\ready4release\2012book_draft\06200-2of3. dgn Top of Coping Bars 4G4 (pairs) » ¿ 1 Bars 5S (See Note 6) Sl o p e Va r i e s Varies Construction »¿(1’-1˘" Max., 3" M Joint Bars 4M2 @ 6" sp. Permitted Bars 4J @ 8"– sp. (tie to Alternate Bars 4A Bars 4G4 (pairs) (Typ.) in Junction Slab) (See Note 3) Retaining Wall 3" Min. Two Layers 30Lb. Roofing Felt (Type Varies) Expanded Polystyrene shown 4 sp. @ 1’-0" = 4’-0" Spacing hatched (b" Each Side) Bars 5B3 See 6" Note 5 Smooth or Textured Face of Retaining Wall TYPICAL SECTION AT LIGHT POLE PEDESTAL (Traffic Railing Shown, Concrete Parapet Similar) (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) rd960rh NOTES: 1. Provide Concrete Class to match adjacent coping. 2. For junction slabs, increase the 1’-0" depth dimension to 1’-9". For sidewalks see Index No. 6130 for C-I-P Coping, but increase 6" depth dimension to 1’-6". The minimum length of the Junction Slabs, Raised sidewalks and Sidewalks is 9: 35: 10 AM 30’-0", measured along the Gutter Line. 3. Bars 4J are only required when pedestals are behind a Traffic Railing. 4. Match the slope of the adjoining junction slab and shoulder or roadway pavement, raised sidewalk or sidewalk. Actual width varies depending on type of Retaining Wall used. 6. See Index No. 6110 for Bars 5V2 and 5S. LAST REVISION 01/01/12 REVISIO N 12/30/2011 5. DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 COPING MOUNTED LIGHT POLE PEDESTAL NO. 6200 SHEET NO. 2 REINFORCING STEEL BENDING DIAGRAMS - LIGHT POLE PEDESTAL 5’-0" Max. (Left or Right) 5 7 7’-2" G1 4 16 5’-8" G2 4 4 4’-8" G3 4 4 4’-2" G4 4 6 8’-10" G5 4 4 7’-4" H1 4 3 9’-8" H2 4 2 13’-8" J 4 12 6’-0" M1 4 12 5’-10" M2 4 10 3’-8" 2’ -0" 3" – @ Wall Coping 2’-6" Varies (Transition to BAR 4H2 2’-7" 7’-6" (Length of 1’-6" Thick Junction Slab) Junction Slab Minimum Limits of C-I-P Coping 2’-6" 4G1 2’-0" 4G2 1’-9" 4G3 3’-8" 4G4 2’-11" 4G5 ELEVATION VIEW (Junction Slab Reinforcing & Bars 4J not Shown for Clarity) (Traffic Railing Shown, Concrete Parapet Similar) 4G4 & 4G5 Junction Slab 2’-4" 2’-7" BAR 4H1 1’-9" Thick Junction Slab) 4G1, 4G2 & 4G3 1’-9" Thick Junction Slab) 2’-7" 4M1 5’-0" 4M2 2’-2" 10" (Junction Slab Shown, Raised Sidewalk or Sidewalk Similar) 1b " Conduit 4M 2 2’-6" Bottom of MSE (See Note 1) 2’-4" 4M 1 2’-6" Varies (Transition to Bars 4M2 2’-7" 1’ -5b " 2" Cover (Top & sides) BARS 5B3 & 4J 1’ -6" Bottom of Thickened Junction Slab 7b " (pairs) (Typ.) 4" Cover (Bottom) BARS 4G1, 4G2, 4G3, Light Pole Wire Screen NOTES: (See Spec. 649-6) 1. Field Cut Bars 4M2 as required to maintain minimum cover. 2" Conduit Light Pole Base 4G4 & 4G5 (See Note 2) REINFORCING STEEL NOTES: 1. All bar dimensions in the bending diagrams are out to out. 2. Lap splices for Bars 4G1, 4G2 & 4G3 will be a minimum of 1’-4". Lap Dia. M ax. Leveling Nut BAR 4M1 & 4M2 2. Maximum clearance between leveling nut and top of pedestal will not exceed anchor bolt diameter. Plate (Level) 1 ~ Bolt C: \d\projects\standards\structures\current\ready4release\2012book_draft\06200-3of3. dgn Bars 4H1 Bars 4G4 Bottom of C-I-P Pedestal 6’-0" 2’ -7" 45 (Typ.) Varies Bars 4G5 (pairs) (Typ.) 2b " Bars 4G3 (pairs) (Typ.) Junction Slab 3 sp. (pairs) Coping) Bars 4G1 Bars 4G2 (pairs) (Typ.) Top of recess & Bottom of 6" Bars 4H2 2’ -3" See Detail "A" 2" Conduit ( C-I-P/Precast 1b " Conduit ( C-I-P Pedestal) Spacing Bars 4H »¿ Pul 4J 2’ -0" B3 2’ -7" SIZE 2’ -7" NO. REQD. LENGTH MARK »¿and Light 7’-2" 2’ -0" Top of Traffic Railing »¿ C-I-P Pede 5B3 2’ -7" BILL OF REINFORCING STEEL splices for Bars 4G4 & 4G5 will be a minimum of 1’-8". 3. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded Wire Reinforcement will conform to ASTM A 497. ESTIMATED QUANTITIES ITEM UNIT QUANTITY Concrete (Pedestal) CY 0.926 Concrete (Thickened Junction Slab) CY 1.222 Reinforcing Steel LB 349 Washer Slope C-I-P Pedestal (Typ.) rd960rh Surface Longitudinally with Profile Grade Anchor Plate 9: 35: 11 AM Anchor Bolts (The quantities above are for one C-I-P Light Pole Pedestal. The concrete quantity for the thickened junction slab is based on a 6" increase in thickness and a 5" wide retaining wall panel. Adjust thickened concrete quantity as required for raised sidewalks 12/30/2011 and sidewalks.) LAST REVISION 01/01/12 REVISIO N DETAIL "A" DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 COPING MOUNTED LIGHT POLE PEDESTAL NO. 6200 SHEET NO. 3 REINFORCING STEEL BENDING DIAGRAMS - DRAINAGE »¿ Barrier Wall BILL OF REINFORCING STEEL »¿ Expansion Joi 10’-0" Min. MARK Sidewalk or Sidewalk, C-I-P Coping and 12 ~ Bars 4S2 @ 8" sp. Bars 5B2 (Field Cut as 8" Junction Slab, Raised REQD. SIZE LENGTH 4b" S2 12 4 3’-1" S3 2 5 10’-0" U2 8 6 VARIES U3 4 5 12’-10" 6’-0" Concrete Parapet 6" A Bars 5S3 1" Preformed Expansion 6" Joint Filler (Typ. all Sides) 1’ -6" Bars 5C (Top) (Typ.) 1’ -6" 6" Wall Inlet) (Typ.) 6" required to clear Barrier 4b " Traffic Railing or STIRRUP BAR 4S2 Barrier Wall Inlet (Grate Bars 5U3 5’ -0" not shown for clarity) 1’-6" (See Index No. 218 for 5’-9" 1’-6" Varies details) BAR 5S3 2" Cover (Typ. all Sides) 3’ -7" Bars 4L (Bottom) (Typ.) 1’ -9" Gutter Line Bars 4A (Top) 5’-8" C: \d\projects\standards\structures\current\ready4release\2012book_draft\06201-1of1. dgn (Typ.) A BAR 5U3 Bars 5S Coping Bars 5V2 (Typ.) BAR 6U2 REINFORCING STEEL NOTES: 8 ~ Bars 6U2 Bars 6U2 1. All bar dimensions in the bending diagrams are out to out. @ 8" sp. (See Note 1) 2. All reinforcing steel at open joints will have a 2" minimum cover. 3. See Index Nos. 6110, 6120 & 6130 for Bars 4A (or 5A), 5B, 5C and 4L (or 5L). PLAN VIEW 4. The Contractor may use Welded Wire Reinforcement when approved by the (Junction Slab Shown, Raised Sidewalk Similar) Engineer. Welded Wire Reinforcement will conform to ASTM A 497. 7’-0b" (See Note 2) NOTES: Gutter Line Bars 5V2 (32" F-Shape shown, (See Note 4) 42" F-Shape similar) and Grate (See for details) Top of C-I-P Coping 4 " 1 " Const. Joint Required 15 ~ Bars 4S2 @ 6" spacing for Raised Sidewalks). 3" Cover 4" Em bed. 7" 6" M in. 3. Actual location & width vary depending on type of Retaining Wall used. See Note 5 6" Coping Bars 5U3 (Rotate as required Bars 6U2 6" to clear junction slab reinforcing) Bars 5B2 Bars 5B2 (Typ.) 4" rd960rh @ 8" sp. 1" Preformed Expansion Joint Filler (Typ.) 4" Cover (Bottom) 9: 35: 12 AM 4. See Index No. 6110 for Bars 5V2 and 5S. 5. Two Layers 30Lb. Roofing Felt (Top) & Expanded Polystyrene shown hatched (b" Each Side). »¿6. Locate Barrier Wall Inlet a minimum of 10’-0" away »¿ Expansion Joints in Junctions Slab, Raised Sidewalk or Side C-I-P Coping and Traffic Railing or Concrete Parapet. 7. Work this Index with the following as appropriate: Index No. 6110 Index No. 6120 Index No. 6130 Retaining Wall (MSE Wall Compacted Sand 2" Cover (Top & Sides) Shown, other Wall Types Similar) 2" Cover 2" Cover See SECTION A-A 12/30/2011 for C-I-P Raised Sidewalk and Sidewalks. Bars 5B2 Bars 4S2 @ 8" sp. Bars 5S3 2. Dimensions shown are for junction slab. Increase width as required Spacing Bars 5S (See Note 4) 1’ -0" Junction Slab. For C-I-P Raised Sidewalks or Sidewalks, match bar spacing and size shown in Typical Sections (i.e., 11 ~ Bars 5U2 and 2’ -3" Index No. 218 Riding Surface 1. Spacing shown is along the Gutter Line. Spacing shown is for C-I-P Recess Barrier Wall Inlet » ¿1 0˘ " (See Note 2) Roadway Pavement C-I-P Traffic Railing Varies ( 10 " Shoulder or 1’-6b " Min. M ax. , 3" M in. ) 4’-5b " 1’-0b" SECTION THRU JUNCTION SLAB, BARRIER WALL INLET AND RETAINING WALL 6" Note 2 LAST REVISION 01/01/12 REVISIO N (Junction Slab Shown, Raised Sidewalk Similar) DESCRIPTION: INDEX FDOT DESIGN STANDARDS FY 2012/2013 JUNCTION SLAB AT DRAINAGE INLET OPENINGS NO. 6201 SHEET NO. 1