Comments
Description
Transcript
FDOT DESIGN STANDARDS 2013 S2
REINFORCING STEEL BENDING DIAGRAMS - DRAINAGE »¿ Barrier Wall BILL OF REINFORCING STEEL »¿ Expansion Joi 10’-0" Min. MARK Sidewalk or Sidewalk, C-I-P Coping and 12 ~ Bars 4S2 @ 8" sp. Bars 5B2 (Field Cut as 8" Junction Slab, Raised REQD. SIZE LENGTH 4b" S2 12 4 3’-1" S3 2 5 10’-0" U2 8 6 VARIES U3 4 5 12’-10" 6’-0" Concrete Parapet 6" A Bars 5S3 1" Preformed Expansion 6" Joint Filler (Typ. all Sides) 1’ -6" Bars 5C (Top) (Typ.) 1’ -6" 6" Wall Inlet) (Typ.) 6" required to clear Barrier 4b " Traffic Railing or STIRRUP BAR 4S2 Barrier Wall Inlet (Grate Bars 5U3 5’ -0" not shown for clarity) 1’-6" (See Index No. 218 for 5’-9" 1’-6" Varies details) BAR 5S3 2" Cover (Typ. all Sides) 3’ -7" Bars 4L (Bottom) (Typ.) 1’ -9" Gutter Line Bars 4A (Top) 5’-8" (Typ.) A BAR 5U3 Bars 5S Coping Bars 5V2 (Typ.) BAR 6U2 REINFORCING STEEL NOTES: 8 ~ Bars 6U2 Bars 6U2 1. All bar dimensions in the bending diagrams are out to out. @ 8" sp. (See Note 1) 2. All reinforcing steel at open joints will have a 2" minimum cover. 3. See Index Nos. 6110, 6120 & 6130 for Bars 4A (or 5A), 5B, 5C and 4L (or 5L). PLAN VIEW 4. The Contractor may use Welded Wire Reinforcement when approved by the C: \d\projects\standards\structures\2013book\06201-1of1. dgn (Junction Slab Shown, Raised Sidewalk Similar) Engineer. Welded Wire Reinforcement will conform to ASTM A 497. 7’-0b" (See Note 2) NOTES: Gutter Line Bars 5V2 (32" F-Shape shown, (See Note 4) 42" F-Shape similar) and Grate (See for details) Top of C-I-P Coping 4 " 1 " Const. Joint Required 15 ~ Bars 4S2 @ 6" spacing for Raised Sidewalks). 3" Cover 4" Em bed. 7" 6" M in. 3. Actual location & width vary depending on type of Retaining Wall used. See Note 5 6" Coping Bars 5U3 (Rotate as required Bars 6U2 6" to clear junction slab reinforcing) Bars 5B2 Bars 5B2 (Typ.) 4" rd960rh @ 8" sp. 1" Preformed Expansion Joint Filler (Typ.) 4" Cover (Bottom) 11: 53: 39 AM 4. See Index No. 6110 for Bars 5V2 and 5S. 5. Two Layers 30Lb. Roofing Felt (Top) & Expanded Polystyrene shown hatched (b" Each Side). »¿6. Locate Barrier Wall Inlet a minimum of 10’-0" away »¿ Expansion Joints in Junctions Slab, Raised Sidewalk or Side C-I-P Coping and Traffic Railing or Concrete Parapet. 7. Work this Index with the following as appropriate: Index No. 6110 Index No. 6120 Index No. 6130 Retaining Wall (MSE Wall Compacted Sand 2" Cover (Top & Sides) Shown, other Wall Types Similar) 2" Cover 2" Cover See SECTION A-A 6/28/2012 for C-I-P Raised Sidewalk and Sidewalks. Bars 5B2 Bars 4S2 @ 8" sp. Bars 5S3 2. Dimensions shown are for junction slab. Increase width as required Spacing Bars 5S (See Note 4) 1’ -0" Junction Slab. For C-I-P Raised Sidewalks or Sidewalks, match bar spacing and size shown in Typical Sections (i.e., 11 ~ Bars 5U2 and 2’ -3" Index No. 218 Riding Surface 1. Spacing shown is along the Gutter Line. Spacing shown is for C-I-P Recess Barrier Wall Inlet » ¿1 0˘ " (See Note 2) Roadway Pavement C-I-P Traffic Railing Varies ( 10 " Shoulder or 1’-6b " Min. M ax. , 3" M in. ) 4’-5b " 1’-0b" SECTION THRU JUNCTION SLAB, BARRIER WALL INLET AND RETAINING WALL 6" Note 2 LAST REVISION 01/01/12 REVISIO N (Junction Slab Shown, Raised Sidewalk Similar) DESCRIPTION: INDEX FDOT DESIGN STANDARDS 2013 JUNCTION SLAB AT DRAINAGE INLET OPENINGS NO. 6201 SHEET NO. 1