Oval Eye Bolt Automatic Compression Type Clamp (Feed Through Dead End) Catenary wire
by user
Comments
Transcript
Oval Eye Bolt Automatic Compression Type Clamp (Feed Through Dead End) Catenary wire
Existing Oval Eye Bolt Oval Eye Bolt No. 6 Copper Ground Wire Pigtail No. 6 Copper Ground Wire Pigtail Crimp Type Electrical Connector Automatic Compression Type Clamp (Feed Through Dead End) Automatic Compression Type Clamp (Feed Through Dead End) 1 ’ 0 " 4" 1 ’ 0 " 1’ 0" 1’ 0" 12" 4" Catenary Wire Locking M in. *** Catenary wire Detail B Detail A Span Wire Clamp Catenary Wire Crimp Type Electrical Locking Cable Ties Connector Or Lashing Wire Signal Cable 8" To 12" Drip Coil Or Drip Loop Cable Tie Locking Cable Ties 8" To 12" Drip Coil Or Drip Loop Or Lashing Wire Existing Oval Eye Tether Wire Bolt 1 2" Service Head 1 See Note No.1 Schedule 80 Aluminum Pipe (If Required) Stainless Steel Pipe or (T6061) With NPSM Threads Louvered Signal Head Louvered 12" M in. Backplates Backplates Oval Eye Bolt Automatic Compression Type Clamp (Feed Through Dead End) Automatic Compression Tether Wire Type Clamp (Feed (If Required) Field Drill Two Through Dead End) Service Head 1 4" Drain Holes In Bottom Of Installed Signals To Allow Water To Drain Signal Cable See Note No.1 The Vertical Clearance To The Bottom Of A Pavement Vertical Or Horizontal Vehicular Signal Head RETROFIT INSTALLATION *** Clamp location shall be adjusted to compensate for reduced »¿Detail A Or B Shall Not Be Less Than 17’-6", And The Balancer Tri-Stud Or Maximum Height Shall Be In Accordance With Threaded Adapter The Standard Specifications. C: \d\projects\standards\roadway\17700-s\17727-01. dgn sag and vertical clearance to bottom of signal head. Detail A or B Disconnect Box 3 4" Oval Eye Bolt Detail A Bottom Method Of Framing Detail A & B Hub Tri-Stud Corner Strain Poles No. 6 Copper Angles 10To 120 Ground Wire Min Span Wire Clamp Aluminum A356-T6 Or 380 With Hardware Alloy With Stainless Steel Bushings, U Bolts, Clevis Pin, Washers And Lock Nuts Of 4’ (Bare Pigtail) LOAD** (Use A Split Clamp On Steel Poles) (Feed Through Dead End Wire Entrance Head Aluminum A356-T6 Or 1 2" Bottom Hub 1 1 2" 380 Alloy Threaded For 1 NPSM Threads Automatic Compression Type Clamps Detail A & B Detail B * Hole For Conduit For Locking 5 8" X 20’ Grounding Electrode (Copperclad) Detail B * Stainless Steel Pipe Or Detail B Schedule 80 112" Stainless Steel Pipe Or Schedule 80 Aluminum (T6061) 112" ** The load face of pole shall PRESTRESSED CONCRETE POLE NEW CONSTRUCTION 12: 30: 47 PM rd960rh be perpendicular to load. Detail B Female Detail B Threaded 112" NPSM Female Threaded Tri-Stud Adapter With Dual Setscrews For Locking Detail A Notes: Detail A or B Chase Nipple Tether Clamp With the approval of the resident engineer, the service head hole for joint use poles may be Tether clamp Aluminum 319 alloy with drilled by the utility company at an angle of 90 but not less than 45 to the face of the pole. Tri-Stud adapter and hardware. 2. Lashing wire should normally be used for distances of 12’ or greater. 3. All hardware for signal attachment shall be stainless steel. 4. Meet all grounding requirements of Section 620 of the Standard Specifications. * For long pipe hangers a wire entrance head may be substituted for balancer and the drop pipe installed above the LAST REVISION 01/01/12 REVISIO N 6/28/2012 Aluminum Pipe (T6061) With NPSM Threads NPSM Threads Tri-Stud Adapter 1. NPSM Female Connection With Dual Setscrews disconnect box. SINGLE POINT ATTACHMENT DESCRIPTION: INDEX FDOT DESIGN STANDARDS SIGNAL CABLE & SPAN WIRE 2013 INSTALLATION DETAILS NO. 17727 SHEET NO. 1 Clamp And Clevis See Index 17723 Oval Eye Bolt Tapped Lug For Grounding Oval Eye Bolt Eyenut For Guy Automatic Automatic Compression Automatic Compression Type Attachment Compression Type Clamp (Feed Clamp (Feed Through Deadend) Type Clamp Through Deadend) Method Of Framing Corner Strain Poles Angles 10 To 120 (Feed Through Deadend) Catenary Wire Catenary Wire 3 4" Catenary Wire Automatic Compression Type Oval Eye Bolt Clamps (Feed Through Deadend) No. 6 Copper Ground No. 6 Copper Ground Wire Ground Wire (Bare) Pigtail Min. Of 12" (Bare). Oval Eye Bolt Crimp Type Electrical Connector »¿LOA Wire (Bare) Oval Eye Bolt No. 6 Copper Crimp Type Electrical Crimp Type Connector Nut & Washer The load face of pole shall be Messenger Wire perpendicular to load. Electrical Connector Messenger Wire Messenger Wire (Use A Split Clamp On Steel Poles) 4" Coupling Nut & Curved 6" Head Entrance Cap Stubbing Washer Lashing Wire Signal Cable Nipple (Stapled To Pole) 12" Locking Cable Ties Or Signal Cable Ground Wire Bare 12" M in. Service Signal Cable Oval Eye Bolt "S" Hook "S" Hook Tether Wire Tether Wire (If Required) (If Required) Service Head Tether Wire See Note No. 1 (If Required) Automatic Compression Type Clamp (Feed Oval Eye Bolt Automatic Compression Through Deadend) Split Clamp Type Clamp (Feed Automatic Compression Type Clamp "S" Hook (Feed Through Deadend) Through Deadend) Conduit Strap Catenary Wire Span Wire Clamp Rigid Conduit Single Eye Balancer Ground Wire Ground Wire To 8’ (Bare) Above Grade With 1 2" - 13 NC 2 Tapped 1 1 2" Lug Inside For Ground NPSM Threads Stainless Steel Pipe Or 12" Conduit For Schedule 80 Aluminum Pipe (T6061) With NPSM Threads M in. 1 2" 1 Reinf. Handhole Frame No. 6 Copper Messenger Wire 8"to 12" Drip Coil Or Drip Loop C: \d\projects\standards\roadway\17700-s\17727-02. dgn 4" Grade 1 2" No. 6 Copper Ground Wire (Bare) PVC Grade Signal Cable Disconnect Hanger Signal Head Louvered Backplates No. 6 Copper Tether Wire Conduit For Ground Wire Min (If Required) Ground Wire Of 4’ (Bare Pigtail) Attach To Signal Head Field Drill Two Hole For Conduit With Breakaway Clips 1 4" Drain Holes In Bottom Of Installed Signals To 5 8" 5 8" X 20’ 5 8" X 20’ X 20’ Grounding Grounding Grounding Electrode Electrode Electrode (Copperclad) (Copperclad) (Copperclad) Allow Water To Drain. The Vertical Clearance To The Bottom Of A Vertical Or Horizontal Vehicular Pavement Signal Head Shall Not Be Less Than 17’-6", And The Maximum Height Shall Be In Accordance With The rd960rh Standard Specifications. WOOD POLE STEEL POLE PRESTRESSED CONCRETE POLE 1. With the approval of the resident engineer, the service head hole for joint use poles may be drilled by the utility company at an angle of 90 but not less than 45 to the face of the pole. 2. Lashing wire should normally be used for distances of 12’ or greater. 3. The overlapped connection of adjustable hangers shall use a minimum of 2 bolts with a minimum spacing of 2" between bolts. 4. TWO POINT ATTACHMENT Meet all grounding requirements of Section 620 of the Standard Specifications. LAST REVISION 01/01/12 REVISIO N 6/28/2012 12: 30: 49 PM Notes: DESCRIPTION: INDEX FDOT DESIGN STANDARDS SIGNAL CABLE & SPAN WIRE 2013 INSTALLATION DETAILS NO. 17727 SHEET NO. 2